| 1 | Demolition and breaking up 150 mm bore drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed. |
| 2 | Demolition and breaking up 200 mm bore drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed. |
| 3 | Demolition and breaking up 300 mm bore drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed. |
| 4 | Supply, laying & jointing 150 mm nominal bore (Internal diameter) DWC (HDPE Double Wall Corrugated) Pipe, socketed & sewage pipe having 6.00 metre length, conforming to IS : 16098 (Part-II) of SN-4 Stiffness with & including necessary jointing materials etc complete all as specified and directed. |
| 5 | Supply, laying & jointing 200 mm nominal bore (Internal diameter) DWC (HDPE Double Wall Corrugated) Pipe, socketed & sewage pipe having 6.00 metre length, conforming to IS : 16098 (Part-II) of SN-4 Stiffness with & including necessary jointing materials etc complete all as specified and directed. |
| 6 | Supply, laying & jointing 300 mm nominal bore (Internal diameter) DWC (HDPE Double Wall Corrugated) Pipe, socketed & sewage pipe having 6.00 metre length, conforming to IS : 16098 (Part-II) of SN-4 Stiffness with & including necessary jointing materials etc complete all as specified and directed. |
| 7 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 using 20mm grade aggregate smooth finished, and reforming benching as required for 150 mm bore pipe complete all as specified and directed. |
| 8 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 200 mm bore pipe complete all as specified and directed. |
| 9 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 300 mm bore pipe complete all as specified and directed. |
| 10 | M&L for cement concrete bed Type C-2, 1:3:6 (using 40 mm graded stone aggregate) to 150 mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 11 | M&L for Cement Concrete bed Type C-2, 1:3:6 (using 40 mm graded stone aggregate) to 200 mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 12 | M&L for Cement Concrete bed Type C-2, 1:3:6 (using 40 mm graded stone aggregate) to 300 mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 13 | M&L for salt glazed stone ware gully traps size 150 x 150 mm, square or round mouthed, type ‘P’ including setting and jointing to drains with cement mortar 1:1 including demolition of existing traps complete all as specified and directed. |
| 14 | Excavation in trenches in soft/loose soil, not exceeding 1.5 metre wide & not exceeding 1.5 metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan & getting out complete all as specified & directed. |
| 15 | Excavation in trenches in soft/loose soil, not exceeding 1.5 metre wide & exceeding 1.5 metre & not exceeding 3.0 metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan & getting out complete all as specified & directed. |
| 16 | Excavation over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed |
| 17 | Excavation over areas, exc 1.5 m & not exceeding 3m deep and getting out in soft/loose soil complete all as specified and directed |
| 18 | M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled and rammed including watering complete all as specified and directed. |
| 19 | Returning, filling in soft/loose soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified & directed. |
| 20 | Removing surplus excavated material (soil) to a distance exceeding 250 metre but not exceeding 500 metre & depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified & directed. |
| 21 | Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework & precast concrete articles complete all as specified and directed. |
| 22 | M&L for brickwork with old size flyash bricks, straight or curved on plan exceeding 6m mean radius, built in 1:4 cement mortar complete all as specified & directed. |
| 23 | M & L for brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in 1:3 cement mortar complete all as specified and directed |
| 24 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces of wall in CM 1:4 and to be finished even and smooth (without using extra cement) complete all as specified and directed. |
| 25 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces of wall in CM 1:6 and to be finished even and smooth (without using extra cement) complete all as specified and directed. |
| 26 | M&L for preparation of newly plastered or unplastered brick work or concrete surfaces & applying three coatS of white wash on prepared brick work or concrete surfaces complete all as specified and directed. |
| 27 | M&L for providing cement concrete Type B-1, 1:2:4 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, steps; seismic & other similar bands, plinth courses, string courses, lacing courses, parapets & railings upto 60 cm in height, copings, benching, kneelers, apex stones, bed plates, kerbs, water troughs & the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed. |
| 28 | M&L for plain cement concrete Type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 29 | M&L for hardcore of broken stone or boulders of gauge not exc. 63 mm, deposited, spread & levelled in layers not exc. 15 cm thick, watered & rammed to a true surface complete all as specified & directed. |
| 30 | Demolition of cement concrete (unreinforced) of any description & in any position not otherwise specifically provided for complete all specified and directed. |
| 31 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified & directed. |
| 32 | S&F of Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 33 | Demolition of cement concrete (reinforced) of any description & in any position not otherwise specifically provided for. Complete all specified and directed. |
| 34 | M&L for providing precast cement concrete Type B-1, 1:2:4 using 20mm graded stone aggregate in landings, cover slabs (for manholes etc.), chullah hoods, chajjas, water troughs, Hangers, shelves & similar articles with plain faces including necessary chamfers, weatherings, throating etc. & setting in 1:6 cement mortar including necessary formwork if required. Complete all as specified & as directed. |
| 35 | M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; not exc. 200mm thick (Horizontal or sloping) rough finished surfaces of concrete flat complete all as specified and directed. |
| 36 | M&L RCC M-25 reinforced cement concrete using 20 mm graded aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, chajja, deck slabs and in shelves and the like complete all as specified and directed. |
| 37 | S&F of Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with & including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. Complete all as specified and directed. |
| 38 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth, not otherwise described & applying two coats of synthetic enamel paint (ordinary tint) over & including one coat of red oxide, zinc chrome primer complete all as specified and directed. Please Enable Macros to View BoQ information |
| 39 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth, not otherwise described & applying two coats of synthetic enamel paint (ordinary tint) over & including one coat of red oxide, zinc chrome primer complete all as specified and directed. Please Enable Macros to View BoQ information |