Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Appendix A- Administrative Block |
| 2 | 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 3 | 2.33.1:Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth |
| 4 | 2.33.2:Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth |
| 5 | 2.33.3:Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth |
| 6 | 2.33.4:Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Above 240 cm girth |
| 7 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 8 | 50.2.26.1:Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge. |
| 9 | 50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge |
| 10 | 2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 11 | OD377006/2025-2026:Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).450 mm dia piles |
| 12 | OD378086/2025-2026:Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).500 mm dia piles |
| 13 | 20.6.2.1:Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Single pile above 50 tonne and upto 100 tonne capacityInitial test (Test Load 2.5 times the Safe capacity) |
| 14 | 20.6.2.2:Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Single pile above 50 tonne and upto 100 tonne capacityRoutine test (Test Load 1.5 times the Safe capacity) |
| 15 | 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 16 | OD317073/2025-2026:OD based on 5.33.1.1 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.All work upto plinth level Concrete of M30 grade with minimum cement content of 340 kg /cum |
| 17 | OD317072/2025-2026:OD based on 5.33.2.1 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All work above plinth level upto floor V levelConcrete of M30 grade with minimum cement content of 340 kg /cum |
| 18 | 5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 19 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 20 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 21 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 22 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 23 | OD374679/2025-2026:Diluting and injecting chemical emulsion for PRE -CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (BASED ON 2.35.3.1) |
| 24 | 4.17:Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 25 | 2.34.1:Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos / Lindane emulsifiable concentrate of 20% |
| 26 | 6.47:Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry150mm/230mm/300 mm thick with Grade- I AAC blocks in super structureabove plinth level up to floor V level with RCC band at sill level and lintellevel with approved block laying polymer modified adhesive mortar allcomplete as per direction of Engineer-in-Charge. (The payment of RCC bandand reinforcement shall be made for seperately). |
| 27 | OD284347/2025-2026:(Ref. Item No. 10.2) Prefabricated factory made structural steel work riveted, bolted, orwelded in built up sections, trusses, Built-Up/Hot rolled sections/Bracings, and framed work includingsupply and fixing of anchor bolts, base plates, cutting, hoisting, fixing in position and applying a primingcoat of approved The steel structure is to be designed fabricated, supplied, and erected through Pre-Engineering and thedesign shall be approved by the Engineer in charge. Steel section shall confirm to IS 2062:2011 E350, E250or its Equivalent.Details of cost for a truss 7.6 m clear span (weight = 3.95 quintal) MATERIAL:(i) Principal rafter (T-iron):100x100x10 mm @ 15kg/m = 142.50kg+Struts (angles) 40x40x6 mm:2x1.35 = 2.70 m @ 3.5kg/m = 9.45 kgTotal = 151.95 kg +Add wastage @ 5% = 7.60 kgTotal = 159.55 kg. = 1.60 q |
| 28 | 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. |
| 29 | 9.147B.1:Providing and fixing factory made uPVC white colour fixed glazed windows/Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) |
| 30 | 13.4.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand) |
| 31 | 22.5:Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 32 | 22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against anyleakage.For vertical surface two coats @0.70 kg per sqm |
| 33 | 22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against anyleakage.For horizontal surface one coat @1.10 kg per sqm. |
| 34 | 13.80:Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 35 | 13.85.3:Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre |
| 36 | 13.83.2:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 37 | OD376261/2025-2026:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 38 | 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 39 | 10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 40 | 26.65: Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately). |
| 41 | OD378354/2025-2026:Providing & fixing on 1340 x 420mm x 5mm size Stone finished Aluzinc (AZ) sheet having200 gsm AZ coating. Sheet should have polyurethane coating. Weight should be 5.6 Kg/m2. Design as per approved pattern. Complete work including supplying and fixing on roof truss using anti corrosive screws, washers etc. complete as per direction of Departmental Engineer at site. (steel frame work to be done and paid separately) |
| 42 | OD378356/2025-2026:Providing & laying on roof stone finish aluzinc ridge tile of 5 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ). |
| 43 | 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 44 | 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 45 | 11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 46 | OD283121/2025-2026:od102919/2024_2025 :(Ref. Item No. 11.55.1) Providing and laying Lappato finish Granite stone flooring inrequired design and patterns, in linear as well as curvilinear portions of the building all complete as per thearchitectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixedwith pigment of matching shade including rubbing, curing and polishing etc. all complete as specified andas directed by the Engineer-in-Charge.Details of cost for 10 sqm.MATERIAL18mm thick - Lappato finish graniteslab = 10.00 sqm+Add for wastage15% =1.50 sqm, Total 11.50 sqm |
| 47 | 8.2.2.1:Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab upto 0.50 sqm |
| 48 | 8.31:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 49 | OD284336/2025-2026:Providing and fixing PVC eave board of good quality approved by the engineer J or Lhooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drillingfastener and EPDM washer etc. complete: Eave's pieces of 20 cm or nearest size |
| 50 | OD283204/2025-2026:Providing and laying antiskid vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, ofapproved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand),including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x600 mm.Details of cost for 1 sqm.MATERIAL:Vitrified floor tiles 60x60 cm size = 1.00 sqmAdd for wastage & breakage @ 2.5 % =0.025 sqmTotal = 1.025 sqm |
| 51 | OD283236/2025-2026:Providing and fixing Exterior Grade V Board of 12mm thickness and with a density notless than 1200 Kg/ Cu.mtr and shall meet requirements s per IS 14862:2000.All necessary accessoriesrequired for smooth fixation of V Board shall be considered. |
| 52 | OD283235/2025-2026:Providing and fixing of Hollow metal door at all levels from ISO 9001-2000 certifiedManufacturer. The metal doors should be made from high grade galvanised steel stretched level sheet flush, with vision panel, louvers etc. Single /Double leaf to required sizes and approved make shakti met-dor orequivalent which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Doorframe shall be single rebate profile of size 100 x 57 mm made out of 1.20mm minimum thick galvanized steelsheet (18 gauge ). Frames should be mitered and field assembled with self tabs. Door frames should beprepared for suitable hardware as scheduled and should have necessary reinforcement to withstand regularwear and tear. All provision should be mortised, drilled and tapped for receiving the hardware. Rubber doorsilencers should be provided on the striking jamb. All door frames should be provided with backplate andanchor fasteners for installation on a finished plastered masonry wall opening. Once the frame is installed itshould be grouted with cement & sand slurry.Door leaf should be 46mm thick flush double skin door withvision panel of suitable size. Door leaf shall be manufactured from 0.8mm (22 guage) minimum thickgalvanised steel sheet. The internal construction of the door should be rigid with steel stiffeners/ pads andreinforcement. The infill material shall be resin bonded honeycomb core. All doors should be factoryprepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, shaftlocks, flush pull and tower bolt etc. The edges should be interlocked with lock seam. For pair of doorsastragals will be provided as required. 450x750mm Vision lite wherever applicable should be of size fixedwith rubber beeding. The glass should be 4mm clear toughned glass. All doors and frames shall be finishedwith polyurethane aliphatic grade powder coating minimum of 50 microns of approved colour. The door leafand frame shall have passed minimum 500 hours of salt sprey test. Rate should include supply andinstallation of door and hardware as a complete assembly as mentioned in the door and hardware schedule.a). Steel Door TD1 Single leaf 600x1500mm without vision panel with frame on Four sides & hardware set,Hinges 3090 F, 5 Knl, 2 Ball bearing butt hinges size 4\\" x 3\\" x 3mm SS 304, Mortice Shaft Dead lock withAllen key 8681, SSS, Flush Pull Handle 1208, OVAL, SSS |
| 53 | 9.147E.2:Providing and fixing factory made uPVC white colour sliding glazed windowabove 1.50 m in height dimension comprising of uPVC multi-chamberedframe with in-built roller track and sash extruded profiles duly reinforcedwith 1.60 +/- 0.2 mm thick galvanized mild steel section made from rollforming process of required length (shape & size according to uPVC profile),appropriate dimension of uPVC extruded glazing beads, uPVC extrudedinterlocks and uPVC extruded Inline sash adaptor (if required), EPDMgasket, wool pile, zinc alloy (white powder coated) handle on one side ofextreme panel along with zinc plated mild steel multi point locking havingtransmission gear with keeps, zinc alloy (white powder coated) touch lockwith hook (if required for wire mesh panel), stainless steel (SS 304 grade)body with adjustable double nylon rollers (weight bearing capacity to be120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall andnecessary stainless steel screws etc. Profile of frame & sash shall be mitredcut and fusion welded at all corners, including drilling of holes for fixinghardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof siliconsealent over backer rod of required size and of approved quality, allcomplete as per approved drawing & direction of Engineer-in-Charge.(Single / double glass panes, wire mesh and silicon sealent shall be paidseparately).Note: For uPVC frame and sash extruded profiles minus 5% tolerance indimension i.e. in depth & width of profile shall be acceptable.Two track four panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 4.00 sqm upto 8.00 sqm). |
| 54 | 9.7.7.2:Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). |
| 55 | 9.147C.2:Providing and fixing factory made uPVC white colour casement/ Casement cumfixed glazed door comprising of uPVC multi-chambered frame, sash and mullion(where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thickgalvanized mild steel section made from roll forming process of required length(shape & size according to uPVC profile), uPVC extruded glazing beads ofappropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hingesand one handle on each side of panels along with zinc plated mild steel multipoint locking having transmission gear, cylinder with keeps and one side key,G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessarystainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusionwelded at all corners, mullion (if required) shall be also fusion welded includingdrilling of holes for fixing hardware's and drainage of water etc. After fixingframe the gap between frame and adjacent finished wall shall be filled withweather proof silicon sealent over backer rod of required size and of approvedquality, all complete as per approved drawing & direction of Engineer-in-Charge.(Single / double glass panes and silicon sealent shall be paid separately).Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable.Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.(Area of door upto 2.50 sqm) |
| 56 | 9.117.1:Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm |
| 57 | 9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding |
| 58 | 9.118.1:Providing and fixing to existing door frames24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter). |
| 59 | Appendix C-Yard Development works |
| 60 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 61 | 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 62 | OD317077/2025-2026:OD based on 5.33.1.1 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.All work upto plinth level Concrete of M30 grade with minimum cement content of 340 kg /cum |
| 63 | OD317076/2025-2026:OD based on 5.33.2.1 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All work above plinth level upto floor V levelConcrete of M30 grade with minimum cement content of 340 kg /cum |
| 64 | 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 65 | 4.3.2:Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. |
| 66 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 67 | 5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 68 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 69 | 13.45.1:Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm |
| 70 | 13.62.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture . |
| 71 | 16.69:Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge) |
| 72 | 16.78.1:Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 |
| 73 | 16.79:Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge. |
| 74 | 16.91.2:Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 75 | 19.6.3:Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:250 mm dia R.C. C. pipe |
| 76 | 19.7.1.2:Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With Sewer bricks conforming to IS : 4885 |
| 77 | Appendix D-Miscellaneous |
| 78 | 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 79 | 15.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. |
| 80 | 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar |
| 81 | 15.9.2:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar |
| 82 | 15.13.1:Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area 3 sq. metres and below |
| 83 | 15.13.2:Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area beyond 3 sq. metres |
| 84 | 15.19:Dismantling steel work manually / by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per directions of Engineer -in-Charge. |
| 85 | 15.28.2:Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos cement Sheet |
| 86 | OD283679/2025-2026:Providing and fixing Rain water gutter (FRP) of superior quality and of size 25 cm indepth and 20 cm in width including all necessary accessories/ clamps/ joints/stop ends etc. for the smoothinstallation of the same. Colour shall be as per direction of Engineer-in Charge. |
| 87 | 5.28:Providing and fixing in position 12 mm thick bitumen impregnated fibre board conforming to IS: 1838, including cost of primer, sealing compound in expansion joints. |
| 88 | Appendix E- Plumbing |
| 89 | 17.3.1:Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 90 | 17.7.4:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 91 | 17.7.6:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Angle back wash basin size 400x400 mm with single 15 mm C.P. brass pillar tap |
| 92 | 17.4.1:Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 93 | 17.10.2.2:Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x460 mm bowl depth 200 mm |
| 94 | 18.17.1:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore |
| 95 | 18.17.2:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore |
| 96 | 18.18.3:Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore |
| 97 | 18.19.2.1:Providing and fixing gun metal non-return valve of approved quality (screwed end):32 mm nominal boreHorizontal |
| 98 | 18.19.2.2:Providing and fixing gun metal non-return valve of approved quality (screwed end):32 mm nominal boreVertical |
| 99 | 18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 100 | 18.51.1:Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 101 | 18.52.1:Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore |
| 102 | 18.65:Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fittings arrangements, weighing not less than 106 gms. |
| 103 | 50.17.1.3:Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 104 | 50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. |
| 105 | 50.18.8.3.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 12 kgf/cm2 |
| 106 | 50.18.8.4.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2 |
| 107 | 50.18.8.5.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 |
| 108 | 50.18.8.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2 |
| 109 | 50.18.8.7.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2 |
| 110 | 50.18.8.9.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 |
| 111 | 50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow |
| 112 | 50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend |
| 113 | 50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee |
| 114 | 50.18.9.22.8:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 115 | 18.63:Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms |
| 116 | 12.41.2:Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 117 | 18.7.5:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal dia pipes |
| 118 | 18.8.2:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal dia pipes |
| 119 | 18.8.3:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal dia pipes |
| 120 | 18.7.4:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal dia pipes |
| 121 | OD283737/2025-2026:Supply and Labour for Installation of CP Brass Shower Arm, Shower Head, completewith Supporting Accessories, wall chasing, refinishing etc as per building norms. |
| 122 | OD283739/2025-2026:Supply and Labour for Installation of CP Brass Diverter, complete with SupportingAccessories, wall chasing, refinishing etc as per building norms |
| 123 | OD283741/2025-2026:Supply and Labour for Installation of CP Brass Spout, complete with SupportingAccessories, wall chasing, refinishing etc as per building norms |
| 124 | OD283744/2025-2026:Supply and Labour for Sink Pillar cock |
| 125 | OD283749/2025-2026:Supply and Labour for Bottle trap |
| 126 | OD283756/2025-2026:Supply and Labour for Installation of site 15mm dia C.P brass Bib tap/hose connectorwith wall flange including cutting and making good the wall wherever required |
| 127 | OD283760/2025-2026:Supply and Labour for Installing at site UPVC multi inlet traps and outlet connectionsto pipes using solvent cement complete as required for floor drains.(Supreme/Astral or equivalent)\\"Multi Inlet floor trap 110x75x50/40mm. |
| 128 | OD283773/2025-2026:Providing and fixing FRP anaerobic septic tanks of size 1512 Lit volume(2000x900x840 mm or near size) and 5 mm thick for 50 flush/users including all cost of labour,transportationand installation as ordered by Engineer in charge |
| 129 | 19.33:Constructing soak pit 1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. |
| 130 | OD283774/2025-2026:Supplying and installing Concrete ring of 1.20 m diameter with 7.5 cm thickness and 30cm height including sinking the rings in all classes of soil including all cost of conveyance, labour chargestools and plants and all other incidental charges etc complete |
| 131 | OD283781/2025-2026:Providing FRP (Fibre Reinforced Plastic) grating- grills spacing not more than 5cm.,thickness of grill not less than 4cm and grill member thickness not less than 4mm including all cost,conveyance and labour charges etc. complete. |
| 132 | OD283782/2025-2026:Supply and Labour for Installation, testing and commissioning of Manholes,valvechamber, sandtrap etc..including escavation, backfilling, disposel, concretewaterproofing etcupto 1 metre depth all in accordance with the drawing ,specification and relevant standards.Size(as perthe site condition): 60 cm x 60 cm |
| 133 | OD283793/2025-2026:Supply and Labour for Installation ,testing & commisssioningof ISI marked FRP manhole cover and frame of (10 ton withstanding capacity) conforming to the latestrelevant IS specificationsMake:ThermodrainSize: 60 cm x 60 cm |
| 134 | OD283805/2025-2026:Supply & Installation of Grab Bar |
| 135 | OD283806/2025-2026:Supply and Installation of Towel Ring |
| 136 | OD283849/2025-2026:Supply and Installation of Robe Hook |
| 137 | OD283817/2025-2026:Supply and Installation of Towel Rack |
| 138 | OD283818/2025-2026:Supply and Installation of Hand Dryer |
| 139 | OD283824/2025-2026:Supply and Installation of Tissue Holder |
| 140 | OD283829/2025-2026:Supply and Labour for Installation of water level float switch system for water levelcontrolling |
| 141 | OD283858/2025-2026:Providing , supply and fixing Open well submersible pump-1.5HP including all fittingsand accessories of approved IS make etc complete as per design and drawings |
| 142 | OD283869/2025-2026:Providing , supply and fixing Borewell Submersible Pump-1.5HP water cooling with 6mm dia ss rop including all fittings and accessories of approved IS make etc complete as per design and drawings |
| 143 | OD283870/2025-2026:Supply and installation of Water heater with 10 Litre tank |
| 144 | OD283893/2025-2026:Fabrication and installation of Fire water tank using structural steel work in singlesection, fixed with or without connecting plate, including cutting, hoisting, fixing in position all complete. |
| 145 | 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 146 | Appendix E- Fire Fighting |
| 147 | OD283897/2025-2026:Supply, installation, testing and commissioning of Pressure Gauge with requiredrange/capacity |
| 148 | OD283919/2025-2026:Supply, erection, testing and Commissioning of Motor control panel for Terracepump incorporating automatic direct online starter for fire pumps switch gear ratedfor the motor HP. The control panel mounting shall include necessary indicationlamps for the RYB phase showing the power supply conditions ammeter withclear indications or motor full load current, voltmeter with selector switch etc. Thepanel shall duily painted with proper anti-corrosive lacquer and is of wall mounted type with all accessoriesas required etc. complete. |
| 149 | OD283923/2025-2026:Supply, Installation, Testing and Commissioning Electrically driven MonoblockTerrace pump of capacity 900 LPM with all the necessary accessories operatingon 3 Ph. 50 Hz. 415 V AC supply including foundation, bolts etc. complete, ThePump set shall be of 5 HP. (Foundation required shall be provided by the client). |
| 150 | OD283926/2025-2026:Supply, installation, testing and commissioning of Pressure Switch for automaticoperation. |
| 151 | OD283932/2025-2026:Under Ground Piping: Supply, erection, testing and commissioning of heavy dutyM.S 'C' class Pipes confirming to IS 3589 / IS :1239 part - I with malleablespecials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc.Including cutting, Welding, laying under ground, by using suitable supports,andwrapping with polymer corrossion protection tape confirming to IS 10221 withproper overlapping, trimming etc complete. etc. complete (The Rate forexcavation shall be extra as applicable) : 100mm dia |
| 152 | OD283935/2025-2026:Above Ground Piping: Supply, erection, testing and commissioning of heavy dutyM.S 'C' class Pipes confirming to IS 3589/ IS :1239 part - I with malleable specialsconfirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Includingcutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipeshall be painted with one coat of primer and two coats of synthetic enamel paint ofapproved colour / shade. (Core cutting in walls/beams/columns for laying pipesshall be provided by client, if necessary)80mm dia |
| 153 | OD283939/2025-2026:Above Ground Piping: Supply, erection, testing and commissioning of heavy dutyM.S 'C' class Pipes confirming to IS 3589/ IS :1239 part - I with malleable specialsconfirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Includingcutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipeshall be painted with one coat of primer and two coats of synthetic enamel paint ofapproved colour / shade. (Core cutting in walls/beams/columns for laying pipesshall be provided by client, if necessary) 100 mm dia |
| 154 | OD283942/2025-2026:Supplying, Installing, testing and commissioning CI Butterfly valve slim sealstandared lever operated type confirming to IS 13095 with required flanges, nuts,bolts etc. complete. |
| 155 | OD283945/2025-2026:Supply, installation, testing and commissioning of C.I. Non-Return Valve slim sealtype with required flanges, nuts & bolts, gasket etc. complete |
| 156 | OD283947/2025-2026:Supply, installation, testing and commissioning of instantaneous pattern SS SingleHeaded Hydrant valve of 63mm Dia, oblique type, instantaneous hose couplingadaptor complete with PVC blank cap etc. |
| 157 | OD283949/2025-2026:Supply and placed in position of SS Branch Pipe, 63mm female instantaneousinlet, male threaded outlet, complete with hexagonal base nozzle |
| 158 | OD284240/2025-2026:Supply and placed in position of Controlled Percolated Hose conforming to IS:636, 63mm dia, 15 Mtrs length with SS 63 mm pair of male and female couplingsetc. |
| 159 | OD284241/2025-2026:Supply, installation, testing and commissioning of Hydraulic Hose Reel drumcompleted with swinging type drum with 19mm dia thermoplast braided hose of30M. length and Shut off nozzle, with necessery fittings etc. complete |
| 160 | OD284242/2025-2026:Supplying, installing, testing and commissioning of Cast iron Ball valves withfittings of screwed end type. 25mm dia |
| 161 | OD284243/2025-2026:Supply, installation, testing and commissioning of Single Door Hose Cabinet toaccommodate one piece of hose pipe along with one pair of male and femalecoupling and one branch pipe. The cabinet is made of 20swg M.S Sheet, glassfronted with hinged door and lock. The cabinet is spray painted to scarlet redcolor. |
| 162 | OD284250/2025-2026:Supply, installation, testing and commissioning of single acting Air Release Valvewith screwed inlet 20mm dia etc |
| 163 | OD284251/2025-2026:Supply, installation, testing and commissioning of Fire Brigade Inlet connectionwith 2 nos of 63 mm dia. built - in Gun metal Non- return valves instantaneouscoupling type arranged on 100 mm dia.etc. Pipe manifold shall be connected todown comer pipe. |
| 164 | OD284253/2025-2026:Supplying and installing of in positionthe following type of sign boards madeout of 3mm thick \\"Opaque\\" PVC foamboard with computer cut, PVC Nonreflectiveself adhesive vinyl paintedfoam board, complete with mirrorfasteners. |
| 165 | OD284254/2025-2026:Supplying and installing of in position the following type of sign boards made outof 3mm thick \\"Opaque\\" PVC foam board with computer cut, PVC Non-reflectiveself adhesive vinyl painted foam board, complete with mirror fasteners. FIRE EXIT |
| 166 | OD284256/2025-2026:Supplying and installing of in positionthe following type of sign boards madeout of 3mm thick \\"Opaque\\" PVC foamboard with computer cut, PVC Nonreflectiveself adhesive vinyle paintedfoam board, complete with mirrorfasteners. |
| 167 | OD284261/2025-2026:Supply, installing, testing and commissioning of Micro processor based Main Firealarm control panel of 4 zones capacity, with visual LED indications for fire / faultalarms, signals and should have stage alarm facility with maintenance free batteryback up for 24 hours normal operation and 15 minutes alarm operation. The panelshall be fabricated by M.S. sheet and powder coated both inside & out side, doorshall be glass fronted type with locking arrangement, as per specification |
| 168 | OD284264/2025-2026:Supply, Installation, testing and commissioning of Manual Call Point break glasstype as per standard specification |
| 169 | OD284267/2025-2026:Supply, installation, testing and commissioning of Electronic dual tone Hooter(Sounder) as per standard specification |
| 170 | OD284268/2025-2026:Supplying and laying of P.V.C conduit with all necessary fittings. Etc |
| 171 | OD284269/2025-2026:Supplying and laying of 1C x 1 Sq.mm cross section PVC insulated copperwires. |
| 172 | OD284270/2025-2026:Supplying, and fixing of ABC type fireextinguisher of 4Kgs. Capacity, with initialfilling in brand new cylinder with powdercoated finish, fitted with Gun metal union,discharge hose, wall mounting bracketetc. complete |
| 173 | OD284272/2025-2026:Supplying and installing in positionlaminated sheet of \\"Fire EvacuationPlan\\". Providing wall mounting displayboard with double side 3mm thickimported acrylic sheet & glowsheet withSS Studs Digital color print onTraceperacy Sheets : Size 24\\"X18\\" |
| 174 | OD284321/2025-2026:Supplying and installing in position Exit LED Signage (Arrow) - green led lightningwith Battery backup for 3 hrs |
| 175 | OD284326/2025-2026:Supplying and installing in position FIREEXTINGUSHERS Signages ( Acrylic +Self Illumiated with LED Lights nobackup, Triangular Type) Size15\\"X4\\" |
| 176 | OD284325/2025-2026:Supplying and installing in position SafeAssemble Point with 8 feet Size2\\"X1\\" |
| 177 | OD284324/2025-2026:Supplying and installing in position Way to safe assemble point with 8 feet Size2\\"X1\\" |
| 178 | OD284323/2025-2026:Supplying and installing in position Fire Order Board 3"X2" |
| 179 | OD284322/2025-2026:Supplying and installing in position STAIRCASE SIGNAGES Acrylic + SelfIlluminated Size 16\\"X6\\" |
| 180 | Conduit laying and associated works |
| 181 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 182 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 183 | 1.21.5:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.50 mm |
| 184 | Wiring and accessories |
| 185 | 1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 186 | 1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 187 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A |
| 188 | 1.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B |
| 189 | 1.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 190 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 191 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 192 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 193 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 194 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 195 | 1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 196 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 197 | 1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 198 | 1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 199 | 2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 200 | 90.6.6.2:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.2.50 sq mm |
| 201 | 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator |
| 202 | 90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator |
| 203 | 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 204 | 90.14.28.12:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,DPMCB for single phase 1.5 HP submersible motor pumps (DOL) |
| 205 | 90.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator |
| 206 | 1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable |
| 207 | OD284786/2025-2026: Supply and installation of RJ45 socket with shutter |
| 208 | 90.6.9.2:Supplying & Drawing unarmored PVC insulated and & PVC sheathed copper conductor Telephone Pair Cable conforming to ITD specification for indoor application through the existing conduit2 pair |
| 209 | 1.24.6:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 210 | 1.24.7:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet |
| 211 | Fittings and installations |
| 212 | 90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture |
| 213 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 214 | 1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 215 | 1.49:Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required. |
| 216 | 1.51:Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required |
| 217 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. |
| 218 | 90.4.10:Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan. |
| 219 | 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 220 | OD284792/2025-2026:Supply, installation, and testing of mirror light fitting of the following specification: 10W LED Batten, 2 feet (similar to Wipro Garnet) Colour temp: Cool Day Light (6500K) with 1000 lm. (Make:Philips/Wipro/Kesselec) |
| 221 | OD284788/2025-2026:Supply and fixing of bulk-head light fittings of the reputed company make, with clear/frosted glass cover, 10-Watt LED Bulkhead, Lumen : 850 Lm, Power : 10 W, Color Temperature : 6500 K, IP-65 rating, similar to Bajaj Ivora 10-Watt LED Bulkhead. (Make: Bajaj/Philips/Havells/wipro/Crompton |
| 222 | OD284805/2025-2026:Supply of 250 mm sweep Light Duty Exhaust fan in plastic body with self-opening lowers working on 230V single phase A/C |
| 223 | OD284789/2025-2026:Supply, installation, testing, and commissioning of the following sweep ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 3-core flexible Copper round cable, etc. as required. (a) 1200 mm sweep ceiling fan with stepped-type electronic fan regulator, brand approved by the engineer in charge |
| 224 | OD284787/2025-2026:Supply of vertical open well submersible pump having a capacity of 1.5 hp, 9-stage |
| 225 | OD284803/2025-2026:Supply and fixing 30 amps. TPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure |
| 226 | OD321073/2025-2026:Supply installation testing and commissioning of 25 KVA Diesel Generator set acoustic enclosure (Kirloskar/Cummins)with standard Generator Panel,silencer,Heat resistant paint coating,Thermal insulation on exhaust pipe up to 3m and extending the exhaust using C class MS pipe above the existing building including getting approval from Electrical inspectorate. |
| 227 | OD284797/2025-2026:Supply of shock treatment chart in glass with frame |
| 228 | OD284806/2025-2026:Supplying and fixing of Danger 415 V, 250 X 200 mm Enameled danger plates |
| 229 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 230 | OD284800/2025-2026:Supply and installation of 9w LED bulb having 900lm or higher (Make:Philips/Wipro/Kesselec or any equivalent spec PWD/KSCADC approved make) |
| 231 | OD284794/2025-2026:Supply, installation, and testing of 17W wall light fitting of the following specification: 17W LED wall light, Colour temp: 3000K-6500K (Similar to Philips Ultron slim 17w). (Make:Philips/Wipro/Kesselec or equivalent spec PWD/KSCADC approved make ) |
| 232 | OD284795/2025-2026:Supply, installation, testing, and commissioning of 10W Vertical decorative Wall Light(wall washer light/Up and down decorative Outdoor Wall light) (Similar to Philips Lucent 10w) Make:Philips/Wipro/Kesselec or equivalent spec PWD/KSCADC approved make ) |
| 233 | OD284802/2025-2026:Supply, installation, and commissioning of 3kva UPS Single phase in and Single phase out. with indoor (IP20) Input pf >0.99, double conversion technology with input voltage range 140-280 @ full load, 50Hz, It shall be 100% generator compatible, and isolation transformer built-in at input side. with Efficiency > 87% and output power factor unity (3kVA= 3kW), and including all accessories etc. as required. The acoustic noise at 1m of the system should be <65dB.The system shall comply to IEC /EN 62040-1 safety, IEC/EN62040- 2, Electromagnetic Compatibility IEC/EN 62040-3 performance, and relevant IS standards.The system shall be true online double - conversion DSP based UPS system, and UPS shall bewith automatic bypass built-in. The system shall have IGBT rectifier and inverter. Includingrack and interconnecting cables etc.... warranty certificates for 3 years for UPS and batteries and transformer should be from UPS OEM. UPS. (Make: Numeric-LEGRAND/ABB/GE/APC or equivalent spec approved) along with SITC of BATTERY SMF 12v 65ahx 6 nos Exide/Quanta/Amaron Make, Back Up time 1 hours at full load. |
| 234 | DB and accessories |
| 235 | 90.11.1.19:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 236 | 90.14.10.3:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL |
| 237 | 90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) |
| 238 | 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door |
| 239 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 240 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 241 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 242 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 243 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 244 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 245 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 246 | 2.25:Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. |
| 247 | Cabling and accessories |
| 248 | 90.12.6.39:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 6 sq mm |
| 249 | 90.12.6.41:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 16 sq mm |
| 250 | 90.12.5.29:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 50 sq mm |
| 251 | 90.12.5.41:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm |
| 252 | 90.12.6.29:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 50 sq mm |
| 253 | 90.12.7.29:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp |
| 254 | 90.12.5.30:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 70 sq mm |
| 255 | 90.12.7.39:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp |
| 256 | 90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp |
| 257 | OD284781/2025-2026:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 6 sq. mm (19mm) |
| 258 | 9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 259 | 9.3.20:Supplying and making straight through joint with cast resin compound including ferrules andother jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 70 sq. mm |
| 260 | 90.12.5.12:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 4 sq mm |
| 261 | 90.12.7.12:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 4 sq mm with factory made clamp |
| 262 | OD284782/2025-2026:Supply and installation of 4 sq mm to 16 sq mm. 60 mm long x 12 mm wide x 1 mm thick Copper earthing clips for single compression glands and giving all connections. |
| 263 | Earthing and associated works |
| 264 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 265 | 5.20:Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. |
| 266 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 267 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 268 | 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) |
| 269 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 270 | OD284785/2025-2026:Supply and fixing of copper earthing test joint including necessary hole drilling and provision to connect earthing conductors. 20mm x 3 mm Cu tape completing with all respects as required. |
| 271 | 90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) |
| 272 | 90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) |
| 273 | 90.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip |
| 274 | Safety equipment |
| 275 | OD284808/2025-2026:Supplying and fixing Fire Extinguisher-ABC 5 Kg Type |
| 276 | OD284809/2025-2026:Supplying and fixing Fire Extinguisher-CO2 4.5 Kg Type |
| 277 | OD284807/2025-2026:Supplying and fixing 2.00 mm thick, 3.3 kV, Synthetic elastromeric fire retardant insulating sheet |
| 278 | OD284810/2025-2026:Supply and fixing of 2 Nos fire buckets along with a stand painted with enamel paint of red colour |
| 279 | LA and associated works |
| 280 | OD284816/2025-2026:Providing and fixing of IEC 62561 tested suitable cross connector, parallel connector, expansion piece with connector (For equalizing temperature-related length changes) to route horizontal conductor /mesh formation made of stainless steel. Tested from a laboratory accredited by UL, KEMA or VDE |
| 281 | OD284814/2025-2026:8mm solid aluminum round conductor: For sheet ridge position conductor routing application: Meets the technical specification according to . Meets the requirement of IS/IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5) With 50 sq. mm cross-sectional area installed with Ridge conductor holder with tensioning spring - Stainless steel Conductor holder <br>Conductor holder @ 1 meter distance. Tested from a laboratory accredited by UL, KEMA, or VDE |
| 282 | OD284815/2025-2026:Application: Polycarbonate Sheet 8mm solid aluminum round conductor: For concrete building Polycarbonate Sheet application: Meets the technical specification according to .<br>Meets the requirement of IS/IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5) With 50 sq.mm cross-sectional area installed with Polyamide Conductor holder with bonding base.With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistance from -35 to +90 degree Celsius were tested. Conductor holder @1 meter distance Bonding Base: With threaded stem M8. For Mounting conductor supports with M8 female thread. For bonding to concrete, steel, or brickwork. Tested from a laboratory accredited by UL, KEMA, or VDE |
| 283 | OD284813/2025-2026:Supply, installation, testing, and commissioning of combination arrester of the following spec:Pole version 3+N/PE, Combination arrester, lightning and surge arrester type 1+2, (Similar to OBO Combination arrester V25, 3-pole + NPE 385 V) Make:OBO or equivalent spec PWD/KSCADC approved make ) |
| 284 | LT panel board and energy meter chamber |
| 285 | OD284812/2025-2026:METERING BOARD WITH ISOLATIONSupply and labour charges for installation, testing &commissioning of 125A MV cubical panel board, dust & vermin tight proof, powder coated front opening type, cable bottom entry type, wall mounted using nuts & bolts, stencilling all identification, etc.. Confirming to IS1863, IE rules Incomer 1125A 4P 25KA Thermomagnetic based MCCB with a variable setting with all isolation duty -1No with 3 nos.100A porcelain cut-out fuse and provision for CT metering. -1No 40A 4P MCB with provision for KWH metering-1 nos(solar) All MCCBs are with rotary operating handles for door interlock.Busbar :125A TPN Al/Cu busbar Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy