| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:Rate for a lead upto 1 meter fromcutting edge All kinds of soil. |
| 2 | Providing & Laying of stone soling (dully hand packed)including watering dressing and ramming with all carriages loading un-loading and stacking etc complete |
| 3 | Providing & laying in position cement concrete of specified grade excld. The cost of centring and shuttering all work upto plinth level(1:4:8 coarse sand 40mm nominal size crushed stone agg.) |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 5 | Brick work with FPS bricks of class designation 75 in foundation and plinth in cement mortar 1:6 (1 cement, 6 coarse sand) |
| 6 | Extra Brick work in super structure above plinth level upto floor V Level ( by manual means). |
| 7 | P/L in position specified grade of reinforced cement cencrete excld. The cost of centring, shuttering, finishing and reinforecement-All work upto plinth level. 1:1.5:3 graded stone agg. 20mm nominal size |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate |
| 9 | Reinforcement for RCC work incld straightning, cutting, bending, placing in position & binding all completeThermo-Mechanically Treated bars of grade Fe-500D or more |
| 10 | Structural steel work in single section, fixed with or without connectingplate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 11 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown |
| 12 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 13 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 14 | Finishing walls with water proofing cement paint of required shade onNew work (two or more coats applied @ 3.84 kg/10sqm) |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns |
| 16 | Centring and shuttering incld. Strutting, proping etc & removal of form work for suspended floors, roofs, landings, balconies & access plateform |
| 17 | Providing and fixing soil waste pipes 100mm dia PVC B Class i/c all necessary fittings like collars, bends etc as per requirement. |
| 18 | Providing and fixing 75mm dia PVC B class i/c all necessary fittings like collars, bends etc as per requirement. |
| 19 | Providing and fixing of PVC Floor Trap with Jali 100mm of approved brand including all fittings and fixtures complete. |
| 20 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge.Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. PN-16 pipe , 20mm OD(SDR-7.4) |
| 21 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge.External work including trenching, refilling etc. i/c all fittings . PN-16 pipe , 20mm OD(SDR-7.4) |
| 22 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 23 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 24 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved brand conforming to IS : 8931 |
| 25 | Providing and fixing 15 mm nominal bore CP brass Angle valve of approved brand |
| 26 | Providing and fixing uplasticized PVC connection pipe with brass unions 15mm nominal bore. |
| 27 | Construction brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) R.C.C top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design. with F.P.S bricks with class designation 75 & with crushed stone aggregate.including cover with frame complete: size 1'-6\\"x1'-6\\"x1\\"-0. |
| 28 | Providing and lowereing of RCC Rings (1:2:4 Mix) of 36\\" Dia 8\\" height and 2\\" thick i/c RCC cover with all carriages complete i/c earth work in excavation complete job. |
| 29 | Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead upto 50 m and lift upto 1.5 m |
| 30 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work |
| 31 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 32 | Carriage of materails By Mech.Transport, from source to site of work |
| 33 | Stone agg. for an avg lead of 10 km |
| 34 | Sand for an avg lead of 5 km |
| 35 | Providing and fixing MS sign board 2'x3' i/c lettering complete as directed by Engineer-incharge complete job Please Enable Macros to View BoQ information |