| 1 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.Ref. Page -10, Item -1,c, PWD SOR Vol-I w. e. f. 1.11.2017 |
| 2 | Labour for scrapping and picking up old dilapidated mortar / plaster (Cement / Surki / Lime mortar) from the surface of old Brick faces including cleaning the frog without damaging the Brick and stacking the Bricks at Site / Stacking yard as per direction of Engineer-in-charge including removing all debris rubbish from site complete.Ref. Page -13, Item -18, PWD SOR Vol-I w. e. f. 1.11.2017 |
| 3 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof.Ref. Page -10, Item -2, PWD SOR Vol-I w. e. f. 1.11.2017 |
| 4 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1.5 mRef. Page -1, Item -2 a), PWD SOR Vol-I w. e. f. 1.11.2017 |
| 5 | Supplying and laying Polythene Sheet (150gm / Sq.M) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. Ref. Page -47, Item -3, PWD SOR Vol-I w. e. f. 1.11.2017 |
| 6 | Cement concrete with graded jhama khoa (30 mm size) excluding shuttering In ground floor and foundation. (a) 1:3:6 proportionRef. Page -23, Item -1a), PWD SOR Vol-I w. e. f. 1.11.2017 |
| 7 | Brick work with 1st class bricks in cement mortar (1:6)Ground Floor(b) In superstructure, ground floorRef.Page -15, Item -8 a), PWD SOR Vol-I w. e. f. 1.11.2017 |
| 8 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.(a) Pakur VarietyRef. Page -24, Item -4, PWD SOR Vol-I w. e. f. 1.11.2017 |
| 9 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding / staging where necessary (Ground floor).Ref. Page - 189, Item 1 PWD SOR VOL-I w.e.f. 1.11.2017 |
| 10 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc.NOTE : Cement 0.152 cu.m. per 100 sq.m.Ref. Page -192, Item -15, PWD SOR Vol-I w. e. f. 1.11.2017 |
| 11 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.(a) Pakur VarietyRef. Page -24, Item -4, PWD SOR Vol-I w. e. f. 1.11.2017 |
| 12 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(a) Pakur VarietyRef. Page -15, Item -7a), PWD SOR Vol-I w. e. f. 1.11.2017 |
| 13 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction ofEngineer-In-Charge.Ref. Page - 42, Item 36,a; PWD SOR VOL-I w.e.f. 1.11.2017 |
| 14 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor/upto 4 mII. JSW/JSPL/ SHYAM/ SRMB/ BMASL/ ELECTROSTEEL/ SSLRef. Page - 44, Item 40,b,i; PWD SOR VOL-I w.e.f. 1.11.2017 |
| 15 | Deduction of 1st class brick from dismantaling previous wall 1st Class Bricks (kiln burnt)Vide - Page -299, Item -1 Volume I :PWD SOR VOL-I w.e.f. 1.11.2017 |
| 16 | Add 18% GST |
| 17 | Add 1% Cess Please Enable Macros to View BoQ information |