| Sl. No. | Item Description |
| 1 | Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out hard/dense soil complete all as specified and directed. |
| 2 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any type of soil, complete all as specified and directed. |
| 3 | Returning filling in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm thick, complete all as specified and directed. |
| 4 | Removing excavated soil material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point, complete all as specified and directed. |
| 5 | PCC as in 1:4:8 type D-2 (Using 40mm graded stone aggregate) as in foundation filling and mass concrete, complete all as specified and as directed. |
| 6 | PCC as in 1:3:6 type C-2 (Using 40mm graded stone aggregate) as in foundation filling and mass concrete, complete all as specified and as directed. |
| 7 | RCC M-25 (20mm graded crushed stone aggregate) (Design Mix) for Foundations, including rafts, footings,foundation beams; plinth beams; bases for columns, etc.; basemen slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 8 | RCC M-25 (20mm graded crushed stone aggregate) (Design Mix) for slab supported on wallls, beams etc complete all as specified and directed. |
| 9 | RCC M-25 (20mm graded crushed stone aggregate) (Design Mix) for Beams, cantilevers, bressummers, lintels over 1.5m spancomplete all as specified and directed. |
| 10 | RCC M-25 (20mm graded crushed stone aggregate) (Design Mix) for Columns, pillars, piers, posts and struts, complete all as specified and directed. |
| 11 | Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, floor and roof slabs and shelves, horizontal or sloping and similar work exc 5cm but not exc. 10cm wide complete all as specified and directed. |
| 12 | Use and waste of form work to soffits of suspended slabs such as floor slab,landings and similar work not exc 200mm thick in rough finish surfaces of concrete complete all as specified and directed. |
| 13 | Mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 14 | All as per serial item no 13.00 here in before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, complete all as specified and directed. |
| 15 | Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in cement 1:6 all as specified and directed. |
| 16 | 75mm thick PCC 1:4:8 D-2 type (using 40 mm graded crushed stone aggregate) as in Sub base complete all as specified and directed. |
| 17 | Brick work with sub class B old size bricks straight or curved on plan any radius in half bricks thick wall built in cement mortar 1:4 complete all as specified and directed. |
| 18 | 15 mm thick rendering in cement mortar 1:4 with brick/concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 19 | 10 mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:6 and finished even and smooth, Complete all as specified and directed. |
| 20 | 5 mm thick cement plaster in cement mortar 1:4 on ceiling finishing even and smooth without using extra cement. |
| 21 | Supply only integral water proofing compound complete all as specified. |
| 22 | 50mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection finished even & smooth with out using extra cement incl making joints 10mm wide and 30mm deep at spacing n more than 2.5m and at corners at mandatory and filled with sealing compound grade A complete all as specified and directed. |
| 23 | 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub floor finished rough to receive topping layer complete all as specified and directed. |
| 24 | Non skid ceramic coloured tiles 7 to 8 mm thick, area of each tile exc 0.06sqm but n exc 0.11 sqm (min. size 300mm x 300mm), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.Note : Tile work shall be carried out with the use of Tile spacers. |
| 25 | Glazed ceramic coloured tiles in vertical surfaces of wall, of size 450mm x 350mm x 7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick rendering as in skirting in Cement mortar 1:4 complete all as specified and directed. |
| 26 | Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & ottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with uitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 27 | Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing. |
| 28 | 150 mm Extruded aluminium alloy handles, fabricated type, anodised |
| 29 | 100 mm Butt hinges, medium weight, cold rolled mild steel, and fixed. |
| 30 | M&L for 1000 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified . |
| 31 | 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed in position. |
| 32 | GI Unions,20mm brass to connect iron to polyethylene and fixed |
| 33 | Bib taps long body 15mm chroimum plated (ISI Marked with valid CML No) with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed including elbow/socket etc as required at site all as specified and directed by Engr-in - Charge. |
| 34 | 15mm bore size Stop valve of PTMT any colour high pressure screwed down with crutch or butterfly handle screwed both ends for for iron pipe for uinion and fixed . |
| 35 | 15mm bore size Pillar taps (fancy type) PTMT any colour high pressure screwed down with crutch or butterfly handle screwed both ends for for iron pipe for uinion and fixed .min weight- 120gms |
| 36 | 15 mm bore steel water Tubing 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors all as specified. |
| 37 | PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and as directed. |
| 38 | Concealed stop valve chromium plated brass fancy tap screwed down high pressure with crutch or butterfly handle bore dia 15mm screwed both ends for iron pipe or for unions and fixed including fittings as required at site,all as and directed by the Engr-in-charge. |
| 39 | PVC low level flushing cistern 10 ltrs capacity , valve less, syphonic action type, white, with inlet, ball valve, float and handle including brackets, PVC 32mm dia flushing pipe etc., fixed in repairs,complete all as specified and directed. |
| 40 | Vitreous China urinals, pedestal type, half stall (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe), complete all as specified and directed. |
| 41 | Urinal spreader of chromium plated for fixing with 15mm dia pipe. (Minimum weight 60gms), complete all as specified and directed. |
| 42 | S&F in repairs vitreous china wash down water closet pan `P` or `S` trap (pedestal pattern) white including fixing bolts,including connection to drain pipe (or out going pipe) and to flushing pipe, anti syphonage pipe etc complete all as specified and as directed. |
| 43 | S & F vitreous china counter top wash basin 600 × 450 mm over and including 18 mm thick polished granite slab, including supply of granite, cutting, edge moulding, polishing, cut-outs, fixing basin, sealing joints making necessary cut-out for basin and holes for waste, fixing basin in position with approved adhesive, sealing joints with white cement/silicone sealant, complete all as specified and as directed, complete all as specified and as directed. (NOTE: CP fittings and taps shall be measured and paid separately). |
| 44 | 110 mm bore PVC (SWR) pipes single socketed , in any length with rubber ring joints, fixed to walls complete all as specified and as directed. |
| 45 | 75 mm bore PVC (SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 46 | PVC (SWR) bends 75 mm bore any radius with oveal & acces door complete all as specified and as directed. |
| 47 | PVC (SWR) floor trap plain with grating including jointing with solvent cement (75 mm bore) complete all as specified and as directed. |
| 48 | PVC (SWR) junction single, (Single T)75mm equal or unequal complete all as specified and as directed. |
| 49 | S & F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed |
| 50 | Towel Rod CP Brass 20mm bore and 600mm long fixed with screw and plug complete all as specifed |
| 51 | Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 52 | S&F factory made mild steel ventilators box type with upper top hung shutters and bottom fixed type shutters including pintol hinges,steel peg stay and one shop coat of red oxide primer complete all specified.Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1302/2009 Sheet 1/3 to 3/3 ii) MS fillets, glazing, wire gauge shall be measured and paid separately. |
| 53 | 4mm thick figured glass, pin head type and glazing with oil putty or wooden beads in squares n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 54 | Preparing new plastered surfaces of wall and applying two coats of cement base paint over one coat of cement primer including 1 to 1.2mm thick exterior wall care putty ( to be applied in two coats) all as specified.Note: Putty surface shall be rubbed with emery paper to form even and smooth surface. |
| 55 | Preparing old plastered surfaces of wall and applying two coats of cement base paint over one coat of cement primer complete all as specified and as directed. |
| 56 | Preparation of newly plastered surfaces and applying two coats of oil bound distember over one coat of primer paint over complete all as specified and as directed. |
| 57 | Preparation of old plastered surfaces and applying two coats of oil bound distember over one coat of wall care putty complete all as specified and as directed. |
| 58 | Reinforced concrete pipe Class NP-2 laid and jointed complete with collars internal diameter 150 mm laid in trenches and complete all as specified and as directed . |
| 59 | PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore complete all as specified and as directed. |
| 60 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or type B-1 smooth finished, and reforming benching as required pipe in 150 mm. |
| 61 | Precast RCC cover slab (for manholes etc) cement concrete, 1:2:4, type B1, using 20mm graded stone aggregate as in slabs with plain faces including setting in CM 1:4 complete all as specified and as directed. |
| 62 | Rough excavation not exc 1.50 m deep and getting out in hard dense soil complete all as specified and as directed. |
| 63 | Excavation over area not exc 1.5m deep in any type of soil and getting out complete all as specified. |
| 64 | Walling of random rubble stone masonry uncoursed well bonded, bedded and solidly hearted, built in cement mortar (1:6) including providing weep holes complete all as specified (if PCC bond stone shall be measured and paid separately). |
| 65 | Precast cement concrete 1:3:6 type C1(using 20mm graded crushed stone aggregate) set in cement mortar 1:6 as in bond stones of any thickness and size or shape complete all as specified and directed. |
| 66 | Plain Cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping, benching including weathering slightly rounded or chamfered angles as directed including necessary form work and finishing the exposed surfaces complete, all as specified. |
| 67 | Extra over stone walling for hammer dressing to face stone and dressing of face beds and joints as specified of random rubble walling, uncoursed or brought up to course, hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 20mm for granite or trap stone , all as specified. |
| 68 | Hand packing (any thickness) of broken stone boulders at back of wall over arches etc and raising (or lowering) to the required label. |
| 69 | Forming embankments including raising (or Lowering) earth, spreading in layers not exc 30 cm thick watering ramming / rolling and finishing to reqd size, shape etc c., n exc. 1.5m high from base. |
| 70 | All as per Item No 69.00 here in before but ht exc 1.50 m but not exc 3.0 m from base . |
| 71 | All as per Item No 69.00 here in before but ht exc 3.00 m but not exc 4.50 m from base. |
| 72 | Dismantling of Asbestos cement (corrugated, semicorrugated, etc) sheets in roof coverings complete all as per specified. |
| 73 | Pre-painted coloured profiled galvalume sheet with min 0.5mm TCT with BTM of 0.45mm thick conforming to is 513 (AZ-150 GSM, AI zinc alloy metallic coating 550 Mpa yield stress as per AS-1397) as in roof covering/cladding to wall fixed with self tapping screws, colour/exterior coat of silcon modified polyster/BHPX RW paint system 20micron top coat applied over 5 micron primer all fixed with galvanised self drilling self tapping fastener 12-14x55 with EPDM seats complete all as specified and directed. |
| 74 | Pre-painted coloured plain steel profiled Galvalume sheet with min 0.5mm TCT with BTM of 0.45mm thick conforming to IS 513 (AZ-150 GSM, AI zinc alloy metallic coating 550Mpa yield stress as per AS-1397) in roof covering/cladding to wall fixed self tapping screws,colour/exterior of silcon modified polyster/BHPX RW paint system 20 micron top coat applied over 5 micron primer all fixed with galvanised self drilling self tapping fastener 12-14x55 with EPD seats complete all as specified and directed. |
| 75 | Demolition of brick work built in CM including all quoins arches pillars etc complete all as specified and directed. |
| 76 | Demolition of cement of any description in any position complete all as specified and as directed. |
| 77 | Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking key, scrubbing down with water, etc. complete all as per specified. |
| 78 | Machine cut kota stone slab flooring 18-20mm thick over cement screed base 15mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 79 | Kota stone slab 18-20mm thick in riser of steps, skirting , dado and pillar laid over 10mm thick rendering in CM 1:4 and jointed with pigment to match the shade of the sla bincluding rubbing and polishing complete all as specified and as directed. |
| 80 | Demolition of cement of conrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground) complete all as specified and as directed. |
| 81 | Hard core of gauge exc 63 mm but exc 100mm, deposited, spread and levelled in layersn.exc 15 cm thick, watered and rolled/rammed to a true surface of Broken stone boulders complete all as specified and as directed. |
| 82 | 100 mm thick Cement concrete type D-2, 1:4:8 using 40mm graded crushed stone aggregate as in sub base complete all as specified and as directed. |
| 83 | Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 grade grade complete all as specified and as directed. |
| 84 | Sand cushioning bed (filling under floors) in spreading levelling watering if required complete all as specified and as directed. |
| 85 | Providing precast cement concrete kerb stone type B-1 1:2:4 (20mm graded crushed stone aggregate) of any section as indicated with plain fair faces including champers, weathering, throating and setting in cement mortal 1:4 complete with joints to match complete all as specified and as directed. |
| 86 | Dismantling of wrought iron or mild steel dia work of any description complete all as specified and as directed. |
| 87 | Taking down roof trusses, coupled rafters or trussed beams clear span above 8 metres & upto 12 metres complete all as specified and as directed. |
| 88 | Mild steel work as in roof trusses (framed) trusses purlins cranes/gantries, rails & fastering & heavy bracket cleats (including distanence pleus cuats etc) Fe-410W (Gde-E-250 quality-A) complete all as specified and as directed. |
| 89 | Extra for forming fair finished drain or channel upto 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed. |
| 90 | Plain Cement concrete 1:2:4, type B-1, (using 20mm graded crushed stone aggregate), set in cement morter 1:4 in lintels upto 1.5m clear span, cills, steps: seismic and other similar bands, plinth courses, string courses, lacing kneelers, apex stones, bed plates and similar works including weathering, slightly rouinded for chamfered angles and throating and necessary form work, complete all as specified and as directed. |
| 91 | Preparation of new steel and iron surface of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 92 | Preparation of new concrete/plastered surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 93 | Preparation of old steel and iron surfaces exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over one coat or red oxide zinc chrome primer complete spray painting complete all as specified and as directed. |
| 94 | Granite (of any type) 18mm to 20mm thick work (table rubbed & polished) as in steps, jambs, pillars, window cills, cooking platforms and like, machine cut, bedded and jointed with grey cement slurry and pointed with white cemetn with admixture of pigment ot match the shade of granite stone laid over and including 20mm thick screed bed in CM 1:4 complete all as specified and directed by Engr-in-charge. |
| 95 | S&F powder coated Aluminium door air tight of anodised frame made of size 100 mm x 45 mm of section thickness 1.50 mm thick with one or more rebates including jointing cleats etc for fixing aluminium anodised door shutter fully panelled (two no of panels on each shutter) with 5.5 mm thick tinted glass as in panels shutter rail made of 80 mm x 45 mm of sheet thickness 1.50 mm (Top and bottom rails and stiles) single/ double leaf side hung type including necessary jointing cleats/ anodised aluminium fillets/ glazing clips with rubber gasket, with aluminium fittings such as aluminium anodised tower bolt 200 mm long 03 No for each door, aluminium anodised bow handles 150 mm ‘D’ type 02 Nos for each shutter, mortice locks 6 lever make – harrison one on each door, door shutter mounted on bottom double action floor spring hydraulically regulated made up of 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing mild steel heavy duty and door shutter to open out on aluminium alloy pivot. 01 No on each shutter bottom and floor stoppers complete all as specified and as directed.Note: All fitting shall be of ISI marked except cleats) sized of each door shall be as per site requirement all as directed and specified. |
| 96 | S&F powder coated Aluminium for partition of anodised frame made of size 100 mm x 45 mm of section thickness not less than 1.50 mm thick with one or more rebates including jointing cleats etc for with 5.5 mm thick tinted glass as in panels complete all as specified and as directed.Note: All fitting shall be of ISI marked except cleats) sized of each door shall be as per site requirement all as directed and specified. |
| 97 | S&F 5.5 mm thick tinted sheet glass ordinary quality and glazing with oil putty or wooden beads in squares exceeding 0.50 Sqm in each pane complete all as specified and directed by Engr-in-charge. |
| 98 | S&F false ceiling with fibre cement (designer tile ivory painted (high pressure steam cured) of 4 mm thickness (as per IS:14862) of size 595 x 595 mm and any one of the design (oceanic, lake & hill, cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms both side inclusive) consisting of main ‘T’ runner with suitably spaced joints to get required length, and 15x32 mm made of 0.30 mm sheet, and cross ‘T’ at 600 mm c/c to form a grid including required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ‘T’ runners to be suspended from ceiling using GI soffit cleats fixed to existing rafter, purlin, etc with galvanized butterfly level clips, spaced at 1200 mm c/c. Main ‘T’, bottom exposed width of 15 mm of all T-sections shall be centre black pre painted with polyester paint, and having a load bearing capacity of 12 kg/sqm, and refixed all existing electric wiring and fixture all complete all as specified and as directed. |
| 99 | Coloured vitrified (double charged) tiles 1200 x 600 x 10 mm thick (rectangular) polished, in floor etc, set and jointed with spacer and laid with epoxy grouted in cement slurry and pointed in white or coloured cement to match over and including 10 mm thick screed bed in cement mortar (1:4) complete all as specified and as directed. |
| 100 | S&F of antique tYpe curtain rods with double bracket system and onion type end brackets all as per aproved design and pattern complete all as specified and as directed. |
| 101 | Excavating in post holes (or similar holes) as in any type of soil each n exc 0.5 cu. m, getting out,returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, complete all as specified and directed. |
| 102 | M&L for factory made precast cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) kerb stones of size 300mm in width, 100mm thick & 350mm in depth, bedded and jointed in CM 1:4 with matching joints, complete all as specified and directed. |
| 103 | 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and as directed. |
| 104 | M&L for Point wiring using approved color coding as per IS code (Red,Black and Green for single phase circuit) with multi stranded copper condutor 1.5 Sqmm nominal cross section area,single core,PVC insulated and unsheathed FRLSH cable 1100V grade,in and including medium grade,PVC concealed conduit ISI marked of dia not less than 20mm and conduilt accessories concealed in wall/roof/floor etc with including Tee, Junction boxes and provision of 3 mm thick plastic laminated sheet cover of suitable size on existing terminal boxes with new brass screws for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly for one light/Fan/exhaust fan point controlled by one Switch complete all as specified & directed for the following:- One light Point controlled by one,one way switch. |
| 105 | One ceiling fan controlled by one way switch. |
| 106 | One 5 Amp independent board controlled by one SP switch. |
| 107 | Point wiring using approved color coding as per IS code (Red,Black and Green for single phase circuit) with multi stranded copper condutor 1.5 Sqmm nominal cross section area,single core,PVC insulated and unsheathed FRLSH cable 1100V grade,in and including medium grade,PVC concealed conduit ISI marked of dia not less than 20mm and conduilt accessories concealed in wall/roof/floor etc with terminated to new pressed flush metal box and readily available cover with outer plates and inner plates etc, suitable for mounting modular type switches , sockets, fan regulators etc PVC insulated PVC insulated multistranded copper condutor 1.5 sqmm nominal cross section area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly for one 5 pin modular socket outlet two in one 16/6 Amps on an independent board including making good distrurbed surfaces complete all as specified and directed:- |
| 108 | M&L for Point wiring using approved color coding as per IS code (Red,Black and Green for single phase circuit) with multi stranded copper condutor 1.5 Sqmm nominal cross section area,single core,PVC insulated and unsheathed FRLS cable 1100V grade,in and including medium grade,PVC concealed conduit ISI marked of dia not less than 20mm and conduilt accessories concealed in wall/roof/floor etc with terminated to new pressed flush metal box and readily available cover with outer plates and inner plates etc, suitable for mounting modular type switches , sockets, fan regulators etc PVC insulated PVC insulated multistranded copper condutor 1.5 sqmm nominal cross section area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following:-One light point controlled by one , one way switch. |
| 109 | All as per serial item no 108.00 here in before but for 3 pin 5 Amp modular socket on the same board, complete all as specified. |
| 110 | All as per serial item no 108.00 here in before but for 3 pin 5 Amp modular socket on independent board, complete all as specified. |
| 111 | Taking down carefully alu./copper point wiring ,light, fan socket, or power complete with (fittings such as old rusted steel conduit switches ceiling rose pendants, regulators, socket etc to be measured separately ) removing material to store for disposal by Sch of credit and making good to disturbed surfaces of walls floors etc and all as specified. |
| 112 | Dismantling and taking down fluorescent tube light single/double of any wattage or size fittings for repair or replacement of burnt/worn out accessories or carrying to MES store for reuse or taking in schedule of credit |
| 113 | Taking down unserviceable/serviceable MCB DBs/Acs box including MCCB/MCBs ofa nay type and size complete all as specified and as directed. |
| 114 | Modular switch single pole one way 6 amps 240 volts with polycarbonate body complete all as specified and directed.. |
| 115 | Modular socket 6 amps 5 pin flush type, 240 volts. with polycarbonate body. complete all as specified and directed.. |
| 116 | Modular socket out let,5 pin 6amps and 15 amps multi purpose 2 in 1 flush type, 230 volts with polycarbonate body.complete all as specified and directed. |
| 117 | Modular switch single pole one way 16 amps 240 volts with polycarbonate body complete all as specified and directed.. |
| 118 | Ceiling rose surface bakelite type 65x50mm three terminals complete all as specified and as directed. |
| 119 | S&F 20 Watt LED light fitting, 220/230 Volts, AC, decorative box type with driver holder including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. |
| 120 | S&F in replacement 18 Watt LED light fitting, 220/230 Volts, AC, decorative box type with driver holder including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. |
| 121 | S&F 10 Watt LED light fitting, 220/230 Volts, AC, decorative box type with driver holder including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. |
| 122 | Supply and fixing of MCB Metallic Distribution board 12 way, double door, 230 Volts concealed flush to wall for mounting MCBs factory made, conforming to IS : 13032 fabricated out of CRCA sheet fitted with DIN channel, neutral link and appropriate rated bus bar DBs shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature, between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The DBs shall be of same make as MCBs, DB shall also be provided with lable marking indicating the incoming and outgoing circuits on all ways as specified, the DBs shall be of IP 43 protection complete all as specified and directed. |
| 123 | S&F for 63 Amp current rating, 240V, 50Hz 10KA 'B' series SP Miniature Circuit Breaker(MCB) in MCB DB Complete with connection testing and commissioning all as specified. |
| 124 | S&F for 40 to 63 Amp current rating, 240V, 50Hz 10KA 'B' series SP Miniature Circuit Breaker(MCB) in MCB DB Complete with connection testing and commissioning all as specified. |
| 125 | S&F for 6 to 32 Amp current rating, 240V, 50Hz 10KA 'B' series SP Miniature Circuit Breaker(MCB) in MCB DB Complete with connection testing and commissioning all as specified. |
| 126 | S&F exhaust fan, steel body, AC, single phase, 230 Volts of size 300mm sweep with blades and frame and louver, complete all as specified and directed. |
| 127 | Supply and laying G.I pipe Light grade with all fittings required for protection of under ground cable including cutting of road/flooring surface wherever required and making good to match with existing floor/surface of size 40 mm dia all as specified and directed. |
| 128 | S&F 35 Watt LED security light fitting with street light, made up of pressure die-cast housing with toughened glass and high power LED's with secondary optics and IP-66 protection and with 0.60 mtr long 20/25mm dia (as per manufacturer's standard) GI Pipe light grade in 45 degree bend shape and necessary clamping devices of suitable size, complete all as specified and directed. |
| 129 | S&F in replacement 35 Watt LED security light fitting with street light, made up of pressure die-cast housing with toughened glass and high power LED's with secondary optics and IP-66 protection and with 0.60 mtr long 20/25mm dia (as per manufacturer's standard) GI Pipe light grade in 45 degree bend shape and necessary clamping devices of suitable size, complete all as specified and directed. |
| 130 | M&L for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick buried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below Normal ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised earth lead wire 4.0mm dia by means of GI nuts, bolts and washers of galvanised iron or steel all as shown in electrical plate no.5 connecting to earth test point all as specified or indicated including testing on completion with following:-(a) Test point GI wire 4mm dia . (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embedded in floor of PCC earth pit. (GI Funnel should properly tightened on GI watering pipe and embedded in PCC floor of earth pit with open top suitable for watering of earth pits)(c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.(d) Angle iron frame made of 40x40x4 mm angle iron for 30x30 mm PCC pit for holding the pit cover. |
| 131 | M & L for single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 16 to 32 amp Amps \\"C\\" Curve 10kA, 240 volt capacity complete all as directed. |
| 132 | S&F electric water heater, storage type, steel body with copper inner tank and heating element upto 2 KW of capacity 25 litres, BEE 5 Star rated, complete with all accessories such as safety valve, thermostate, NRV, connection piece etc and directed. |
| 133 | M&L for laying / fixing and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core in trenches/floor/pole/GI pipe complete including cutting/chasing to any surface and making good to the disturbed surface to match the existing. |
| 134 | M&L for laying / fixing and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 2 core in trenches/floor/pole/GI pipe complete including cutting/chasing to any surface and making good to the disturbed surface to match the existing. |
| 135 | M&L for dry sand cushioning to under ground cables provided with a layer of sand 8 cm deep before laying the cable, 15 cm deep after laying the cable & stretching the cable all as specified and directed. |
| 136 | Supply and lay well-burnt clay bricks sub-class ‘B’, covering as mechanical protection to cable all as specified. |
| 137 | Switch Piano, flush type, One way, single pole, 5 Amps, suitable for 240 V, 50 Hz, AC supply complete. |
| 138 | Two in one, 3 Pin, 5 Amps, flush type socket outlet complete |
| 139 | S&F in replacement of Switch socket combination piano type 5 pin 5 Amps flush type fixed in replacement, complete all as specified and directed by Engineer-in-Charge. |
| 140 | S&F in replacement of Switch socket combination piano type 6 pin 16 Amps flush type fixed in replacement, complete all as specified and as directed.. |
| 141 | Supply and Fixing in replacement of high bay light fitting of 70 Watt Cavelo Trade is an integrated well glass luminaire with die cast canopy & gear housing. A versatile well glass series with both eye bolt & cradle for multiple mounting options. This IP66 well glass series delivers 120 lumens per watt complete with testing all as specified and directed. |
| 142 | Supply & fix Air Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting complete all as specified and as directed. |
| 143 | M&L Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead strip 25x4mm size by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-5 of MES Part-1 fixed in replacement including testing on completion including the material and labour of the following :-(a) Excavation and earth work for drilling hole for electrode in any type of soil.(b) PCC Pit in cement concrete 1:2:4 type B-1.(c) Precast RCC cover with suitable handle 40mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm.(d) Funnel with watering pipe of GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering.(f) Requisite quantity of common salt and charcoal.(g) Testing of Earthing.Note : (a) On testing after completion of earthing, if the desired earth resistnace is not obtained, the earthing will be done by the contractor at his own risk and cost to the entire satisfaction ot the engineer incharge.(b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing. |
| 144 | S&F single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar, neutral link, earth bar and din rail, suitable for use on 240 Volts, 50 Hz supply double door SPN DB system 8 ways, complete all as specified and directed. |
| 145 | S&F stepped type electronic fan regulator, flush type on the existing phenolic laminated sheet as required, complete all as specified and directed. |
| 146 | S&F ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 Volts, 1200mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE, 5 Star rated with brushless direct current motor (BLDC), complete all as specified and directed. |
| 147 | S&F sub main wiring with two run single core 6.0 Sqmm FRLS copper conductor cable PVC insulated 1100 Volts grade including PVC casing & capping, medium grade, ISI marked with all accessories such as Tees, elbows, junction boxes etc. as required, fixed on wall alongwith one run of 6.0 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board complete and testing on completion, complete all as specified and directed.Note : Two run of 6 sqmm and one run 6 sqmm cable and one run of PVC conduit shall be measured as one RM |
| 148 | S&F surface/recessed mounting LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by engineer in charge S&F in repair rigid non - metalic PVC casing caping of 25/12mm inclusive of all elbow, tees,etc complete all as per the direction of Engr-in-Charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail