|
| 1 | Demolition of cement concrete in ground floor and pavings n.exc 15cm thick below or above ground level and removing demolised material out of Military station complete all as specified and directed. |
| 2 | Demolition of unreinforced cement concrete in any description and any position not otherwise specifically provided for complete all as specified and directed. |
| 3 | Dismantling chain link fencing/expanded metal or mesh exceeding 4kg/Sqm fixed in steel, wood fillets, concrete post etc. of any description complete all as specified and directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 5 | Demolition of precast concrete block walling, stone/boulder masonry built in cement mortar including all quoins, arches , pillars etc all as specified and as directed. |
| 6 | M&L pre-cast cement concrete (20mm graded crushed stone aggregate) 1:3:6 type C-1 as in block masonery exc 10cm in width with solid block masonery with solid blocks, exc.10cm in width and setting in cement mortar 1:6 complete all as specified and directed. |
| 7 | Ditto All as per item no 6 but except blocks complete all as specified and directed. |
| 8 | M&L for walling of random rubble, uncoursed stone masonary, well bonded, bedded solidly hearted, built in CM 1:6 complete all as specified and directed. |
| 9 | -ditto- All as per item no 8 but except stones complete all as specified and directed. |
| 10 | Extra over stone walling for hammer dressing for lime sand stone n'exc 40mm deep when held against edge complete all as specified and as directed. |
| 11 | Taking down cement plaster on brick or concrete surfaces including racking out joints hacking for key, scrubbing down with water etc. complete all as specified and as directed. |
| 12 | M&L for 10mm thick rendering on fair faces of brick works finished even and smooth without using extra cement in cement mortar 1: 4 complete all as specified and as directed. |
| 13 | M&L for 15 mm thick rendering on other than faces of stone masonry works finished even and smooth without using extra cement in cement mortar 1: 4 complete all as specified and as directed. |
| 14 | M&L for preperation of new plastered wall surface of any description and applying two coat of cement based paint over a coat of chalk whiting complete all as specified and as directed. |
| 15 | M & L Preparing newly plastered surfaces and applying two coats of distemper oil emulsion including priming plastered and other surfaces with alkali resistant priming paint on surfaces of walls. |
| 16 | Supply only integral liquid water proofing compound complete all as specified and directed. |
| 17 | Raised pointing to random or polygonal rubble, uncoursed block walling in CM 1:4 complete all as specified and as directed. |
| 18 | Demolition of bricks (laid flat or on edge) or interlocking tiles in floors, channels, kerbes, aprons, etc laid dry of laid dry and pointed complete all as specified and directed. |
| 19 | Demolition of stone slabs and tiles of any description or thickness in floors aprons etc.laid bedded and pointed in any mortar complete all as specified and directed. |
| 20 | M&L for Cement concrete type D-2,1:4:8 (40mm graded aggreate) 75 mm thick as in sub -floors ,sub- bases ,floors and pavings, etc. complete all as specified and directed. |
| 21 | M&L machine pressed precast concrete interlocking paver block any shape and size polished with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickiness M-35 grade complete all as specified and as directed by Engr-in-Charge. |
| 22 | M&L sand filling (50 mm average thickness) under floors in foundations and for laying Interlocking paver blocks including watering and consolidation complete all as specified and as directed by Engr-in-Charge. |
| 23 | M&L for Cement concrete type D-2,1:4:8 (40mm graded aggreate) 75 mm thick as in sub -floors ,sub- bases ,floors and pavings,etc. complete all as specified and directed. |
| 24 | M&L for Chequred cement concrete tiles 20cm X 20cm X 25mm thick, set, pointed & jointed in neat cement slurry in floors polished with grey cement & pigments layed over 20mm thick cement screed bed in CM (1:6) and all as directed by Engr-in - charge. |
| 25 | M & L for 75 mm PCC 1:2:4 type B-1 using 20mm graded aggregate as plinth protection finished even and smooth with out using extra cement complete all as specified and directed. |
| 26 | M&L for cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement percubic metre, thickness of concrete 25 cm or less complete all as specified and directed. |
| 27 | Supply only metalic floor harderner. |
| 28 | M&L forming contraction (Dummy) joint 65mm deep x 10mm wide filled with sealling compound grade 'A' complete all as specified and directed. |
| 29 | M&L 100mm Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ complete all as specified and directed. |
| 30 | M&L for PCC type D-2(1:4:8) using 40mm graded crushed aggregate as mass conc and filling of foundation all as specfed and drected. |
| 31 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 32 | Excavating in post holes hard/dense soil (of similar holes) each n. exc. 0.50 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering and removing surplus soil to a distance n. exc. 50m and making good surface complete all as specified and directed. |
| 33 | S&F angle iron with swain neck as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc, hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engr-in-charge. |
| 34 | M&L for PCC type C-2, (1:3:6), using 40mm graded crushed stone aggregate as in lean conc, sub base, or mass conc, foundation filling etc. complete all as specified and directed. |
| 35 | Fixing only Chain link fencing including line wires, any mesh size and type to any type of standards,rails, straining bolts, etc. including provision of binding wire complete all as specified and directed. |
| 36 | Supply only chain link MS galvanised fencing of size as directed by Engr-in-Charge. |
| 37 | Dismantling of old barbed wire and making rolls including stacking neatly complete all as specified and directed by Engr-in-Charge. |
| 38 | S & F Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed. |
| 39 | S&F mild steel screw bolt 5 to 10 mm dia (machine made) with hexagonal head at one end and screwed the other, screwed end to be fitted with one waher and hexagonal nut length exc 5cm but not exc 10 cm long. |
| 40 | Preparation of newly or previously untreated steel surfaces, of any description, over 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 41 | Dismantling plain or corrugated steel sheeting any gauge thickness including nanital or similar pattern complete all as specified and directed. |
| 42 | S&F 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 complete all as specified and directed. |
| 43 | Ditto all as item No 42 above but except sheeting complete all as specified and directed. |
| 44 | S&F 0.63mm thick Plain, galvanised, mild steel sheeting, in ridges,hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed. |
| 45 | S & F Pre-painted galvanum aluminum zink coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550MPa as in roof covering /clading to walls fixed with self tapping screws complete all as specified and directed. |
| 46 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 47 | S&F Fibre glass reinforced translucent plain sheeting 2mm thick with two corrugations side lap fixed with coach screw and washer in roof ,wall etc complete all as specified and as directed |
| 48 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed. |
| 49 | S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, Fe 410, Gde E-250 quality- A complete all as specified and directed. |
| 50 | Deduct Schedule of Credit of Rs (-) 100405.00 (Minus) as listed in Schedule 'A' (Contd). Contract Sum shall be arrived after deducting the credit amount.Note :- Tenderers will not quote against this item being a firm amount. Please Enable Macros to View BoQ information |