| 1 | Dismantling /Taking down carefully copper/Aluminium point wiring (Light, Fan, Socket or power) complete including fixtures and fittings such as switches, ceiling, regulator, sockets etc and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engr-in-Charge. |
| 2 | M&L for point wiring with copper conductor cable, multistranded, single core 1.5 Sqmm size for one light/exhaust point controlled by one switch with PVC insulated multistranded and unsheathed 1100 volts copper conductor cable of size 1.5 sq mm for earth continuity in and including PVC casing and capping of approved size and quality fixed on walls/ceiling/wooden panelling including 2 to 18 modular sunken/plastic box with cover plate and frame complete all as specified and directed by Engr-in-Charge. Make of cable: As per PS, Make of casing caping |
| 3 | All as per Item No 2.00 here-in-above but for one 3 pin socket outlet, 5 Amps, 230 volts on the same board with other switches, with cables 1.5 Sqmm size complete all as specified and directed by Engr-in-Charge. |
| 4 | All as per Item No 2.00 here-in-above but for one 3 pin socket outlet, 5 Amps, 230 volts Independent board and box with the cable 1.5 sqmm size complete all as specified and directed by Engr-in-Charge. |
| 5 | All as item No. 2.00 here-in-above but using cables 2.5 Sqmm, along with earthing cablel of 2.5 sqmm copper conductor for one 3/5 Pin Socket outlet 15 Amps & 5 Amps, complete all as specified and directed by Engr-in-Charge. |
| 6 | S&F switch one way 6 Amp , 230 volts, 50 HZ supply complete all as specified and directed by Engr-in-Charge. |
| 7 | S&F switch one way 16 Amp, 230 volts , AC Supply complete all as specified and directed by Engr-in-Charg. |
| 8 | S&F for switch socket outlet 6 Amps, 2/3 pin combined 2 module 230 volts complete all as specified and directed by Engr-in-Charge. |
| 9 | S&F switch socket outlet 6 /20 Amps, 3 pin combined 2 module 230 volts complete all as specified and directed by Engr-in-Charge. |
| 10 | S&F in replacement Modular switch , bell push, 6 amps one module , 230 volt , 50 Hz supply complete all as specified and directed by Engr-in-Charge. |
| 11 | S&F in replacement Modular blanking plate 1 module complete all as specified and directed by Engr-in-Charge. |
| 12 | S&F in replacement for ceiling rose surface bakelite 65x50 mm two to three terminals all as specified and directed by Engr-in-charge. |
| 13 | S&F in replacement for lamp holder PVC/Poly corbonate type insulated body with back plate suitable for batten fittings complete all as specified and directed by Engr-in-Charge. |
| 14 | S&F in replacement for door Bells electric Ding- dong/ musical type single phase 230Volts complete all as specified and directed by Engr-in-Charge. |
| 15 | Supply and fixing in replacement of sheet metal enclosure SP with two pin and earth plug and socket including metal clad to with one single pole MCB 20/32 Amps complete all as specified and directed by Engr-in-Charge. |
| 16 | S&F in replacement of LED light fittings 1x20 watt, 240 volts AC, decorative box type with driver, holder including 20 W LED tube lights suitable for roof ceiling including connecting up with three core copper flexible conductor cable of sutable size complete all as specified and directed by Engr-in-Charge. |
| 17 | Supply and fix in replacement batten type with surface mounted LED tube light fitting with high efficient diffuser mirror light, polycarbonate housing in CRCA body suitable and including 10 watt LED tube rod high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed by Engr-in-Charge. |
| 18 | Supply and fix in replacement bulk head light fitting, 10 watt, energy efficient with lamp 10 watt with provision of 2/3 core PVC copper conductor cable 0.5 Sqmm size from ceiling rose to light fitting complete including disconnecting and taking down old existing light fitting of any description complete all as specified and directed by Engr-in-Charge. |
| 19 | Supply and fix inverter LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed by Engr-in-Charge. |
| 20 | Supply and fix in replacement of recess/ surface mounted LED flat panel 2' x 2' CRCA powder coated, 36 watt, IP20 with provision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed by Engr-in-Charge. |
| 21 | Supply and fix in replacement of Inverter LED tube light fitting 1x20 Watt with minimum 04 hours battery back up integrated aluminium batten with diffuser and including 20 Watt LED hight efficient , AC 220-240 V, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed by Engr-in-Charge. |
| 22 | Supply and fix in replacement inverter LED bulb B-22 cap with opal diffuser, IP20 and inbuilt battery back up of 10 Watt capacity all as complete all as specified and directed by Engr-in-Charge. |
| 23 | Material and labour for sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 2.5 sqmm drawn in and including rigid non metallic PVC medium grade 20 mm dia New concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 2.5 sqmm,green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE: - 3 run of 2.50 sqmm cable with concealed conduct shall be measured as 1 unit complete all as specified and directed by Engr-in-Charge. |
| 24 | Material and labour for sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable6.0 sqmm drawn in and including rigid non metallic PVC medium grade 20 mm dia New concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 2.5 sqmm,green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE: - 3 run of 6.0 sqmm cable with concealed conduct shall be measured as 1 unit complete all as specified and directed by Engr-in-Charge. |
| 25 | All as per Item No 24 above but for Material and labour for sub main wiring of 4.00 sqmm. NOTE:- 3 run of 4.0 sqmm cable with concealed conduct shall be measured as 1 unit complete all as specified and directed by Engr-in-Charge. |
| 26 | Supply and fixing in repair sheet metal enclosures vertical distribution board VTPN,(MCCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and including MCCB 4 pole thermal release type ,125AMPS ,25 KA with seperator as incomer and MCB s as out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs and making good the disturbed surface matching with existing surface complete all as specified and directed by Engr-in-Charge. |
| 27 | All as per Item No 26 above but VTPN DB alongwith MCCB 4 pole,100AMPS 16 KA with seperator as incomer and MCB s as out going complete all as specified and directed by Engr-in-Charge. |
| 28 | Supply and fixing in repair SPN distibution board 8 way, double door, IP 43, as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles /gland/gaskets complete all as specified and directed by Engr-in-Charge. |
| 29 | Supply and fix in replacement of sheet metal enclosure for DBs double door when MCB's to be used single pole & neutral 240 Volts 4 Ways all complete all as specified and directed by Engr-in-Charge. |
| 30 | Supply and fix in replacement of sheet metal enclosure for DBs double door when MCB's to be used single pole & neutral 240 Volts 2 Ways all complete all as specified and directed by Engr-in-Charge. |
| 31 | Supply and fixing in repair MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'C' curve 6 to 32 Amps, ISI complete all as specified and directed by Engr-in-Charge. |
| 32 | Supply and fixing in repair MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'C' curve 40 to 63 Amps, ISI marked complete all as specified and directed by Engr-in-Charge. |
| 33 | Supply and fixing in repair MCB single pole, and Neutral 240 volts, 50Hz , breaking capacity 10KA, 'C' curve 40 to 63 Amps, ISI complete all as specified and directed by Engr-in-Charge. |
| 34 | Supply and fix in repair MCCB four pole 415 volts, 160 Amps,25KA, 50 Hz, along with seperator thermal release adjustable type with upto 70% complete all as specified and directed by Engr-in-Charge. |
| 35 | Supply and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable circular type of size 10 Sqmm including all incoming and outgoing connection with proper size of thimble complete all as specified and directed by Engr-in-Charge. |
| 36 | All as per Item No 35 above but one twin core cable circulr at of size 16 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 37 | Material and labour for taking down existing lighting fiting any type/size/Make/capacity i.e T/L, Surface/ Recess Panel, flame proof, wall light, bulk head, mirror light etc and re-fixing the same after minor repair/cleaning including replacement connection wire with suitable size coper wire twin core 0.75 sqmm for connection from ceiling rose to light fitting complete all as specified and directed by Engr-in-Charge. |
| 38 | Supply and fixing PVC insulated, unsheathed cable 2.5 Sqmm single core 1100 volt grade with multi stranded copper conductor complete all as specified and directed by Engr-in-Charge. |
| 39 | Supply and fixing Cable PVC copper conductor flexible twin core 0.75mm complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 40 | Supply and fixing Cable PVC copper conductor flexible twin core 0.75mm complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |