| 1 | Preventive maintenance of 800A to 300A, 500V PCC panels as per technical specifications. |
| 2 | Preventive maintenance of 250A to 100A, 500V PCC panels as per technical specifications. |
| 3 | Preventive maintenance of 63/50A to 32A, 500V PCC panels as per technical specifications. |
| 4 | Preventive maintenance of medium-voltage switchgear Panel as per technical specifications. |
| 5 | Inspection, maintenance, and testing of 500V AC, 800A breaker panel, including relay/release testing and coordination as per technical specifications. |
| 6 | Preventive maintenance of 630A to 400A, 500V AC distribution MCC panel with contactors at each feeder as per technical specifications. |
| 7 | Preventive maintenance of 250/200A to 100A, 500V AC MCC panels as per technical specifications. |
| 8 | Preventive maintenance of 63A to 16 A, 500V AC MCC panels as per technical specification |
| 9 | Preventive maintenance of lighting & power three phase and single phase MCCB/MCB distribution boards as per technical specifications. |
| 10 | Preventive maintenance of various types of control terminal boxes & control juction boxes as per technical specifications. |
| 11 | Maintenance and Testing record report of all plate earthing stations as per technical specifications. |
| 12 | Supply and replacement of 4-pole, 415V AC, 63A MCB (D-curve) for the existing distribution board as per technical specifications. |
| 13 | Supply and replacement of 4-pole, 415V AC, 32A MCB (D-curve) for the existing distribution board as per technical specifications. |
| 14 | Supply and replacement of 4-pole, 415V AC, 300mA, 40A RCCB for the existing distribution board as per technical specifications. |
| 15 | Supply and replacement of 4-pole, 415V AC, 300mA, 63A RCCB for the existing distribution board as per technical specifications. |
| 16 | Supply and replacement of 4-pole, 415V AC, 100mA, 63A RCCB for the existing distribution board as per technical specifications. |
| 17 | Supply and replacement of 4-pole, 415V AC, 100mA, 40A RCCB for the existing distribution board as per technical specifications. |
| 18 | Supply and replacement of 2-pole, 240V AC, 25A, 30mA RCCB for the existing distribution board as per technical specifications. |
| 19 | Supply and replacement of 2-pole, 415V AC, 25A MCB (D-curve) for the existing distribution board as per technical specifications. |
| 20 | Supply and replacement of auxiliary changeover switch (6A rating contacts) for the existing distribution board as per technical specifications. |
| 21 | Removal of existing cables of sizes 7 mm to 38 mm diameter as per technical specifications. |
| 22 | Excavation of earth in various types of soil as per technical specifications. |
| 23 | Fabrication, supply, and installation of M.S. supports as per technical specifications. |
| 24 | Fabrication and supply, installation for less then 01 kg weight of M.S Box as per technical specifications. |
| 25 | Fabrication & supply, installation for more then 01 kg weight of M.S Box as per technical specifications. |
| 26 | Design, manufacturing, supply, and installation of aluminum anodized labels as per technical specifications. |
| 27 | Supply and installation of tinned copper earthing strip as per technical specifications. |
| 28 | Supply and installation of bare copper conductor earthing wire as per technical specifications. |
| 29 | Supply and installation of panel door lock as per technical specifications. |
| 30 | Supply and installation of panel lock key as per technical specifications. |
| 31 | Supply and replacement of various types of LED indication lamps with holders for existing power/control panels as per technical specifications. |
| 32 | Only installation of 25 mm × 12.5 mm and 38 mm × 38 mm aluminum casing capping as per technical specifications. |
| 33 | Supply and installation of 1.5 sq.mm XLPE FRLS wires in existing conduits, channels, or casing capping as per technical specifications. |
| 34 | Supply and installation of 2.5 sq.mm XLPE FRLS wires in existing conduits, channels, or casing capping as per technical specifications. |
| 35 | Supply and replacement of digital meter with RS485 port, Class 1.0 accuracy, for existing power panel/distribution panel as per technical specifications. |
| 36 | Supply and installation of auto-glow radium reflective tape as per technical specifications. |
| 37 | Supply, installation, testing, and commissioning of surface 2-module metal boxes suitable for mounting modular plates and switches as per technical specifications. |
| 38 | Supply, installation, testing, and commissioning of surface 6-module metal boxes with suitable modular plates, 16A switches, and 6/16A universal 5-pin, 2-module sockets as per technical specifications. |
| 39 | Supply, installation, testing and commissioning of surface 8 Module metal boxes with suitable mounting modular plate 16A switchs and 6/16 A socket 5 pin 3 module as per technical specifications. |
| 40 | Supply, installation, testing, and commissioning of surface 12-module metal boxes suitable for mounting modular plates with 16A switches and 6A universal 5-pin, 2-module sockets as per technical specifications. |
| 41 | Supply, installation, testing and commissioning of various types of analog time switch modules, 16 A, 230 V AC, as per technical specifications. |
| 42 | Supply, installation, testing, and commissioning of weatherproof cabinets with one row of 12 modules and accessories as per technical specifications. |
| 43 | Supply installation testing and commissioning of weather proof cabinate 4 module as per technical specification. |
| 44 | Replacement, supply, installation, testing, and commissioning of the PA system as per technical specifications. |
| 45 | Supply and replacement of console station as per technical specifications. |
| 46 | Supply and replacement of 6W speaker as per technical specifications. |
| 47 | Supply and replacement of 30W speaker as per technical |
| 48 | Supply and replacement of LED highway lighting fixtures as per technical specifications. |
| 49 | Providing of 4C x 2.5 sq.mm copper conductor XLPE insulated armoured cables as per technical specifications. |
| 50 | Providing of 4C x 6 sq.mm copper conductor XLPE insulated armoured cables as per technical specifications. |
| 51 | Providing of 4C x 16 sq.mm copper conductor XLPE insulated armoured cables as per technical specifications. |
| 52 | Providing of 3.5C x 25 sq.mm copper conductor XLPE insulated armoured cables as per technical specifications. |
| 53 | Providing of 2P x 1.0 sq.mm copper conductor shielded armoured cable as per technical specifications. |
| 54 | Providing of 4P x 1.0 sq.mm copper conductor shielded armoured cable as per technical specifications. |
| 55 | Providing of 6P x 1.0 sq.mm copper conductor shielded armoured cable as per technical specifications. |
| 56 | Providing of 50 pair jelly field armoured telephone cable as per technical specifications. |
| 57 | Providing of 1C X 300 sqmm multistranded copper conductor, PVC flexible cable as per technical specification. |
| 58 | In surface Installation of 7mm to 20mm diameter PVC/XLPE unarmoured/armoured cables as per technical specifications. |
| 59 | In surface Installation of 21mm to 38mm diameter PVC/XLPE unarmoured/armoured cables as per technical specifications. |
| 60 | Underground Installation of 21mm to 38mm diameter PVC/XLPE armoured cables as per technical specifications. |
| 61 | End termination of 7–23 mm diameter PVC/XLPE unarmoured/armoured cables as per technical specifications. |
| 62 | End termination of 24–38 mm diameter PVC/XLPE unarmoured/armoured cables as per technical specifications. |
| 63 | Supply and replacement of exhaust fan as per technical specifications. |
| 64 | Supply, installation, testing, and commissioning of smart screen with digital board as per technical specifications. |
| 65 | Supply, installation, testing, and commissioning of video conferencing system as per technical specifications. |
| 66 | Supply, installation, testing and commissioning of 600 x 600 x 6 mm thick tinned copper plate earth station as per technical specification. |
| 67 | Supply, installation testing and comissioning of 125A, 415V AC distribution panel as per technical specification. |
| 68 | Supply, installation, testing and demostretion of data recording system for SCADA system as per technical specification |
| 69 | Supply& installation of spare materials for exiting AMF panel as per technical specifications. |
| 70 | Providing of data entry operater service inside BARC permises as per technical specification. |
| 71 | Providing of draftsman service inside BARC permises as per technical specification. |
| 72 | Carring out miscellaneous job (not coved in items) as per technical specification. Please Enable Macros to View BoQ information |