| 1 | PART - I : Maintenance of 144 nos of street lights at various wards |
| 2 | 1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm |
| 3 | OD536786/2024-2025:Supply, conveyance, testing and dismantling non burning and damaged street lights and refitting new street lights with censor etc. and giving connections with suitable accessories as required including labour. |
| 4 | OD536785/2024-2025:Application fee for remitting KSE Board |
| 5 | PART - II : Maintenance of Min High Mast lights at various wards - 19 nos. |
| 6 | 90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 7 | OD536801/2024-2025:Supply and installation of dust and vermin proof, wall mounting, Sintex meter box of size 505x24x145mm suitable for fixing KSEB meter, fuse unit etc., hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit. (GSMB-5628) |
| 8 | OD536883/2024-2025:Supply and fixing 32A, 415V, 2 way neutral link mounted on DMC/SMC base in the existing meter board and giving connection etc. |
| 9 | OD536884/2024-2025:Supply and fixing 32A, backlite fuse base with HRC fuse link in the existing meter board and giving connection etc. |
| 10 | 2.14.3:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 11 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 12 | 1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm |
| 13 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door Please Enable Macros to View BoQ information |