| 1 | Dismantling and taking out damaged/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as specified and directed. |
| 2 | Taking out of unserviceable insulator of any type complete all as specified and directed |
| 3 | Dismantling and taking out old damaged ACSR or AAC conductor complete all as specified and directed |
| 4 | Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of cables and foundation of poles ,stay assembly and getting out in any type of soil complete all as specified and directed |
| 5 | Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers n.exc 25cm each complete all as specified and directed |
| 6 | Removing excavated soil n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed |
| 7 | M&L GI pipe of size 80 mm light grade for floor, road cutting and protection of cable complete all as specified and directed. |
| 8 | M&L GI pipe of size 50 mm light grade for floor, road cutting and protection of cable complete all as specified and directed. |
| 9 | M&L GI pipe of Size 40 mm light grade for floor, road cutting and protection of cable complete all as specified and directed. |
| 10 | M&L clear dry and sharp sand as in cushioning 15cm thick layer before laying and 8cm thick over and under cable laid in trenches complete all as specified and directedNote : Thickness after punning shall be measured. |
| 11 | M&L unreinforced precasted concrete cable cover class LV, type 1,flat , size 250mm x 150mm x 40mm complete all as specified and directed |
| 12 | M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 25 sqmm 4 core complete all as specified and directed |
| 13 | M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16 sqmm 4 core complete all as specified and directed |
| 14 | M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16 sqmm 2 core complete all as specified and directed |
| 15 | M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 95 sqmm 3.5 core complete all as specified and directed |
| 16 | M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 120 sqmm 3.5 core complete all as specified and directed |
| 17 | M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 185 sqmm 3.5 core complete all as specified and directed |
| 18 | M&L bus bar chamber of Size 750 x 600 x 500 mm outdoor pedestal type, factory made, powder coated made out of 3.15 mm thick CRCA sheet dust and vermin proof complete with openable shutter in front and rear having proper locking arrangement, duly powder coated with 250 Amp 430 V 4 pole , 36 KA MCCB as incommer control and including 400 Amps, 4 pole Aluminium bus bar mounted on insulator, suitable for 3 phase, 415 volts, 50 Hz AC supply including control wiring to panel with suitable Size of PVC insulated and sheathed copper cable, duly mounted on angle iron frame 50x50x6 mm including necessary PCC foundation work in all respect with phase indicator lamps (R, Y. B) – 01 Set. complete all as specified and directed |
| 19 | Supply, Install & testing and commissioning factory made (incl CPRI type test certified) LT feeder pillar box (KIOSK) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bar 500 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 40 x 40 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm complete all as specified and directed. The scope of work includes the following :- |
| 20 | (a) INCOMING |
| 21 | MCCB 4 Pole 415 volts grade 320 Amps rating and 36 KA rupturing capacity -01 No |
| 22 | Voltmeter 0-500 volts, Square 96 mm, flush pattern with 3 way rotary selector switch-01 No |
| 23 | Ammeter size 96 mm, square dial flush pattern having dual range 200 Amps with three way rotary selector switch -01 No |
| 24 | CTs ratio 160/5 class ISI marked sets of three each |
| 25 | Indicating lamp-01 set of three |
| 26 | (b) OUTGOING |
| 27 | MCCB 415 volts grade125 Amps rating and 16 KA rupturing capacity -02Nos |
| 28 | MCCB 415 volts grade 250 Amps rating and 36 KA rupturing capacity -01Nos |
| 29 | MCCB 415 volts grade 63 Amps rating and 16 KA rupturing capacity -01Nos |
| 30 | MCB SPN 32 Amps 10KA - 02 Nos |
| 31 | S&F in replacement thermoplastic polystyrene/ polycarbonate enclosure shock proof, IP 65 (weather proof) rust proof, dust proof, water proof, internally embeded gasket with provision for all side cable entry through gland (IP-65) and /or gromments (IP-55) size of enclosure (250x 200 x 105mm ) with suitable connectors for / 3 phase loop in loop out and branch out vibration proof connections and fixing on PCC / Steel poles with 25 x 3 mm thick 02 Nos of clamp with nuts bolts and washers and proper thimbling complete all as specified and directed |
| 32 | S&F in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54.the contactor,MCBs and copper circuit wiring (min.16sqmm) should enough to take: three-phase load of 12KW;contactor Rating 80Amps; MCB(SPN) Rating 80Amps complete all as specified and directed.MAKE:-Nature switch :Kakatiya energy systems pvt.ltd. hyderabad/bajaj/healer. Contactor:- BCH/L&T/Schneider or equivalent (as per IEC-60947-4-1/IS-13947-4-1), MCBs(Input-output):Hager/schneider/L&T/BCH or equivalent (as per IEC-60898/IS-8828),Circuit wiring : Finolex/polycab/RR Kable or equivalent. Model no SWADEEP-02EC12KW3P. |
| 33 | S&F in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54.the contactor,MCBs and copper circuit wiring (min.10sqmm) should enough to take: Single-phase load of 5KW;contactor Rating 40Amps; MCB(sp) Rating 40Amps complete all as specified and directedMAKE:-Nature switch :Kakatiya energy systems pvt.ltd. hyderabad/bajaj/healer. Contactor:- BCH/L&T/Schneider or equivalent (as per IEC-60947-4-1/IS-13947-4-1), MCBs(Input-output):Hager/schneider/L&T/BCH or equivalent (as per IEC-60898/IS-8828),Circuit wiring : Finolex/polycab/RR Kable or equivalent. Model no SWADEEP-02EC5KW1P. |
| 34 | S&F multi core round PVC insulated aluminium conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 2.5 Sqmm, 3 core from junction box /overhead conductor to street light inside/outside pole complete all as specified and directed |
| 35 | M&L complete earthing with galvanised mild steel earth plate electrode of size 600x600x6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth strip 25 x 4 mm GI Strip by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and galvanised steel tubing as per suitable size and suitable dia for protection of GI Strip upto 7.5 m length fo drawing earth strip protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and directed |
| 36 | M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 50 sqmm 3.5 core complete all as specified and directed |
| 37 | Supply, Install, testing and commissioning feeder pillar out door type fabricated out of 3.15mm thick CRCA sheet dust and vermin proof powder coated double door type, independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed and 300 Amp rated bus bar TPN complete suitable for operating on 415 Volts, 50 Hz AC supply internally wired with copper conductor having legs 90cm made out of 50x 50 x 6 mm angle iron grouted on brick masonary platform upto 45cm. Brick masonay platform should be 60CM above the ground level comprising the following complete all as specified and directed :-(a) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar.(b) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 75cms.(c) Cost of construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC coping 1:2:4 (40mm thick graded stone aggregate), deemed to be included in the item rate. No extra payment will be made.(d) MCCBs should be connected with extensions terminals at both side (incoming and outgoing). |
| 38 | (a) INCOMING |
| 39 | MCCB 4 Pole 415 volts grade 100 Amps rating and 16 KA rupturing capacity -01 No |
| 40 | Voltmeter 0-500 volts, Square 96 mm, flush pattern with 3 way rotary selector switch-01 No |
| 41 | Ammeter size 96 mm, square dial flush pattern having dual range 200 Amps with three way rotary selector switch -01 No |
| 42 | CTs ratio 160/5 class ISI marked sets of three each |
| 43 | Indicating lamp-01 set of three |
| 44 | (b) OUTGOING |
| 45 | MCCB 415 volts grade 63 Amps rating and 16 KA rupturing capacity -02 Nos |
| 46 | M&L for earthing complete with galvanized iron earth plate electrode 600mm x 600 mm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level connecting to and including GI earth strip of size 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit in PCC 1:2:4, type B1, 50mm thick precast RCC 1:2:4 type B-1 cover slab using reinforcement with XPM weighing not less than 1.87 kg/ Sqm with suitable handle made of 12mm end bar, including necessary excavation and earthwork in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 50mm bore light grade galvanised steel tubing upto 5 M length for earth strip protection, including making earth test point, common salt, charcoal, vegitable soil/ cow dung etc complete all as shown in electical plate No 3 of SSR Part-I and testing on completion complete all as specified and directed. |
| 47 | Supply and installation of Solar Water heating system, Racold Flat Plate 8 BAR collector type with heat exchanger of 200 Ltr per day capacity with electrical heating back up complete all as specified and directed. |
| 48 | S&F Hot water pipe duly insulated with glass wool and aluminium cladding of size 20 mm bore complete all as specified and directed. |
| 49 | S&F Hot water pipe duly insulated with glass wool and aluminium cladding of size 15 mm bore complete all as specified and directed. |
| 50 | Supply and Laying in trenches/on wall/on roof GI water tubing of size 25 mm dia medium grade ISI marked with all required fittings such as bends elbows, tees short pieces, connector check nuts & threading required at work site complete all as specified and directed. |
| 51 | S&F Gun metal gate valve ISI marked with iron wheel head screwed both ends for pipe of size 25 mm dia complete all as specified and directed. |
| 52 | S&F Gun metal gate valve ISI marked with iron wheel head screwed both ends for pipe of size 20 mm dia complete all as specified and directed. |
| 53 | M&L PCC (1:2:4) type B2 using 40mm graded stone aggregate for the bottom basement layer of the solar stands complete all as specified and directed. |
| 54 | S&F sheet metal enclosure MCB distribution board, double door with IP-43 IK- 09 protection with metal door single phase 240 volts 4 way, including suitable size copper bus bar and neutral link conf to Cat Pt No 607710 of Legrand or equivalent of make Havells fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. |
| 55 | M&L MCB single pole 240 volts 5 to 40 amps, with rupturing capacity 10 KA using thimbles of required size complete all as specified and directed. |
| 56 | M&L MCB single pole & neutral 240 volts 30 to 63 amps, with rupturing capacity 10 KA using thimbles of required size complete all as specified and directed. |
| 57 | M&L submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FR) of size 10 sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 10 Sqmm as earth lead in & including concealed PVC conduit medium grade cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site complete all as specified and directed. Note : 2 x 10 Sqmm cable & 1 x 10Sqmm cable including PVC conduit shall be measured as one unit. |
| 58 | S&F bib tap 15 mm dia fancy type screwed down for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 59 | S&F Rotational moulded polyethylen water storage tank Capacity 1000 Ltrs (Cylindrical vertical with closed top) hoisted and fixed in position as per SSR Part-II complete all as specified and directed. |
| 60 | S&F angle iron stand made out of 50 x 50 x 6 mm angle iron and 50 x 6 mm flat suitable for stand for Cold water tanks incl painting the stand with two coats of synthetic enemel paint over a coat of red oxide primer complete all as specified and directed. |
| 61 | Schedule of credit amount of Rs 20,950.00 to be deducted during AOC. Please Enable Macros to View BoQ information |