| 1 | M & L for Rewinding of burnt windings of Exhaust fans of size 450 mm size including dismantling from loc and removing the burnt out winding , cleaning the stator with CTC solution to remove the burnt slots. Rewinding the same with new super enamelled copper wire same gauge and size /number of turns , varnishing the winding completely and reassembling completely. |
| 2 | M & L for Rewinding of burnt windings of Exhaust fans of size 300 mm including dismantling from loc and removing the burnt out winding , cleaning the stator with CTC solution to remove the burnt slots. Rewinding the same with new super enamelled copper wire same gauge and size /number of turns , varnishing the winding completely and reassembling completely. |
| 3 | M & L for Rewinding of burnt windings of Exhaust fans of size 250 mm including dismantling from loc and removing the burnt out winding , cleaning the stator with CTC solution to remove the burnt slots. Rewinding the same with new super enamelled copper wire same gauge and size /number of turns , varnishing the winding completely and reassembling completely. |
| 4 | supply and fix in replacement Ball bearing suitable for Exhaust fan 450mm sweep any make complete all as specified and directed. |
| 5 | Supply and fix in replacement Ball bearing suitable for Exhaust fan up to 300 mm sweep any make complete all as specified and directed. |
| 6 | Supply and fix in replacement Condensor 2.5 MFD 230 V suitable for Exhaust fan of any sweep/size complete all as specified and directed. |
| 7 | Supply and fix in replacement Condensor 4 MFD 230 V suitable for Exhaust fan of any sweep/size complete all as specified and directed. |
| 8 | Supply and fix in replacement Gun metal Bushings suitable for Exhaust fan of size up to 300 mm sweep any make complete all as specified and directed. |
| 9 | Supply and fix in replacement Gun metal Bushings suitable for Exhaust fan of size up to 450mm mm sweep any make complete all as specified and directed. |
| 10 | Supply and fixing in replacement of exhuast fan any type and size with Plastic body 200 mm sweep including taking down the existing unserviceable exhuast fan and making necessary arrangements for fixing of plastic body 200 mm sweep and connectioning with flexible three core cable from the ceiling rose complete all as directed by the Engineer-in-charge. Mkae: Orient/Bajaj/Usha/Crompton or equivalent |
| 11 | Supply and fixing in replacement of exhuast fan any type and size with Plastic body 250 mm sweep including taking down the existing unserviceable exhuast fan and making necessary arrangements for fixing of plastic body 250 mm sweep and connectioning with flexible three core cable from the ceiling rose complete all as directed by the Engineer-in-charge. Mkae: Orient/Bajaj/Usha/Crompton or equivalent |
| 12 | Supply and fixing in replacement of exhuast fan any type and size with Plastic body 300 mm sweep including taking down the existing unserviceable exhuast fan and making necessary arrangements for fixing of plastic body 300 mm sweep and connectioning with flexible three core cable from the ceiling rose complete all as directed by the Engineer-in-charge. Mkae: Orient/Bajaj/Usha/Crompton or equivalent |
| 13 | Supply and fixing in replacement of air Circulating any type and size with Metal body 450 mm sweep including taking down the existing unserviceable exhuast fan and making necessary arrangements for fixing of metal body 450 mm sweep and connectioning with flexible three core cable from the ceiling rose complete all as directed by the Engineer-in-charge. Mkae: Orient/Bajaj/Usha/Crompton or equivalent |
| 14 | Taking down carefully copper/aluminium point wiring (light, fan, socket and power point) complete fittings such as switches, ceiling rose, regulators, socket etc and removing material from site and making good disturbed surfaces of walls, floors/ceiling to match the existing surface complete all as specified and directed by Engr-in-Charge. |
| 15 | Point wiring complete with 1.5Sq.mm nominal area of copper conductor multi stranded PVC insulated and unsheathed 1100 volts cable drawn through & including PVC Casing & caping with standard accessories such as elbows, tees, junctions etc. and PVC moulded terminal box with top cover of including PVC insulated unsheathed solid 1.5Sqmm copper conductor cable as continuous earth lead all as specified and directed for the followings:- |
| 16 | (a) One light/exhaust fan point controlled by one way switch |
| 17 | (b) One switch socket outlet 6 Amps, 230 volts point on Same board |
| 18 | (c) One switch socket outlet 6 Amps, 230 volts point on independent board |
| 19 | All as item No 15 above, but using cables 4 Sq mm size |
| 20 | Supply and replacement of Switch piano flush button single pole 6 Amps 230 volts one way complete all as directed. |
| 21 | Supply and replacement of switch Socket out let two in one 5 pin 6 Amps flush type.230 volts complete all as directed. |
| 22 | Supply and replacement of switch Socket combination out let multi purpose 5 pin 6 Amps and 16Amps 230 volts complete all as directed. |
| 23 | Supply and fix in replacement of MCB SPN 63 Amp 240 Volts AC ISI marked all as specified and directed by Engr-in-Charge. |
| 24 | Supply and fix in replacement of MCB SP 32 Amps. 240 Volts 50 HZ complete all as directed. |
| 25 | Supply and fix in repair gang box 2 module for mounting of switch and socket fush type 230 volts complete all as directed. |
| 26 | Supply and fix in repair gang box 3 module for mounting of switch and socket fush type 230 volts complete all as directed. |
| 27 | Supply and fix in repair gang box 4 module for mounting of switch and socket fush type 230 volts complete all as directed. |
| 28 | Supply and fix in repair gang box 6 module for mounting of switch and socket fush type 230 volts complete all as directed. |
| 29 | Supply and fix in repair gang box 8 module for mounting of switch and socket fush type 230 volts complete all as directed. |
| 30 | Taking down od unserviceable 15 AMP Gang Box switch socket combination and supply and fix in replacement of switch socket combination out let multipurpopose 5 pin 6/16 Amps with box, 230 Volts complete all as specified and directed. |
| 31 | S &F in replacement in replacement of LED single tube light fitting surface / pendent mounting complete with batten for LED tube light 20 Watt LED Warm white with , extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver.complete all as specified and directed by Engr-in-Charge. |
| 32 | Supply and fix in repair round ultra sleek surface mounted slim aluminium body LED downlight 10 watts complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply and fix in repair square ultra sleek surface mounted slim aluminium body LED downlight 15 watts complete all as specified and directed by Engr-in-Charge. |
| 34 | S & F Plug Top 15 Amps suitable for working on 230 volts 50 Hz AC supply complete all as specified and directed. |
| 35 | S & F Plug Top 5 Amps suitable for working on 230 volts 50 Hz AC supply complete all as specified and directed. |
| 36 | Supply and fix in replacement electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and/or as directed by Engineer-in-Charge. |
| 37 | Supply and fix in replacement electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all specifed and/or directed by Engineer-in-Chrage. |
| 38 | S &F in replacement in replacement of sheet metal enclosure with socket plug top and MCB single pole and neutral with two pin and earth plug with one SP MCB 20 Amp 240 volt complete all as directed. |
| 39 | S &F in replacement of geyser assembly suitable for water heater of capacity upto 25 Ltrs to fix thermostat , heating element as of the existing model & size including all clamps with bolts and nuts etc . |
| 40 | Taking down water heater storage type cap 25 Ltr of any make Vertical/horizontal type after disconnecting the electric/ water connections and dismantling the heating elements / geyser assy and descaling with de scaling solutions and replacement of gaskets suitable for resisting 98 degree temp /nut bolts etc all as directed and testing the safety devices and reinstalling at same location complete all as specified and directed by Engr in Charge. |
| 41 | Taking down water heater storage type cap 50 Ltr of any make Vertical/horizontal type after disconnecting the electric/ water connections and dismantling the heating elements /geyser assy and descaling complete with de scaling solutions and replacement of gaskets suitable for resisting 98 degree temp /Nut bolts etc all as directed and testing the safety devices and reinstalling at same location complete all as specified and directed by Engr in Charge. |
| 42 | Taking down water heater storage type cap 100 Ltr of any make Vertical/horizontal type after disconnecting the electric/ water connections and dismantling the heating elements /geyser assy and descaling complete with de scaling solutions and replacement of gaskets suitable for resisting 98 degree temp /nut bolts etc all as directed and testing the safety devices and reinstalling at same location complete all as specified and directed by Engr in Charge. |
| 43 | S &F in replacement in replacement of water inlet/outlet assy suitable for storage water heater of 25 Ltrs capacity having provn of housing thermostate, heating element including providing rubber gaskets and holding nut bolts etc complete. |
| 44 | S &F in replacement in replacement of water inlet/outlet assy suitable for storage water heater of 50 Ltrs capacity having provn of housing thermostate, heating element including providing rubber gaskets and holding nut bolts etc complete. |
| 45 | S &F in replacement in replacement of water inlet/outlet assy suitable for storage water heater of 100 Ltrs capacity having provn of housing thermostate, heating element including providing rubber gaskets and holding nut bolts etc complete. |
| 46 | S &F in replacement in replacement of thermostate switch for water storage heater suitable for Racold/ Pearl / orison type or equivalent 220/240V 50HzAC temperature range 32 - 88 degree centigde ISI marked complete. |
| 47 | S &F in replacement in replacement of heating elements suitable for water storage heater vertical type RACOLD/ORISON/PEARL or equivalent 220/240 V AC 1500W and making connections and testing complete. |
| 48 | S &F in replacement in replacement of heating elements suitable for water storage heater vertical type RACOLD/ ORISON/PEARL or equivalent make 220/240 V AC 2000W and making connections and testing complete. |
| 49 | S &F in replacement of heavy duty PVC connections armored type with brass union ,nut, heat resistance type rubber washer for hot water complete. |
| 50 | S &F in replacement in replacement of Indicating lamps suitable for storage water heater any type & cap complete. |
| 51 | Takingn down old unservicecable heating pillar rod of any make and capacity & supply and fix in replacement heating pillar rod as existing upto 2000 watt, 230 Volts complete all as specified and directed by Engr-in-Charge. |
| 52 | S &F in replacement stainless steel tank of capacity 25 ltr as per sample complete all as specified and directed by Engr in Charge. |
| 53 | S &F in replacement stainless steel tank of capacity 50 ltr as per sample complete all as specified and directed by Engr in Charge. |
| 54 | S &F in replacement stainless steel tank of capacity 100 ltr as per sample complete all as specified and directed by Engr in Charge. |
| 55 | Deduct Schedule of Credit of Rs (-) 33625.00 (Minus) as listed in Schedule 'A' (Contd). Contract Sum shall be arrived after deducting the credit amount.Note :- Tenderers will not quote against this item being a firm amount. Please Enable Macros to View BoQ information |