| 1 | JOB No. 3BRD/CAP/04/2025-26 |
| 2 | Demolition of cement concrete un-reinforced in any position and paving not exc 15cm thick above or below ground level complete all as specified and as directed. |
| 3 | M&L for broken stone or boulders hard core of gauge exc. 63 mm but not exc. 100 mm, deposited, spread and levelled in layers not exc.15 cm thick, watered and rolled rammed to a true surface complete all as specified and directed. |
| 4 | M&L PCC (1:4:8) type D2 using 40mm graded crushed stone aggregate as in 100mm thick as in sub base complete all as specified & directed by Engr-in-Charge. |
| 5 | M& L for plain cement concrete type A-1 (1:1.5:3) (Using 20 mm graded crushed stone aggregate) as in hard standing finished with even and smooth with using extra cement including use and waste form work complete all as specified and directed. |
| 6 | M & L for forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade `A' complete all as specified and directed. |
| 7 | M & L for finishing surface to concrete roads, pavements, by brooming complete all as specified and directed. |
| 8 | Taking down chowkhats or frames with shutters without taking off shutters from frame exe 1.5 Sqm but n.exc 4.0 Sqm each complete all as specified and directed. |
| 9 | Taking down chowkhats or frames with shutters without taking off shutters from frame n.exe 1.5 Sqm each complete all as specified and directed. |
| 10 | S&F for mild steel holdfast, bands, straps, bracket/ clamp for eves gutter, valley gutter and similar conforming to Fe-290 Gde-E-165 complete all as specified and as directed by Engr-in-Charge |
| 11 | M&L for cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in lintel upto 1.5m clear span, steps, bed plates, kerb, coping & kitchen slab etc including necessary formwork complete all as specified and directed by Engr-in-Charge |
| 12 | S&F for Framed work such as Gate, grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including necessary welding complete all as specified and directed |
| 13 | Supply, Providing and fixing factory made uPVC white colour fixed window area not exceeding 1.0 Sqm made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 4mm thick glazing with selected quality glass.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories Net opening will be measured for payment purpose.) |
| 14 | Supply only plain sheet glass 4.0 mm thick ordinary quality and glazing with aluminum glazing clip in aluminum window shutter not exc 0.5 Sqm in each pane. |
| 15 | Supply only water proofing compound complete all as specified and directed |
| 16 | Taking down cement plaster on brick /stone masonry / concrete surfaces of wall / ceiling incl raking out joints, hacking for key, scrubbing down with water etc and deposited the debris outside the MD land complete all as specified. |
| 17 | M&L for rendering 15mm thick in cement mortar 1:4 including with mixing water proofing compound on Brick/ concrete/ block masonry surfaces and finished fair and even without using extra cement on all as specified and as directed. |
| 18 | M&L for 10mm thick plaster in cement mortar 1:6 on fair faces of Brick/ concrete/ PCC block surfaces of walls finished even and smooth (without using extra cement) all as specified and as directed. |
| 19 | Taking down of damaged, loosened cement concrete/cement mortar in RCC walls/soffits of slabs, Columns, beams etc and similar structure members up to depth of 20mm to 40mm cleaning the dismantled portion with wire brush etc remove dust , dirt and other foreign particles etc and washing with water with pressure and applying bonding agent on old concrete surfaces all as per manufacturers instruction, Over prepared surfaces provide 20 mm thick High build polymer modified cement sand mortar ( 1:2.5 ) mixed with 10 litres (minimum) Nitobond SBR per 50 kilogram of cement of M/s FOSROC chemical (India) Pvt Ltd/M/s SIKA INDIA Pvt Ltd/M/s STP or Equivalent product of manufacturer all as manufacturers instruction including necessary scaffolding up to 12 m complete all as specified and directed by Engr-in-Charge. |
| 20 | M&L for preparation of newly plastered wall surfaces with 3mm average thick wall care putty and applying two coat of oil bound distemper over one coat of primer including leveling the surface which undulation found with cement putty etc complete all as specified and directed. |
| 21 | M&L for for preparation of old plastered/unplastered/ concrete surfaces of walls and applying two coats of exterior emulsion paint (in camouflage pattern using number of colours) over and including one coat of primer and at any height including necessary scaffolding etc complete all as specified.Note : Pattern of camouflage shall be approved by GE. |
| 22 | M&L for PCC (1:3:6) type C-1 (20 mm graded crushed stone aggregate) 75mm thick as in plinth protection with even and smooth finishing without using extra cement complete all as specified and directed. |
| 23 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in Soft/loose soil complete all as specified and as directed. |
| 24 | S&F for roof trusses (framed), trussed, purlines, rails and fastening and heavy brackets framing (beam, tee, angle, channel or flats section) including distance pieces, cleat etc conforming to Fe-410 (Gde-E250) quality -A complete all as specified and as directed. |
| 25 | M&L for preparation of new steel surfaces over 10 cm in width or girth not otherwise described and applying 2 coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 26 | M&L for preparation of old steel surfaces over 10 cm in width or girth not otherwise described and applying one coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 27 | S&F for pre painted Galvalume aluminium zinc (AZ-150) coating GI based corrugated/trapezoidal section of steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering fixed with self tapping screws complete all as specified and as directed. |
| 28 | S&F for pre painted Galvalume aluminium zinc (AZ-150) coating GI based Plain steel sheet 0.50mm thick of an coloure having tensile strength of 550Mpa as in roof covering fixed with self tapping screws complete all as specified and as directed. |
| 29 | Supply and fixing 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with L-type or J-type or cranked hook bolts or self tapping screws in lieu of screw, complete all as specified and directed. |
| 30 | M&L for brick work subclass \\"B\\" bricks straight or curved on plan exc 6m mean radius built in cement mortar 1: 4, complete all as specified and directed. |
| 31 | M&L for flush pointing to brick laid flat or side in cement mortar 1:4 as in drain/ channel complete all as specified and directed. |
| 32 | M&L for precast RCC (1:2:4) type B1 (using 20mm graded stone aggregate) set in cement mortar (1:4) as in cover slabs placed in position complete incuidng necessary form work and demolition of cement concrete (reinforced) of any description and in any position not otherwise specified provided for and removing the demolished material out side defence land complete all as specified and directed. |
| 33 | S&F TMT bars 10mm dia and over, cut to length bent to shape required including crankig bending spirally for hoping for columns hooking ends and bingings with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed. |
| 34 | M&L for Treating soil along the external wall below concrete or masonry apron using chemical emulsion {Chlorophyriphos 20 EC conforming to IS 8944 or Imidacloprid 30.50 SC conforming to IS 16131 (Refer Table 1 on Sl. Page No. 2 of IS 6313 (Part 2) : 2013)} @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron, complete all as specified and directed. |
| 35 | M&L for Treatment of soil under existing floors using chemical emulsion (Chlorophyriphos 20 EC conforming to IS 8944 or Imidacloprid 30.50 SC conforming to IS 16131 (Refer Table 1 on Sl. Page No. 2 of IS 6313 (Part 2) : 2013)} @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors, complete all as specified and directed. |
| 36 | M&L for Treating the soil under plinth protection at the rate of 5 litres of chemical emulsion (Chlorophyriphos 20 EC conforming to IS 8944 or Imidacloprid 30.50 SC conforming to IS 16131 {Refer Table 1 on Sl. Page No. 2 of IS 6313 (Part 2) : 2013)} per square metre of surface area, complete all as specified and directed. |
| 37 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed. |
| 38 | Taking down carefully of point wiring (Light, fan, socket or power complete fittings such as switches, Ceiling roses, pendants, regulator, sockets, Bell push) removing from site of work and making good to the disturbed surfaces of walls / floors etc complete all as specified and directed. NOTE :- Taking down of Light fitting, MCB, DB etc to be measured and paid separately. |
| 39 | Taking down carefully by submain wiring/service connection of any complete all as specified & directed. |
| 40 | Taking down carefully DB box of any sizes & capacity complete all as specified and directed. |
| 41 | M&L for Concealed Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed (FRLS) cable, multi-stranded, copper conductor, in universal colour code with & including suitable size of rigid non-metallic UPVC conduit (not less then 20mm dia medium grade) and its all accessories complete concealed in wall / roof including cutting & chases and modular flush metal boxes 0.8 mm thick (Same as Switches Make) suitable for modular fittings including modular outer cover mirror/Glass finish plate with inner mounting frame of make Legrand (Arteor)/ Schneider (Zencelo)/ Anchor (Panasonic Thea)/ Goldmedal (Nixon Z9) as per site requirement for mounting modular switches, sockets etc including earth wire of PVC insulated (FRLS) copper conductor multistranded of 1.5 Sqmm size in green colour for fan point controlled by one switch including making good (i.e plastering in cement mortar 1:6, one coat of putti and two coats of interior emulsion paint with matching existing surface) complete all as specified in current SSR Part-I & II all as directed. |
| 42 | All as per Srl item No. 41.00 here-in-before but One 3-pin socket outlet 5 Amp on independent board. |
| 43 | All as per Srl item No. 41.00 here-in-before but One 3 pin socket outlet 5 Amp on same board. |
| 44 | Material and labour Sub Main Wiring with two run single core 1.5 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed 1100 volts grade colour code cables, drawn on surface in and including UPVC conduit of 25mm dia bore medium grade, including standard fittings such as Tees, junction, bends etc., with and including one run of continuous multi stranded copper conductor 1.5 Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100 volts grade colour code cable for earth continuity including making good (i.e plastering in cement mortar 1:6, one coat of putti and two coats of interior emulsion paint with matching existing surface) complete all as specified and directed.Note:- Two run of 1.5 Sqmm (phase+ Neutral) + One run of 1.5 Sqmm for earth wire + One run of UPVC conduit of 25 mm dia shall be measured as one RM. shall be measured as one RM. |
| 45 | Material and labour Sub Main Wiring with two run single core 2.5 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed 1100 volts grade colour code cables, drawn on surface in and including UPVC conduit of 25mm dia bore medium grade, including standard fittings such as Tees, junction, bends etc., with and including one run of continuous multi stranded copper conductor 2.5 Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100 volts grade colour code cable for earth continuity including making good (i.e plastering in cement mortar 1:6, one coat of putti and two coats of interior emulsion paint with matching existing surface) complete all as specified and directed.Note:- Two run of 2.5 Sqmm (phase+ Neutral) + One run of 2.5 Sqmm for earth wire + One run of UPVC conduit of 25 mm dia shall be measured as one RM. shall be measured as one RM. |
| 46 | Supply and Fixing Modular switch 6 Amps single pole one-way, 1 Module and no top gap between rocker plate and fully shrouded double rocker mechanism type all the important parameters like rating etc should be laser printed on every switch along with catalogue number complete all as specified. Make : Legrand (Arteor) / Schneider (Zencelo) / Anchor(Panasonic Thea) / Goldmedal (Nixon) |
| 47 | Supply and Fixing Modular socket shutter type, 2-in-1, 3 pins 6 Amps, ISI marked, combined 2 Module and no top gap between rocker plate and fully shrouded double rocker mechanisam type all the importent parameters like rating etc should be laser printed on every switch along with catoulage number complete all as specified. Make : Legrand (Arteor) / Schneider (Zencelo) / Anchor (Panasonic Thea) / Goldmedal (Nixon). |
| 48 | Supply and fixing of MCB protected modular socket with Modular MCB 16 Amps built in MCB+ 16 Amps Top + Socket 16 Amps with concealed metal sheet steel enclosure (same as per socket make) with inner mounting frame and outer modular mirror / Glass finish cover for mounting complete including making good (i.e plastering in cement mortar 1:6, one coat of putti and two coats of interior emulsion paint with matching existing surface) complete all as specified and directed. Make (Model) : Legrand (Arteor) / Schneider (Zencelo) / Anchor (Panasonic Thea) / Goldmedal (Nixon Z9). |
| 49 | Supply and Fixing Modular ceiling rose surface bakelite Square in shape 100x100 mm, three terminals complete all as specified. Make - Goldmedal or equivalent in Anchor / Cera. |
| 50 | Supply and fixing MCB Single pole 6 to 32 Amp, 240V, 10KA, 'C' integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, with efficient air chanels etc complete all as specified.Make : Havells/ Legrand/ ABB. |
| 51 | Supply and fixing wall mounted fan of sweep 450 mm, 100 CMM, 90 W, 1350 RPM, Three number aluminium aerodynamic blades, 3 speed controller, silent operation, black in colour, portable type, operating voltage at 220-240 V with all mounting accessories complete all as specified and directed. Make - Goldmedal/ Orient/ Almonard. |
| 52 | Supply and fix TP&N Vertical Loadline distribution board, 4 Way, Double door, IP 43 rated, concealed in wall with Copper bus-bar 200 Amp, neutral link, earth bar and din rail, 415 V, with all conections suitable for fitting DPX3 160 frame size MCCB complete all as directed. |
| 53 | Supply and fixing MCCB 40 Amp rating, 4-pole 415V, breaking capacity 16KA, Adjustable & fixed magnetic setting type with outdoor enclosure suitable for fitting DPX3 160 frame size MCCB complete all as specified and directed. |
| 54 | Supply & fixing indoor decorative ultra slim surface /Wall mounted LED batten tube light complete fitting 1 x 22 watt LED Tube fitting aluminium channel housing with earth green wire & integrated electronic driver, energy efficient, 140V-270 volts, lumen efficacy 120 lumen/watt, total lumens 2640, complete with three core twisted flexible copper conductor cable of suitable size upto 1 metre all as specified and directed. |
| 55 | Supply & laying of UG cable XLPE insulated armoured heavy duty elect cable with stranded aluminium conductor 1100 volts grade cross section area 16 Sqmm 4 core laid in trenches/ fixing on panels/walls/poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts etc including taking out of exisitng unserviceable cable of any size and description including removing /taking out damaged XLPE cable complete all as specified and directed. |
| 56 | Excavation in trenches in soft/loose soil not exceeding 1.5 metre in depth and not exceeding 1.5 metre wide for laying of cables, erection of poles, struts, stays etc and getting out all as specified and as directed by Engr-In-Charge. |
| 57 | Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested, poles, stays, struts hane been erected and tested complete all as specified. |
| 58 | Removal of excavated surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified. |
| 59 | Supply and Spread Natural Riddled soil in trenches for cushioning and covering to cable complete all as specified and directed by Engr-in-Charge.Note : (i) Natural soil shall be riddled by using sieve to separate composite particles etc as per IS and refilling in trenches before laying of cable 8 cm and 15cm after laying of cable. This is then gently punned down to a depth of 10cm above the top of upper-most cable. (ii) For the purpose of measurement only punned thickness only will be considered for payment. |
| 60 | M&L for laying in trenches precast concrete cable covers Class LV, Type I, flat, size 250 mm x 150mm x 40mm for cable protection laid adjacent to each other length wise perpendicular to the central axis of cable complete all as specified. |
| 61 | M&L HDPE Pipe 50 mm dia for protection of cable, concealed in wall including cutting chasing and making good (i.e plastering, one coat of putti and two coats of Apex paint with matching existing surface), complete all as specified and directed. |
| 62 | S&F wind driven turbo ventilator outer dia 30’’ effective throat 24’’, Min 1900 CFM at 20 ft height with respect to wind velocity 8 km/hr, thickness of vanes 0.5mm, minimum 2 Nos bearings, MOC : S.S-304 for bottom & plates, industrial SS 304 for vanes complete all as directed.Make : Almonard / Ventex / Airvent / Ventair / Turbo Whirl / Systemair. |
| 63 | Supply and making hole in New PVC Tranparent sheet suitable for wind driven turbo ventilator outer dia 30’’ etc including replacing of existing PVC sheet all as specified and directed. |
| 64 | Supply and fix Precast (Factory Manufactured) RCC Earthing pit of size 450 mm x 450 mm x 450 mm with 50 mm thickness with RCC Mortar design precast Pit cover, earth work including PCC 1:3:6 50mm thickness at bottom complete all as specified. Make - OM Precast /Dagar Tiles / AC Construction /Venus /Balaji /Any other Precast RCC manufacturer approved by any Command. |
| 65 | M&L Galvanized sheet Earth marker of size 200mm x 200 mm x 1.6 mm, yellow colour painted with angle iron 20 mm x 20mm x 5 mm thickness, 600 mm length including PCC, earth work, earthing pit Number, result, date complete all as directed and specified. |
| 66 | Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal dust (100 kg) and common salt (150 kg), vegetable soil (300 kg), including GI wire 4 mm dia as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 15 mm dia light grade GI protection pipe upto 7.5 metre and watering pipe 20 mm dia light grade with funnel and wire mess including necessary earth work i.e Exacavation and removing outside MoD land, with dismantling old earthing, complete all as directed and specified.Note : The earth value/result must be less than 5 ohms. |
| 67 | JOB No. 3BRD/MW/08/2025-26 |
| 68 | Supply and laying of MS pipe, Class 'C' confirming to IS 1239/3589, heavy class, Nominal Dia 80 mm, chilled water piping including necessary fittings viz. bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators duly insulated Insulation of MS Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete Pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fastners) with necessary accessories complete all as specified and directed. |
| 69 | S&F Gun metal gate valves 80 mm dia, class 1 with Close and open indicator, locking arrangements, screwed at both ends, high pressure with handle, ISI Marked all as specified and directed. |
| 70 | M&L for Cutting existing steel tubing of size upto 100mm bore for alterations or additions (each cut measured) done in position without taking down complete all as specified and as directed. |
| 71 | M&L for welding existing steel tubing upto 100 mm for alterations or additions (or lenghtening screw on pipe to form connector) done in position without taking down complete all as specified and as directed. |
| 72 | M&L Cutting of Bituminous road of size 45 CM x 75 CM including making good of disturbed surface by instant ready mix road patching bituminous material compound all as specified and directed. |
| 73 | JOB No. 3BRD/MW/06/2025-26 |
| 74 | Supply and install Water cooler, fully stainless steel body, Storage Capacity 80 Litres, Cooling Capacity 40 Litres/hour, No of faucets 02, R134a refrigerant, 2.3 Amps current carrying capacity all as specified and directed.Make - Blue star/ Voltas/ Havells. |
| 75 | Supply and install Refrigerator 380 litres, double door, 3 Star rating, Smart invertor compressor all as specified and directed.Make - Whirlphool/ LG/ Samsung. |
| 76 | Supply and install Refrigerator 165 litres, single door, 5 Star rating, Smart invertor compressor all as specified and directed.Make - Whirlphool/ LG/ Samsung. |
| 77 | Supply and install Deep freezer 515 litres, 5 star rating, temperature range +8 Degree to -26 degree, R 290 Refrigerant, No of lids 02, PUF Insulation 60 mm, hard top Lids all as specified and directed. Make - Blue star/ Haier/ Voltas. |
| 78 | Supply and install Deep freezer 215 litres, 4 star rating, temperature range +8 Degree to -26 degree, R 600 Refrigerant, No of lids 01, PUF Insulation 60 mm, hard top Lids all as specified and directed. Make - Blue star/ Haier/ Voltas. |
| 79 | Supply and install water dispenser made of food grade plastic with bottom water bottle storage of size 31 cm x 36.5 cm x 109 cm having option of dispensing hot, normal and cold water with cooling capacity 3 litres/hour and cold/normal stainless steel tank capacity of 3 litres, heating capacity 5 litres/hour and heating stainless steel tank capacity 1 litre, working with eco friendly refrigerant R-134a complete, total weight 15 Kg, power heating 510 W, power cooling 100 W with bottle water 15 litres all as specified and directed. Make : Voltas/ Blue Star/ Usha/ Havells. |
| 80 | Supply and fixing of MCB protected modular socket with Modular MCB 16 Amps built in MCB + 16 Amps Top + Socket 16 Amps with concealed metal sheet steel enclosure with inner GI frame with outer glass finish modular cover for mounting complete all as specified and directed. Make : Legrand (Arteor) / Schneider (Zencelo) / Anchor(Panasonic Thea) / Goldmedal (Nixon Z9). |
| 81 | Supply and fixing Motar starter red and green switch, 2 Module, 16 Amps with concealed metal sheet steel enclosure with inner GI frame with outer glass finish modular cover for mounting complete all as specified and directed. Make : Legrand (Arteor) / Schneider (Zencelo) / Anchor (Panasonic Thea) / Goldmedal (Nixon Z9). |
| 82 | Material and labour for Concealed Sub Main Wiring with two run single core 4 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed 1100 volts grade colour code cables, drawn on surface in and including UPVC casing & caping with and including one run of continuous multi stranded copper conductor 4 Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100 volts grade colour code cable for earth continuity and making good disturbed surface complete all as specified and directed.Note :- Two run of 4Sqmm + One run of 4Sqmm for earth wire + One run of UPVC casing & Caping shall be measured as one RM. |
| 83 | Note :- Amount of credit of Rs. 13400.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender. Please Enable Macros to View BoQ information |