| 1 | NOTE: Schedule ‘A’ Part - I to Part -X are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. |
| 2 | Total amount of Sch 'A' Part - I (BUILDING Works) |
| 3 | Total amount of Sch 'A' Part - II (SITE CLEARANCE WORKS) |
| 4 | Total amount of Sch ‘A’ Part - III (INTERNAL WATER SUPPLY) |
| 5 | Total amount of Sch ‘A’ Part - IV (INTERNAL ELECTRIC SUPPLY)) |
| 6 | Total amount of Sch ‘A’ Part - V (PROTECTIVE WORKS) |
| 7 | Total amount of Sch ‘A’ Part - VI (ROAD, PATH & HARDSTANDING WORKS) |
| 8 | Total amount of Sch ‘A’ Part - VII (SEWAGE DISPOSAL) |
| 9 | Total amount of Sch 'A' Part - VIII (EXTERNAL ELECTRIC SUPPLY WORKS) |
| 10 | Total amount of Sch ‘A’ Part -IX ( EXTRNAL WATER SUPPLY WORKS) |
| 11 | SCH 'A PART - X (Miscellaneous B/R and E/M works for Sch 'A' Part-II to Part-IX)Note: This schedule is not pre-priced by MES and the rate indicated as \\"Rs 0.00\\" under Col 5 signifies this fact only |
| 12 | Supply and fixing LED mirror light fitting 10 watt, cool/warm white and making all electric connections complete all as directed. |
| 13 | Supply and fixing of LED tube light fitting, 20 watt. with and including all electric connections complete all as specified and as directed. |
| 14 | S&F PVC ventilatiing fan 250mm sweep 230 volt AC with & including louvers and all fixing arrangements complete all as specified & directed. |
| 15 | Supply and fixing of LED security light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 16 | Supply and fixing of security light fitting bracket, 1 mtr long made out of galvanized iron pipe of 25 mm dia size light grade bent to shape complete with nut, bolts, washer etc inclusive of one primer coat, one under coat and one finishing coat of silver paint complete all as specified and directed. |
| 17 | Supply , Fixing and of 1200 Litrs capacity LLDP septic tank in along with inlet, outlet, vent, internal piping, manhole cover, plastic media and all civil works like PCC of 150mm at base of pit, back filling work with sand and excavation complete all as specified and directed. |
| 18 | Supply , Fixing and of 1200 Litrs capacity LLDP septic tankalong with inlet, outlet, vent, internal piping, manhole cover, plastic media and all civil works like PCC of 150mm at base of pit, back filling work with sand and excavation complete all as specified and directed. |
| 19 | M&L for 200 (OD)/170(ID) mm diameter DWCPE (SN8) pipes, lid and jointed in trenches on concrete bed and jointed complete, all as specified. |
| 20 | Supply, fix and testing Self regulating Heat Tracer 35 W to be used on Water Supply pipeline where ever it is in undulating terrain, exposed to environment and at less depth than frost line with connection to panel and electric wire of size 10 Sqmm, 2 core pasted properly with Aluminium Adhesive tape complete all as specified and as directed. |
| 21 | Supply and fixing Connection panel cum temperature controller to regulate electric supply to the Heat Tracer Cable 65 W to maintain temp to the water supply pipeline laid underground and to the exposed pipeline and connecting to the LT Supply complete all as specified and as directed. |
| 22 | Supply & fixing including connecting, commissioning and testing of factory Made (Automatic and Manual operation) power factor improvement panel of suitable size of capacity 60 KVAR including interconnection with LT panel with & incl 2 Run of 185 Sqmm 3.5 Core aluminium electric cable of suitable length as per site requirement for transformer. Indoor type panel factory made, weather proof , dust and vermin proof (IP 55) suitable for 440 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 2mm CRCA sheet mounted chanel frame made out of 50X50X6 mm, 450 cm long angle iron below frame with front door and Back opening having locking arrangement on both sides prewired with copper conductor PVC insulated flexible wire size not less than 1.5 sq mm / extension strips and connected with suitable size copper thimbles / lugs duly painted with siemens grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:2:4 type B-1 [using 20 mm graded crushed stone aggregate] of suitable size including locking arrangement on both sides suitable for mounting , with required sheet metal enclosures, thimbles etc. complete all as specified and directed by Engr-in-Charge & drawing of panel should be approved by GE |
| 23 | Incommer MCCB 125 Amp , Three Pole, Thermal based release with adjustable O/L ,Adj S/C Setting 36KA rupturing capacity, Ics=100%Icu, - 1 No Make: L&T/ Schneider/legrandMetering Section- Multifunctional meter having voltmeter , current , frequency,with 3x2A SP MCB, 3 x indicators RYB-01 No,CT shorting link/ Netural link.nsulated Busbar of Aluminium of 200A Capacity for 3 phase,, fixed on Insulators, Busbar shall be PVC Sleeved with red / Yellow/ Blue Colour, Busbar Support shall be of SMC/DMC - 1 set.7 Steps Three Phase Automatic Power Factor controller steps Relay Micro proccessor based for switchting ON and OFF of capacitors to Display of voltage ,current,Active power ,apparent Power display of COS Ø ,THD voltage ,THD current, alarm indication for defective step,low power factor and excess temperature.The relay having volt free c/o contact,automatic detection and uses of optimum capacitor capable of 4 Quadrant operation and any phase offset requirement.Switching programm :LIFO combi Filter ,manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 440 volt ,45 to 65 HZ,current measuring 10MA-5A suitable for CT x/1A and x/5A commissing without additional setting and programming.Three decimal power reading .Phasing out of fault capacitor bank Automatically Accessories for 2 KVAR Capacitor Bank - 1 No :- Capacitor Duty Contactor 2 KVAR with Damping Resistors which limits inrush current , 3phase , 50 hz , coil-220VAC ,MCB TP 20A having breaking capacity 10 KA with dieelctric type capacitor rated Voltage 440Volt 50 Hz,, on indicators and selector switch |
| 24 | Accessories for 3 KVAR Capacitor Bank - 1 No :- Capacitor Duty Contactor 3 KVAR with Damping Resistors which limits inrush current , 3phase , 50 hz , coil-220VAC ,MCB 20A TP having breaking capacity 10 KA with dieelctric type capacitor rated Voltage 440Volt 50 Hz,, on indicators and selector switchAccessories for 5 KVAR Capacitor Bank - 1 No :- Capacitor Duty Contactor 5 KVAR with Damping Resistors which limits inrush current , 3phase , 50 hz , coil-220VAC ,MCB 20A TP having breaking capacity 10 KA with dieelctric type capacitor rated Voltage 440Volt 50 Hz,, on indicators and selector switchAccessories for 10 KVAR Capacitor Bank - 2 No :- Capacitor Duty Contactor 10 KVAR with Damping Resistors which limits inrush current , 3phase , 50 hz , coil-220VAC ,MCB TP 20A having breaking capacity 10 KA with dieelctric type capacitor rated Voltage 440Volt 50 Hz,, on indicators and selector switchAccessories for 15 KVAR Capacitor Bank - 2 Nos :- Capacitor Duty Contactor 15 KVAR with Damping Resistors which limits inrush , 3phase , 50 hz , coil-220VAC ,MCB TP 32 A having breaking capacity 10 KA with dieelctric type capacitor rated Voltage 440Volt 50 Hz,, on indicators and selector switch |
| 25 | Supply & fixing including connecting, commissioning and testing of factory Made LT panel Indoor type panel factory made, weather proof, dust and vermin proof (IP 54) , fabricated out of 3.15 mm CRCA sheet mounted Angle iron base frame made out of 50 mmX 50 mm X 6 mm, 450 cm long angle iron below frame with front door and Back opening having locking arrangement on both sides prewired with copper conductor PVC insulated flexible wire size not less than 1.5 sq mm / extension strips and connected with suitable size copper thimbles / lugs duly painted with siemens grey epoxy powder coating after suitable chemical treatment, legs duly embedded in ground in PCC 1:2:4 type B-1 [using 20 mm graded crushed stone aggregate] of suitable size including locking arrangement on both sides suitable for mounting, with required sheet metal enclosures, thimbles etc. complete all as specified and directed & drawing of panel should be approved by GE |
| 26 | Incommer MCCB 250 Amp , FP, Thermal based release with adjustable O/L ,Adj S/C Setting 36KA rupturing capacity, Ics=100%Icu, - 2 NosMetering Section- Multifunctional meter having voltmeter , current , frequency,with 3x2A SP MCB, 3 x indicators RYB-01 No,CT shorting link/ Netural link.Insulated Busbar of Aluminium of 250A Capacity for 3 phase,, fixed on Insulators, Busbar shall be PVC Sleeved with red / Yellow/ Blue Colour, Busbar Support shall be of SMC/DMC - 1 set.Outgoing MCCB 160 Amp , FP, Thermal based release with adjustable O/L ,Adj S/C Setting 25KA rupturing capacity, Ics=100%Icu, - 3 NoOutgoing MCCB 40 Amp , FP, Thermal based release with adjustable O/L ,Adj S/C Setting 16KA rupturing capacity, Ics=100%Icu, - 1 NoOutgoing MCCB 32 Amp , FP, Thermal based release with adjustable O/L ,Adj S/C Setting 16KA rupturing capacity, Ics=100%Icu, - 1 NoON LOAD change over switch 415V,FP,200 AmpsVFD for openwell Submersible pump 12.5HP 2NoVaccume Motor starter 1HP 1NoMCB 16 Amp , SPN,10KA - 2 No |
| 27 | M & L for Boring of hole under road pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as spd and directed. |
| 28 | Supply and laying ductile Iron pipe of size 100 mm dia centrifugally casted with spigot and socketed ends confirming to IS-8329/2009 ( class K-9) in standard length for classification suitable for push on joint(Rubber packing D jointing) cement mortar lining inside the pipe and zinc coating with bituminious paint on outer side as per IS 8329/2000 including all fittings rubber packing etc complete all as specified and directed. Note:- (i) The rate quoted is deemed to be inclusive of ground lowering and Tyton Joints. (ii) Rubber gasket (tyton joint) should be of EPDM quality confirming to IS:5382/1985. (iii) Excavation and Earth Work shall be measured and paid separately. |
| 29 | All as per Srl No. 24 above but ductile iron pipe of size 80 mm dia, class K-9 complete all as specified and directed. |
| 30 | S & F DI bends (any type radius and angle) tapers any type, (straight, bend, increasing, decreaing or double socket etc) tee pieces single branch, \\"Y\\" junction double branch, cross (all socket or socket not spigot) collars, caps and plugs upto 100mm bore complete all as specified and as directed. |
| 31 | Supply and fix CI DOUBLE ORIFICE AIR VALVE RUBBER BALL 50 MM with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains . Note: The Air Valve will be fixed above ground i.e. 1.6 m through a connecting pipe to avoid freezing and heat tracer cable to be wrapped around. complete all as specified and directed. |
| 32 | Material and labour for valve size pit of size 90cm x 90cmx 180cm (internal dimensions), stone masonry construction including all necessary excavation and earth work in any type of soil returning filling in disposal of surplus spoil to a distance not exceeding 50m and depositing where directed, PCC in foundation of the mix (1:4:8), type D-2 (using 40mm graded crushed stone aggregated, stone masonry in cement mortar (1:4) rendering, 12mm thick in cement mortar (1:4), externally as the work frame, MS sheet cover 3.15mm thick with handle and locking arrangement, painting all the exposed MS work with two coats of synthetic enamel paint of the tint as approved by the GE over a coat of red oxide primer and painting all the M.S embedded in PCC with two coats of black bituminous paint suitable for 80mm dia, complete all as specified and shown on drawing. |
| 33 | Supply and fixing insulation for tubing of size suitable for 100mm dia pipe and 32mm thick, conductivity suitable for temperature range of (-)40ºC to (+)40ºC and class-0 fire resistance, water vapour permeability > 7000 and CFC free complete all as specified and directed. |
| 34 | All as per item No 29.00 above but insulation tubing of suitable for 80 mm dia and 32mm thick |
| 35 | All as per item No 29.00 above but insulation tubing of suitable for 50 mm dia and 25 mm thick |
| 36 | All as per item No 29.00 above but insulation tubing of suitable for 40 mm dia and 25 mm thick |
| 37 | All as per item No 29.00 above but insulation tubing of suitable for 25 mm (OD) dia and 19 mm thick |
| 38 | M&L for Metal Clading : Providing and fixing of aluminium cladding of 0.32 mm thick Aluminium Sheet on insulated pipes 40 mm dia (for exposed pipes only) but, 50-40 mm dia pipe (for exposed pipes only) |
| 39 | All as per item No .34.00 above but, 25 mm dia PPR pipe (for complete pipe) |
| 40 | Supply, installation, testing, and commissioning of Open well Submersible pump set with IP 44 protection, operating voltage 380 to 440V, having capacity 308.33 LPM at 51.74 mtr Head (12.5 HP) after considering derating factor for 3248 mtr from MSL complete having Suction pipe size 80 mm and delivery pipe 80 mm size all as specified and directed. (01W + 01S) |
| 41 | Supply, installation, commissioning and testing of fully automatic oil fired hot water generator capable of delivering a heat output 50000 Kcal/Hr using HSD oil, Smoke Tube complete with combustion chamber and equipment automatic monoblock burner assembly tubes, control panel with sequence controller, photo cell for flame failure, HT transfer electrodes, blower assembly, electric panel, mounting frame, pressure gauges at inlet and outlet, High Temp. Cutout For Water Flue Gas, Pressure relief Valve, Complete Insulation & Cladding as Per Manufacturing Standard suitable for operation on 50 HZ, 3 phase 415 Volts A C supply. (Including standard size of Duct, Bend and Chimney, One: Fuel Oil tank, One Set: Fuel Oil piping between filter and burner).(1) Hot water inlet temp.= 65 C˚, (2) Hot water outlet temp.= 75 C˚(3) Hot water pump 02 Nos (One working + One standby) of 5000 Ltr/Hour Flow at 15 Mtr head with mechanical seal, suitable size cabling from main panel, control panel etc, water valves as NRV, Butterfly valves, Y strainer, internal piping from Hot water generator to pump duly insulated as per norms complete all as required as site.(4) 5mm chimney with self standing for oil fired hot water generator as per norms. |
| 42 | Supply and Fix Vacuum pump 1 HP motor Capacity 15 cum/hr with suction and delivery assembly for pumping of water from pipe line all as specified and directed. |
| 43 | Supply and fix submersible copper conductor cable 3 core, 16 sqmm 1100 volt flat including nylon binding wire and accesories to clamp with column pipe at two places to each column pipe.complete all as specified and directed. |
| 44 | Drilling of Trail Bore Hole 200 mm (8 inch) dia from ground level to 100 meter in any strata by ODEX / DTH METHOD method as per IS : 2800 1979 (revised and amended) below ground level through any kind of strata soils/rocks, disposal of surplus soil within a distance of 100 m, well rammming and stablizing of material , transportation of drilling Rig and other T&P required, keeping space for pea gravel packing in and including lowering and extraction of casing pipes of suitable thickness after lowering of designed assemble of EWR pipe complete all as specified and as directed. |
| 45 | Notes:- (i) ERW housing pipes shall be measured and paid seperately. (ii) Casing pipe alongwith direct rotary drill Pipes with with tools shall be arranged by the contractor and the same shall remain property of contractor after extraction. (iii) In case of non extraction of casing pipe during the course of drilling any type of mishappening, any type of fishing operation of failure of bore well the contractor will have no claim what so ever on this account.(iv) Third trial bore shall only be carried out in case the first and second trial bores respectively are declared to be unsuccessful by the GE in writing. (v) Depth of second and third trial bores may vary if suggested by CGWB. Contractor shall have no claim on account of reduction or addition in the depth. (vi) Payment of unsuccessful trial bore(s)shall only be released after successful boring in the successive trial. However in the event of unsuccessful boring even after 3 Nos. of trial bores if it is decided to be given up, the site will be abandoned and payment for all the trial bores will be allowed only after approval of Accepting Officer. (vii) Rate applicable for payment of the second and third trial bore shall be 20% less than the rates quoted against 1st trial bore. |
| 46 | Enlargement of borehole from 200 mm to 500 mm from Ground Level to 120 mtrs complete all as specified and as directed. NOTES:- (i) The rate for development of trial bore beyond 120 mtr depth, if ordered by GE depending upon the CGWB recommendation or the basis of the Electrical logging Report, will be admissible at the rater of this Item. (ii)The note is applicable for Srl item No 40 verticality Test of the Tube-Well Structure shall be carried out by the contractor and the cost is deemed to be included in the Item rate. |
| 47 | Supplying, assembling including lowering and fixing liner assembly or strainer etc in position (net affective length shall only measured and paid) all as specified below:- |
| 48 | Mild steel ERW bevelled end pipe 200 mm (08 inch) nominal bore having min 8 mm wall thickness confirming to IS:4270-2001 and all around welded with 03 Nos stiffeners of flat iron 75x8mm, 150 mm long, complete all as specified ans as directed. |
| 49 | Mild steel ERW bevelled endslotted housing pipe nominal bore 200 mm (08 inch) nominal bore having min 8 mm wall thickness confirming ti IS:4270-2001 having slot size of 1.6 mm x75 mm as per (IS:8110:2000) and all around welded with 03 Nos stiffeners of flat iron 75x8 mm, 150 mm long, complete all as specified ansd as directed. |
| 50 | Supply and fixing in position MS housing pipe clamps made of MS flat of size 100 mmx 12 mm and 750 mm long for 200 mm (08 inch) bore pipe with suitable bolts, nuts and washers all as specified and as directed. |
| 51 | Supply and fixing in position mild steel well cap fabricated out of 8 mm thick MS sheet having an internal threading and locking arrangement for 200 mm dia pipe in two pieces having 100 mm x 8 mm thick complete with nuts, bolts and washers etc including painting over a coat of Red oxide primer complete all as specified and directed. |
| 52 | Supply and filling Pea gravel of Size 2 mm to 6 mm around the liner assembly from bottom to ground the level including continous watering during development complete all as specified and as directed. |
| 53 | Flat Iron of size 50 x 6 mm as centre guides of required size including welding to casing pipe complete all as directed. |
| 54 | Supply and fixing MS casing shoe (to be welded with MS ERW casing pipe of 200mm nominal bore) suitable for DTH ODEX drilling complete all as specified and directed. |
| 55 | Development of borewell by means of compressor of min 250 PSI capacity and over pumping by pump of capacity not less than 30 HP untill the sand free water obtained and carrying out necessary yield test by V notch method and submitting the test report complete all as specified and directed. Note:- The submersible pump / compressor and other eqpts shall be arranged by the Contractor and cost of FOL for running the compressor is deemed to be included in the item rate. (i) First 24 hours of development (collectively). |
| 56 | Supplying Strata sample box made of Ist class soft wood (Deodar) with glazed shutter and pigeon holes for depth dsample at the interval of every 3 meters and supplying of strata chart duly marked on 3 mm thick laminated sheet of size 4 inch x 3 inch giving complete details of display of installation, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 57 | Supplying Strata sample box made of Ist class soft wood (Deodar) with glazed shutter and pigeon holes for depth dsample at the interval of every 3 meters and supplying of strata chart duly marked on 3 mm thick laminated sheet of size 4 inch x 3 inch giving complete details of display of installation, complete all as specified and as directed. Please Enable Macros to View BoQ information |