| Sl. No. | Item Description |
| 1 | Earthwork in excavation in ordinary soil with lift 1.5m & lead upto 30m etc including all work complete |
| 2 | Earth work in filling upto 8 km distance frome site including loading unloading cartage etc complete (anallises Rate) |
| 3 | P.C.C 1:4:8 with in cement and fine sand and 40 mm gauge brick ballast in all work complete |
| 4 | Supply and filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete |
| 5 | Providing and injecting chemical emulsion for preconstructional antilermile tratment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the external perimeter in all complete work treatment of soil along external perimeter of building 7.5 litre/sqm treatment of soil under apron along external perimeter 5 litre/sqm |
| 6 | C.C. 1:1.5:3 cement course sand and 20 mm gauge stone grit with micron polythene (without dovel bar) all work complete |
| 7 | R.C.C. 1:1.5:3 cement course sand and 20 mm gauge stone grit all work complete (S.I. No. 284(a)) |
| 8 | C.C. 1:1.5:3 cement course sand and 20 mm gauge stone grit with micron polythene (without dovel bar) all work complete |
| 9 | Mild steel work in all work complete (S.I. No. 504) |
| 10 | M-150 class brick work in 1:6 cement and fine sand mortar in all complete |
| 11 | M-150 class brick work in 1:6 cement and fine sand mortar in all complete |
| 12 | 15mm thick plaster 1:4 cement and Fine sand mortar in all complete |
| 13 | Finishing wall with water proof paint weather coat Two coat with all material labour T&P etc all complete |
| 14 | Appying priming coat 13.50.2 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood in all complete work |
| 15 | C.C 1:2:4 cement core. sand and 20 mm stone grit in all complete (S.I. No. 279 (a)) |
| 16 | 22mm thick plaster 1:4 cement and Fine sand mortar in all complete |
| 17 | Steel work in built up tubular round square or rectangular hollow tubes etc trusses in all complete work |
| 18 | Extra for providing and fixing wind ties of 40x6mm flat iron section |
| 19 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with with polymer coated J or L hook in all complete work |
| 20 | Providing and fixing 15cm wide 45cm overall semicircular plain G.S sheet gutter with iron brackets 40x3mm size bolt, nuts and washers in all complete work |
| 21 | Centering and shuttering including strutting, propping etc and removal of form work for lintels, beams, plinth beams, griders, bressumers and cantilevers |
| 22 | Foundation, footings, bases of coloumn etc for mass concrete in all complete work |
| 23 | Columns, pillars, piers, abutments, posts and structs in all complete work |
| 24 | Writing for light point/fan point/ exhuast fan point/call bell poimt with 1.5 sqmm FR PVC insulated copper conductor single core cable in surface/recessed PVC condu,t, with modular switch modular plate in all complete work |
| 25 | Wiring forcircuit/submain wiring along with earth wire with the following sizes of PVC insulated. Copper conductor single core cable in surface/recessed PVC conduit as required 2x1.5 sq.mm+1x1.5 sq.mm earth wire |
| 26 | Wiring forcircuit/submain wiring along with earth wire with the following sizes of PVC insulated. Copper conductor single core cable in surface/recessed PVC conduit as required 2x2.5 sq.mm+1x2.5 sq.mm earth wire |
| 27 | Wiring forcircuit/submain wiring along with earth wire with the following sizes of PVC insulated. Copper conductor single core cable in surface/recessed PVC conduit as required 2x4 sq.mm+1x4 sq.mm earth wire |
| 28 | Wiring forcircuit/submain wiring along with earth wire with the following sizes of PVC insulated. Copper conductor single core cable in surface/recessed PVC conduit as required 2x6 sq.mm+1x6 sq.mm earth wire |
| 29 | Wiring forcircuit/submain wiring along with earth wire with the following sizes of PVC insulated. Copper conductor single core cable in surface/recessed PVC conduit as required 4x10 sq.mm+2x6 sq.mm earth wire |
| 30 | supply and fixing of following sizes of PVC conduit along with accessories in surface/recess including incuding cutting the wall and making good the same in case of recessed conduit as required 20mm |
| 31 | supply and fixing of following sizes of PVC conduit along with accessories in surface/recess including incuding cutting the wall and making good the same in case of recessed conduit as required 25mm |
| 32 | supply and drawing following sizes pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telehone cable in the existing surface/ recessed steel/ PVC conduit as reuired 2 pair |
| 33 | Supply and fixing following modular switch/socket on the existing modular plate & switch box in all complete work telephone socket outlet |
| 34 | Supplying and fixing metal box of following size nomonal size on surface or recess with suitable size of phenolic laminated sheet cover in front in all complete work 75mmx75mmx60mm deep |
| 35 | supplying and fixing following size/modular GI box strong with modular bas & cover plate for modular switches in recess 1 or 2 module (75mmx75mm) |
| 36 | Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 37 | Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing pin 5/6 amps, modular socket outlet and 5/6 amps modular switch connection painting etc as reuired |
| 38 | Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps, modular socket outlet and 15/16 amps modular switch connection painting etc as reuired |
| 39 | Supplying and fixing following way, three pole and natural, sheet steel, TP MCB distribution board. 415 volts on surface/recess, complete with tinned copper busbar, neutral burbar, earth bar, din bar, ditachable gland plate in all complete work 4way(4+12)double door, horizontal type) |
| 40 | Supplying and fixing 5 amps to 32 amps rating 240 volts C series miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB in all complete work single pole |
| 41 | Supplying & fixing single pole, blanking plate in the existing MCB DB complete as reuired |
| 42 | supplying and fixing following rating four pole 415 volts, isolator in the existing MCB DC complete with connections, testing and commissioning etc as required 40 amps |
| 43 | Installation, testing and commissioning of celling fan including wiring the down rod of standard length (upto 30cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable.in all complete work |
| 44 | Earthing with GI earth plate 600mx600mmx6mm thick including accessories and providing masonary enclsure with cover plate having locking arrangement in all complete work |
| 45 | Supplying and laying 25mmx5mm GI strip at 0.50m below ground as strip earth electrode including connection and terminating with nut, bolt, spring, washer in all complete work |
| 46 | Supplying and laying 32mmx6mm G.I strip from earth electrode directly in ground as required |
| 47 | Providing and fixing of circular/hexazonal cast ironor MS sheet box for ceiling fan clamp of internal dia 140mm 70mm height top lid of 1.5mm thick MS sheet with in all complete work |
| 48 | Providing and fixing M.V danger notice plate ogf 200mmx150mm made of mild steel, atleast 2mm thick and vertious enamelled in all complete work |
| 49 | wiring forcircuit/submain wiring along with earth wire with the following sizes of PVC insulated copper conductor single core cable in surface/recessed PVC conduct as required 2x2.5sq.mm+1x2.5sq/mm earth wire |
| 50 | Supply and fixing of following sizes of PVC conduct alng with accessories in surface/recess including cutting the wall and making in all complete work |
| 51 | Supplying and wiring of sub main with FR PVC insulated 1100 volts grade single core copper conductor cable in heavy gauge PVC condit partly in all complete work 4x25 sqmm with 2x16 sqmm earth wire in 50mm dia |
| 52 | S/F of single light wall bracket (Cat-AAA) on matching M.D.F.E.G board base etc in all complete work |
| 53 | Supply and fixing of LED tube light with battensuitable for up to 1x22 watt LED tube light fitting including tube on surface in all complete work |
| 54 | Supply and ceiling fan with fan mortor of AC permanent insulator, capacitor rating conforming BEE 5 star rating and in all complete work |
| 55 | Supply and fixing of crimping, solder, less copper ton electroplated lugs of dowel/is mail make suitable for 1.5sqmm to 6sqmm cable in all complete work |
| 56 | S/F of sheet steel enclosure for DP/TP/FP MCB with neutral link and earth terminal |
| 57 | Supply and fixing of electronic Fan regulator modular 120-280v on the existing switch board in all complete work |
| 58 | Supply of AC 230/250 volts, 50 Hz 55w 1400rpm exhaust fans in all complete work |
| 59 | Supply and fixing of LED street light fitting with mandatory driver set in all complete work |
| 60 | Supply and fixing high mast light |
| 61 | Earthwork in excavation in ordinary soil with lift 1.5m & lead upto 30m etc including all work complete |
| 62 | P.C.C 1:4:8 with in cement and fine sand and 40 mm gauge brick ballast in all work complete |
| 63 | M-150 class brick work in 1:6 cement and fine sand mortar in all complete |
| 64 | 12mm thick plaster 1:4 cement and Fine sand mortar in all complete |
| 65 | C.C 1:2:4 cement core. sand and cement concrete flooring in all complete |
| 66 | Earth work in excavation by mechanicalmeans (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer- in charge. |
| 67 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal sizederived from natural sources) |
| 68 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone- III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). slab |
| 69 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) FOUNDATION |
| 70 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement :1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) COLUMN |
| 71 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation7.5 in foundation and plinth in:Cementmortar 1:6 (1 cement : 6 coarse sand) |
| 72 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarsesand) |
| 73 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete Thermo-Mechanically Treatedbars of grade Fe-500D or more |
| 74 | 12 mm cement plaster of mix 1:6 (1cement: 6 coarse sand) |
| 75 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10sqm) |
| 76 | structiral steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 77 | Finishing with epoxy paint two or more coats at all locations prepared in all complete work |
| 78 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge.2.6.1 All kinds of soil |
| 79 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 80 | Brick work with common burnt clayF.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 81 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate20 mm nominal size derived from |
| 82 | Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. 16.46.1 Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. |
| 83 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. 2.6.1 All kinds ofsoil |
| 84 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 85 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 86 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating anddressing complete. |
| 87 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints,surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313 ( Part II 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or chordancewill be used. The rate of application of chemical emulsion shallbe as follows : (1 Treatment for masonary & foundation 5 liters pe r/ 100 Sqm.(2) Back fill in immediate contact with foundation 7.5 liters / 100 Sqm. (3) Treatment of top surface of plinth filling 5 liters / 100 Sqm. (4)Treatment junction of wall and the floor 7.5 liters / 100 Sqm. (5)Treatment of soil along external perimeter of building 7.5liters / 10 |
| 88 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).bands |
| 89 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).beams |
| 90 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). slab |
| 91 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 92 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in positionand binding all complete |
| 93 | Brick work with common burnt clay (non modular) bricks of class designation 150 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarsesand) |
| 94 | Brick work with common burnt clay (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarsesand) |
| 95 | Brick work with common burnt clay (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarsesand) |
| 96 | Providing and fixing ISI marked flush door shutters conforming to IS 2202 Part I decorative type, core of block board in all complete work |
| 97 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer all complete. |
| 98 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer all complete. |
| 99 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer all complete. |
| 100 | Fixing of steel or wooden chaukhats in position. (a) Door chaukhats |
| 101 | Fixing of steel or wooden chaukhats in position. (b) Wndow chaukhats |
| 102 | 15 mm thick plinth plaster [1 cement : 4 coarse sand] |
| 103 | 12 mm cement plaster of mix 1:6 (1 cement: 6coarse sand) |
| 104 | 15 mm cement plaster of mix 1:6 (1 cement: 6coarse sand) |
| 105 | Making grooves 10 to 12mm wide x 8 mm deep in plaster of the walls or in ceiling vertically orhorizontally as required. |
| 106 | Making drip course deep in plaster of the walls or inceiling vertically or horizontally as required. |
| 107 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominalsize stone aggregate |
| 108 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floatingcoat of neat cement 18 mm thick |
| 109 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 110 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 111 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 112 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat withcement primer |
| 113 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes |
| 114 | Providing oxidised Sliding Bolts 16 mm dia with nuts and 250 mm long. |
| 115 | Providing oxidised tower bolt with 10mm dia 250mm long ground floor |
| 116 | Providing oxidised door handles wirh screwes 125mm long ground floor |
| 117 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conformingto IS. 2645 and approved by Engineer-in-charge over the RCCslab including adjoining walls upto 300 mm height includingcleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats25 mm to 115 mm size with 50% of cement mortar 1:5 (1cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge over 20 mm thick layer of cement mortar of mix 1:5(1 cement :5 coarse sand ) admixed with water proofingcompound conforming to IS : 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoiningwalls upto 300 mm height including rounding ofjunctions of |
| 118 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors 40 mm wide and 4 mm thick |
| 119 | Suspended floors, roofs, landings, balconies and accessplatform |
| 120 | Lintels, beams, plinth beams, girders, bressumersand cantilevers |
| 121 | Foundations, footings, bases of columns, etc. formass concrete |
| 122 | Wiring for light point/fan point/exhaust fan point/call bell pointwith 1.5 sqmm FR PVC insulatedcopper conductor single core cable in surface / recessed PVC conduit,with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc.as required. |
| 123 | Wiring forcircuit / submain wiring alongwith earth wire with the following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required. 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earthwire |
| 124 | Wiring forcircuit / submain wiring alongwith earth wire with the following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required. 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. Earthwire |
| 125 | Wiring forcircuit / submain wiring alongwith earth wire with the following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required. 2 x 4 sq.mm. + 1 x 4 sq.mm. Earthwire |
| 126 | supply and fixing of following sizes of PVC conduit along with accessories in surface/recess including incuding cutting the wall and making good the same in case of recessed conduit as required 20mm |
| 127 | supply and drawing following sizes pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telehone cable in the existing surface/ recessed steel/ PVC conduit as reuired 2 pair |
| 128 | Supply and fixing following modular switch/socket on the existing modular plate & switch box in all complete work telephone socket outlet |
| 129 | Supplying and fixing metal box of following size nomonal size on surface or recess with suitable size of phenolic laminated sheet cover in front in all complete work 75mmx75mmx60mm deep |
| 130 | supplying and fixing following size/modular GI box strong with modular bas & cover plate for modular switches in recess 1 or 2 module (75mmx75mm) |
| 131 | Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 132 | Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing pin 5/6 amps, modular socket outlet and 5/6 amps modular switch connection painting etc as reuired |
| 133 | Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps, modular socket outlet and 15/16 amps modular switch connection painting etc as reuired |
| 134 | Supplying and fixing following way, three pole and natural, sheet steel, TP MCB distribution board. 415 volts on surface/recess, complete with tinned copper busbar, neutral burbar, earth bar, din bar, ditachable gland plate in all complete work 4way(4+12)double door, horizontal type) |
| 135 | Supplying and fixing 5 amps to 32 amps rating 240 volts C series miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB in all complete work single pole |
| 136 | Supplying & fixing single pole, blanking plate in the existing MCB DB complete as reuired |
| 137 | supplying and fixing following rating four pole 415 volts, isolator in the existing MCB DC complete with connections, testing and commissioning etc as required 40 amps |
| 138 | Installation, testing and commissioning of celling fan including wiring the down rod of standard length (upto 30cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable.in all complete work |
| 139 | Installation of exhaust fan upyo 450mm sweep in the existing operning in all complete work |
| 140 | Extra for fixing the louvers/shutters complete with frame for exhaust fans in all complete work |
| 141 | Earthing with GI earth plate 600mx600mmx6mm thick including accessories and providing masonary enclsure with cover plate having locking arrangement in all complete work |
| 142 | Supplying and laying 25mmx5mm GI strip at 0.50m below ground as strip earth electrode including connection and terminating with nut, bolt, spring, washer in all complete work |
| 143 | Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing as required |
| 144 | Providing and fixing of circular/hexazonal cast ironor MS sheet box for ceiling fan clamp of internal dia 140mm 70mm height top lid of 1.5mm thick MS sheet with in all complete work |
| 145 | supply and fixing of 32mm dia 2 meter long GI pipe medium class bracket for mounting of fluorescent/HPMV/HPSV street lightfilling in a ll complete work |
| 146 | wiring forcircuit/submain wiring along with earth wire with the following sizes of PVC insulated copper conductor single core cable in surface/recessed PVC conduct as required 2x2.5sq.mm+1x2.5sq/mm earth wire |
| 147 | Supply and fixing of following sizes of PVC conduct alng with accessories in surface/recess including cutting the wall and making in all complete work 50mm |
| 148 | Supplying and wiring of sub main with FR PVC insulated 1100 volts grade single core copper conductor cable in heavy gauge PVC condit partly in all complete work 4x25 sqmm with 2x16 sqmm earth wire in 50mm dia |
| 149 | S/F of single light wall bracket (Cat-AAA) on matching M.D.F.E.G board base etc in all complete work |
| 150 | Supply and ceiling fan with fan mortor of AC permanent insulator, capacitor rating conforming BEE 5 star rating and in all complete work |
| 151 | Supply and fixing of electronic Fan regulator modular 120-280v on the existing switch board in all complete work |
| 152 | Earth work in excavation by mechanicalmeans (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer- in charge. |
| 153 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal sizederived from natural sources) |
| 154 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) FOUNDATION |
| 155 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement :1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) COLUMN |
| 156 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete Thermo-Mechanically Treatedbars of grade Fe-500D or more |
| 157 | 12 mm cement plaster of mix 1:6 (1cement: 6 coarse sand) |
| 158 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10sqm) |
| 159 | structiral steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 160 | Finishing with epoxy paint two or more coats at all locations prepared in all complete work |
| 161 | Foundations, footing, bases of coloumns etc I all complete work |
| 162 | Coloumns, pillars, perls, abutments, posts and struts |
| 163 | Automatic gate security system |
| 164 | Earth work in excavation by mechanical means(Hydraulic excavator)/ manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as10 sqm on plan) including getting out and disposal ofexcavated earth lead upto 50 m and lift upto 1.5 m,as directed by Engineer-in charge. 2.6.1 All kinds of |
| 165 | Excavating, supplying and filling of local earth(including royalty) by mechanical transport upto alead of 5km also including ramming and watering ofthe earth in layers not exceeding 20 cm in trenches,plinth, sides of foundation etc. complete. |
| 166 | Providing and laying in position cement concrete ofspecified grade excluding the cost of centering andshuttering - All work up to plinth level :1:4:8 (1Cement : 4 coarse sand (zone-III) derived fromnaturalsources : 8 graded stone aggregate 20 mm nominal |
| 167 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete |
| 168 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating achemical barrier under and alround the column pitswall trenches basement excavation top surface ifplinth filling junction of wall and floor, along the theexternal perimeter of binding expansion joints,surrounding of pipes and conduits etc, complete.(plinth area of the building at ground floor only shallbe measured as per I.S.6313 (PartII 1981) Alderineemulsifiable concentrate or any other approvedmaterial such as Heptrachlor or Chlordane will beused. The rate of application of chemical emulsionshall be as follows : (1) Treatment for masonary &foundation 5 liters per sqm. (2) Back fill in immediatecontact with foundation 7.5 liters/sqm (3) Treatmentof top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters/sqm (5) Treatment of soil along external perimeter ofbuilding 7.5 liters/sqm (6) Treatment of soil underapron along external perimter 5 liters/sqm. two days |
| 169 | Providing and laying in position ready mixed or sitebatched design mix cement concrete for reinforcedcement concrete work; using coarse aggregate andfine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slagcement, admixtures in recommended proportions asper 1S: 9103 to accelerate / retard setting ofconcrete, to improve durability and workabilitywithout impairing strength; including pumping ofconcrete to site of laying, curing, carriage for allleads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of theengineer-in-charge, for the following grades o |
| 170 | Providing and laying in position ready mixed or sitebatched design mix cement concrete for reinforcedcement concrete work; using coarse aggregate andfine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slagcement, admixtures in recommended proportions asper 1S: 9103 to accelerate / retard setting ofconcrete, to improve durability and workabilitywithout impairing strength; including pumping ofconcrete to site of laying, curing, carriage for allleads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of theengineer-in-charge, for the following grades of |
| 171 | Providing and laying in position ready mixed or sitebatched design mix cement concrete for reinforcedcement concrete work; using coarse aggregate andfine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slagcement, admixtures in recommended proportions asper 1S: 9103 to accelerate / retard setting ofconcrete, to improve durability and workabilitywithout impairing strength; including pumping ofconcrete to site of laying, curing, carriage for allleads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of theengineer-in-charge, for the following grades o |
| 172 | Providing and laying in position ready mixed or sitebatched design mix cement concrete for reinforcedcement concrete work; using coarse aggregate andfine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slagcement, admixtures in recommended proportions asper 1S: 9103 to accelerate / retard setting ofconcrete, to improve durability and workabilitywithout impairing strength; including pumping ofconcrete to site of laying, curing, carriage for allleads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of theengineer-in-charge, for the following grades o |
| 173 | Providing and laying in position ready mixed or sitebatched design mix cement concrete for reinforcedcement concrete work; using coarse aggregate andfine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slagcement, admixtures in recommended proportions asper 1S: 9103 to accelerate / retard setting ofconcrete, to improve durability and workabilitywithout impairing strength; including pumping ofconcrete to site of laying, curing, carriage for allleads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of theengineer-in-charge, for the following grades of |
| 174 | Providing and laying in position ready mixed or sitebatched design mix cement concrete for reinforcedcement concrete work; using coarse aggregate andfine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slagcement, admixtures in recommended proportions asper 1S: 9103 to accelerate / retard setting ofconcrete, to improve durability and workabilitywithout impairing strength; including pumping ofconcrete to site of laying, curing, carriage for allleads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of theengineer-in-charge, for the following grades ofconcrete.: M-25 |
| 175 | Steel reinforcement for R.C.C. work includingstraightening, cutting, bending, placing in positionand binding all complete |
| 176 | Brick work with common burnt clay (non modular)bricks of class designation 150 in foundation andplinth in:Cement mortar 1:6 (1 cement : 6 coarse |
| 177 | Providing and laying damp-proof course 40mm thickwith cementconcrete 1:2:4 (1 cement : 2 coarse sand (zone-III)derived from naturalsources : 4 graded stone aggregate 12.5mmnominal size derived f |
| 178 | Providing & applying a coat of residual petroleumbitumen of grade ofVG-10 of approved quality using 1.7kg per squaremetre on damp proofcourse after cleaning the surface with brushes andfinally with apiece of cloth lightly soaked in kerosene oil. |
| 179 | Brick work with common burnt clay (non modular)bricks of class designation 150 in superstructureabove plinth level up to floor V level in all shapes andsizes in Cement mortar 1:6 (1 cement : 6 coarse |
| 180 | Brick work with common burnt clay (non modular)bricks of class designation 150 in superstructureabove plinth level up to floor V level in all shapes andsizes in Cement mortar 1:4 (1 cement : 4 coarse |
| 181 | Providing and fixing 35 mm thick factory madelaminated veneer lumber door shutter conforming toIS : 14616 and TADS 15:2001 (Part B), fixing withbutt hinges of required size with necessary screws,all complete as per directions of Engineer- in-chargeand panelling with panels of : 12 mm thick one sidePre-laminated particle board (decorative laminationon one side and other sides balancing lamination)grade -1, medium density flat pressed, three layerparticle board FPT - I or graded wood particle boardFPT-1 conforming to IS : 3087 bonded with BWPtype synthetic resin adhesive as per IS : 848 and prelaminated conforming to IS : 12823, Grade -1, Type |
| 182 | Providing and fixing ISI marked flush door shuttersconforming to IS : 2202 (Part I) decorative type, coreof block board construction with frame of 1st classhard wood and well matched teak 3 ply veneeringwith vertical grains or cross bands and face veneerson both faces of shutters.35 mm thick including ISImarked Stainless Steel butt hinges with necessary |
| 183 | Providing wood work in frames of doors, windows,clerestory windows and other frames, wroughtframed and fixed in position with hold fast lugs orwith dash fasteners of required dia & length ( holdfast lugs or dash fastener shall be paid fo |
| 184 | Providing and fixing factory made uPVC glazed/wiremesh windows/ doors comprising of lead free uPVCmulti-chambered frame, sash and mullion/coupler(where ever required) extruded profiles havingminimum wall thickness of 1.70 mm for Series R1and R2 profiles and 2.10 mm for Series R3 and R4profiles conforming to EN: 12608 in any shape,colour and design duly reinforced with galvanizedmild steel section made of required shape & size asper CPWD Specification, uPVC extruded glazingbeads, interlocks and Inline sash adaptor (whereever required) of appropriate dimension, EPDMgasket, hardware, SS 304 grade fasteners ofminimum 8 mm dia with countersunk head,comprising of matching polyamide PA6 grade sleevefor fixing frame to finished wall as per IS 1367 : Part1 to 14, plastic packers, plastic caps and necessarystainless steel screws etc. Profile of frame, sash &mullion (if required) shall be mitred cut and fusionwelded/mechanically jointed duly sealed at allcomers, including drilling of holes for fixing hardwareand drainage of water etc. After fixing frame the gapbetween frame and adjacent finished wall shall befilled with weather proof silicon sealant over backerrod of approved size and quality, all complete as perapproved drawing conforming to CPWD specification& direction of Engineer-in-Charge. Section of steelreinforcement and cross sections of uPVC profiles t |
| 185 | Providing and fixing M.S. grills of required pattern inframes of windows etc. with M.S. flats, square orround bars etc. including priming coat with approvedsteel primer all complete. |
| 186 | G.F,F.F.& S.F. |
| 187 | Fixing of steel or wooden chaukhats in position. |
| 188 | (a) Door chaukhats |
| 189 | (b) Window chaukhats |
| 190 | (c) Ventilator chaukhats |
| 191 | 15 mm cement plaster on rough side of single or halfbrick wall ofmix 1:4 (1 cement: 4 coarse sand) |
| 192 | 12 mm cement plaster of mix 1:6 (1 cement: 6coarse sand) |
| 193 | 15 mm cement plaster of mix 1:6 (1 cement: 6coarse sand) |
| 194 | Making grooves in sun shade or facia as perdirection of Engineer incharge including supply of allmaterials,labour T & P etc for proper completion ofthe work. Excluding GST |
| 195 | Making drip course in sun shade or facia as perdirection of Engineer incharge including supply of allmaterials,labour T & P etc for proper completion ofthe work. Excluding GST |
| 196 | Providing and laying vitrified floor tiles in differentsizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in allcolours and shades, laid on 20mm thick cementmortar 1:4 (1 cement : 4 coarse sand), jointing withgrey cement slurry @ 3.3 kg/ sqm including groutingthe joints with white cement and matching pigmentsetc., complete Size of Tile 600x600 mm |
| 197 | Providing and laying Vitrified tiles in different sizes(thickness to be specified by manufacturer), withwater absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade,in skirting, riser of steps, over 12 mm thick bed ofcement mortar 1:3 (1 cement: 3 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joint with white cement &matching pigments etc. complete |
| 198 | Providing and laying vitrified floor tiles in differentsizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in allcolours and shades, laid on 20mm thick cementmortar 1:4 (1 cement : 4 coarse sand), jointing withgrey cement slurry @ 3.3 kg/ sqm including groutingthe joints with white cement and matching pigmentsetc., complete (Anti Skid Vitrified flooring) (600x600 |
| 199 | Providing and laying Ceramic glazed floor tiles of size300x300 mm (thickness to be specified by themanufacturer) of 1st quality conforming to IS : 15622of approved make in colours such as White, Ivory,Grey, Fume Red Brown, laid on 20 mm thick cementmortar 1:4 (1 Cement : 4 Coarse sand), Jointing withgrey cement slurry @ 3.3 kg/sqm including pointingthe joints with white cement and matching pigment |
| 200 | Providing and fixing Ist quality ceramic glazed walltiles conforming to IS: 15622 (thickness to bespecified by the manufacturer), of approved make,in all colours, shades except burgundy, bottle green,black of any size as approved by Engineer-inCharge, in skirting, risers of steps and dados, over12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cementmixed with pigment of matching shade |
| 201 | Providing and laying Polished Granite stone flooringin required design and patterns, in linear as well ascurvilinear portions of the building all complete as perthe architectural drawings with 18 mm thick stoneslab over 20 mm (average) thick base of cementmortar 1:4 (1 cement : 4 coarse sand) laid andjointed with cement slurry and pointing with whitecement slurry admixed with pigment of matchingshade including rubbing, curing and polishing etc. allcomplete as specified and as directed by theEngineer-in-Charge.Polished Granite stone slab |
| 202 | Cement concrete flooring 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate) finished with afloating coat of neat cement, including cement slurry,but excluding the cost of nosing of steps etc.complete.40 mm thick with 20 mm nominal siz |
| 203 | Applying priming coat: With ready mixed red oxidezinc chromate primer of approved brand andmanufacture on steel galvanised iron/ steel worksFinishing with Epoxy paint (two or more coats) at alllocations prepared and applied as per manufacturer’sspecifications including appropriate priming coat,preparation of surface, etc. complete. 13.52.1 On |
| 204 | Finishing with Deluxe Multi surface paint system forinteriors and exteriors using Primer as permanufacturers specifications Painting wood workwith Deluxe Multi Surface Paint of required shade.Two or more coat applied @ 0.90 ltr/10 sqm over anunder coat of primer applied @0.75 ltr/10 sqm ofapproved brand and manufacture |
| 205 | Polishing in high gloss/matt finish melamine clearpolish on wood work in required color/wooden shadetexture with following process in the sequence asdetailed below:1. The surface to be polished is rubbed with sandpaper 80/ 120 no. and then with sand paper of160/180 nos.2. Applying two coats of sealer with spray gun andallowingsufficient drying time for 1st coat and 2nd coat isallowedto dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emerycloth offiner grading with ample water to remove excesssealerlayer and make the surface further smooth after thiswetrubbing, then surface is applied with special grademelamine fillers to fill all the small and bigholes/groovesetc. Filler coat to be allowed to dry for 4 to 6 hrs onwhichagain a light wet rubbing is done this surface isfurtherallowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied withspray |
| 206 | Finishing walls with Premium Acrylic Smooth exteriorpaint with Silicone additives of required shade : Newwork (Two or more coats applied @ 1.43 ltr/ 10 sqmover and including priming coat of exterior primerapplied @ 2.20 kg/ 10 sqm). |
| 207 | Providing and applying plaster of paris putty of 2 mmthickness over plastered surface to prepare thesurface even and smooth complete. |
| 208 | Wall painting with acrylic emulsion paint, having VOC(Volatile Organic Compound ) content less than 50grams/ litre, of approved brand and manufacture,including applying additional coats whereverrequired, to achieve even shade and colour. Two |
| 209 | Providing & fixing glass panes with putty and glazingclips in steel doors, windows, clerestory windows, allcomplete with :4.0 mm thick glass panes |
| 210 | Providing & fixing Stainless steel Sliding bolts withnuts & bolts (Bolt 16mm dia 250mm long) |
| 211 | Providing & fixing Stainless steel Tower bolts withnuts & bolts (Bolt 10mm dia 200mm long) |
| 212 | Providing & fixing Stainless steel handles withscrews etc. complete (a) 150 mm |
| 213 | Providing and laying integral cement based waterproofing treatment including preparation of surfaceas required for treatment of roofs, balconies, terracesetc consisting of following operations: a) Applying aslurry coat of neat cement using 2.75 kg/sqm. ofcement admixed with water proofing compoundconforming to IS. 2645 and approved by Engineer-incharge over the RCC slab including adjoining wallsupto 300mm height including cleaning the surfacebefore treatment. b) Laying brick bats with mortarusing broken bricks/brick bats 25 mm to 115mm sizewith 50% of cement mortar 1:5 (1 cement : 5 coarsesand) admixed with water proofing compoundconforming to IS : 2645 and approved by Engineer-incharge over 20 mm thick layer of cement mortar ofmix 1:5 (1 cement :5 coarse sand ) admixed withwater proofing compound conforming to IS : 2645and approved by Engineer-in-charge to requiredslope and treating similarly the adjoining walls upto300 mm height including rounding of junctions ofwalls and slabs c) After two days of proper curingapplying a second coat of cement slurry using2.75kg/ sqm of cement admixed with water proofingcompound conforming to IS : 2645 and approved byEngineer-in-charge. d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1cement :4 coarse sand) admixed with water proofingcompound conforming to IS : 2645 and approved by |
| 214 | Construction of drain of size of size 150 x 150 mmalong with apron including excavation,base concrete1:4:8 in thickness of 7.5cm of and brick work infoundation 1:4( 1 cement : 4 coarse sand) andbrickwork in half brick thick in foundation 25mm thickcement concrete (1:2:4 mix) flooring base and 20mmthick plaster (1:2) finished with neat cement. |
| 215 | Providing and fixing stainless steel ( Grade 304)railing made of Hollow tubes, channels, plates etc.,including welding, grinding, buffing, polishing andmaking curvature (wherever required) and fitting thesame with necessary stainless steel nuts and boltscomplete, i/c fixing the railing with necessaryaccessories & stainless steel dash fasteners ,stainless steel bolts etc., of required size, on the topof the floor or the side of waist slab with suitablearrangement as per approval of Engineer-incharge,(for payment purpose only weight of stainless steelmembers shall be considered excluding fixing |
| 216 | Providing and fixing fly proof galvanized M.S. wiregauge to windows and lerestory windows using wiregauge with average width of aperture 1.4 mm in bothdirections with wire of dia 0.63 mm all complete.With2nd class teak wood beading 62X19 mm |
| 217 | Providing and fixing glass strips in joints of terrazo/cement concrete floors 40 mm wide and 4 mm thick |
| 218 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
| 219 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 220 | Suspended floors, roofs, landings, balconies andaccess |
| 221 | Lintels, beams, plinth beams, girders, bressumersand cantilevers |
| 222 | Foundations, footings, bases of columns, etc. formass concrete |
| 223 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 224 | Wiring for light point/fan point/exhaust fanpoint/call bell pointwith 1.5 sqmm FR PVCinsulatedcopper conductor single core cable insurface / recessed PVC conduit,with modularswitch, modular plate, suitable G.I. box andearthing the point with 1.5 sqmm FR PVCinsulated copper conductor single core cable |
| 225 | Wiring for twin control light point with 1.5sqmm FR PVC insulated copper conductorsingle core cable in surface/ recessed PVCconduit, 2 way modular switch, modular plate,suitable G.I. box and earthing the point with 1.5sqmm FR PVC insulated copper conductorsingle core cable etc. as required. |
| 226 | Wiring forcircuit / submain wiring alongwithearth wire with the following sizes of PVCinsulated,copper conductor single core cablein surface/ recessed PVC conduit as required.2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. Earth wire |
| 227 | 2 x 4 sq.mm. + 1 x 4 sq.mm. Earth wire |
| 228 | 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 229 | 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire |
| 230 | Supply and fixing of following sizes of PVCconduit along with accessories insurface/recess including cutting the wall andmaking good the same in case of recessed |
| 231 | Supplying and drawing following pair 0.5 mmdia FRLS PVC insulated annealed copperconductor, unarmored telephone cable in theexisting surface/ recessed steel/ PVC conduitas required. |
| 232 | Supply and drawing of co-axial TV cable RG-6grade, 0.7 mm. Solid copper conductor PEinsulated, shielded with fine tinned copper braidand protected with PVC sheath in the existingsurface / recessed conduit as required |
| 233 | Supplying and fixing following modular switch/socket on the existing modular plate & switchbox including connections but excludingmodular plate etc. as requiredTelephone socket outlet |
| 234 | TV Antenna socket outlet |
| 235 | Supplying and fixing metal box of following size(nominal size) on surface or recess with suitablesize of phenolic laminated sheet cover in fromtincluding paintingetc. as required.75 mm x 75 mm x 60 mm deep |
| 236 | Supplying and fixing following size / modules, GIbox alongwith modular base & cover platefor modular switches in recess etc. as required.1 or 2 Module (75 mmX75 mm) |
| 237 | Supply and fixing modular blanking plate onthe existing modular plate & switch boxexcluding modular plate as required. |
| 238 | Supply and fixing of suitable size GI box withmodular plate and cover in front on surface or inrecess, including providing and fixing3 pin 5/6amps. modular socket outlet and 5/6 amps.modular switch, connection, painting etc. asrequired. |
| 239 | Supply and fixing of suitable size GI box withmodular plate and cover in front on surface or inrecess, including providing and fixing 6 pin15/16 & 5/6 amps. modular socket outlet and15/16 amps. modular switch, connection,painting etc. as required. |
| 240 | Supplying and fixing following way, three poleand neutral, sheet steel, TP MCB distributionboard, 415 volts,on surface /recess, completewith tinned copper busbar, neutral busbar,earth bar, din bar, detachable gland plate,interconnections, phosphatized and powderpainted including earthing etc. as required (Butwithout MCB / RCCB / Isolators). 4 way (4 + 12), Double door, horizontal type |
| 241 | Supplying and fixing 5 amps. to 32 amps.rating, 240 volts `C' series, miniature circuitbreaker (MCB)suitable for inductive load offollowing poles in the existing MCB DBcomplete with connections, testing andcommissioning etc. as required.single pole |
| 242 | Supplying & fixing single pole, blanking plate inthe existing MCB DB complete etc. as |
| 243 | Supplying and fixing20 amps, 240 volts,SPN,industrial type socket outlet, with 2poles and earth metal enclosed plug top alongwith 20 amps. \\"C\\" series, SP MCB in sheetsteel enclosure, on surface or in recess, withchained metal cover for the socket outlet, andcomplete with connections, testing and |
| 244 | Supplying and fixing following rating,four pole,415 volts, isolator in the existing MCB DBcomplete with connections, testing andcommissioning etc. as required.40 amps |
| 245 | Installation, testing and commissioning ofceiling fan including wiring the down rod ofstandard length (upto 30 cm.) with 1.5 sq. mm.FR PVC insulated, copper conductor, singlecore cable, including providing and fixingphenolic laminated sheet cover on the fan box |
| 246 | nstallation of exhaust fanupto 450 mm sweepin the existing opening, including making thehole to suit the size of the above fan, makinggood the damage, connections, testing,commissioning etc. as required. |
| 247 | Extra for fixing the louvers / shutterscomplete with frame fro exhaust fans of al |
| 248 | Supplying and fixing of call bell/buzzer suitablefor DC/AC single phase, 230 volts, complete asrequired. |
| 249 | Earthing with GI earth plate 600mm x 600 mmx 6mm thick including accessories andproviding masonary enclosure with cover platehaving locking arrangement and watering pipe2.7 m long etc, with charcoal/coke and salt asrequired. |
| 250 | Earthing withGI earth pipe4.5 mtr long, 40 mmdia including accessories and providingmasonary enclosure with cover plate havinglocking arrangement and watering pipe etc, withcoke and salt as required |
| 251 | Supplying and laying25 mm x 5 mm. G.I. stripat 0.50 M. below ground as strip earthelectrode, including connection and terminatingwith nut, bolt, spring, washer etc as required(jointing shall be done by overlapping and with 2sets of brass nut bolt and spring washer spaced |
| 252 | Providing and fixing 6 SWG dia G.I. wire onsurface or in recess for loop earthing as |
| 253 | Providing and laying earth connections fromearth electrode with 6 SWG dia G.I. wire in 15mm dia G.I. pipe from earth electrode as |
| 254 | Providing and fixing of circular / hexazonalcast ironor MS sheet box for ceiling fanclamp, of internal dia 140 mm, 73 mm height,top lid of 1.5 mm thick MS sheetwith it topsurface hacked for proer bonding, top lid shallbe screwed into the cost iron/MS sheet box bymeans of 3.3 mm dia round headed screws,one lock at the corners. Clamp shal be made of12 mm dia MS bar bent to shape as per |
| 255 | Providing and fixing M.V. danger notice plateof 200mmx150mm made of mild steel, atleast2mm thick and vitreous enamelled white on bothsides and with inscription single red colour onfront side as required. |
| 256 | Supply and installing of following size ofperforated Hot Dipped Galvanised Iron cabletrays (Galvanisation thickness not less 50miccrons) with preforation not more than 17.5%,in convenient sections, jointed with connectors,suspended from the ceiling with G.I. suspendersincluding G.I. bolts & nuts etc as required300mm width x 50mm depth x 1.6 mm |
| 257 | Providing, laying and fixing following dia RCCpipe NP2 class (light duty) in ground completewith RCC collars, jointing with cement mortar1:2 (1 cement : 2 fine sand) including trenching(75 cm deep) and refilling etc as required.100 mm dia |
| 258 | Add for Invertor Wiring in wiring Point forlight/Fan/Plug with 1.5 mm Cu Wire |
| 259 | S/F of single light wall bracket (Cat-AAA) onmatching M.D.F.E.G. board base etc. completein all respects.Category AA |
| 260 | S/F of recess/surface/pendent mounted 6 to 8watt LED down lighter having powder coateddie cast aluminium housing with heat sink,diffuser / reflector and driver set complete in all |
| 261 | S/F of LED Tube Light with batten suitable forup to 1x22 watt LED tube light fitting includingtube on surface complete in all respect. Category AAA |
| 262 | Supply of ceiling fan with fan motor of ACpermanent insulation, capacitor ratingconforming BEE 5 star rating and IS : 374/79and also comply with IS:1709/1984 with latestamendment the rated voltage 220/240 volts, 50HZ single phase AC, the fan assembled shouldconsists of down rod, blades, shackle canopiesetc and with double ball bearing system.BEE 5 star rating - 1200 mm sweep |
| 263 | Supply & fixing of Crimping, solder, less, copperton electroplated lugs of Dowel/ismail makesuitable for 1.5 sqmm to 6 sqmm cables,including tapping with insulating tape, etc. |
| 264 | Supply & fixing of electronic Fan regulator(Modular), 120-280 V, ISI marked, on theexisting switch board including makingconnections, required material, labour T&P etc.for proper completion of work to the satisfactionof Engineer of work. |
| 265 | Supply and laying of ISI marked aluminumconductor PVC / XLPE insulated armoured,served, sheathed cable 1100 volts grade at750 mm below ground level over a cushionof 75 mm thick sand around & protected withbrick on sides & top on surface the cable runshall be fixed on M.S. clamps etc. of suitablesize complete in all respect. The armouring ofthe cable shall be properly connected with the |
| 266 | Supply and fixing brass nickel platedcompression glands for PVC insulatedarmoured, served, sheathed cable includingrubber ring etc. complete in all respect. Thearmouring of the cable shall be properly50 sqmm 3 1/2 core |
| 267 | Supply & fixing of plam or pin type copper tinplated cable socket (lug) to the cable leads,insulating with tape and making connectionsetc. complete in all respects as per direction o |
| 268 | Construction of recess distribution board of allsizes including cutting of brick work providinglintel of suitable size & thickness plastering etc.with supply of all materials, labours, T & P etc.required for proper completion of work600x480x200 mm. size |
| 269 | Supply and fixing of factory fabricated M.S. boxin existing sunk with Godrej type almirah coverwith handle etc. fabricated from 18 SWG M.S.sheet duly painted with red oxide primerfollowed by two coats of synthetic enamel paintcomplete with necessary conduit entry andDP/TPN; fixing arrangement and provision forcompartment for loose wires, openable housingon the top and hold fast etc. including supply ofall material, labour and T & P etc. required for 600x480x200 mm. size |
| 270 | Supply & Erracetion of factory fabricated &wired metal clad dust and vermin proof floormounting, M.S. Channel Base with bottom andtop cable entreis Electrical control panel withTPN MCCB’s (Four Pole 36 KA with thermalmagnatic release) Switches complete andinstrument chamber etc. complete in allrespects. The instrument chamber shall beseparate and shall comprise of flush type digitalmetering system for phase to phase voltage andsingle phase voltage, current and otherparameters (KVA, P.F, KW etc) in each phasewith touch type selector switches for differentreadings, instrument fuses, current transformeretc. The panel board shall have suitablecapacity electrolytic aluminium busbars as perIS8623 or above istulated with heat shrinksleeving and mounted on non hygroscopicsupports such as CMC/BMC support withdeteachable side covers and shall be suitablefor extension on the sides. The MCCB’s shall becomplete with suitable cable end boxes,compression glands and indicating lamp onThe Job includes the grounting of the board asper directions of Engineer-in charge. All outgoings of 100 Amp and above shall have anAmmeter. The panel board shall be fabricatedwith CRCA sheet with a minimum thickness of1.6 mm/2 mm. Cubicle type switch board shallbe of cat A & B only. All bus bars shall be of aluminium, electrolyticgrade only. Maximum design density shall notexceed 1 Amps/Sqmm. All bus bars shall beinsulated with coloured heat shrinkable PVCsleeved. All bus bar supports shall be nonhygroscopic DMC/SMC supports.The panel shall be manufactured inconformance to requirements of local electricalinspector and it shall be contractorsresponsibility to get initial approval of drawingsand also final approval of complete electricalworks related to this section. The minimum clearances between bus barsshall be as follows :Phase to phase - minimum 20mmPhase to neutral-minimum 15mmCubical Panel Board ( MCCB Type) Main L.T. Panel (Meter Panel Board)Incoming : One (1) No.200Amp. MCCB-1No.Metering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeterwith control fuse & selector switch.One (1) No. (0-200A) 96 x 96 Sqmm CToperated Ammeter with selector switch, CTsOne (1) Set of Phase Indication Lamp.Bus Bar :One (1) No.200 A, TPN aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.100 Amp. MCCB- 1 No.63 Amp. MCCB- 3 No.Or outgoing as per site requirment(AS/SLD) |
| 271 | Supply and laying of 1800 mm x 900 mm x 12mm thick chequered rubber matting of tested |
| 272 | Supply and fixing 200 AMP four pole Mouldedcase type on load change over switch withenclosure(also suitable for panel mounting withextra cost of bus bar) including the cost oflabour, T & P , painting and other materialrequired for proper completion of the work asper direction and satisfaction of Engineer in |
| 273 | Supply and fixing of single phasemultifunctional electronic energy meter 10 to60 Amp. capacity fitted in integral box on wallcomplete in all respect. |
| 274 | Supply of AC 230/250 Volts, 50 Hz 55w 1400rpm exhaust fans including providing nuts,bolts, mounting frame and other accessoriesincluding connections etc. complete as required.300mm sweep. |
| 275 | Providing and fixing white vitreouschina pedestal type water closet( European type W.C. pan ) with seatand lid, 10 litre low level white P.V.C.flushing cistern, including flush pipe,with manually controlled device(handle lever) conforming to IS : 7231,with all fittings and fixtures complete,including cutting and making good thewalls and floors whereverrequired:W.C. pan with ISI marked |
| 276 | Providing and fixing wash basin withC.I. brackets, 15 mm C.P. brass pillartaps, 32 mm C.P. brass waste ofstandard pattern, including painting offittings and brackets, cutting andmaking good the walls whereverrequire a) White Vitreous China Flat backwash basin size 550x 400 mm withsingle 15 mm C.P. brass pillar tappillar |
| 277 | Providing and fixing flexible P.V.C.waste pipe for sink or wash basinFelxible pipe 1b) 40mm dia |
| 278 | Providing and fixing 600x450 mmbeveled edge mirror of superior glass(of approved quality) complete with 6mm thick hard board ground fixed towooden cleats with C.P. brass screws |
| 279 | Providing and fixing 8 mm diaC.P./S.S. Jet with flexible tube upto 1meter long with S.S. triangular platefor Eureopean type W.C. of quality andmake as approved by engineer-incharge.DSR 2023SCHEDULE OF QUANTITIES FOR PLUMBING WORKSPROJECTTYPE-GARBAGE OFFICE PLUMBING (SCHEDULED ITEMS AS PER D.S.R 2023)COST INDEXSANITARY FIXTURES & ACCESSORIES : I15mm nominal bore |
| 280 | Providing and fixing CP Brass 32 mmsize Bottal Trap of approved quality& make and as per thedirection ofEnginer-in-charge |
| 281 | Providing & fixing PTMT towl railcomplete with brackets fixed towooden cleats with cp brass screwswith concealed fitting arrangement ofapproved quality and colour. 600 mm.long towl rail length of 645 mm. width78 mm. and effective height of 88 mm,weighing not less than 190 gms. |
| 282 | Providing and fixing PTMT Liquidsoap container 109 mm wide ,125 |
| 283 | Providing and fixing of UPVC SWRring fit pipe of class B of ISI markConfirming to IS code 13592 (makeprince, supreme finolex) in internalworks of toilet and RWP etc. includingfixing with rubber rings etc. includingcost of all material, labour etc.110mm diameter |
| 284 | 90mm diameter |
| 285 | Haunching of SWR pipe 90mm or110mm with pcc 1:2:4 cementconcrete ( 1 cement:2 coarse sand:4 |
| 286 | Supply and fixing of UPVC S.W.R.pipe nahni trap size 100x75,110/90mm confirming to IS-14735 selfcleaning design fixed in PCC 1:2:4 andsupply and fixing of 125 mm dia heavyduty CP brass jali. |
| 287 | Supply and fixing of UPVC S.W.R.Cowel confirming to IS-14735.Size 75/90 mm |
| 288 | Size 110 mm |
| 289 | Making khurras 45x45 cm withaverage minimum thickness of 5 cmcement concrete 1:2:4 (1 cement : 2coarse sand : 4 graded stoneaggregate of 20 mm nominal size)over PVC sheet 1m x 1 m x 400micron, finished with 12 mm cementplaster 1:3 (1 cement : 3 coarse sand)and a coat of neatcement,punning,rounding the edgesa) 110mm |
| 290 | Providing and fixing to the inlet mouthof rain water pipe cast iron grating 15cm diameter and weighing not lessthan 440 grams. |
| 291 | Providing and fixing ChlorinatedPolyvinyl Chloride (CPVC) pipes,having thermal stability for hot & coldwater supply including all CPVC plain& brass threaded fittings includingfixing the pipe with clamps at 1.00mspacing. This includes jointing ofpipes & fittings with one step CPVCsolvent cement and testing of jointscomplete as per direction of Enginee20mm dia nominal outer dia pipes |
| 292 | 25mm dia nominal outer dia pipes |
| 293 | 32mm dia nominal outer dia pipes |
| 294 | 40mm dia nominal outer dia pipes |
| 295 | Providing and fixing ChlorinatedPolyvinyl Chloride (CPVC) pipes,having thermal stability for hot & coldwater supply including all CPVC plain& brass threaded fittings i/c fixing thepipe with clamps at 1.00m spacing.This includes jointing of pipes & fittingswith one step CPVC solvent cementand the cost of cutting chases andmaking good the same includingtestiang of joints complete as perdirection of Engineer in Charge.Concealed work including cuttin16mm dia nominal outer dia pipes |
| 296 | 20mm dia nominal outer dia pipes |
| 297 | Providing and fixing 45 cm longunplasticised PVC connection pipewith brass unions.45 cm lengthi) 15mm nominal bore |
| 298 | Providing and fixing 45 cm longunplasticised PVC connection pipewith brass unions.45 cm lengthi) 15mm nominal bore |
| 299 | Providing & fixing C.P. brass long bodybib cock of approved qualityconforming to IS standards andweighing not less than 690 gms.15mm nominal bore |
| 300 | Providing and fixing gun metal gatevalve with wheel of approvedquality(screwed end)..25mm dia nominal bor |
| 301 | Providing and fixing gun metal gatevalve with wheel of approve |
| 302 | Providing and fixing ball valve (brass)of approved quality, High or lowpressure, with plastic floats complete25 mm nominal bore |
| 303 | Providing and placing on terrace (at allfloor levels) polyethylene waterstorage tank of approved brand andmanufacture with cover and suitablelocking arrangement and makingnecessary holes for inlet, outlet and 18.48For 500 litres |
| 304 | Excavating trenches in all kind of soilof required width for pipes, cables etc.including excavation for sockets anddressing of sides, ramming of bottoms, in layers not exceeding 20cm in depthincluding consolidating each depositedlayer by ramming, watering, etc &disposig of surplus excavated soil asdirected within a lead of 50m.a) Pipes 80mm to 300mm diameter. |
| 305 | Providing and fixing UPVC S.W.RGully trap grade 'A' complete with C.I.grating brick masonry chamber andwater tight C.I.cover frame of 300 x300mm. size (inside) square mouthtraps of \\"P\\" or \\"S\\" type traps.a) 100 x 150 mm. dia |
| 306 | Constructing brick masonry manholein cement mortar 1:4 (1 cement :4coarse sand) RCC top slab with 1:2:4mix (1 cement :2 coarse sand :4graded stone aggregate 20mmnominal size), foundation concrete1:4:8 mix (1 cement :4 coarse sand :8graded stone aggregate 40mmnominal size) inside plastering 12mmthick with cement mortar 1:3 (1cement :3 coarse sand) finished withfloating coat fo neat cement andmaking channels in cement concrete1:2:4 (1 cement :2 coarse sand :4graded stone aggregate 20mm nminalsize) finished with a floating coat ofneat cement complete as per standard 19.7Inside size 900x800mm and 500mmdeep including CI cover with frame 19.7.1With FPS bricks of class designation |
| 307 | Extra for depth of man hole size |
| 308 | Providing M.S. foot rests includingfixing in manholes with20x20x10 cm cement concrete blocks1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20mm nominal size) as perstandard designWith 20x20 mm square bar |
| 309 | Providing and fixing of upvc SWRring fit pipe of class B of ISI markConfirming to IS code 13592 (makeprince, supreme finolex) in internalworks of toilet and RWP etc. includingfixing with rubber rings etc. includingcost of all material, labour etc.complete.. b) 160mm diameter |
| 310 | Haunching of SWR pipe 90mm or110mm or 160mm with pcc 1:5:10cement concrete ( 1 cement:2 coarsesand:4 stone grit) AR |
| 311 | Earth work in excavation bymechanical means (Hydraulicexcavator)/ manual means over areas(exceeding 30 cm in depth, 1.5 m inwidth as well as 10 sqm on plan)including getting out and disposal ofexcavated earth lead upto 50 m andlift upto 1.5 m, as directed byEngineer-in charge. 2.6.1 All kinds of |
| 312 | Excavating, supplying and filling oflocal earth (including royalty) bymechanical transport upto a lead of5km also including ramming andwatering of the earth in layers notexceeding 20 cm in trenches, plinth,sides of foundation etc. complete. |
| 313 | Providing and laying in positioncement concrete of specified gradeexcluding the cost of centering andshuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand(zone-III) derived from naturalsources : 8 graded stone aggregate20 mm nominal sizederived from natural sources) |
| 314 | Supplying and filling in plinth withsand under floors, including watering,ramming, consolidating and dressing |
| 315 | Providing and injecting chemicalemulsion for Preconstructionalantltermite treatment and creating achemical barrier under and alroundthe column pitswall trenchesbasement excavation top surface Ifplinth filling junction of wall and flooralong the extemal perimer of bindingexpansion jolnts,surroundings ofpipes and conduit etc. complete(Plintharea of the building at ground flooronly shall be measured as per I.S.6313 (Part II 1981) Aldrineemulsifiable concentrate or any otherapproved material such asHepthachlor or chlordance will beused. The rateof applications ofchemical emulsion sl1all be asFollows :. (1) Treatment forMaS9nary& foundatiion 5 Liters perSq.m. (2) Back fill Inimmediatecontract with foundation 7.5Litres per Sq.M. (3) Treatment,of Topsurface of plinth filling 5 LitresperSq.M. (4) Treatment of soli alongExternal Perimerter of Building7.50 |
| 316 | Reinforced cement concrete work inbeams, suspended floors, roofshaving slope up to 15° landings,balconies, shelves, chajjas, lintels,bands, plain window sills, staircasesand spiral stair cases above plinthlevel up to floor five level, excludingthe cost of centering, shuttering,finishing and reinforcement with1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from naturalsources : 3 graded stone aggregate20 mm nominal size derived from |
| 317 | Reinforced cement concrete work inbeams, suspended floors, roofshaving slope up to 15° landings,balconies, shelves, chajjas, lintels,bands, plain window sills, staircasesand spiral stair cases above plinthlevel up to floor five level, excludingthe cost of centering, shuttering,finishing and reinforcement with1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from naturalsources : 3 graded stone aggregate20 mm nominal size derived fromnatural sources). sunshade SLAB (a) Ground Floor |
| 318 | Providing and laying in position readymixed or site batched design mixcement concrete for reinforcedcement concrete work; using coarseaggregate and fine aggregate derivedfrom natural sources, PortlandPozzolana / Ordinary Portland/Portland Slag cement, admixtures inrecommended proportions as per 1S:9103 to accelerate / retard setting ofconcrete, to improve durability andworkability without impairing strength;including pumping of concrete to siteof laying, curing, carriage for all leads;but excluding the cost of centering,shuttering, finishing andreinforcement as per direction of th |
| 319 | Providing and laying in position readymixed or site batched design mixcement concrete for reinforcedcement concrete work; using coarseaggregate and fine aggregate derivedfrom natural sources, PortlandPozzolana / Ordinary Portland/Portland Slag cement, admixtures inrecommended proportions as per 1S:9103 to accelerate / retard setting ofconcrete, to improve durability andworkability without impairing strength;including pumping of concrete to siteof laying, curing, carriage for all leads;but excluding the cost of centering,shuttering, finishing andreinforcement as per direction of th |
| 320 | Steel reinforcement for R.C.C. workincluding straightening, cutting,bending, placing in position andbinding all complete DSR 5.22(a) Ground Floor |
| 321 | Brick work with common burnt clay(non modular) bricks of classdesignation 150 in foundation andplinth in:Cement mortar 1:6 (1 cemen |
| 322 | Brick work with common burnt clay(non modular) bricks of classdesignation 150 in superstructureabove plinth level up to floor V level inall shapes and sizes in Cementmortar 1:6 (1 cement : 6 coarse sand) |
| 323 | Brick work with common burnt clay(non modular) bricks of classdesignation 150 in superstructureabove plinth level up to floor V level inall shapes and sizes in Cementmortar 1:4 (1 cement : 4 coarse sand) 6.4.1Ground Floor |
| 324 | Providing and laying damp-proofcourse 40mm thick with cementconcrete 1:2:4 (1 cement : 2 coarsesand (zone-III) derived from naturalsources : 4 graded stone aggregate12.5mm nominal size derived from |
| 325 | Providing & applying a coat ofresidual petroleum bitumen of gradeof VG-10 of approved quality using1.7kg per square metre on dampproof course after cleaning thesurface with brushes and finally with apiece of cloth lightly soaked in |
| 326 | Providing and laying integral cementbased water proofing treatmentincluding preparation of surface asrequired for treatment of roofs,balconies, terraces etc consisting offollowing operations:Applying a slurrycoat of neat cement using 2.75kg/sqm ofcement admixed with water proofingcompound conformingto IS. 2645 and approved by Engineerin-charge over the RCCslab including adjoining walls upto300 mm height includingcleaning the surface before treatment.(b) Laying brick bats with mortar usingbroken bricks/brick bats25 mm to 115 mm size with 50% ofcement mortar 1:5 (1cement : 5 coarse sand) admixed withwater proofingcompound conforming to IS : 2645and approved by Engineer in-chargeover 20 mm thick layer of cementmortar of mix 1:5(1 cement :5 coarse sand ) admixedwith water proofingcompound conforming to IS : 2645 |
| 327 | Providing and fixing ISI marked flushdoor shutters conforming to IS : 2202(Part I) decorative type, core of blockboard construction with frame of 1stclass hard wood and well matchedteak 3 ply veneering with verticalgrains or cross bands and faceveneers on both faces of shutters.(a) Ground Floor |
| 328 | Structural steel work in single section,fixed with or without connecting plate,including cutting, hoisting, fixing inposition and applying a priming coatof approved steel primer all complete.a Providing & fixing of hold fast forchaukhats of doors and windows. |
| 329 | Structural steel work in single section,fixed with or without connecting plate,including cutting,hoisting, fixing in position andapplying a priming coat of approvedsteel primer all complete.Providing & fixing of door / windows |
| 330 | Z-Section steel windows |
| 331 | Providing & fixing of hold fast forchaukhats of doors and windows |
| 332 | Fixing of steel or wooden chaukhats in position.(a) Ground Floor(a) Door chaukhats |
| 333 | 12 mm cement plaster of mix 1:6 (1cement: 6 coarse sand) DSR 13.4.2(a) Ground Floor |
| 334 | 12 mm cement plaster of mix 1:6 (1cement: 6 coarse sand) DSR 13.4.2(a) Ground Floor |
| 335 | Providing and laying Ceramic glazedfloor tiles of size 300x300 mm(thickness to be specified by themanufacturer) of 1st qualityconforming to IS : 15622 of approvedmake in colours such as White, Ivory,Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), Jointingwith grey cement slurry @ 3.3 kg/sqmincluding pointing the joints with whitecement and matching pigment etc.,DSR 11.37(a) Ground Floor |
| 336 | Providing and fixing Ist qualityceramic glazed wall tiles conformingto IS: 15622 (thickness to be specifiedby the manufacturer), of approvedmake, in all colours, shades exceptburgundy, bottle green, black of anysize as approved by Engineer-inCharge, in skirting, risers of steps anddados, over 12 mm thick bed ofcement mortar 1:3 (1 cement : 3coarse sand) and jointing with greycement slurry @ 3.3kg per sqm,including pointing in white cementmixed with pi |
| 337 | Making grooves 10 to 12mm wide x 8mm deep in plaster of the walls or inceiling vertically or horizontally asrequired. |
| 338 | Making Drip course 10 to 12mm widex 8 mm deep in plaster of the walls orin ceiling vertically or horizontally asrequired. |
| 339 | Cement concrete flooring 1:2:4 (1cement : 2 coarse sand : 4 gradedstone aggregate) finished with afloating coat of neat cement, includingcement slurry, but excluding the costof nosing of steps etc. complete.11.3.1 40 mm thick with 20 mmnominal size ston |
| 340 | Construction of drain alongwith apron |
| 341 | Finishing with Epoxy paint (two ormore coats) at all locations preparedand applied as per manufacturer'sspecifications including appropriatepriming coat, preparation of surface,etc. complete. On steel work 13.52.1(a) Ground Floor |
| 342 | Finishing with Deluxe Multi surfacepaint system for interiors andexteriors using Primer as permanufacturers specifications Paintingwood work with Deluxe Multi SurfacePaint of required shade. Two or morecoat applied @ 0.90 ltr/10 sqm overan under coat of primer [email protected] ltr/10 sqm of approved brandand manufa |
| 343 | Finishing walls with Premium AcrylicSmooth exterior paint with Siliconeadditives of required shade : Newwork (Two or more coats applied @1.43 ltr/ 10 sqm over and includingpriming coat of exterior primer applied@ 2.20 kg/ 10 sqm).(DSR13.47.1)(a) Ground Floor |
| 344 | Distempering with oil bound washabledistemper of approved brand andmanufacture to give an even shade :13.41.1 New work (two or more coats)over and including water thinnablepriming coat with cement primer DSR 13.41(a) Ground Floor |
| 345 | Distempering with oil bound washabledistemper of approved brand andmanufacture to give an even shade :13.41.1 New work (two or more coats)over and including water thinnablepriming coat with cement primer DSR 13.41(a) Ground Floor |
| 346 | Providing and applying white cementbased putty of average thickness 1mm, of approved brand andmanufacturer, over the plastered wallsurface to prepare the surface evenand smooth c |
| 347 | Providing & fixing glass panes withputty and glazing clips in steel doors,windows, clerestory windows, allcomplete with :4.0 mm thick glasspanesDSR 10.30(a) Ground Floor |
| 348 | Providing & fixing Stainless steelsliding door bolts ISI marked anodised(anodic coating not less than gradeAC 10 as per IS : 1868) transparent ordyed to required colour or shade withnuts and screws etc complete. (a)250mm x 16mm .MR(a) Ground Floo |
| 349 | Providing and fixing stainless steeltowerbolts (barrel type) withnecessary screws etc. complete MR(a) Ground Floor |
| 350 | Providing and fixing stainless steelhandles with screws etc. complete (a)150 mm MR(a) Ground Floor |
| 351 | Centering and shuttering includingstrutting, propping etc. and removal ofform work for :A Lintels, beams, plinth beams, girders,bressumers and cantilevers |
| 352 | Suspended floors, roofs, landings,balconies and accessplatform |
| 353 | Wiring for light point/fanpoint/exhaust fan point/call bellpointwith 1.5 sqmm FR PVCinsulatedcopper conductor singlecore cable in surface / recessed PVCconduit,with modular switch, modularplate, suitable G.I. box and earthingthe point with 1.5 sqmm FR PVCinsulated |
| 354 | Wiring for twin control light pointwith 1.5 sqmm FR PVC insulatedcopper conductor single core cablein surface/ recessed PVC conduit, 2way modular switch, modular plate,suitable G.I. box and earthing the |
| 355 | Wiring forcircuit / submain wiringalongwith earth wire with thefollowing sizes of PVCinsulated,copper conductor singlecore cable in surface/ recessed 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. PVC e) |
| 356 | 2 x 4 sq.mm. + 1 x 4 sq.mm. Earth |
| 357 | 2 x 6 sq.mm. + 1 x 6 sq.mm. Earthwire |
| 358 | Supply and fixing of following sizes ofPVC conduit along with accessoriesin surface/recess including cuttingthe wall and making good the samein case of |
| 359 | Supplying and drawing following pair0.5 mm dia FRLS PVC insulatedannealed copper conductor,unarmored telephone cable in theexistin |
| 360 | Supplying and fixing metal box offollowing size (nominal size) onsurface or recess with suitable size ofphenolic laminated sheet cover infromt including paintingetc. as 75 mm x 75 mm x 60 mm dee |
| 361 | Supplying and fixing following size /modules, GI box alongwith modularbase & cover plate for modularswitches in recess etc. as required.1 or 2 Module (75 mmX75 mm) |
| 362 | Supply and fixing modular blankingplate on the existing modular plate &switch box excluding modular plateas required. |
| 363 | Supply and fixing of suitable size GIbox with modular plate and cover infront on surface or in recess,including providing and fixing3 pin5/6 amps. modular socket outletand 5/6 amps. modular switch,connection, painting etc. as required. |
| 364 | Supply and fixing of suitable size GIbox with modular plate and cover infront on surface or in recess,including providing and fixing3 pin5/6 amps. modular socket outletand 5/6 amps. modular switch,connection, painting etc. as required. |
| 365 | Supplying and fixing following way,three pole and neutral, sheet steel,TP MCB distribution board, 415volts,on surface /recess, completewith tinned copper busbar, neutralbusbar, earth bar, din bar,detachable gland plate,interconnections, phosphatized andpowder painted including earthingetc. as required (But without MCB /4 way (4 + 12), Double door, |
| 366 | Supplying & fixing single pole,blanking plate in the existing MCB |
| 367 | 16 Installation of exhaust fanupto 450mm sweep in the existing opening,including making the hole to suit thesize of the above fan, making goodthe damage, connections, testing |
| 368 | Extra for fixing the louvers /shutters complete with frame |
| 369 | Earthing with GI earth plate 600mmx 600 mm x 6mm thick includingaccessories and providing masonaryenclosure with cover plate havinglocking arrangement and watering |
| 370 | Earthing withGI earth pipe4.5 mtrlong, 40 mm dia includingaccessories and providing masonaryenclosure with cover plate havin |
| 371 | Supplying and laying25 mm x 5 mm.G.I. strip at 0.50 M. below ground asstrip earth electrode, includingconnection and terminating with nut,bolt, spring, washer etc as required(jointing shall be done by overlapping |
| 372 | Providing and fixing 6 SWG dia G.I.wire on surface or in recess forloop earthing as required. |
| 373 | Providing and laying earthconnections from earth electrode with6 SWG dia G.I. wire in 15 mm diaG.I. pipe from earth electrode asrequired |
| 374 | S/F of single light wall bracket (CatAAA) on matching M.D.F.E.G. boardbase etc. complete in all respects.Category AA |
| 375 | S/F of recess/surface/pendentmounted 6 to 8 watt LED downlighter having powder coated diecast aluminium housing with heatsink, diffuser / reflector and driver setcomplete in all respect Category AAA |
| 376 | S/F of LED Tube Light with battensuitable for up to 1x22 watt LEDtube light fitting including tube onCategory AAA |
| 377 | Supply and fixing brass nickel platedcompression glands for PVCinsulated armoured, served,sheathed cable including rubber ringetc. complete in all respect. The50 sqmm 3 1/2 core |
| 378 | Construction of recess distributionboard of all sizes including cutting ofbrick work providing lintel of suitablesize & thickness plastering etc. withsupply of all materials, labours, T & Petc. required for proper completion ofwork. 600x480x200 mm. size |
| 379 | Supply and fixing of factory fabricatedM.S. box in existing sunk with Godrejtype almirah cover with handle etc.fabricated from 18 SWG M.S. sheetduly painted with red oxide primerfollowed by two coats of syntheticenamel paint complete withnecessary conduit entry andDP/TPN; fixing arrangement andprovision for compartment for loosewires, openable housing on the topand hold fast etc. including supply ofall material, labour and T & P etc.required for proper completion of thework.600x480x200 mm. size |
| 380 | Supply of AC 230/250 Volts, 50 Hz55w 1400 rpm exhaust fansincluding providing nuts, bolts,mounting frame and otheraccessories including connectionsetc. complete as required. 300mm sweep. |
| 381 | Providing and fixing water closet squatting pan(Indian type W.C. pan ) with 100 mm sand castIron P or S trap, 10 litre low level white P.V.C.flushing cistern, including flush pipe, with manuallycontrolled device (handle lever) conforming to IS :7231, with all fittings and fixtures complete,including cutting and making good the walls andfloors wherever requireda) Orissa Pattern W.C. pan of size 580x 440m withintegral type foot rests flush pipe and over flowarrangement |
| 382 | Same as above but for European type W.C. panwith black plastic seat and lid. Make |
| 383 | Providing & fixing white vitreous china wash basinwith C.I. brackets painted white, 15mm C.P. brasspillar taps, C.P. brass chain with rubber plug,32mm C.P. brass waste of standard patternincluding cutting & making good the walls wherevera) Flat back wash Basin size 550x400 mm withsingle 15mm C.P. brass pillar tap |
| 384 | Providing and fixing flexible P.V.C. waste pipe forsink or wash basin including PVC waste fittingsSemi rigid pipe 17.28.1a) 32mm dia |
| 385 | b) 40mm dia |
| 386 | Providing and fixing white vitreous china flat backhalf stall urinal of size 580x380x350 mm withwhite PVC automatic flushing cistern, with fittings,standard size C.P. brass flush pipe, spreaderswith unions and clamps (all in C.P. brass) withwaste fitting as per IS :2556, C.I. trap with outletgrating and other couplings in C.P. brassincluding painting of fittings and brackets, cuttingand making good the walls and floors whereverrequiredSCHEDULE OF QUANTITIES FOR PLUMBING WORKSPROPOSED TYPE - TOILET (SCHEDULED ITEMS AS PER D.S.R. 2023)DISTT. CODE-107106/107a) Single half stall urinal with 5 litre P.V.C.automatic flushing cistern |
| 387 | Providing & fixing 600x450mm bevelled edgemirror of superior glass (of approved quality)complete with 6mm thick asbestos cement sheetground fixed to wooden cleats with C.P. Brass |
| 388 | Providing & fixing PTMT towl rail complete withbrackets fixed to wooden cleats with cp brassscrews with concealed fitting arrangement ofapproved quality and colour. 600 mm. long towlrail length of 645 mm. width 78 mm. and effectiveheight of 88 mm, weighing not less than 190 gms. |
| 389 | Providing and fixing PTMT Liquid soap container109 mm wide ,125 mm high and 112 mm distance |
| 390 | Providing and Fixing C.P. brass Ablution healthfaucet assembly with 1.2 m long braided PVChose with mounting bracket fixed on wal |
| 391 | Providing and fixing C.P. brass Two-way anglevalve for EWC points & for fixing Ablution HealthFauct of approved quality conforming to IS:8931.15 mm nominal bore |
| 392 | Providing and fixing of upvc SWR ring fit pipe ofclass B of ISI mark Confirming to IS code 13592(make prince, supreme finolex) in internal works oftoilet and RWP etc. including fixing with rubberrings etc. including cost of all material, labour etc.complete.including excavation & trenches etccompletea) 110mm diameter |
| 393 | Haunching of SWR pipe 90mm or 110mm withpcc 1:5:10 cement concrete ( 1 cement:2 coarsesand:4 stone grit) ch-25 item no.2 |
| 394 | Supply and fixing of UPVC S.W.R. pipe nahni trapsize 100x75,110/90 mm confirming to IS-14735self cleaning design fixed in PCC 1:2:4 and supplyand fixing of 125 mm dia heavy duty CP brass jali |
| 395 | Supply and fixing of UPVC S.W.R. Cowelconfirming to IS-14735.(ch-23 item no.38)a) 100mm |
| 396 | b) 75mm |
| 397 | Providing and fixing on wall face unplasticisedRigid PVC rain water pipes conforming to IS :13592 Type A including jointing with seal ringconforming to IS : 5382 leaving 10 mm gap forthermal expansion . (i) Single socketed pipes.a) 110mm diameter |
| 398 | Making khurras 45x45 cm with average minimumthickness of 5 cm cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stoneaggregate of 20 mm nominal size) over PVCsheet 1m x 1 m x 400 micron, finished with 12 mmcement plaster 1:3 (1 cement : 3 coarse sand) anda coat of neat cement,punning,rounding the edgesand making and finishing the outlet complete.a) 110mm |
| 399 | Providing and fixing unplasticised -PVC pipe clipsof approved design to unplasticised - PVC rainwater pipes by means of 50x50x50mm hard woodplugs, screwed with M.S. screws of requiredlength including cutting brick work and fixing incement mortar 1:4 (1 cement : 4 coarse sand) andmaking good the wall etc. complete.a) 110mm |
| 400 | Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brassthreaded fittings including fixing the pipe withclamps at 1.00m spacing. This includes jointing ofpipes & fittings with one step CPVC solventcement and testing of joints complete as perdirection of Engineer in Charge.(internal work)i) Exposed on wall25mm dia nominal outer dia pipes |
| 401 | Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brassthreaded fittings i/c fixing the pipe with clamps at1.00m spacing. This includes jointing of pipes &fittings with one step CPVC solvent cement andthe cost of cutting chases and making good thesame including testiang of joints complete as perdirection of Engineer in Charge. Concealed workincluding cutting chases and making good thewalls etc. 16mm dia nominal outer dia pipes |
| 402 | 20mm dia nominal outer dia pipes |
| 403 | Providing and fixing 45 cm long unplasticised PVCconnection pipe with brass unions.a) 15mm nominal bore |
| 404 | Providing & fixing CP brass bib cock of approvedquality conforming to IS 8931a) 15mm nominal bore |
| 405 | Providing & fixing C.P. brass long body bib cockof approved quality conforming to IS standardsand weighing not less than 690 gms.a) 15mm nominal bore |
| 406 | Providing & fixing C.P. brass angle valve for basinmixer and gyser points of approved qualityconforming to IS 8931a) 15mm nominal bore |
| 407 | Providing and fixing ball valve (brass) of approvedquality complete. (High or low pressure withplastic floats).a) 25mm. Nominal bore |
| 408 | Providing and fixing brass stop cock of approvedquality.a) 15 mm nominal bore |
| 409 | b)20 mm nominal bore |
| 410 | Providing and fixing gun metal gate valve withwheel of approved quality.a) 25mm dia nominal bore |
| 411 | Providing and placing on terrace (at all floorlevels) polyethylene water storage tank ofapproved brand and manufacture with cover andsuitable locking arrangement and makingnecessary holes for inlet, outlet and overflowpipes but without fittings and the base support fortank. Capacity 1700 litre |
| 412 | Excavating trenches in all kind of soil of requiredwidth for pipes, cables etc. including excavationfor sockets and dressing of sides, ramming ofbottoms, depth upto 1.5 m. including getting outthe excavated soil & then returning the soil asrequired, in layers not exceeding 20cm in depth includingconsolidating each deposited layer by ramming,watering, etc & disposig of surplus excavated soilas directed within a lead of 50m.a) Pipes 80mm to 300mm diameter |
| 413 | Providing and fixing of UPVC SWR ring fit pipe ofclass B of ISI mark Confirming to IS code 13592(make prince, supreme finolex) in internal works oftoilet and RWP etc. including fixing with rubberrings etc. including cost of all material, labour etc.complete including excavtion trenches etc comp. ARa) 110mm diameter |
| 414 | b) 160mm diameter |
| 415 | Haunching of SWR pipe 90mm or 110mm or160mm with pcc 1:5:10 cement concrete ( 1cement:2 coarse sand:4 stone grit) AR |
| 416 | Providing and fixing square mouth S.W. Gully trapgrade 'A' complete with C.I. grating brick masonrychamber with F.P.S. bricks of class designation 75and water tight C.I. cover with frame of 300 x300mm. size (inside) the weight of cover to be notless than 4.50 Kg and frame to be not less than2.70 Kg as per standard design.a) 150 x 100 mm. size P type |
| 417 | Constructing brick masonry manhole in cementmortar 1:4 (1 cement :4 coarse sand) RCC topslab with 1:2:4 mix (1 cement :2 coarse sand :4graded stone aggregate 20mm nominal size),foundation concrete 1:4:8 mix (1 cement :4 coarsesand :8 graded stone aggregate 40mm nominalsize) inside plastering 12mm thick with cementmortar 1:3 (1 cement :3 coarse sand) finished withfloating coat fo neat cement and making channelsin cement concrete 1:2:4 (1 cement :2 coarsesand :4 graded stone aggregate 20mm nminalsize) finished with a floating coat of neat cementcomplete as per standard design 19.7a) Inside size 90x80 cm & 45 cm deep includingC.I. cover with frame (light duty) total wt. of cover& frame to be not less than 38 Kg (wt. of cover 23Kg & wt. of frame 15 Kg. |
| 418 | b) Extra for depth of man hole size 90x80 cm |
| 419 | Providing M.S. foot rests including fixing inmanholes with 20x20x10 cm cement concreteblocks 1:3:6 (1 cement:3 coarse sand :6gradedstone aggregate 20 mm nominal size) as perstandard design19.15With 20x20 mm square bar |
| 420 | Earth work in surface excavationnot exceeding 30cm in depth butexceeding 1.5m in width as wellas 10 sqm on plan includinggetting out & disposal ofexcavated earth upto 1.5m asdirected by Engineer in charge Allkind of soil. In all kind of soil upto 1.5m depth |
| 421 | In all kind of soil upto 1.5m to3.0m. Depth |
| 422 | Providing and laying in positioncement concrete of specifiedgrade excluding the cost ofcentering and shuttering - Allwork up to plinth level :1:4:8 (1Cement : 4 coarse sand (zone-III)derived from naturalsources : 8 graded stoneaggregate 20 mm nominal size |
| 423 | First class brick work in 1:6cement and coarse sand mortarin foundation & plinth includingsupply of all materials, labour andT & P etc reqiored for propercompletion of the work |
| 424 | Reinforced cement concrete workin beams, suspended floors, roofshaving slope up to 15° landings,balconies, shelves, chajjas,lintels, bands, plain window sills,staircases and spiral stair casesabove plinth level up to floor fivelevel, excluding the cost ofcentering, shuttering, finishingand reinforcement with 1:1.5:3 (1cement : 1.5 coarse sand(zoneIII) derived from natural sources :3 graded stone aggregate 20 mmnominal size derived from naturalsources). SLAB |
| 425 | Steel reinforcement for R.C.C.work including straightening,cutting, bending, placing inposition and binding all complete |
| 426 | 15 mm cement plaster of mix 1:6(1 cement: 6 coarse sand) |
| 427 | Providing M.S. foot restsincluding fixing in manoholes with20x20x10 cm cement concreteblocks 1:3:6 (1cement : 3 coarsesand : 6 graded stone aggregate20mm nominal size) as perstandard design:(With 20x20mm |
| 428 | Providing and fixing C.I. tee at theinlet and outlet of septic tank. |
| 429 | P & F of SWR ring fit pipe ofclass B of ISI mark confirming toIS code 13592(makeprince,supreme finolex) in internalworks of toilet and RWP etc .Including fixing with rubber ringsetc including cost of allmaterial,labour rtc. Complete For |
| 430 | Making soak pit 2.5 m diameter3.0 metre deep with 45 x 45 cmdry brick honey comb shaft withbricks and S.W. drain pipe 100mm diameter, 1.8 m longcomplete as per standard designWith bricks of class designation |
| 431 | Cement concrete flooring 1:2:4 (1cement : 2 coarse sand : 4graded stone aggregate) finishedwith a floating coat of neatcement, including cement slurry,but excluding the cost of nosingof steps etc. complete. 11.3.1 40mm thick with 20 mm nominalsize stone aggregate |
| 432 | cost of washing pit |
| 433 | cost of houricultre work (pera 5.9.1) |
| 434 | Add 18%GST on civil work for STP plant |
| 435 | add 1% coutingincies |
| 436 | ADD 1.45 % FOR ARCHITECTURAL & STRUCTURALCONSULTANCY CHARGES TOTAL A |
| 437 | Earthwork in excavation in ordinary soil with lift 1.5m & lead upto 30m etc including all work complete |
| 438 | Earth work in filling upto 8 km distance frome site including loading unloading cartage etc complete (anallises Rate) |
| 439 | P.C.C 1:4:8 with in cement and fine sand and 40 mm gauge brick ballast in all work complete |
| 440 | Supply and filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete |
| 441 | Providing and injecting chemical emulsion for preconstructional antilermile tratment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the external perimeter in all complete work treatment of soil along external perimeter of building 7.5 litre/sqm treatment of soil under apron along external perimeter 5 litre/sqm |
| 442 | C.C. 1:1.5:3 cement course sand and 20 mm gauge stone grit with micron polythene (without dovel bar) all work complete |
| 443 | R.C.C. 1:1.5:3 cement course sand and 20 mm gauge stone grit all work complete (S.I. No. 284(a)) |
| 444 | C.C. 1:1.5:3 cement course sand and 20 mm gauge stone grit with micron polythene (without dovel bar) all work complete |
| 445 | Mild steel work in all work complete (S.I. No. 504) |
| 446 | M-150 class brick work in 1:6 cement and fine sand mortar in all complete |
| 447 | M-150 class brick work in 1:6 cement and fine sand mortar in all complete |
| 448 | 15mm thick plaster 1:4 cement and Fine sand mortar in all complete |
| 449 | Finishing wall with water proof paint weather coat Two coat with all material labour T&P etc all complete |
| 450 | Appying priming coat 13.50.2 with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood in all complete work |
| 451 | C.C 1:2:4 cement core. sand and 20 mm stone grit in all complete (S.I. No. 279 (a)) |
| 452 | 22mm thick plaster 1:4 cement and Fine sand mortar in all complete |
| 453 | Steel work in built up tubular round square or rectangular hollow tubes etc trusses in all complete work |
| 454 | Extra for providing and fixing wind ties of 40x6mm flat iron section |
| 455 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with with polymer coated J or L hook in all complete work |
| 456 | Providing and fixing 15cm wide 45cm overall semicircular plain G.S sheet gutter with iron brackets 40x3mm size bolt, nuts and washers in all complete work |
| 457 | Centering and shuttering including strutting, propping etc and removal of form work for lintels, beams, plinth beams, griders, bressumers and cantilevers |
| 458 | Foundation, footings, bases of coloumn etc for mass concrete in all complete work |
| 459 | Columns, pillars, piers, abutments, posts and structs in all complete work |
| 460 | Writing for light point/fan point/ exhuast fan point/call bell poimt with 1.5 sqmm FR PVC insulated copper conductor single core cable in surface/recessed PVC condu,t, with modular switch modular plate in all complete work |
| 461 | Wiring forcircuit/submain wiring along with earth wire with the following sizes of PVC insulated. Copper conductor single core cable in surface/recessed PVC conduit as required 2x1.5 sq.mm+1x1.5 sq.mm earth wire |
| 462 | Wiring forcircuit/submain wiring along with earth wire with the following sizes of PVC insulated. Copper conductor single core cable in surface/recessed PVC conduit as required 2x2.5 sq.mm+1x2.5 sq.mm earth wire |
| 463 | Wiring forcircuit/submain wiring along with earth wire with the following sizes of PVC insulated. Copper conductor single core cable in surface/recessed PVC conduit as required 2x4 sq.mm+1x4 sq.mm earth wire |
| 464 | Wiring forcircuit/submain wiring along with earth wire with the following sizes of PVC insulated. Copper conductor single core cable in surface/recessed PVC conduit as required 2x6 sq.mm+1x6 sq.mm earth wire |
| 465 | Wiring forcircuit/submain wiring along with earth wire with the following sizes of PVC insulated. Copper conductor single core cable in surface/recessed PVC conduit as required 4x10 sq.mm+2x6 sq.mm earth wire |
| 466 | supply and fixing of following sizes of PVC conduit along with accessories in surface/recess including incuding cutting the wall and making good the same in case of recessed conduit as required 20mm |
| 467 | supply and fixing of following sizes of PVC conduit along with accessories in surface/recess including incuding cutting the wall and making good the same in case of recessed conduit as required 25mm |
| 468 | supply and drawing following sizes pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telehone cable in the existing surface/ recessed steel/ PVC conduit as reuired 2 pair |
| 469 | Supply and fixing following modular switch/socket on the existing modular plate & switch box in all complete work telephone socket outlet |
| 470 | Supplying and fixing metal box of following size nomonal size on surface or recess with suitable size of phenolic laminated sheet cover in front in all complete work 75mmx75mmx60mm deep |
| 471 | supplying and fixing following size/modular GI box strong with modular bas & cover plate for modular switches in recess 1 or 2 module (75mmx75mm) |
| 472 | Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 473 | Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing pin 5/6 amps, modular socket outlet and 5/6 amps modular switch connection painting etc as reuired |
| 474 | Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps, modular socket outlet and 15/16 amps modular switch connection painting etc as reuired |
| 475 | Supplying and fixing following way, three pole and natural, sheet steel, TP MCB distribution board. 415 volts on surface/recess, complete with tinned copper busbar, neutral burbar, earth bar, din bar, ditachable gland plate in all complete work 4way(4+12)double door, horizontal type) |
| 476 | Supplying and fixing 5 amps to 32 amps rating 240 volts C series miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB in all complete work single pole |
| 477 | Supplying & fixing single pole, blanking plate in the existing MCB DB complete as reuired |
| 478 | supplying and fixing following rating four pole 415 volts, isolator in the existing MCB DC complete with connections, testing and commissioning etc as required 40 amps |
| 479 | Installation, testing and commissioning of celling fan including wiring the down rod of standard length (upto 30cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable.in all complete work |
| 480 | Earthing with GI earth plate 600mx600mmx6mm thick including accessories and providing masonary enclsure with cover plate having locking arrangement in all complete work |
| 481 | Supplying and laying 25mmx5mm GI strip at 0.50m below ground as strip earth electrode including connection and terminating with nut, bolt, spring, washer in all complete work |
| 482 | Supplying and laying 32mmx6mm G.I strip from earth electrode directly in ground as required |
| 483 | Providing and fixing of circular/hexazonal cast ironor MS sheet box for ceiling fan clamp of internal dia 140mm 70mm height top lid of 1.5mm thick MS sheet with in all complete work |
| 484 | Providing and fixing M.V danger notice plate ogf 200mmx150mm made of mild steel, atleast 2mm thick and vertious enamelled in all complete work |
| 485 | wiring forcircuit/submain wiring along with earth wire with the following sizes of PVC insulated copper conductor single core cable in surface/recessed PVC conduct as required 2x2.5sq.mm+1x2.5sq/mm earth wire |
| 486 | Supply and fixing of following sizes of PVC conduct alng with accessories in surface/recess including cutting the wall and making in all complete work |
| 487 | Supplying and wiring of sub main with FR PVC insulated 1100 volts grade single core copper conductor cable in heavy gauge PVC condit partly in all complete work 4x25 sqmm with 2x16 sqmm earth wire in 50mm dia |
| 488 | S/F of single light wall bracket (Cat-AAA) on matching M.D.F.E.G board base etc in all complete work |
| 489 | Supply and fixing of LED tube light with battensuitable for up to 1x22 watt LED tube light fitting including tube on surface in all complete work |
| 490 | Supply and ceiling fan with fan mortor of AC permanent insulator, capacitor rating conforming BEE 5 star rating and in all complete work |
| 491 | Supply and fixing of crimping, solder, less copper ton electroplated lugs of dowel/is mail make suitable for 1.5sqmm to 6sqmm cable in all complete work |
| 492 | S/F of sheet steel enclosure for DP/TP/FP MCB with neutral link and earth terminal |
| 493 | Supply and fixing of electronic Fan regulator modular 120-280v on the existing switch board in all complete work |
| 494 | Supply of AC 230/250 volts, 50 Hz 55w 1400rpm exhaust fans in all complete work |
| 495 | Supply and fixing of LED street light fitting with mandatory driver set in all complete work |
| 496 | Supply and fixing high mast light |
| 497 | Earthwork in excavation in ordinary soil with lift 1.5m & lead upto 30m etc including all work complete |
| 498 | P.C.C 1:4:8 with in cement and fine sand and 40 mm gauge brick ballast in all work complete |
| 499 | M-150 class brick work in 1:6 cement and fine sand mortar in all complete |
| 500 | 12mm thick plaster 1:4 cement and Fine sand mortar in all complete |
| 501 | C.C 1:2:4 cement core. sand and cement concrete flooring in all complete |
| 502 | Earth work in excavation by mechanicalmeans (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer- in charge. |
| 503 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal sizederived from natural sources) |
| 504 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone- III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). slab |
| 505 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) FOUNDATION |
| 506 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement :1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) COLUMN |
| 507 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation7.5 in foundation and plinth in:Cementmortar 1:6 (1 cement : 6 coarse sand) |
| 508 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarsesand) |
| 509 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete Thermo-Mechanically Treatedbars of grade Fe-500D or more |
| 510 | 12 mm cement plaster of mix 1:6 (1cement: 6 coarse sand) |
| 511 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10sqm) |
| 512 | structiral steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 513 | Finishing with epoxy paint two or more coats at all locations prepared in all complete work |
| 514 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge.2.6.1 All kinds of soil |
| 515 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 516 | Brick work with common burnt clayF.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 517 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate20 mm nominal size derived from |
| 518 | Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. 16.46.1 Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. |
| 519 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. 2.6.1 All kinds ofsoil |
| 520 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 521 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 522 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating anddressing complete. |
| 523 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints,surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313 ( Part II 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or chordancewill be used. The rate of application of chemical emulsion shallbe as follows : (1 Treatment for masonary & foundation 5 liters pe r/ 100 Sqm.(2) Back fill in immediate contact with foundation 7.5 liters / 100 Sqm. (3) Treatment of top surface of plinth filling 5 liters / 100 Sqm. (4)Treatment junction of wall and the floor 7.5 liters / 100 Sqm. (5)Treatment of soil along external perimeter of building 7.5liters / 10 |
| 524 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).bands |
| 525 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).beams |
| 526 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). slab |
| 527 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 528 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in positionand binding all complete |
| 529 | Brick work with common burnt clay (non modular) bricks of class designation 150 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarsesand) |
| 530 | Brick work with common burnt clay (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarsesand) |
| 531 | Brick work with common burnt clay (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarsesand) |
| 532 | Providing and fixing ISI marked flush door shutters conforming to IS 2202 Part I decorative type, core of block board in all complete work |
| 533 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer all complete. |
| 534 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer all complete. |
| 535 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer all complete. |
| 536 | Fixing of steel or wooden chaukhats in position. (a) Door chaukhats |
| 537 | Fixing of steel or wooden chaukhats in position. (b) Wndow chaukhats |
| 538 | 15 mm thick plinth plaster [1 cement : 4 coarse sand] |
| 539 | 12 mm cement plaster of mix 1:6 (1 cement: 6coarse sand) |
| 540 | 15 mm cement plaster of mix 1:6 (1 cement: 6coarse sand) |
| 541 | Making grooves 10 to 12mm wide x 8 mm deep in plaster of the walls or in ceiling vertically orhorizontally as required. |
| 542 | Making drip course deep in plaster of the walls or inceiling vertically or horizontally as required. |
| 543 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominalsize stone aggregate |
| 544 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floatingcoat of neat cement 18 mm thick |
| 545 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 546 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 547 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 548 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat withcement primer |
| 549 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes |
| 550 | Providing oxidised Sliding Bolts 16 mm dia with nuts and 250 mm long. |
| 551 | Providing oxidised tower bolt with 10mm dia 250mm long ground floor |
| 552 | Providing oxidised door handles wirh screwes 125mm long ground floor |
| 553 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conformingto IS. 2645 and approved by Engineer-in-charge over the RCCslab including adjoining walls upto 300 mm height includingcleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats25 mm to 115 mm size with 50% of cement mortar 1:5 (1cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge over 20 mm thick layer of cement mortar of mix 1:5(1 cement :5 coarse sand ) admixed with water proofingcompound conforming to IS : 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoiningwalls upto 300 mm height including rounding ofjunctions of |
| 554 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors 40 mm wide and 4 mm thick |
| 555 | Suspended floors, roofs, landings, balconies and accessplatform |
| 556 | Lintels, beams, plinth beams, girders, bressumersand cantilevers |
| 557 | Foundations, footings, bases of columns, etc. formass concrete |
| 558 | Wiring for light point/fan point/exhaust fan point/call bell pointwith 1.5 sqmm FR PVC insulatedcopper conductor single core cable in surface / recessed PVC conduit,with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc.as required. |
| 559 | Wiring forcircuit / submain wiring alongwith earth wire with the following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required. 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earthwire |
| 560 | Wiring forcircuit / submain wiring alongwith earth wire with the following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required. 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. Earthwire |
| 561 | Wiring forcircuit / submain wiring alongwith earth wire with the following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required. 2 x 4 sq.mm. + 1 x 4 sq.mm. Earthwire |
| 562 | supply and fixing of following sizes of PVC conduit along with accessories in surface/recess including incuding cutting the wall and making good the same in case of recessed conduit as required 20mm |
| 563 | supply and drawing following sizes pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telehone cable in the existing surface/ recessed steel/ PVC conduit as reuired 2 pair |
| 564 | Supply and fixing following modular switch/socket on the existing modular plate & switch box in all complete work telephone socket outlet |
| 565 | Supplying and fixing metal box of following size nomonal size on surface or recess with suitable size of phenolic laminated sheet cover in front in all complete work 75mmx75mmx60mm deep |
| 566 | supplying and fixing following size/modular GI box strong with modular bas & cover plate for modular switches in recess 1 or 2 module (75mmx75mm) |
| 567 | Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 568 | Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing pin 5/6 amps, modular socket outlet and 5/6 amps modular switch connection painting etc as reuired |
| 569 | Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps, modular socket outlet and 15/16 amps modular switch connection painting etc as reuired |
| 570 | Supplying and fixing following way, three pole and natural, sheet steel, TP MCB distribution board. 415 volts on surface/recess, complete with tinned copper busbar, neutral burbar, earth bar, din bar, ditachable gland plate in all complete work 4way(4+12)double door, horizontal type) |
| 571 | Supplying and fixing 5 amps to 32 amps rating 240 volts C series miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB in all complete work single pole |
| 572 | Supplying & fixing single pole, blanking plate in the existing MCB DB complete as reuired |
| 573 | supplying and fixing following rating four pole 415 volts, isolator in the existing MCB DC complete with connections, testing and commissioning etc as required 40 amps |
| 574 | Installation, testing and commissioning of celling fan including wiring the down rod of standard length (upto 30cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable.in all complete work |
| 575 | Installation of exhaust fan upyo 450mm sweep in the existing operning in all complete work |
| 576 | Extra for fixing the louvers/shutters complete with frame for exhaust fans in all complete work |
| 577 | Earthing with GI earth plate 600mx600mmx6mm thick including accessories and providing masonary enclsure with cover plate having locking arrangement in all complete work |
| 578 | Supplying and laying 25mmx5mm GI strip at 0.50m below ground as strip earth electrode including connection and terminating with nut, bolt, spring, washer in all complete work |
| 579 | Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing as required |
| 580 | Providing and fixing of circular/hexazonal cast ironor MS sheet box for ceiling fan clamp of internal dia 140mm 70mm height top lid of 1.5mm thick MS sheet with in all complete work |
| 581 | supply and fixing of 32mm dia 2 meter long GI pipe medium class bracket for mounting of fluorescent/HPMV/HPSV street lightfilling in a ll complete work |
| 582 | wiring forcircuit/submain wiring along with earth wire with the following sizes of PVC insulated copper conductor single core cable in surface/recessed PVC conduct as required 2x2.5sq.mm+1x2.5sq/mm earth wire |
| 583 | Supply and fixing of following sizes of PVC conduct alng with accessories in surface/recess including cutting the wall and making in all complete work 50mm |
| 584 | Supplying and wiring of sub main with FR PVC insulated 1100 volts grade single core copper conductor cable in heavy gauge PVC condit partly in all complete work 4x25 sqmm with 2x16 sqmm earth wire in 50mm dia |
| 585 | S/F of single light wall bracket (Cat-AAA) on matching M.D.F.E.G board base etc in all complete work |
| 586 | Supply and ceiling fan with fan mortor of AC permanent insulator, capacitor rating conforming BEE 5 star rating and in all complete work |
| 587 | Supply and fixing of electronic Fan regulator modular 120-280v on the existing switch board in all complete work |
| 588 | Earth work in excavation by mechanicalmeans (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer- in charge. |
| 589 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal sizederived from natural sources) |
| 590 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) FOUNDATION |
| 591 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement :1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) COLUMN |
| 592 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete Thermo-Mechanically Treatedbars of grade Fe-500D or more |
| 593 | 12 mm cement plaster of mix 1:6 (1cement: 6 coarse sand) |
| 594 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10sqm) |
| 595 | structiral steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 596 | Finishing with epoxy paint two or more coats at all locations prepared in all complete work |
| 597 | Foundations, footing, bases of coloumns etc I all complete work |
| 598 | Coloumns, pillars, perls, abutments, posts and struts |
| 599 | Automatic gate security system |
| 600 | Earth work in excavation by mechanical means(Hydraulic excavator)/ manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as10 sqm on plan) including getting out and disposal ofexcavated earth lead upto 50 m and lift upto 1.5 m,as directed by Engineer-in charge. 2.6.1 All kinds of |
| 601 | Excavating, supplying and filling of local earth(including royalty) by mechanical transport upto alead of 5km also including ramming and watering ofthe earth in layers not exceeding 20 cm in trenches,plinth, sides of foundation etc. complete. |
| 602 | Providing and laying in position cement concrete ofspecified grade excluding the cost of centering andshuttering - All work up to plinth level :1:4:8 (1Cement : 4 coarse sand (zone-III) derived fromnaturalsources : 8 graded stone aggregate 20 mm nominal |
| 603 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete |
| 604 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating achemical barrier under and alround the column pitswall trenches basement excavation top surface ifplinth filling junction of wall and floor, along the theexternal perimeter of binding expansion joints,surrounding of pipes and conduits etc, complete.(plinth area of the building at ground floor only shallbe measured as per I.S.6313 (PartII 1981) Alderineemulsifiable concentrate or any other approvedmaterial such as Heptrachlor or Chlordane will beused. The rate of application of chemical emulsionshall be as follows : (1) Treatment for masonary &foundation 5 liters per sqm. (2) Back fill in immediatecontact with foundation 7.5 liters/sqm (3) Treatmentof top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters/sqm (5) Treatment of soil along external perimeter ofbuilding 7.5 liters/sqm (6) Treatment of soil underapron along external perimter 5 liters/sqm. two days |
| 605 | Providing and laying in position ready mixed or sitebatched design mix cement concrete for reinforcedcement concrete work; using coarse aggregate andfine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slagcement, admixtures in recommended proportions asper 1S: 9103 to accelerate / retard setting ofconcrete, to improve durability and workabilitywithout impairing strength; including pumping ofconcrete to site of laying, curing, carriage for allleads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of theengineer-in-charge, for the following grades o |
| 606 | Providing and laying in position ready mixed or sitebatched design mix cement concrete for reinforcedcement concrete work; using coarse aggregate andfine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slagcement, admixtures in recommended proportions asper 1S: 9103 to accelerate / retard setting ofconcrete, to improve durability and workabilitywithout impairing strength; including pumping ofconcrete to site of laying, curing, carriage for allleads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of theengineer-in-charge, for the following grades of |
| 607 | Providing and laying in position ready mixed or sitebatched design mix cement concrete for reinforcedcement concrete work; using coarse aggregate andfine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slagcement, admixtures in recommended proportions asper 1S: 9103 to accelerate / retard setting ofconcrete, to improve durability and workabilitywithout impairing strength; including pumping ofconcrete to site of laying, curing, carriage for allleads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of theengineer-in-charge, for the following grades o |
| 608 | Providing and laying in position ready mixed or sitebatched design mix cement concrete for reinforcedcement concrete work; using coarse aggregate andfine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slagcement, admixtures in recommended proportions asper 1S: 9103 to accelerate / retard setting ofconcrete, to improve durability and workabilitywithout impairing strength; including pumping ofconcrete to site of laying, curing, carriage for allleads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of theengineer-in-charge, for the following grades o |
| 609 | Providing and laying in position ready mixed or sitebatched design mix cement concrete for reinforcedcement concrete work; using coarse aggregate andfine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slagcement, admixtures in recommended proportions asper 1S: 9103 to accelerate / retard setting ofconcrete, to improve durability and workabilitywithout impairing strength; including pumping ofconcrete to site of laying, curing, carriage for allleads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of theengineer-in-charge, for the following grades of |
| 610 | Providing and laying in position ready mixed or sitebatched design mix cement concrete for reinforcedcement concrete work; using coarse aggregate andfine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slagcement, admixtures in recommended proportions asper 1S: 9103 to accelerate / retard setting ofconcrete, to improve durability and workabilitywithout impairing strength; including pumping ofconcrete to site of laying, curing, carriage for allleads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of theengineer-in-charge, for the following grades ofconcrete.: M-25 |
| 611 | Steel reinforcement for R.C.C. work includingstraightening, cutting, bending, placing in positionand binding all complete |
| 612 | Brick work with common burnt clay (non modular)bricks of class designation 150 in foundation andplinth in:Cement mortar 1:6 (1 cement : 6 coarse |
| 613 | Providing and laying damp-proof course 40mm thickwith cementconcrete 1:2:4 (1 cement : 2 coarse sand (zone-III)derived from naturalsources : 4 graded stone aggregate 12.5mmnominal size derived f |
| 614 | Providing & applying a coat of residual petroleumbitumen of grade ofVG-10 of approved quality using 1.7kg per squaremetre on damp proofcourse after cleaning the surface with brushes andfinally with apiece of cloth lightly soaked in kerosene oil. |
| 615 | Brick work with common burnt clay (non modular)bricks of class designation 150 in superstructureabove plinth level up to floor V level in all shapes andsizes in Cement mortar 1:6 (1 cement : 6 coarse |
| 616 | Brick work with common burnt clay (non modular)bricks of class designation 150 in superstructureabove plinth level up to floor V level in all shapes andsizes in Cement mortar 1:4 (1 cement : 4 coarse |
| 617 | Providing and fixing 35 mm thick factory madelaminated veneer lumber door shutter conforming toIS : 14616 and TADS 15:2001 (Part B), fixing withbutt hinges of required size with necessary screws,all complete as per directions of Engineer- in-chargeand panelling with panels of : 12 mm thick one sidePre-laminated particle board (decorative laminationon one side and other sides balancing lamination)grade -1, medium density flat pressed, three layerparticle board FPT - I or graded wood particle boardFPT-1 conforming to IS : 3087 bonded with BWPtype synthetic resin adhesive as per IS : 848 and prelaminated conforming to IS : 12823, Grade -1, Type |
| 618 | Providing and fixing ISI marked flush door shuttersconforming to IS : 2202 (Part I) decorative type, coreof block board construction with frame of 1st classhard wood and well matched teak 3 ply veneeringwith vertical grains or cross bands and face veneerson both faces of shutters.35 mm thick including ISImarked Stainless Steel butt hinges with necessary |
| 619 | Providing wood work in frames of doors, windows,clerestory windows and other frames, wroughtframed and fixed in position with hold fast lugs orwith dash fasteners of required dia & length ( holdfast lugs or dash fastener shall be paid fo |
| 620 | Providing and fixing factory made uPVC glazed/wiremesh windows/ doors comprising of lead free uPVCmulti-chambered frame, sash and mullion/coupler(where ever required) extruded profiles havingminimum wall thickness of 1.70 mm for Series R1and R2 profiles and 2.10 mm for Series R3 and R4profiles conforming to EN: 12608 in any shape,colour and design duly reinforced with galvanizedmild steel section made of required shape & size asper CPWD Specification, uPVC extruded glazingbeads, interlocks and Inline sash adaptor (whereever required) of appropriate dimension, EPDMgasket, hardware, SS 304 grade fasteners ofminimum 8 mm dia with countersunk head,comprising of matching polyamide PA6 grade sleevefor fixing frame to finished wall as per IS 1367 : Part1 to 14, plastic packers, plastic caps and necessarystainless steel screws etc. Profile of frame, sash &mullion (if required) shall be mitred cut and fusionwelded/mechanically jointed duly sealed at allcomers, including drilling of holes for fixing hardwareand drainage of water etc. After fixing frame the gapbetween frame and adjacent finished wall shall befilled with weather proof silicon sealant over backerrod of approved size and quality, all complete as perapproved drawing conforming to CPWD specification& direction of Engineer-in-Charge. Section of steelreinforcement and cross sections of uPVC profiles t |
| 621 | Providing and fixing M.S. grills of required pattern inframes of windows etc. with M.S. flats, square orround bars etc. including priming coat with approvedsteel primer all complete. |
| 622 | G.F,F.F.& S.F. |
| 623 | Fixing of steel or wooden chaukhats in position. |
| 624 | (a) Door chaukhats |
| 625 | (b) Window chaukhats |
| 626 | (c) Ventilator chaukhats |
| 627 | 15 mm cement plaster on rough side of single or halfbrick wall ofmix 1:4 (1 cement: 4 coarse sand) |
| 628 | 12 mm cement plaster of mix 1:6 (1 cement: 6coarse sand) |
| 629 | 15 mm cement plaster of mix 1:6 (1 cement: 6coarse sand) |
| 630 | Making grooves in sun shade or facia as perdirection of Engineer incharge including supply of allmaterials,labour T & P etc for proper completion ofthe work. Excluding GST |
| 631 | Making drip course in sun shade or facia as perdirection of Engineer incharge including supply of allmaterials,labour T & P etc for proper completion ofthe work. Excluding GST |
| 632 | Providing and laying vitrified floor tiles in differentsizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in allcolours and shades, laid on 20mm thick cementmortar 1:4 (1 cement : 4 coarse sand), jointing withgrey cement slurry @ 3.3 kg/ sqm including groutingthe joints with white cement and matching pigmentsetc., complete Size of Tile 600x600 mm |
| 633 | Providing and laying Vitrified tiles in different sizes(thickness to be specified by manufacturer), withwater absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade,in skirting, riser of steps, over 12 mm thick bed ofcement mortar 1:3 (1 cement: 3 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joint with white cement &matching pigments etc. complete |
| 634 | Providing and laying vitrified floor tiles in differentsizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in allcolours and shades, laid on 20mm thick cementmortar 1:4 (1 cement : 4 coarse sand), jointing withgrey cement slurry @ 3.3 kg/ sqm including groutingthe joints with white cement and matching pigmentsetc., complete (Anti Skid Vitrified flooring) (600x600 |
| 635 | Providing and laying Ceramic glazed floor tiles of size300x300 mm (thickness to be specified by themanufacturer) of 1st quality conforming to IS : 15622of approved make in colours such as White, Ivory,Grey, Fume Red Brown, laid on 20 mm thick cementmortar 1:4 (1 Cement : 4 Coarse sand), Jointing withgrey cement slurry @ 3.3 kg/sqm including pointingthe joints with white cement and matching pigment |
| 636 | Providing and fixing Ist quality ceramic glazed walltiles conforming to IS: 15622 (thickness to bespecified by the manufacturer), of approved make,in all colours, shades except burgundy, bottle green,black of any size as approved by Engineer-inCharge, in skirting, risers of steps and dados, over12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cementmixed with pigment of matching shade |
| 637 | Providing and laying Polished Granite stone flooringin required design and patterns, in linear as well ascurvilinear portions of the building all complete as perthe architectural drawings with 18 mm thick stoneslab over 20 mm (average) thick base of cementmortar 1:4 (1 cement : 4 coarse sand) laid andjointed with cement slurry and pointing with whitecement slurry admixed with pigment of matchingshade including rubbing, curing and polishing etc. allcomplete as specified and as directed by theEngineer-in-Charge.Polished Granite stone slab |
| 638 | Cement concrete flooring 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate) finished with afloating coat of neat cement, including cement slurry,but excluding the cost of nosing of steps etc.complete.40 mm thick with 20 mm nominal siz |
| 639 | Applying priming coat: With ready mixed red oxidezinc chromate primer of approved brand andmanufacture on steel galvanised iron/ steel worksFinishing with Epoxy paint (two or more coats) at alllocations prepared and applied as per manufacturer’sspecifications including appropriate priming coat,preparation of surface, etc. complete. 13.52.1 On |
| 640 | Finishing with Deluxe Multi surface paint system forinteriors and exteriors using Primer as permanufacturers specifications Painting wood workwith Deluxe Multi Surface Paint of required shade.Two or more coat applied @ 0.90 ltr/10 sqm over anunder coat of primer applied @0.75 ltr/10 sqm ofapproved brand and manufacture |
| 641 | Polishing in high gloss/matt finish melamine clearpolish on wood work in required color/wooden shadetexture with following process in the sequence asdetailed below:1. The surface to be polished is rubbed with sandpaper 80/ 120 no. and then with sand paper of160/180 nos.2. Applying two coats of sealer with spray gun andallowingsufficient drying time for 1st coat and 2nd coat isallowedto dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emerycloth offiner grading with ample water to remove excesssealerlayer and make the surface further smooth after thiswetrubbing, then surface is applied with special grademelamine fillers to fill all the small and bigholes/groovesetc. Filler coat to be allowed to dry for 4 to 6 hrs onwhichagain a light wet rubbing is done this surface isfurtherallowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied withspray |
| 642 | Finishing walls with Premium Acrylic Smooth exteriorpaint with Silicone additives of required shade : Newwork (Two or more coats applied @ 1.43 ltr/ 10 sqmover and including priming coat of exterior primerapplied @ 2.20 kg/ 10 sqm). |
| 643 | Providing and applying plaster of paris putty of 2 mmthickness over plastered surface to prepare thesurface even and smooth complete. |
| 644 | Wall painting with acrylic emulsion paint, having VOC(Volatile Organic Compound ) content less than 50grams/ litre, of approved brand and manufacture,including applying additional coats whereverrequired, to achieve even shade and colour. Two |
| 645 | Providing & fixing glass panes with putty and glazingclips in steel doors, windows, clerestory windows, allcomplete with :4.0 mm thick glass panes |
| 646 | Providing & fixing Stainless steel Sliding bolts withnuts & bolts (Bolt 16mm dia 250mm long) |
| 647 | Providing & fixing Stainless steel Tower bolts withnuts & bolts (Bolt 10mm dia 200mm long) |
| 648 | Providing & fixing Stainless steel handles withscrews etc. complete (a) 150 mm |
| 649 | Providing and laying integral cement based waterproofing treatment including preparation of surfaceas required for treatment of roofs, balconies, terracesetc consisting of following operations: a) Applying aslurry coat of neat cement using 2.75 kg/sqm. ofcement admixed with water proofing compoundconforming to IS. 2645 and approved by Engineer-incharge over the RCC slab including adjoining wallsupto 300mm height including cleaning the surfacebefore treatment. b) Laying brick bats with mortarusing broken bricks/brick bats 25 mm to 115mm sizewith 50% of cement mortar 1:5 (1 cement : 5 coarsesand) admixed with water proofing compoundconforming to IS : 2645 and approved by Engineer-incharge over 20 mm thick layer of cement mortar ofmix 1:5 (1 cement :5 coarse sand ) admixed withwater proofing compound conforming to IS : 2645and approved by Engineer-in-charge to requiredslope and treating similarly the adjoining walls upto300 mm height including rounding of junctions ofwalls and slabs c) After two days of proper curingapplying a second coat of cement slurry using2.75kg/ sqm of cement admixed with water proofingcompound conforming to IS : 2645 and approved byEngineer-in-charge. d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1cement :4 coarse sand) admixed with water proofingcompound conforming to IS : 2645 and approved by |
| 650 | Construction of drain of size of size 150 x 150 mmalong with apron including excavation,base concrete1:4:8 in thickness of 7.5cm of and brick work infoundation 1:4( 1 cement : 4 coarse sand) andbrickwork in half brick thick in foundation 25mm thickcement concrete (1:2:4 mix) flooring base and 20mmthick plaster (1:2) finished with neat cement. |
| 651 | Providing and fixing stainless steel ( Grade 304)railing made of Hollow tubes, channels, plates etc.,including welding, grinding, buffing, polishing andmaking curvature (wherever required) and fitting thesame with necessary stainless steel nuts and boltscomplete, i/c fixing the railing with necessaryaccessories & stainless steel dash fasteners ,stainless steel bolts etc., of required size, on the topof the floor or the side of waist slab with suitablearrangement as per approval of Engineer-incharge,(for payment purpose only weight of stainless steelmembers shall be considered excluding fixing |
| 652 | Providing and fixing fly proof galvanized M.S. wiregauge to windows and lerestory windows using wiregauge with average width of aperture 1.4 mm in bothdirections with wire of dia 0.63 mm all complete.With2nd class teak wood beading 62X19 mm |
| 653 | Providing and fixing glass strips in joints of terrazo/cement concrete floors 40 mm wide and 4 mm thick |
| 654 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 655 | Suspended floors, roofs, landings, balconies andaccess |
| 656 | Lintels, beams, plinth beams, girders, bressumersand cantilevers |
| 657 | Foundations, footings, bases of columns, etc. formass concrete |
| 658 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 659 | Wiring for light point/fan point/exhaust fanpoint/call bell pointwith 1.5 sqmm FR PVCinsulatedcopper conductor single core cable insurface / recessed PVC conduit,with modularswitch, modular plate, suitable G.I. box andearthing the point with 1.5 sqmm FR PVCinsulated copper conductor single core cable |
| 660 | Wiring for twin control light point with 1.5sqmm FR PVC insulated copper conductorsingle core cable in surface/ recessed PVCconduit, 2 way modular switch, modular plate,suitable G.I. box and earthing the point with 1.5sqmm FR PVC insulated copper conductorsingle core cable etc. as required. |
| 661 | Wiring forcircuit / submain wiring alongwithearth wire with the following sizes of PVCinsulated,copper conductor single core cablein surface/ recessed PVC conduit as required.2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. Earth wire |
| 662 | 2 x 4 sq.mm. + 1 x 4 sq.mm. Earth wire |
| 663 | 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 664 | 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire |
| 665 | Supply and fixing of following sizes of PVCconduit along with accessories insurface/recess including cutting the wall andmaking good the same in case of recessed |
| 666 | Supplying and drawing following pair 0.5 mmdia FRLS PVC insulated annealed copperconductor, unarmored telephone cable in theexisting surface/ recessed steel/ PVC conduitas required. |
| 667 | Supply and drawing of co-axial TV cable RG-6grade, 0.7 mm. Solid copper conductor PEinsulated, shielded with fine tinned copper braidand protected with PVC sheath in the existingsurface / recessed conduit as required |
| 668 | Supplying and fixing following modular switch/socket on the existing modular plate & switchbox including connections but excludingmodular plate etc. as requiredTelephone socket outlet |
| 669 | TV Antenna socket outlet |
| 670 | Supplying and fixing metal box of following size(nominal size) on surface or recess with suitablesize of phenolic laminated sheet cover in fromtincluding paintingetc. as required.75 mm x 75 mm x 60 mm deep |
| 671 | Supplying and fixing following size / modules, GIbox alongwith modular base & cover platefor modular switches in recess etc. as required.1 or 2 Module (75 mmX75 mm) |
| 672 | Supply and fixing modular blanking plate onthe existing modular plate & switch boxexcluding modular plate as required. |
| 673 | Supply and fixing of suitable size GI box withmodular plate and cover in front on surface or inrecess, including providing and fixing3 pin 5/6amps. modular socket outlet and 5/6 amps.modular switch, connection, painting etc. asrequired. |
| 674 | Supply and fixing of suitable size GI box withmodular plate and cover in front on surface or inrecess, including providing and fixing 6 pin15/16 & 5/6 amps. modular socket outlet and15/16 amps. modular switch, connection,painting etc. as required. |
| 675 | Supplying and fixing following way, three poleand neutral, sheet steel, TP MCB distributionboard, 415 volts,on surface /recess, completewith tinned copper busbar, neutral busbar,earth bar, din bar, detachable gland plate,interconnections, phosphatized and powderpainted including earthing etc. as required (Butwithout MCB / RCCB / Isolators). 4 way (4 + 12), Double door, horizontal type |
| 676 | Supplying and fixing 5 amps. to 32 amps.rating, 240 volts `C' series, miniature circuitbreaker (MCB)suitable for inductive load offollowing poles in the existing MCB DBcomplete with connections, testing andcommissioning etc. as required.single pole |
| 677 | Supplying & fixing single pole, blanking plate inthe existing MCB DB complete etc. as |
| 678 | Supplying and fixing20 amps, 240 volts,SPN,industrial type socket outlet, with 2poles and earth metal enclosed plug top alongwith 20 amps. \\"C\\" series, SP MCB in sheetsteel enclosure, on surface or in recess, withchained metal cover for the socket outlet, andcomplete with connections, testing and |
| 679 | Supplying and fixing following rating,four pole,415 volts, isolator in the existing MCB DBcomplete with connections, testing andcommissioning etc. as required.40 amps |
| 680 | Installation, testing and commissioning ofceiling fan including wiring the down rod ofstandard length (upto 30 cm.) with 1.5 sq. mm.FR PVC insulated, copper conductor, singlecore cable, including providing and fixingphenolic laminated sheet cover on the fan box |
| 681 | nstallation of exhaust fanupto 450 mm sweepin the existing opening, including making thehole to suit the size of the above fan, makinggood the damage, connections, testing,commissioning etc. as required. |
| 682 | Extra for fixing the louvers / shutterscomplete with frame fro exhaust fans of al |
| 683 | Supplying and fixing of call bell/buzzer suitablefor DC/AC single phase, 230 volts, complete asrequired. |
| 684 | Earthing with GI earth plate 600mm x 600 mmx 6mm thick including accessories andproviding masonary enclosure with cover platehaving locking arrangement and watering pipe2.7 m long etc, with charcoal/coke and salt asrequired. |
| 685 | Earthing withGI earth pipe4.5 mtr long, 40 mmdia including accessories and providingmasonary enclosure with cover plate havinglocking arrangement and watering pipe etc, withcoke and salt as required |
| 686 | Supplying and laying25 mm x 5 mm. G.I. stripat 0.50 M. below ground as strip earthelectrode, including connection and terminatingwith nut, bolt, spring, washer etc as required(jointing shall be done by overlapping and with 2sets of brass nut bolt and spring washer spaced |
| 687 | Providing and fixing 6 SWG dia G.I. wire onsurface or in recess for loop earthing as |
| 688 | Providing and laying earth connections fromearth electrode with 6 SWG dia G.I. wire in 15mm dia G.I. pipe from earth electrode as |
| 689 | Providing and fixing of circular / hexazonalcast ironor MS sheet box for ceiling fanclamp, of internal dia 140 mm, 73 mm height,top lid of 1.5 mm thick MS sheetwith it topsurface hacked for proer bonding, top lid shallbe screwed into the cost iron/MS sheet box bymeans of 3.3 mm dia round headed screws,one lock at the corners. Clamp shal be made of12 mm dia MS bar bent to shape as per |
| 690 | Providing and fixing M.V. danger notice plateof 200mmx150mm made of mild steel, atleast2mm thick and vitreous enamelled white on bothsides and with inscription single red colour onfront side as required. |
| 691 | Supply and installing of following size ofperforated Hot Dipped Galvanised Iron cabletrays (Galvanisation thickness not less 50miccrons) with preforation not more than 17.5%,in convenient sections, jointed with connectors,suspended from the ceiling with G.I. suspendersincluding G.I. bolts & nuts etc as required300mm width x 50mm depth x 1.6 mm |
| 692 | Providing, laying and fixing following dia RCCpipe NP2 class (light duty) in ground completewith RCC collars, jointing with cement mortar1:2 (1 cement : 2 fine sand) including trenching(75 cm deep) and refilling etc as required.100 mm dia |
| 693 | Add for Invertor Wiring in wiring Point forlight/Fan/Plug with 1.5 mm Cu Wire |
| 694 | S/F of single light wall bracket (Cat-AAA) onmatching M.D.F.E.G. board base etc. completein all respects.Category AA |
| 695 | S/F of recess/surface/pendent mounted 6 to 8watt LED down lighter having powder coateddie cast aluminium housing with heat sink,diffuser / reflector and driver set complete in all |
| 696 | S/F of LED Tube Light with batten suitable forup to 1x22 watt LED tube light fitting includingtube on surface complete in all respect. Category AAA |
| 697 | Supply of ceiling fan with fan motor of ACpermanent insulation, capacitor ratingconforming BEE 5 star rating and IS : 374/79and also comply with IS:1709/1984 with latestamendment the rated voltage 220/240 volts, 50HZ single phase AC, the fan assembled shouldconsists of down rod, blades, shackle canopiesetc and with double ball bearing system.BEE 5 star rating - 1200 mm sweep |
| 698 | Supply & fixing of Crimping, solder, less, copperton electroplated lugs of Dowel/ismail makesuitable for 1.5 sqmm to 6 sqmm cables,including tapping with insulating tape, etc. |
| 699 | Supply & fixing of electronic Fan regulator(Modular), 120-280 V, ISI marked, on theexisting switch board including makingconnections, required material, labour T&P etc.for proper completion of work to the satisfactionof Engineer of work. |
| 700 | Supply and laying of ISI marked aluminumconductor PVC / XLPE insulated armoured,served, sheathed cable 1100 volts grade at750 mm below ground level over a cushionof 75 mm thick sand around & protected withbrick on sides & top on surface the cable runshall be fixed on M.S. clamps etc. of suitablesize complete in all respect. The armouring ofthe cable shall be properly connected with the |
| 701 | Supply and fixing brass nickel platedcompression glands for PVC insulatedarmoured, served, sheathed cable includingrubber ring etc. complete in all respect. Thearmouring of the cable shall be properly50 sqmm 3 1/2 core |
| 702 | Supply & fixing of plam or pin type copper tinplated cable socket (lug) to the cable leads,insulating with tape and making connectionsetc. complete in all respects as per direction o |
| 703 | Construction of recess distribution board of allsizes including cutting of brick work providinglintel of suitable size & thickness plastering etc.with supply of all materials, labours, T & P etc.required for proper completion of work600x480x200 mm. size |
| 704 | Supply and fixing of factory fabricated M.S. boxin existing sunk with Godrej type almirah coverwith handle etc. fabricated from 18 SWG M.S.sheet duly painted with red oxide primerfollowed by two coats of synthetic enamel paintcomplete with necessary conduit entry andDP/TPN; fixing arrangement and provision forcompartment for loose wires, openable housingon the top and hold fast etc. including supply ofall material, labour and T & P etc. required for 600x480x200 mm. size |
| 705 | Supply & Erracetion of factory fabricated &wired metal clad dust and vermin proof floormounting, M.S. Channel Base with bottom andtop cable entreis Electrical control panel withTPN MCCB’s (Four Pole 36 KA with thermalmagnatic release) Switches complete andinstrument chamber etc. complete in allrespects. The instrument chamber shall beseparate and shall comprise of flush type digitalmetering system for phase to phase voltage andsingle phase voltage, current and otherparameters (KVA, P.F, KW etc) in each phasewith touch type selector switches for differentreadings, instrument fuses, current transformeretc. The panel board shall have suitablecapacity electrolytic aluminium busbars as perIS8623 or above istulated with heat shrinksleeving and mounted on non hygroscopicsupports such as CMC/BMC support withdeteachable side covers and shall be suitablefor extension on the sides. The MCCB’s shall becomplete with suitable cable end boxes,compression glands and indicating lamp onThe Job includes the grounting of the board asper directions of Engineer-in charge. All outgoings of 100 Amp and above shall have anAmmeter. The panel board shall be fabricatedwith CRCA sheet with a minimum thickness of1.6 mm/2 mm. Cubicle type switch board shallbe of cat A & B only. All bus bars shall be of aluminium, electrolyticgrade only. Maximum design density shall notexceed 1 Amps/Sqmm. All bus bars shall beinsulated with coloured heat shrinkable PVCsleeved. All bus bar supports shall be nonhygroscopic DMC/SMC supports.The panel shall be manufactured inconformance to requirements of local electricalinspector and it shall be contractorsresponsibility to get initial approval of drawingsand also final approval of complete electricalworks related to this section. The minimum clearances between bus barsshall be as follows :Phase to phase - minimum 20mmPhase to neutral-minimum 15mmCubical Panel Board ( MCCB Type) Main L.T. Panel (Meter Panel Board)Incoming : One (1) No.200Amp. MCCB-1No.Metering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeterwith control fuse & selector switch.One (1) No. (0-200A) 96 x 96 Sqmm CToperated Ammeter with selector switch, CTsOne (1) Set of Phase Indication Lamp.Bus Bar :One (1) No.200 A, TPN aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.100 Amp. MCCB- 1 No.63 Amp. MCCB- 3 No.Or outgoing as per site requirment(AS/SLD) |
| 706 | Supply and laying of 1800 mm x 900 mm x 12mm thick chequered rubber matting of tested |
| 707 | Supply and fixing 200 AMP four pole Mouldedcase type on load change over switch withenclosure(also suitable for panel mounting withextra cost of bus bar) including the cost oflabour, T & P , painting and other materialrequired for proper completion of the work asper direction and satisfaction of Engineer in |
| 708 | Supply and fixing of single phasemultifunctional electronic energy meter 10 to60 Amp. capacity fitted in integral box on wallcomplete in all respect. |
| 709 | Supply of AC 230/250 Volts, 50 Hz 55w 1400rpm exhaust fans including providing nuts,bolts, mounting frame and other accessoriesincluding connections etc. complete as required.300mm sweep. |
| 710 | Providing and fixing white vitreouschina pedestal type water closet( European type W.C. pan ) with seatand lid, 10 litre low level white P.V.C.flushing cistern, including flush pipe,with manually controlled device(handle lever) conforming to IS : 7231,with all fittings and fixtures complete,including cutting and making good thewalls and floors whereverrequired:W.C. pan with ISI marked |
| 711 | Providing and fixing wash basin withC.I. brackets, 15 mm C.P. brass pillartaps, 32 mm C.P. brass waste ofstandard pattern, including painting offittings and brackets, cutting andmaking good the walls whereverrequire a) White Vitreous China Flat backwash basin size 550x 400 mm withsingle 15 mm C.P. brass pillar tappillar |
| 712 | Providing and fixing flexible P.V.C.waste pipe for sink or wash basinFelxible pipe 1b) 40mm dia |
| 713 | Providing and fixing 600x450 mmbeveled edge mirror of superior glass(of approved quality) complete with 6mm thick hard board ground fixed towooden cleats with C.P. brass screws |
| 714 | Providing and fixing 8 mm diaC.P./S.S. Jet with flexible tube upto 1meter long with S.S. triangular platefor Eureopean type W.C. of quality andmake as approved by engineer-incharge.DSR 2023SCHEDULE OF QUANTITIES FOR PLUMBING WORKSPROJECTTYPE-GARBAGE OFFICE PLUMBING (SCHEDULED ITEMS AS PER D.S.R 2023)COST INDEXSANITARY FIXTURES & ACCESSORIES : I15mm nominal bore |
| 715 | Providing and fixing CP Brass 32 mmsize Bottal Trap of approved quality& make and as per thedirection ofEnginer-in-charge |
| 716 | Providing & fixing PTMT towl railcomplete with brackets fixed towooden cleats with cp brass screwswith concealed fitting arrangement ofapproved quality and colour. 600 mm.long towl rail length of 645 mm. width78 mm. and effective height of 88 mm,weighing not less than 190 gms. |
| 717 | Providing and fixing PTMT Liquidsoap container 109 mm wide ,125 |
| 718 | Providing and fixing of UPVC SWRring fit pipe of class B of ISI markConfirming to IS code 13592 (makeprince, supreme finolex) in internalworks of toilet and RWP etc. includingfixing with rubber rings etc. includingcost of all material, labour etc.110mm diameter |
| 719 | 90mm diameter |
| 720 | Haunching of SWR pipe 90mm or110mm with pcc 1:2:4 cementconcrete ( 1 cement:2 coarse sand:4 |
| 721 | Supply and fixing of UPVC S.W.R.pipe nahni trap size 100x75,110/90mm confirming to IS-14735 selfcleaning design fixed in PCC 1:2:4 andsupply and fixing of 125 mm dia heavyduty CP brass jali. |
| 722 | Supply and fixing of UPVC S.W.R.Cowel confirming to IS-14735.Size 75/90 mm |
| 723 | Size 110 mm |
| 724 | Making khurras 45x45 cm withaverage minimum thickness of 5 cmcement concrete 1:2:4 (1 cement : 2coarse sand : 4 graded stoneaggregate of 20 mm nominal size)over PVC sheet 1m x 1 m x 400micron, finished with 12 mm cementplaster 1:3 (1 cement : 3 coarse sand)and a coat of neatcement,punning,rounding the edgesa) 110mm |
| 725 | Providing and fixing to the inlet mouthof rain water pipe cast iron grating 15cm diameter and weighing not lessthan 440 grams. |
| 726 | Providing and fixing ChlorinatedPolyvinyl Chloride (CPVC) pipes,having thermal stability for hot & coldwater supply including all CPVC plain& brass threaded fittings includingfixing the pipe with clamps at 1.00mspacing. This includes jointing ofpipes & fittings with one step CPVCsolvent cement and testing of jointscomplete as per direction of Enginee20mm dia nominal outer dia pipes |
| 727 | 25mm dia nominal outer dia pipes |
| 728 | 32mm dia nominal outer dia pipes |
| 729 | 40mm dia nominal outer dia pipes |
| 730 | Providing and fixing ChlorinatedPolyvinyl Chloride (CPVC) pipes,having thermal stability for hot & coldwater supply including all CPVC plain& brass threaded fittings i/c fixing thepipe with clamps at 1.00m spacing.This includes jointing of pipes & fittingswith one step CPVC solvent cementand the cost of cutting chases andmaking good the same includingtestiang of joints complete as perdirection of Engineer in Charge.Concealed work including cuttin16mm dia nominal outer dia pipes |
| 731 | 20mm dia nominal outer dia pipes |
| 732 | Providing and fixing 45 cm longunplasticised PVC connection pipewith brass unions.45 cm lengthi) 15mm nominal bore |
| 733 | Providing and fixing 45 cm longunplasticised PVC connection pipewith brass unions.45 cm lengthi) 15mm nominal bore |
| 734 | Providing & fixing C.P. brass long bodybib cock of approved qualityconforming to IS standards andweighing not less than 690 gms.15mm nominal bore |
| 735 | Providing and fixing gun metal gatevalve with wheel of approvedquality(screwed end)..25mm dia nominal bor |
| 736 | Providing and fixing gun metal gatevalve with wheel of approve |
| 737 | Providing and fixing ball valve (brass)of approved quality, High or lowpressure, with plastic floats complete25 mm nominal bore |
| 738 | Providing and placing on terrace (at allfloor levels) polyethylene waterstorage tank of approved brand andmanufacture with cover and suitablelocking arrangement and makingnecessary holes for inlet, outlet and 18.48For 500 litres |
| 739 | Excavating trenches in all kind of soilof required width for pipes, cables etc.including excavation for sockets anddressing of sides, ramming of bottoms, in layers not exceeding 20cm in depthincluding consolidating each depositedlayer by ramming, watering, etc &disposig of surplus excavated soil asdirected within a lead of 50m.a) Pipes 80mm to 300mm diameter. |
| 740 | Providing and fixing UPVC S.W.RGully trap grade 'A' complete with C.I.grating brick masonry chamber andwater tight C.I.cover frame of 300 x300mm. size (inside) square mouthtraps of \\"P\\" or \\"S\\" type traps.a) 100 x 150 mm. dia |
| 741 | Constructing brick masonry manholein cement mortar 1:4 (1 cement :4coarse sand) RCC top slab with 1:2:4mix (1 cement :2 coarse sand :4graded stone aggregate 20mmnominal size), foundation concrete1:4:8 mix (1 cement :4 coarse sand :8graded stone aggregate 40mmnominal size) inside plastering 12mmthick with cement mortar 1:3 (1cement :3 coarse sand) finished withfloating coat fo neat cement andmaking channels in cement concrete1:2:4 (1 cement :2 coarse sand :4graded stone aggregate 20mm nminalsize) finished with a floating coat ofneat cement complete as per standard 19.7Inside size 900x800mm and 500mmdeep including CI cover with frame 19.7.1With FPS bricks of class designation |
| 742 | Extra for depth of man hole size |
| 743 | Providing M.S. foot rests includingfixing in manholes with20x20x10 cm cement concrete blocks1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20mm nominal size) as perstandard designWith 20x20 mm square bar |
| 744 | Providing and fixing of upvc SWRring fit pipe of class B of ISI markConfirming to IS code 13592 (makeprince, supreme finolex) in internalworks of toilet and RWP etc. includingfixing with rubber rings etc. includingcost of all material, labour etc.complete.. b) 160mm diameter |
| 745 | Haunching of SWR pipe 90mm or110mm or 160mm with pcc 1:5:10cement concrete ( 1 cement:2 coarsesand:4 stone grit) AR |
| 746 | Earth work in excavation bymechanical means (Hydraulicexcavator)/ manual means over areas(exceeding 30 cm in depth, 1.5 m inwidth as well as 10 sqm on plan)including getting out and disposal ofexcavated earth lead upto 50 m andlift upto 1.5 m, as directed byEngineer-in charge. 2.6.1 All kinds of |
| 747 | Excavating, supplying and filling oflocal earth (including royalty) bymechanical transport upto a lead of5km also including ramming andwatering of the earth in layers notexceeding 20 cm in trenches, plinth,sides of foundation etc. complete. |
| 748 | Providing and laying in positioncement concrete of specified gradeexcluding the cost of centering andshuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand(zone-III) derived from naturalsources : 8 graded stone aggregate20 mm nominal sizederived from natural sources) |
| 749 | Supplying and filling in plinth withsand under floors, including watering,ramming, consolidating and dressing |
| 750 | Providing and injecting chemicalemulsion for Preconstructionalantltermite treatment and creating achemical barrier under and alroundthe column pitswall trenchesbasement excavation top surface Ifplinth filling junction of wall and flooralong the extemal perimer of bindingexpansion jolnts,surroundings ofpipes and conduit etc. complete(Plintharea of the building at ground flooronly shall be measured as per I.S.6313 (Part II 1981) Aldrineemulsifiable concentrate or any otherapproved material such asHepthachlor or chlordance will beused. The rateof applications ofchemical emulsion sl1all be asFollows :. (1) Treatment forMaS9nary& foundatiion 5 Liters perSq.m. (2) Back fill Inimmediatecontract with foundation 7.5Litres per Sq.M. (3) Treatment,of Topsurface of plinth filling 5 LitresperSq.M. (4) Treatment of soli alongExternal Perimerter of Building7.50 |
| 751 | Reinforced cement concrete work inbeams, suspended floors, roofshaving slope up to 15° landings,balconies, shelves, chajjas, lintels,bands, plain window sills, staircasesand spiral stair cases above plinthlevel up to floor five level, excludingthe cost of centering, shuttering,finishing and reinforcement with1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from naturalsources : 3 graded stone aggregate20 mm nominal size derived from |
| 752 | Reinforced cement concrete work inbeams, suspended floors, roofshaving slope up to 15° landings,balconies, shelves, chajjas, lintels,bands, plain window sills, staircasesand spiral stair cases above plinthlevel up to floor five level, excludingthe cost of centering, shuttering,finishing and reinforcement with1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from naturalsources : 3 graded stone aggregate20 mm nominal size derived fromnatural sources). sunshade SLAB (a) Ground Floor |
| 753 | Providing and laying in position readymixed or site batched design mixcement concrete for reinforcedcement concrete work; using coarseaggregate and fine aggregate derivedfrom natural sources, PortlandPozzolana / Ordinary Portland/Portland Slag cement, admixtures inrecommended proportions as per 1S:9103 to accelerate / retard setting ofconcrete, to improve durability andworkability without impairing strength;including pumping of concrete to siteof laying, curing, carriage for all leads;but excluding the cost of centering,shuttering, finishing andreinforcement as per direction of th |
| 754 | Providing and laying in position readymixed or site batched design mixcement concrete for reinforcedcement concrete work; using coarseaggregate and fine aggregate derivedfrom natural sources, PortlandPozzolana / Ordinary Portland/Portland Slag cement, admixtures inrecommended proportions as per 1S:9103 to accelerate / retard setting ofconcrete, to improve durability andworkability without impairing strength;including pumping of concrete to siteof laying, curing, carriage for all leads;but excluding the cost of centering,shuttering, finishing andreinforcement as per direction of th |
| 755 | Steel reinforcement for R.C.C. workincluding straightening, cutting,bending, placing in position andbinding all complete DSR 5.22(a) Ground Floor |
| 756 | Brick work with common burnt clay(non modular) bricks of classdesignation 150 in foundation andplinth in:Cement mortar 1:6 (1 cemen |
| 757 | Brick work with common burnt clay(non modular) bricks of classdesignation 150 in superstructureabove plinth level up to floor V level inall shapes and sizes in Cementmortar 1:6 (1 cement : 6 coarse sand) |
| 758 | Brick work with common burnt clay(non modular) bricks of classdesignation 150 in superstructureabove plinth level up to floor V level inall shapes and sizes in Cementmortar 1:4 (1 cement : 4 coarse sand) 6.4.1Ground Floor |
| 759 | Providing and laying damp-proofcourse 40mm thick with cementconcrete 1:2:4 (1 cement : 2 coarsesand (zone-III) derived from naturalsources : 4 graded stone aggregate12.5mm nominal size derived from |
| 760 | Providing & applying a coat ofresidual petroleum bitumen of gradeof VG-10 of approved quality using1.7kg per square metre on dampproof course after cleaning thesurface with brushes and finally with apiece of cloth lightly soaked in |
| 761 | Providing and laying integral cementbased water proofing treatmentincluding preparation of surface asrequired for treatment of roofs,balconies, terraces etc consisting offollowing operations:Applying a slurrycoat of neat cement using 2.75kg/sqm ofcement admixed with water proofingcompound conformingto IS. 2645 and approved by Engineerin-charge over the RCCslab including adjoining walls upto300 mm height includingcleaning the surface before treatment.(b) Laying brick bats with mortar usingbroken bricks/brick bats25 mm to 115 mm size with 50% ofcement mortar 1:5 (1cement : 5 coarse sand) admixed withwater proofingcompound conforming to IS : 2645and approved by Engineer in-chargeover 20 mm thick layer of cementmortar of mix 1:5(1 cement :5 coarse sand ) admixedwith water proofingcompound conforming to IS : 2645 |
| 762 | Providing and fixing ISI marked flushdoor shutters conforming to IS : 2202(Part I) decorative type, core of blockboard construction with frame of 1stclass hard wood and well matchedteak 3 ply veneering with verticalgrains or cross bands and faceveneers on both faces of shutters.(a) Ground Floor |
| 763 | Structural steel work in single section,fixed with or without connecting plate,including cutting, hoisting, fixing inposition and applying a priming coatof approved steel primer all complete.a Providing & fixing of hold fast forchaukhats of doors and windows. |
| 764 | Structural steel work in single section,fixed with or without connecting plate,including cutting,hoisting, fixing in position andapplying a priming coat of approvedsteel primer all complete.Providing & fixing of door / windows |
| 765 | Z-Section steel windows |
| 766 | Providing & fixing of hold fast forchaukhats of doors and windows |
| 767 | Fixing of steel or wooden chaukhats in position.(a) Ground Floor(a) Door chaukhats |
| 768 | 12 mm cement plaster of mix 1:6 (1cement: 6 coarse sand) DSR 13.4.2(a) Ground Floor |
| 769 | 12 mm cement plaster of mix 1:6 (1cement: 6 coarse sand) DSR 13.4.2(a) Ground Floor |
| 770 | Providing and laying Ceramic glazedfloor tiles of size 300x300 mm(thickness to be specified by themanufacturer) of 1st qualityconforming to IS : 15622 of approvedmake in colours such as White, Ivory,Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), Jointingwith grey cement slurry @ 3.3 kg/sqmincluding pointing the joints with whitecement and matching pigment etc.,DSR 11.37(a) Ground Floor |
| 771 | Providing and fixing Ist qualityceramic glazed wall tiles conformingto IS: 15622 (thickness to be specifiedby the manufacturer), of approvedmake, in all colours, shades exceptburgundy, bottle green, black of anysize as approved by Engineer-inCharge, in skirting, risers of steps anddados, over 12 mm thick bed ofcement mortar 1:3 (1 cement : 3coarse sand) and jointing with greycement slurry @ 3.3kg per sqm,including pointing in white cementmixed with pi |
| 772 | Making grooves 10 to 12mm wide x 8mm deep in plaster of the walls or inceiling vertically or horizontally asrequired. |
| 773 | Making Drip course 10 to 12mm widex 8 mm deep in plaster of the walls orin ceiling vertically or horizontally asrequired. |
| 774 | Cement concrete flooring 1:2:4 (1cement : 2 coarse sand : 4 gradedstone aggregate) finished with afloating coat of neat cement, includingcement slurry, but excluding the costof nosing of steps etc. complete.11.3.1 40 mm thick with 20 mmnominal size ston |
| 775 | Construction of drain alongwith apron |
| 776 | Finishing with Epoxy paint (two ormore coats) at all locations preparedand applied as per manufacturer'sspecifications including appropriatepriming coat, preparation of surface,etc. complete. On steel work 13.52.1(a) Ground Floor |
| 777 | Finishing with Deluxe Multi surfacepaint system for interiors andexteriors using Primer as permanufacturers specifications Paintingwood work with Deluxe Multi SurfacePaint of required shade. Two or morecoat applied @ 0.90 ltr/10 sqm overan under coat of primer [email protected] ltr/10 sqm of approved brandand manufa |
| 778 | Finishing walls with Premium AcrylicSmooth exterior paint with Siliconeadditives of required shade : Newwork (Two or more coats applied @1.43 ltr/ 10 sqm over and includingpriming coat of exterior primer applied@ 2.20 kg/ 10 sqm).(DSR13.47.1)(a) Ground Floor |
| 779 | Distempering with oil bound washabledistemper of approved brand andmanufacture to give an even shade :13.41.1 New work (two or more coats)over and including water thinnablepriming coat with cement primer DSR 13.41(a) Ground Floor |
| 780 | Distempering with oil bound washabledistemper of approved brand andmanufacture to give an even shade :13.41.1 New work (two or more coats)over and including water thinnablepriming coat with cement primer DSR 13.41(a) Ground Floor |
| 781 | Providing and applying white cementbased putty of average thickness 1mm, of approved brand andmanufacturer, over the plastered wallsurface to prepare the surface evenand smooth c |
| 782 | Providing & fixing glass panes withputty and glazing clips in steel doors,windows, clerestory windows, allcomplete with :4.0 mm thick glasspanesDSR 10.30(a) Ground Floor |
| 783 | Providing & fixing Stainless steelsliding door bolts ISI marked anodised(anodic coating not less than gradeAC 10 as per IS : 1868) transparent ordyed to required colour or shade withnuts and screws etc complete. (a)250mm x 16mm .MR(a) Ground Floo |
| 784 | Providing and fixing stainless steeltowerbolts (barrel type) withnecessary screws etc. complete MR(a) Ground Floor |
| 785 | Providing and fixing stainless steelhandles with screws etc. complete (a)150 mm MR(a) Ground Floor |
| 786 | Centering and shuttering includingstrutting, propping etc. and removal ofform work for :A Lintels, beams, plinth beams, girders,bressumers and cantilevers |
| 787 | Suspended floors, roofs, landings,balconies and accessplatform |
| 788 | Wiring for light point/fanpoint/exhaust fan point/call bellpointwith 1.5 sqmm FR PVCinsulatedcopper conductor singlecore cable in surface / recessed PVCconduit,with modular switch, modularplate, suitable G.I. box and earthingthe point with 1.5 sqmm FR PVCinsulated |
| 789 | Wiring for twin control light pointwith 1.5 sqmm FR PVC insulatedcopper conductor single core cablein surface/ recessed PVC conduit, 2way modular switch, modular plate,suitable G.I. box and earthing the |
| 790 | Wiring forcircuit / submain wiringalongwith earth wire with thefollowing sizes of PVCinsulated,copper conductor singlecore cable in surface/ recessed 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. PVC e) |
| 791 | 2 x 4 sq.mm. + 1 x 4 sq.mm. Earth |
| 792 | 2 x 6 sq.mm. + 1 x 6 sq.mm. Earthwire |
| 793 | Supply and fixing of following sizes ofPVC conduit along with accessoriesin surface/recess including cuttingthe wall and making good the samein case of |
| 794 | Supplying and drawing following pair0.5 mm dia FRLS PVC insulatedannealed copper conductor,unarmored telephone cable in theexistin |
| 795 | Supplying and fixing metal box offollowing size (nominal size) onsurface or recess with suitable size ofphenolic laminated sheet cover infromt including paintingetc. as 75 mm x 75 mm x 60 mm dee |
| 796 | Supplying and fixing following size /modules, GI box alongwith modularbase & cover plate for modularswitches in recess etc. as required.1 or 2 Module (75 mmX75 mm) |
| 797 | Supply and fixing modular blankingplate on the existing modular plate &switch box excluding modular plateas required. |
| 798 | Supply and fixing of suitable size GIbox with modular plate and cover infront on surface or in recess,including providing and fixing3 pin5/6 amps. modular socket outletand 5/6 amps. modular switch,connection, painting etc. as required. |
| 799 | Supply and fixing of suitable size GIbox with modular plate and cover infront on surface or in recess,including providing and fixing3 pin5/6 amps. modular socket outletand 5/6 amps. modular switch,connection, painting etc. as required. |
| 800 | Supplying and fixing following way,three pole and neutral, sheet steel,TP MCB distribution board, 415volts,on surface /recess, completewith tinned copper busbar, neutralbusbar, earth bar, din bar,detachable gland plate,interconnections, phosphatized andpowder painted including earthingetc. as required (But without MCB /4 way (4 + 12), Double door, |
| 801 | Supplying & fixing single pole,blanking plate in the existing MCB |
| 802 | 16 Installation of exhaust fanupto 450mm sweep in the existing opening,including making the hole to suit thesize of the above fan, making goodthe damage, connections, testing |
| 803 | Extra for fixing the louvers /shutters complete with frame |
| 804 | Earthing with GI earth plate 600mmx 600 mm x 6mm thick includingaccessories and providing masonaryenclosure with cover plate havinglocking arrangement and watering |
| 805 | Earthing withGI earth pipe4.5 mtrlong, 40 mm dia includingaccessories and providing masonaryenclosure with cover plate havin |
| 806 | Supplying and laying25 mm x 5 mm.G.I. strip at 0.50 M. below ground asstrip earth electrode, includingconnection and terminating with nut,bolt, spring, washer etc as required(jointing shall be done by overlapping |
| 807 | Providing and fixing 6 SWG dia G.I.wire on surface or in recess forloop earthing as required. |
| 808 | Providing and laying earthconnections from earth electrode with6 SWG dia G.I. wire in 15 mm diaG.I. pipe from earth electrode asrequired |
| 809 | S/F of single light wall bracket (CatAAA) on matching M.D.F.E.G. boardbase etc. complete in all respects.Category AA |
| 810 | S/F of recess/surface/pendentmounted 6 to 8 watt LED downlighter having powder coated diecast aluminium housing with heatsink, diffuser / reflector and driver setcomplete in all respect Category AAA |
| 811 | S/F of LED Tube Light with battensuitable for up to 1x22 watt LEDtube light fitting including tube onCategory AAA |
| 812 | Supply and fixing brass nickel platedcompression glands for PVCinsulated armoured, served,sheathed cable including rubber ringetc. complete in all respect. The50 sqmm 3 1/2 core |
| 813 | Construction of recess distributionboard of all sizes including cutting ofbrick work providing lintel of suitablesize & thickness plastering etc. withsupply of all materials, labours, T & Petc. required for proper completion ofwork. 600x480x200 mm. size |
| 814 | Supply and fixing of factory fabricatedM.S. box in existing sunk with Godrejtype almirah cover with handle etc.fabricated from 18 SWG M.S. sheetduly painted with red oxide primerfollowed by two coats of syntheticenamel paint complete withnecessary conduit entry andDP/TPN; fixing arrangement andprovision for compartment for loosewires, openable housing on the topand hold fast etc. including supply ofall material, labour and T & P etc.required for proper completion of thework.600x480x200 mm. size |
| 815 | Supply of AC 230/250 Volts, 50 Hz55w 1400 rpm exhaust fansincluding providing nuts, bolts,mounting frame and otheraccessories including connectionsetc. complete as required. 300mm sweep. |
| 816 | Providing and fixing water closet squatting pan(Indian type W.C. pan ) with 100 mm sand castIron P or S trap, 10 litre low level white P.V.C.flushing cistern, including flush pipe, with manuallycontrolled device (handle lever) conforming to IS :7231, with all fittings and fixtures complete,including cutting and making good the walls andfloors wherever requireda) Orissa Pattern W.C. pan of size 580x 440m withintegral type foot rests flush pipe and over flowarrangement |
| 817 | Same as above but for European type W.C. panwith black plastic seat and lid. Make |
| 818 | Providing & fixing white vitreous china wash basinwith C.I. brackets painted white, 15mm C.P. brasspillar taps, C.P. brass chain with rubber plug,32mm C.P. brass waste of standard patternincluding cutting & making good the walls wherevera) Flat back wash Basin size 550x400 mm withsingle 15mm C.P. brass pillar tap |
| 819 | Providing and fixing flexible P.V.C. waste pipe forsink or wash basin including PVC waste fittingsSemi rigid pipe 17.28.1a) 32mm dia |
| 820 | b) 40mm dia |
| 821 | Providing and fixing white vitreous china flat backhalf stall urinal of size 580x380x350 mm withwhite PVC automatic flushing cistern, with fittings,standard size C.P. brass flush pipe, spreaderswith unions and clamps (all in C.P. brass) withwaste fitting as per IS :2556, C.I. trap with outletgrating and other couplings in C.P. brassincluding painting of fittings and brackets, cuttingand making good the walls and floors whereverrequiredSCHEDULE OF QUANTITIES FOR PLUMBING WORKSPROPOSED TYPE - TOILET (SCHEDULED ITEMS AS PER D.S.R. 2023)DISTT. CODE-107106/107a) Single half stall urinal with 5 litre P.V.C.automatic flushing cistern |
| 822 | Providing & fixing 600x450mm bevelled edgemirror of superior glass (of approved quality)complete with 6mm thick asbestos cement sheetground fixed to wooden cleats with C.P. Brass |
| 823 | Providing & fixing PTMT towl rail complete withbrackets fixed to wooden cleats with cp brassscrews with concealed fitting arrangement ofapproved quality and colour. 600 mm. long towlrail length of 645 mm. width 78 mm. and effectiveheight of 88 mm, weighing not less than 190 gms. |
| 824 | Providing and fixing PTMT Liquid soap container109 mm wide ,125 mm high and 112 mm distance |
| 825 | Providing and Fixing C.P. brass Ablution healthfaucet assembly with 1.2 m long braided PVChose with mounting bracket fixed on wal |
| 826 | Providing and fixing C.P. brass Two-way anglevalve for EWC points & for fixing Ablution HealthFauct of approved quality conforming to IS:8931.15 mm nominal bore |
| 827 | Providing and fixing of upvc SWR ring fit pipe ofclass B of ISI mark Confirming to IS code 13592(make prince, supreme finolex) in internal works oftoilet and RWP etc. including fixing with rubberrings etc. including cost of all material, labour etc.complete.including excavation & trenches etccompletea) 110mm diameter |
| 828 | Haunching of SWR pipe 90mm or 110mm withpcc 1:5:10 cement concrete ( 1 cement:2 coarsesand:4 stone grit) ch-25 item no.2 |
| 829 | Supply and fixing of UPVC S.W.R. pipe nahni trapsize 100x75,110/90 mm confirming to IS-14735self cleaning design fixed in PCC 1:2:4 and supplyand fixing of 125 mm dia heavy duty CP brass jali |
| 830 | Supply and fixing of UPVC S.W.R. Cowelconfirming to IS-14735.(ch-23 item no.38)a) 100mm |
| 831 | b) 75mm |
| 832 | Providing and fixing on wall face unplasticisedRigid PVC rain water pipes conforming to IS :13592 Type A including jointing with seal ringconforming to IS : 5382 leaving 10 mm gap forthermal expansion . (i) Single socketed pipes.a) 110mm diameter |
| 833 | Making khurras 45x45 cm with average minimumthickness of 5 cm cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stoneaggregate of 20 mm nominal size) over PVCsheet 1m x 1 m x 400 micron, finished with 12 mmcement plaster 1:3 (1 cement : 3 coarse sand) anda coat of neat cement,punning,rounding the edgesand making and finishing the outlet complete.a) 110mm |
| 834 | Providing and fixing unplasticised -PVC pipe clipsof approved design to unplasticised - PVC rainwater pipes by means of 50x50x50mm hard woodplugs, screwed with M.S. screws of requiredlength including cutting brick work and fixing incement mortar 1:4 (1 cement : 4 coarse sand) andmaking good the wall etc. complete.a) 110mm |
| 835 | Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brassthreaded fittings including fixing the pipe withclamps at 1.00m spacing. This includes jointing ofpipes & fittings with one step CPVC solventcement and testing of joints complete as perdirection of Engineer in Charge.(internal work)i) Exposed on wall25mm dia nominal outer dia pipes |
| 836 | Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brassthreaded fittings i/c fixing the pipe with clamps at1.00m spacing. This includes jointing of pipes &fittings with one step CPVC solvent cement andthe cost of cutting chases and making good thesame including testiang of joints complete as perdirection of Engineer in Charge. Concealed workincluding cutting chases and making good thewalls etc. 16mm dia nominal outer dia pipes |
| 837 | 20mm dia nominal outer dia pipes |
| 838 | Providing and fixing 45 cm long unplasticised PVCconnection pipe with brass unions.a) 15mm nominal bore |
| 839 | Providing & fixing CP brass bib cock of approvedquality conforming to IS 8931a) 15mm nominal bore |
| 840 | Providing & fixing C.P. brass long body bib cockof approved quality conforming to IS standardsand weighing not less than 690 gms.a) 15mm nominal bore |
| 841 | Providing & fixing C.P. brass angle valve for basinmixer and gyser points of approved qualityconforming to IS 8931a) 15mm nominal bore |
| 842 | Providing and fixing ball valve (brass) of approvedquality complete. (High or low pressure withplastic floats).a) 25mm. Nominal bore |
| 843 | Providing and fixing brass stop cock of approvedquality.a) 15 mm nominal bore |
| 844 | b)20 mm nominal bore |
| 845 | Providing and fixing gun metal gate valve withwheel of approved quality.a) 25mm dia nominal bore |
| 846 | Providing and placing on terrace (at all floorlevels) polyethylene water storage tank ofapproved brand and manufacture with cover andsuitable locking arrangement and makingnecessary holes for inlet, outlet and overflowpipes but without fittings and the base support fortank. Capacity 1700 litre |
| 847 | Excavating trenches in all kind of soil of requiredwidth for pipes, cables etc. including excavationfor sockets and dressing of sides, ramming ofbottoms, depth upto 1.5 m. including getting outthe excavated soil & then returning the soil asrequired, in layers not exceeding 20cm in depth includingconsolidating each deposited layer by ramming,watering, etc & disposig of surplus excavated soilas directed within a lead of 50m.a) Pipes 80mm to 300mm diameter |
| 848 | Providing and fixing of UPVC SWR ring fit pipe ofclass B of ISI mark Confirming to IS code 13592(make prince, supreme finolex) in internal works oftoilet and RWP etc. including fixing with rubberrings etc. including cost of all material, labour etc.complete including excavtion trenches etc comp. ARa) 110mm diameter |
| 849 | b) 160mm diameter |
| 850 | Haunching of SWR pipe 90mm or 110mm or160mm with pcc 1:5:10 cement concrete ( 1cement:2 coarse sand:4 stone grit) AR |
| 851 | Providing and fixing square mouth S.W. Gully trapgrade 'A' complete with C.I. grating brick masonrychamber with F.P.S. bricks of class designation 75and water tight C.I. cover with frame of 300 x300mm. size (inside) the weight of cover to be notless than 4.50 Kg and frame to be not less than2.70 Kg as per standard design.a) 150 x 100 mm. size P type |
| 852 | Constructing brick masonry manhole in cementmortar 1:4 (1 cement :4 coarse sand) RCC topslab with 1:2:4 mix (1 cement :2 coarse sand :4graded stone aggregate 20mm nominal size),foundation concrete 1:4:8 mix (1 cement :4 coarsesand :8 graded stone aggregate 40mm nominalsize) inside plastering 12mm thick with cementmortar 1:3 (1 cement :3 coarse sand) finished withfloating coat fo neat cement and making channelsin cement concrete 1:2:4 (1 cement :2 coarsesand :4 graded stone aggregate 20mm nminalsize) finished with a floating coat of neat cementcomplete as per standard design 19.7a) Inside size 90x80 cm & 45 cm deep includingC.I. cover with frame (light duty) total wt. of cover& frame to be not less than 38 Kg (wt. of cover 23Kg & wt. of frame 15 Kg. |
| 853 | b) Extra for depth of man hole size 90x80 cm |
| 854 | Providing M.S. foot rests including fixing inmanholes with 20x20x10 cm cement concreteblocks 1:3:6 (1 cement:3 coarse sand :6gradedstone aggregate 20 mm nominal size) as perstandard design19.15With 20x20 mm square bar |
| 855 | Earth work in surface excavation not exceeding 30cm in depth but exceeding 1.5m in width as wellas 10 sqm on plan includinggetting out & disposal ofexcavated earth upto 1.5m asdirected by Engineer in charge Allkind of soil. In all kind of soil upto 1.5m depth |
| 856 | In all kind of soil upto 1.5m to3.0m. Depth |
| 857 | Providing and laying in positioncement concrete of specifiedgrade excluding the cost ofcentering and shuttering - Allwork up to plinth level :1:4:8 (1Cement : 4 coarse sand (zone-III)derived from naturalsources : 8 graded stoneaggregate 20 mm nominal size |
| 858 | First class brick work in 1:6cement and coarse sand mortarin foundation & plinth includingsupply of all materials, labour andT & P etc reqiored for propercompletion of the work |
| 859 | Reinforced cement concrete workin beams, suspended floors, roofshaving slope up to 15° landings,balconies, shelves, chajjas,lintels, bands, plain window sills,staircases and spiral stair casesabove plinth level up to floor fivelevel, excluding the cost ofcentering, shuttering, finishingand reinforcement with 1:1.5:3 (1cement : 1.5 coarse sand(zoneIII) derived from natural sources :3 graded stone aggregate 20 mmnominal size derived from naturalsources). SLAB |
| 860 | Steel reinforcement for R.C.C.work including straightening,cutting, bending, placing inposition and binding all complete |
| 861 | 15 mm cement plaster of mix 1:6(1 cement: 6 coarse sand) |
| 862 | Providing M.S. foot restsincluding fixing in manoholes with20x20x10 cm cement concreteblocks 1:3:6 (1cement : 3 coarsesand : 6 graded stone aggregate20mm nominal size) as perstandard design:(With 20x20mm |
| 863 | Providing and fixing C.I. tee at theinlet and outlet of septic tank. |
| 864 | P & F of SWR ring fit pipe ofclass B of ISI mark confirming toIS code 13592(makeprince,supreme finolex) in internalworks of toilet and RWP etc .Including fixing with rubber ringsetc including cost of allmaterial,labour rtc. Complete For |
| 865 | Making soak pit 2.5 m diameter3.0 metre deep with 45 x 45 cmdry brick honey comb shaft withbricks and S.W. drain pipe 100mm diameter, 1.8 m longcomplete as per standard designWith bricks of class designation |
| 866 | Cement concrete flooring 1:2:4 (1cement : 2 coarse sand : 4graded stone aggregate) finishedwith a floating coat of neatcement, including cement slurry,but excluding the cost of nosingof steps etc. complete. 11.3.1 40mm thick with 20 mm nominalsize stone aggregate |
| 867 | cost of washing pit |
| 868 | cost of houricultre work (pera 5.9.1) |
| 869 | Add 18%GST on Civil work for Muncipal colony |
| 870 | add 1% coutingincies |
| 871 | ADD 1.45 % FOR ARCHITECTURAL & STRUCTURALCONSULTANCY CHARGES TOTAL A Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail