| 1 | Taking up or down Steel Tubing 20mm bore (dia) with Fittings/ Connections, segregating Serviceable Pipes and Fittings/ Connections and keep in Safe Custody for re-use, complete all as specified and as directed. (Note : Rates are included upto G+2 Storey) |
| 2 | M&L for 20mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. |
| 3 | M&L for Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all specified and directed |
| 4 | M&L for 10 mm thick cement plaster with CM 1:4 smooth finish for application of waterproof coating primer the surface clean with water complete with making the corner plain and smooth all as directed by Engr-in-Charge. (Note : Rates are included upto G+2 Storey) |
| 5 | Taking down existing damaged APP membrane and clean the surface , frost, surface laitance and contamination and free from loose aggregate, iclean with water complete all as directed by Engr-in-Charge. |
| 6 | M&L for PCC 1: 2 :4 Type B-1 (using 12.5 mm graded stone aggregate) as in padding over roof slab laid to slope finished even and smooth, roof kerbs or mud stops, rounded or chamfered on edges, side coping of sheets complete all as specified and directed. (Note : Rates are included upto G+2 Storey) |
| 7 | Supply only Integral Water Proofing Compound, ISI Marked, as approved, complete all as specified and as directed. |
| 8 | M&L for cleaning the newly plastered surfaces thoroughly with wire brushes and providing water proofing treatment all as specified here in after :- (a) Bituminous primer @ 0.30liter per sqm conforming to IS 3384-1986 (b) 3mm thick APP polymeric membrane minimum weighing 3 Kg/Sqm laid by torch application method with over laps of 100 mm joints of traverse direction and 75 mm at longitudinal direction duly thermofused by flame torch all as specified in application manuel of the company(Note : Rates are inclusive of dismantling and refixing of tanks on the roof.) |
| 9 | M&L for applying each coat of aluminium paint @ 100mm/sqm all as specified and directed |
| 10 | S&F in repair Rotational Moulded Polyethene Water Storage Tank 1000 Litre Capacity, Cylindrical, Vertical with Closed Top, 3 layered, hoisted and fixed in Position all as specified in MES Schedule including dismantling/ lowering down unserviceable Water Storage Tanks, complete all as specified and as directed. |
| 11 | S&F in repair Rotational Moulded Polyethene Water Storage Tank 500 Litre Capacity, Cylindrical, Vertical with Closed Top, 3 layered, hoisted and fixed in Position all as specified in MES Schedule including dismantling/ lowering down unserviceable Water Storage Tanks, complete all as specified and as directed. |
| 12 | S&F in repair Gun Metal Gate Valve 20mm bore (dia) with Iron Wheel Head including Flange, screwed both Ends for Iron Pipe and fixed-in-repairs, complete all as specified and as directed. |
| 13 | S&F in repair Ball Valve 20mm dia (minimum Weight 210 Gram), high pressure of PTMT with epoxy coated Aluminium Rod and high density Plastic Ball, screwed for Iron Pipe and fixed-in-repairs, complete all as specified and as directed. |
| 14 | Dismantling wrought iron or mild steel, sheet work of any description not otherwise provided for all as spd and directed (Note: Ht of work may Vary upto 15.00 m ) |
| 15 | S&F galvanized, black, mild steel sheeting of 1.25 mm, in ridges, hips, valley gutters, drip and straight flashings all as spd and directed (Note : Ht of work may Vary upto 15.00 m ) (Note ; Item no 16 to 18 is considered for changing of valley gutters and may include dismantling and refixing of sheets and steel work. It is advised to vidit the site before quoting the rate.) |
| 16 | M&L for 2 mm thick coloured acrylic sheet with building number or name printed over it and fixing with nails/screwson building upto G+2 storey of desired size, pattern & colour as directed by Engr-In-Charge complete all as specified and directed.( Note : rates of printing, writting im the sheet deemed to be included in the rate) |
| 17 | Demolition of brick work or stone/boulders Masonry built in cement mortar or cement lime mortar including all quions, arches, pillars, ect but excluding ashlar facings dressed stone work and precast concrete articles. |
| 18 | M&L for brick work with sub class 'B' brick, straight or curved on plan exc 6.0 mtr mean radius built in CM 1:4 etc complete all as specified and directed |
| 19 | M&L for brick work with sub class 'B' brick(except brick), straight or curved on plan exc 6.0 mtr mean radius built in CM 1:4 etc complete all as specified and directed |
| 20 | M&L for PCC 1:3:6 type B1 using 20mm graded stone aggregate as in floor 40 mm thick finishing the surface without using extra cement complete all as specified |
| 21 | Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc |
| 22 | M&L for rendering 15 mm thick in CM 1:4, finished even and smooth without using extra cement complete all as specified and as directed |
| 23 | M&L for Rough cast plaster on brick walls consisting crushed stone or fine gravel mixed of size 6mm with coarse sand and cement in the ratio 1:1:1 shall be applied and finish even completed all as specified & directed by Engr-in-charge.(Ht may vary upto 2 storey building.) |
| 24 | M & L for prepring any type of newly plasetered surface of walls and applying two coats of weather coat exterior paint ( in camouflage/plain pattern as directed) over a coat of primer ( as per manufacturer's instruction) all as specified and directed. |
| 25 | Excavation in trenches n.exc 1.50mtr wide and 1.50mtr in depth for foundation etc or for shafts, wells cessipts, manhole etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr deth and getting out in soft /loose soil etc complete all as specified and as directed |
| 26 | Returning filling in, with soil inlcuidng spreading, levelling, watering and well ramming in layers not exc 25 cm thicks etc complete all as specified and as directed |
| 27 | Removing excavated soil/ building material/debries to a distance exc 250 mtr but not exceeding 500 mtr and depositing where directed etc complete all as specified and directed |
| 28 | M&L for cement concrete 1:4:8 type D-2 (using 40mm graded aggregates) as in foundation and mass concrete etc complete all as specified and directed |
| 29 | M&L for cement concrete 1:2:4 type, B1 using 20 mm graded stone aggregates as in copings including necessary use and waste formwork, weathering, slightly rounded or chamfered angles and throating etc complete all as specified and directed |
| 30 | Dismantling wrought iron or mild steel work of any description etc complete all as specified and directed |
| 31 | S&F framed work such as grills, gratings etc with ends of bars shouldered and or riveted or forged into spikes framed guard bars barred iron doors ladders framed balusters walk way railing grame work of wastertanks and similar work confiming to Fe.290, Gde E-165 etc complete all as specified and as directed |
| 32 | Dismantling post or struts (wood, steel or RCC) any section incl. taking out embedded portion and making good disturbed ground posts embedded in natural ground complete all as directed. |
| 33 | Earth work excavation in post holes ( or similar holes) in hard/dense soil ,each not exceeding 0.50 Cum ,getting out ,returning filling in and ramming earth or broken rubble mixed with earth around ,in layers not exceeding 25 cm ,watering and removing surplus soil. |
| 34 | S&F Framed mild steel work as in posts/ struts in fencing including cutting tops to shape, drilling holes,bolting,rivetting flat etc. complete conforming to Fe-290 gde E165 all as spd and directed |
| 35 | S&F Framed mild steel work as in gates including pintel hinges, stops, hand made sliding bolts etc. complete conforming to Fe-410-0 or Fe-310-0 all as spd and directed |
| 36 | S&F 8 mm dia and over Machine made screw bolts with hexagonal or square head at one end and screwed the other each screwed end to be fitted with washers and one hexagonal nut exc 5 and not exc 10 cm long all as spd and directed |
| 37 | S & F for 8 mm dia or over MS bars as in strainers for chain link fencing including necessasary welding and fixing to angle iron complete all as specified and directed. |
| 38 | Dismantling fencing wire mesh, any type etc complete all as specified and directed |
| 39 | Fixing only chain link fencing including line wires, any mesh, size and any type of standards, rails, straining bolts etc. |
| 40 | S & F in repair galvanised 2 strand steel barbed wire 2 mm dia barbed with 2.3 mm dia barbs at 75 to 80 mm spacing and straining, fixed to fencing post tieing at crossing with and including galvanised mild steel wire complete all as directed. |
| 41 | Supply only Chain link MS galvanised fencing , any size or type all as specified and directed |
| 42 | One coat of synthetic enamel paint on old painted steel surfaces of any description over 10 cm width or girth including preparation of surfaces all as specified and as directed. |
| 43 | Dismantling of plain or corrugated steel sheeting or mangalore tile roof any guage, thickness from roof covering complete all as specified. |
| 44 | S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified. |
| 45 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. .Fe-410- W(Gde E-250)quality-B |
| 46 | Preparing new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer |
| 47 | S&F 30-35 mm thick GRC/GFRC Jali by drilling or patching it in walls/RCC Columns including dismantling old RCC jali all as specified and directed |
| 48 | M&L for type B0 1:2:4 (12.5 mm graded aggregate)Providing precast cement concrete louvres and jallies of type B0 1:2:4 (12.5 mm graded aggregate), 25mm thick set in 1:4 cement mortar including fixing in existing frame complete all as specified and directed |
| 49 | Desigining and providing and fixing Aluminium Composite Clading 3mm thick with FR grade mineral core sandwiched between two aluminium sheets (each 0.5mm thcik) of over RCC/Brick surfaces either segmental/ straight in plan wherever specified with extruded aluminium U section, angle, cleats, weather sealants, backer rods of required size stailess steel screws,rivets,brackets,drilling and fixing the cladding to either masonary or reinforced cement concrete as the case may be manufacturer's specifications, complete the work in all necessary accessories. At all soffits aluminium cladding shall be bend 90 degree and joints at corner or edges will not be acceptable. On horizontzl surfaces, the size of sheet should be maximum available of size complete all as per manufacturer's specification and as directed by Engr-In-Charge. |
| 50 | M & L for Precast coloured ceramic pavement tiles 300x300x7-8 mm thick laid in floorings as per manufacturer size over a screed bed of CM 1:6, 20 mm thick all as specified. |
| 51 | Supply, febrication and fixing of stainless steel 304 grade letters incl vowels smooth finish as per sample provided (Hindi/ English) on granite wall/Steel sheet made out of 1 mm thick stainless steel sheet (minimun size not less than 40mm thick, 100-150 mm in width and 300-600 mm high) and 10 mm dia, 75mm long MS studs weld with back side of letters as per site requirement fix on granite wall/Steel sheet making holes by drilling machine and studs fix with epoxy adhesive/nut bolts complete all as directed by Engr-in-Charge. |
| 52 | Demolition cement concrete (unreinforced) in qround floors and pavings n.exc 15cm thickness below or above GL) excluding ashlar facings, dressed stone work and precast concrete articles. |
| 53 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 54 | M&L for PCC 1:3:6 type C1 using 20mm graded stone aggregate, 75 mm thick as in plinth protection finished even and fair. |
| 55 | M & L for 75 mm PCC 1:4:8 type D2 (Using 40mm graded stone aggt) as in subbase or floors complete all as specified and dircted |
| 56 | Machine pressed precast concrete interlocking paver block with glossy finish any shape and size confirming to IS 15658 – 2006 of 60 mm thickness, M-35 Grade, with grey cement and pigment,over new sub-base laid over and including 20mm thick screed be complete all as specified. |
| 57 | M&L for 20-25 mm thick precast chequered tiles glossy finish of size 300 x 300 mm, coloured, pre-polished, set and jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles, as in floor, laid over and including 20mm thick screed bed i, all as specified and as directed. |
| 58 | M&L for 1.25 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required |
| 59 | S&F in repair Steel rolling shutters 1.25 mm laths, with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete with all necessary fittings all as specified and directed |
| 60 | M&L Repairs/Maintenance of Steel Gate/ Collapsible Gate( of any size), Oiling/ Greasing of all Moving Parts of the Gate and making Serviceable for Free Movement of Gate including replacement/adjustment, welding, drilling, etc. of all Minor Parts (viz Nuts, Bolts, Rods, Flat Iron, Angle Iron, Guide Rail, Ball Bearing, etc. of Steel Gate including Taking down and Re-fixing Steel Gate wherever necessary, complete all as specified and as directed. |
| 61 | M&L Taking down existing Steel Rolling Shutter including Hood Cover, Pull and Push type, area not exc. 8.0 Sqm Each, Sides of clear Opening and Cleaning the Side of Shutter Suspension Shafts, Anti-guide Channels and Greasing all the Moving Parts of the Rolling Shutter and straightening Rolling Shafts and replacement of Bolts, Nut, etc. as required for Smooth Functioning of Shutter and Re-fixing the same including Hood Cover, complete all as specified and as directed. |
| 62 | S & F in repair hot dipped galvanised concertina razer tape coil 1020 mm dia, spring steel high tensile centre core wire 2.5 mm dia having 200-250gm zinc coating, 0.5 mm thick razer sheet having 90-120gm, zinc coating & min 10 mm width ( before wraping centre core wire),with GI clip 1.6 mm thick complete all as specified and directed. |
| 63 | M&L for preparing old plastered surafce of wall for finishing with acrylic smooth exterior paint of required shade upto two storey of one coat all as specified and directed |
| 64 | Preparing Old Treated/Painted Steel and Iron Surfaces of any description, and applying Two Coat of Synthetic Enamel Paint (First quality) for Y shape Mild steel Angle Frame( area exc 0.25 Sqm but not exc 0.50 Sqm Each) fixed on boundary walls (Straining /Supported to barbed Wire and Concertina Coil) complete all as specified and as directed. Please Enable Macros to View BoQ information |