| 1 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.In 1st floor including roof |
| 2 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.In 1st floor including roof.upto 150 mm. thick |
| 3 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. |
| 4 | Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific directionof the Engineer-in-charge) |
| 5 | Removing loose scales, blisters etc. from old painted surface and thoroughly smoothening the surface to make the same suitable for receiving fresh coat of paint. |
| 6 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 7 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 8 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary.(a) On steel or other metal surface :With super gloss (hi-gloss) - Two coats (with any shade except white) |
| 9 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary.(b) On timber or plastered surface :With super gloss (hi-gloss) - Two coats (with any shade except white) |
| 10 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal /Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge |
| 11 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. (Pakur variety) i) In ground floor and foundation. |
| 12 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Exxcluding cost of chipping over concrete surface.](A) With 1:4 cement mortar(i)In ground floor (15 mm thick plaster) |
| 13 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE: Cement 0.152 cu.m. per sq.m. |
| 14 | Renewing 10 litre P.V.C. low-down cistern conforming to I.S. specificatioons with P.V.C. fittings completre, C.I. brackets including two coats of painting to bracket etc. |
| 15 | Renewing bib cock or stop cock. |
| 16 | a) Chromium plated Stop cock [Equivalent to Code No.513(A) & 513(B) & Model - Tropical/Sumthing of ESSCO or similar brand] |
| 17 | b) Chromium plated Bib Cock Short body [Equivalent to Code No.511 & Model - Tropical/Sumthing special of ESSCO or similar brand] |
| 18 | c) PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm |
| 19 | Renewing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. |
| 20 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 nmetre from top with 20 mm. thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15 mm. thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm. thick cement plaster (1:4) on the top the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm. to 63 mm. size0 including R.C.C. cover slab of 100 mm.thick with cement concrete (1:1.5:3) with stone chips with necessary reinforcements and shuttering including one 560 mm. dia. R.C..C. manhole cover (heavy type) of approved make supplied, fitted and fixed in the cover slab with necessary fitings, making necessary arrangementsfor pipe conections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. (SAIL/TATA/RINL) With 250 mm. thick dry brick work and 250 mm. thick cement brick work (6:1) and 1.00m. Inside dia.i) With Pakur variety (JSW/Shyam/SRMB/BMASL/ELECTROSTEEL/SSL) |
| 21 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6 mm.nominalsize) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes.a) Pakur Variety. |
| 22 | Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with waterin proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification |
| 23 | Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps.750 mm long |
| 24 | Supplying P.V.C. water storage tank of approved quality with closed topwith lid (Black) - Multilayer(b) 1000 litre capacity |
| 25 | Labour for punching hole in plastic water storage tank upto 50 mm dia. |
| 26 | Labour for hoisting plastic water storage tank. Upto 1500 litre capacity.Upto 1st story from G.L. |
| 27 | Labour for lowering plastic water storage tank and stacking in places asdirected. Upto 1500 litre capacity.From 1st floor to G.L. |
| 28 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) |
| 29 | (ii) 25 mm dia |
| 30 | (iii) 20 mm dia |
| 31 | (iv) 15 mm dia |
| 32 | Supply of G.I. plug |
| 33 | Supply of long screw (150 mm long) of TATA make with sockets (TATAmake) and jamnut. |
| 34 | Supply of G.I. union |
| 35 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992Single Socketed 3 Meter Length (a)110 mm |
| 36 | Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin-charge. (Payment will be made on centre line measurement of the total pipeline including specials. (a) Above ground - (a) 110 mm |
| 37 | (b) Below ground (i) 110 mm |
| 38 | Making connection with the existing pit. |
| 39 | Roof treatment by applysing of non toxic poilyurethene modified acylic based isngle component (P U Roof Coat) solven5t free, cold applied polyurethene modified elastometric waterproofing membrane with excellent UV resistant capacity as per ASTM D6083 [a water based 100% acrylic elastometric emulsion polymer latex coating used as protective coating for roofs] after preparing the surface by cleaning and repairing the roof cracks by cement and sand morter (1:4), preferably with priming coat (two coats of P U Roof Coat and one cat of primer compatible with the main product as per the manufacturer specication) and reinforced with or without 20 gsm Geotextile Fleece, including the cost of primer coat and base preparation , tools & plants but exlcuding the cost of scaffolding and stagging complete as per direction of engineer-in-charge |
| 40 | Renewing approved quality best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. 3mm thick (weighing 7.4 Kg/ sqm). |
| 41 | Renewing worn out putty of glass panes. Panes not exceeding 0.2 Sq.m |
| 42 | Extra for fixing glass panes in steel window. |
| 43 | Cutting chase upto 125 x 150 mm. and subsequent mending of damages.(a) in brick wall |
| 44 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (Oxidised) 100 mm x 50 mm x 1.25 mm |
| 45 | Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.300 mm long. |
| 46 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: |
| 47 | 100mm long x 10mm dia. bolt. |
| 48 | 150mm long x 10mm dia. bolt. |
| 49 | Supplying, fitting and fixing closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. |
| 50 | Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. With 'P' trap |
| 51 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specificatioons with P.V.C. fittings completre, C.i. brackets including two coats of painting to bracket etc. |
| 52 | Supplying fitting & fixing UPVC Pipes A type and fitttings conforming to IS 13592-1992 with all necessary clamps, nails including making holes in walls, floors etc cutting trenches in any soil through masonary concrete structures etc, if necessary, and mending good damages including joining with jointing materials (Spun yarn, valamoid / bitumen/ M-Seal, etc.) complete. |
| 53 | a) UPVC Pipes. 110 mm |
| 54 | b) Plain Tee (UPVC), 110mm dia. |
| 55 | c) UPVC Shoe, 110mm dia. |
| 56 | d) Bend 87.5 degree, 110 mm dia. |
| 57 | e) Plain Y , 110 mm. Dia. |
| 58 | Renewing flat back urinal (half stall in urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm x 75 mm. x 75mm. Wooden blocks complete.470 mm X 280 mm X 340 mm |
| 59 | Labour for dismantling G.I. pipe with fittings.25 mm dia. |
| 60 | Refixing G.I. pipe with fittings after cleaning where necessary. 25 mm dia. |
| 61 | Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades. |
| 62 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive distemper / acrylic emulsion paint including scrapping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of E.I.C One coat. i) Water based interior grade Acrylic Primer |
| 63 | Applying Acrylic emulsion paint of approved make and brand on walls and ceiling including sand papering in intermidiate course including putty (two coats). Standard Quality. |
| 64 | Application of priming coat for standard bituminous waterproofing treatment over flat roof with Bitumen primer of approved brand fufilling the provision of I.S. 1346 - 1991 & 3384 - 1986 applied @ 0.27 Liters /Sq.m. over clean and prepared roof surface complete as per satisfaction of theEngineer - in - Charge. |
| 65 | Repairs to roof cracks with cement and sand mortar (1:4) including cutting grooves and cleaning cracks and grouting the cracks with neat cement before repairs. (Cement 0.63 Kg/Mtr. ) |
| 66 | Taking out old damaged tarfelt from the roof, parapet etc. preparing the roof surfaces by removing all spoils, blisters, moss etc. from the working site and disposal of the same beyond the compound and cleaning the site in all respect as per direction of Engineer-in-Charge |
| 67 | Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer's specification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.).Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N:300 (longitudinal), 200 (transverse) |
| 68 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,PartI. Payment will be made separetly on the basis of actual height based on relevantI.S.Code.For 20 users[With Pakur variety (JSW/Shyam/SRMB/BMASL/ELECTROSTEEL/SSL)] |
| 69 | (a)Applying Exterior grade Acrylic Primer of approved quality and brand on plastered or concretesurface old or new surface to receive decorative textured (mat finish) or smooth finish acrylic exterior Immersion paint including scrapping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of E.I.C |
| 70 | One coat on new surface. |
| 71 | (i)In ground floor. |
| 72 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat)a) Normal Acrylic Emulsion |
| 73 | Brick work with 1st class bricks in cement mortar |
| 74 | i) In foundation & plinth |
| 75 | 125 mm thick brick work with 1st class bricks in cement mortar (1:4) |
| 76 | i)In superstructure, ground floor. |
| 77 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 78 | Earth work in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite or sand stone) including removing,spreading or stacking the spoils within a lead of 75 m. as directed.The item includes necessary trimming the sides of trenches, leveling,dressing and ramming the bottom, bailing out water as requird complete. |
| 79 | a) Depth of excavation not exceeding 1500 mm |
| 80 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) |
| 81 | (a) With earth obtained from excavation of foundation. |
| 82 | Filling in foundation or plinth by medium course sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) Do - by fine sand |
| 83 | MS work in cable trench, cover slab, chaquered plate, clamp, cleats, brackets, etc. made from flat angle channel, tees, chequered plates 6mm thick, etc including necessary cuting to size fabricating, drilling of holes, forgeing, welding, revating, tightening with bolts and nuts with necessary washers including errection, fitting and fixing in position with all labour and materials, complete as per drawing and direction. |
| 84 | Supplying fitting & fixing 1st quality Ceramic Tiles in walls & floors to match with the existing works and four no of key stones (10mm) fixed with araldite at the back of each tiles and finishing the joints with white cements mixed with colouring oxide if required, to match the colour of tiles including roughening of concrete surface , if necessary, or by synthetic adhesive and grout materials etc. |
| 85 | (A) Floor :-With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. |
| 86 | Area of each tile upto 0.09 Sq.m |
| 87 | (i) Coloured decorative |
| 88 | a)In ground floor |
| 89 | Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor).Sizes-300 mm x300mm x10 mm with breaking strength > 1200 N. |
| 90 | Refixing wash basin with brackets with or without waste fittings |
| 91 | Wash basin vitreous china of approved make (without fittings)supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm woodblocks and C.I. brackets including two coats of painting of C.I. brackets.(i) 550 mm X 400 mm size |
| 92 | Renewing P.V.C. water storage tank of approved quality with closed top with lid ( Black ) - Multilayer(a) 1000 litre capacity |
| 93 | (i) Labour for hoisting plastic water storage tank. Upto 1500 litre upto 5000 litre capacity. Upto 1st story from G.L. |
| 94 | (ii) Extra for each additional story |
| 95 | (b) Labour for punching hole in plastic water storage tank upto 50 mm. dia |
| 96 | Supplying, Fitting & Fixing Factory made P.V.C. door frame of size 50 mmx47mm with a wall thickness of 5 mm, made out of extruded 5 mm, PVC sheet miter cut at two corners and joined with two nos of 1.5 mm long brackets of 15 mm x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19mmx 19 mm M.S. Square tube of 19 gauge, weather seal to be provided through out the frame. The door frame shall be fixed with the wall using 65/100 mm long M.S. Screws through the frame by using P.V.C fasteners. A minimum of 4 Nos of screws to be provided for each vertical member and minimum 2 Nos for horizontal member etc. complete as per Manufacturer‟s specification and direction of Engineer-in-Charge. |
| 97 | PVC Door Shutter-30 mm thick: Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of 59 mm x30 mm section with 2.0 mm (+/-0.2 mm) wall thickness.Horizontal & vertical section shall be fixed to each other by self tapping screws and 1 solid polymeric or M.S. galvanised tubular 'L' shaped bracket 100mm x 200mm in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 120 mm x30mm with 2.0 mm (+/- 0.2mm) wall thickness will be fitted in the middle, reinforced by solid polymer bar of 200 mm long at both ends and screws from both sides as lock rail. The section frame will then be fitted in by PVC panels of size 100 mmx25 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials, labour, and hire of tools and plants and appliancesi/c carriage of all materials taxes and all other incidental charges complete. Please Enable Macros to View BoQ information |