| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil |
| 3 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 4 | DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonrywith good quality blasted rubble including packing to compactness to lines and levelscost and conveyance of all materials labour charges etc. complete as per direction ofDepartmental officers at site |
| 5 | Random rubble masonry with hard stone in superstructure above plinth level and uptofloor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceilinglevel and the like.Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 6 | Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete |
| 7 | Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers |
| 8 | Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform |
| 9 | Centering and shuttering including strutting, etc. and removal of form for:Stairs,(excluding landings ) except spiral - staircases) |
| 10 | Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (ZoneIII) derived from natural sources: 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 12 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more |
| 13 | Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cmor nearest available size confirming to IS 2185 Part I of 1979 for super structure up tofloor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etccomplete |
| 14 | Providing and laying cement concrete in retaining walls, return walls, walls ( anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks,plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the costof centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III)derived from natural sources : 6 gradedstone aggregate 20 mm nominal size derived from natural sources) |
| 15 | 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). |
| 16 | 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1cement : 3 fine sand) |
| 17 | 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) |
| 18 | Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:Water thinnable cement primer |
| 19 | Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm) |
| 20 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 800x 800 mm |
| 21 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm ormore (thickness to be specified by the manufacturer), of 1st quality conforming to IS:15622, of approved make in colours White, Ivory, Grey, fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 cement : 4 Coarse sand), including grouting the jointswith white cement and matching pigments etc., complete. |
| 22 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shade complete |
| 23 | Providing and fixing finished brass hard drawn hooks and eyes:100 mm |
| 24 | Providing and fixing finished brass hard drawn hooks and eyes:300 mm |
| 25 | Providing and fixing finished brass hard drawn hooks and eyes:200 mm |
| 26 | Providing and fixing chromium plated brass handles with necessary screws etc.complete:100 mm |
| 27 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainless steeldash fasteners, stainless steel bolts etc., of required size on the top of the floor or theside of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 28 | Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron |
| 29 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panellingfixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofEngineer - in- Charge.Pre-laminated particle board with decorative lamination on oneside and balancing lamination on other side |
| 30 | For shutters of doors, windows & ventilators including providing and fixing hinges /pivots and making provision for fixing of fittings wherever required including thecost of EPDM rubber/ neoprene gasket required (Fittings shall be paid forseparately)Anodised aluminium ( anodised transparent or dyed to required shadeaccording to IS : 1868, Minimum anodic coating of grade AC 15) |
| 31 | Providing and fixing bright finished 100 mm mortice lock with 6 levers without pairof handles of approved quality for aluminium door, with necessary screws etccomplete as per direction of Engineer- in- charge. |
| 32 | Providing and fixing Brass100 mm mortice latch and lock with 6 levers without pairof handles ( best make of approved quality ) for aluminum doors including necessarycutting and making good etc. complete |
| 33 | Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness (weight not less than 10kg/sqm) |
| 34 | Providing and fixing sliding arrangement in racks/ cupboards/cabinets shutter by withstainless steel rollers to run inside C or E aluminium channel section ( The paymentof C or E channel shall be made separately |
| 35 | Providing and fixing flat pressed three layer particle or graded plain wood boardmedium density exterior grade (Grade I) FPT-1, conforming and marked to IS : 3087to frame, backing or studding with screws etc. complete (Frames, backing or studdingto be paid separately):18 mm thick |
| 36 | Providing and fixing magnetic catcher of approved quality in cupboard/ward robeshutters, including fixing with necessary screws etc. complete.Triple strip verticaltype) |
| 37 | Providing and fixing magnetic catcher of approved quality in cupboard/ward robeshutters, including fixing with necessary screws etc. complete.Double strip(horizontal type |
| 38 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wallthickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred atcorners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. squaretube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. squaretube of 19 gauge, EPDM rubber gasket weather seal to be provided through out theframe. The door fame to be fixed to the wall using M.S. screws of 65/100 mm size,complete as per manufacturer's specification and direction of Engineer-in Charge. |
| 39 | Providing and fixing factory made panel PVC door shutter consisting of frame madeout of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers ofapproved make and manufacture. M.S. frame covered with 5 mm thick heat mouldedPVC 'C' channel of size 30 mm thickness, 70 mm width out of whicj 50 mm shall beflat and 20 mm shall be tapered in 45 degree angle on both side forming styles and5mm thick, 95 mm wide PVC sheet out of which75 mm shall be tapered in 45 degreeon th inner side to form top and bottom rail and 115 mm wide PVC sheet out ofwhich 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail.Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mmx2)thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottomrail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. framewelded /sealed to the styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm widePVC sheet beading on inner side, and joined together with solvent cement adhesive.An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior sideof the 'C' Channel using PVC solvent adhesive etc. complete as per direction ofEngineer -in-charge, manufacture's specification & drawing.30 mm thick plain PVCdoor shutters |
| 40 | Providing and fixing special quality chromium plated brass cupboard locks with sixlevers of approved quality including necessary screws etc. complete.Size 75 mm |
| 41 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:100 mm |
| 42 | providing and fixing powder coated telescopic drawer channels 300 mm long withnecessary screws etc. complete as per directions of Engineer -in-charge |
| 43 | Providing and fixing casement handle made of zinc alloyed (white powder coated) foruPVC casement window with necessary screws etc. complete |
| 44 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade with necessary screws etc. complete:100x75x4 mm |
| 45 | Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:200x10 mm |
| 46 | Centering and shuttering including strutting, propping etc. and removal of form workfor:Foundations, footings, bases for columns |
| 47 | Providing at all heights, levels and locations Aluminium profile industrial troughedsheet of Alloy 31500/31000/40800, conforming to IS 1254, IS 737, IS 2676. Thesheet shall be fixed using self drilling/self tapping SS screws of size 5.5x65 mm withEPDM seal complete upto required pitch in horizontal, vertical or curved surfaces i/ccutting to size and shape where required as per specifications, detail drawings anddirection of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge,labour, scaffolding, machinery for fixing and approved sealent where required etc. butexcluding the cost of purlins, rafters and trusses.0.40 mm thick, the profile detailwidth 1044/920 mm, cover width 1000/875 mm. |
| 48 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarsesand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 49 | Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.)trusses etc., including cutting, hoisting,fixing in position and applying a priming coatof approved steel primer, including welding and bolted with special shaped washersetc. complete |
| 50 | Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paidfor separately).Second class teak wood |
| 51 | Providing and fixing panelled or panelled and glazed shutters for shutters for doors,windows and clerestory windows, including ISI marked M.S. pressed butt hingesbright finished of required size with necessery screws, excluding panelling which willbe paid for separately, all complete as per direction of Engineer - in-charge.Second class teak wood35 mm thick shutters |
| 52 | Applying priming coat:With ready mixed pink or Grey primer of approved brand andmanufacture on wood work (hard and soft wood) |
| 53 | Painting with synthetic enamel paint of approved brand and manufacture of requiredcolour to give an even shade:Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand and manufacture . |
| 54 | Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturer's specifications including appropriate priming coat,preparation of surface, etc. complete.On steel work |
| 55 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mmnominal size) |
| 56 | Providing and laying 60 mm thick factory made cement concrete interlocking paverblock of M - 30 grade made by block making machine with strong vibratorycompaction, of approved size, design & shape, laid in required colour andpattern over and including 50 mm thick compacted bed of coarse sand, filling thejoints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 57 | Providing and fixing a plaque in marble/granite slab with all cost of materialconveyance and labour charges etc complete |
| 58 | SANITARY AND PLUMBING |
| 59 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore |
| 60 | Providing and fixing brass stop cock of approved quality :15 mm nominal bore |
| 61 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank |
| 62 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Washbasin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap |
| 63 | Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102mm, height of 75 mm with concealed fittings arrangements, weighing not less than106 gms. |
| 64 | Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC.waste fittings complete.Semi rigid pipe32 mm dia |
| 65 | Providing and fixing white vitreous china pedestal type water closet (European type)with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flushbend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement withspecials of standard make and mosquito proof coupling of approved municipal designcomplete, including painting of fittings and brackets, cutting and making good thewalls and floors wherever required :W.c. pan with ISI marked black solid plastic seatand lid |
| 66 | Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make )including cost of materials and labour charges etc complete as per the direction of siteEngineer-in-charge |
| 67 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work,including cutting chased and making good the wall etc. 20 mm pipe12 Kgf/cm2 |
| 68 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 25 mmdia 10 Kgf/cm2- External work - Exposed on wall |
| 69 | Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 mspacing. This includes jointing of pipes with one step PVC solvent cement and testingof joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2-External work - exposed on wall |
| 70 | Providing and fixing PVC pipes, fittings including fixing the pipe with claps at 1.00metre spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 20 mmdia 12Kgf/cm2 - Internal work - Exposed on wall |
| 71 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 25 mm pipe12 kgf/cm2 |
| 72 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer- in- Charge 25 mmdia 12 Kgf/cm2 - Internal work - Exposed on wall |
| 73 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 10 Kfg/cm - Internal work- Exposed on wall |
| 74 | Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of Joints complete as per directionof engineer in charge.110 mm dia 6Kgf/cm2 |
| 75 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Elbow |
| 76 | Supplying and installing ready made PVC Septic tank including the cost of carriage,trenching, placing at the level below ground level as specified as per the direction ofengineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparationof bed shall be paid separately) 4. 35 to 50 flush capacity |
| 77 | Constructing soak pit 1.20x1.20 m filled with brickbats including S.W. drain pipe 100mm diameter and 1.20 m long complete as per standard design |
| 78 | Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of joints complete as per direction ofEngineer in Charge.32 mm dia 10.Kgf/cm2 |
| 79 | Providing and fixing PVC pipes includings of pipes with one step PVC solventcement, trenching refilling & testing of joints complete as per direction of Engineer inCharge. 63 mm dia 6Kgf/cm2 |
| 80 | Providing and fixing PVC pipes includings of pipes with one step PVC solventcement, trenching and refilling & testing of joints complete as per direction ofEngineer in Charge. 75 mm dia 4 Kgf/cm2 |
| 81 | Providing and fixing PVC pipes includes joints of pipes with one step PVC solventcement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 |
| 82 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia Elbow |
| 83 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -63 dia 45 degree Elbow |
| 84 | Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow |
| 85 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement-110 mm dia Door Elbow |
| 86 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 110 mm dia Bend |
| 87 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipesincluding jointing with PVC solvent cement 110x110x110 mm dia Tee |
| 88 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110x110x110 mm dia Door tee |
| 89 | Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes,including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 90 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement -110 mm dia End Cap |
| 91 | Providing and fixing PVC moulded fittings/accessories for Rigid PVCpipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling |
| 92 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110x75 mm dia Reducer |
| 93 | ELECTRIFICATION |
| 94 | Supply and wiring points according to IS 732-1989 using rigid PVC conduit ofminimum size 20 mm with specials conforming to IS 9537 part III 1983 and withsuitable size specials conforming to IS 3419-1988, fixing the conduit using metalsaddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mmFRLS PVC insulated stranded single core copper conductor cable 650V grade,including providing switch board main and continuous earthing with No.14 SWGbare copper,required quantity of copper earth socket, brass bolt and nut crimping/soldering etc complete with suitable size modular type metal switch boxes, modulartype front plates (white) etc. up to and including 6A modular type SP switches andmaking good the surface of wall, colour washing etc. complete. All the terminationsin the switch boards and DB's shall be tinned and the wires shall be drawn and fixedalong the periphery of the box using suitable ties, tie mounts etc as required. (RoHScompliant modular accessories).Single Control light point with 6A, plate ceiling rose- Short point |
| 95 | Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mmFRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modulartype front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Twin Control light point with 6A, plate ceiling rose - Short point |
| 96 | Supply and wiring points according to IS 732-1989 using rigid PVC conduit ofminimum size 20 mm with specials conforming to IS 9537 part III 1983 and withsuitable size specials conforming to IS 3419-1988, fixing the conduit using metalsaddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade,including providing switch board main and continuous earthing with No.14 SWGbare copper,required quantity of copper earth socket, brass bolt and nut crimping/soldering etc complete with suitable size modular type metal switch boxes, modulartype front plates (white) etc. up to and including 6A modular type SP switches andmaking good the surface of wall, colour washing etc. complete. All the terminationsin the switch boards and DB's shall be tinned and the wires shall be drawn and fixedalong the periphery of the box using suitable ties, tie mounts etc as required. (RoHScompliant modular accessories).Single control light point without ceiling rose - Shortpoint |
| 97 | Supply and wiring points according to IS 732-1989 using rigid PVC conduit ofminimum size 20 mm with specials conforming to IS 9537 part III 1983 and withsuitable size specials conforming to IS 3419-1988, fixing the conduit using metalsaddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mmFRLS PVC insulated stranded single core copper conductor cable 650V grade,including providing switch board main and continuous earthing with No.14 SWGbare copper,required quantity of copper earth socket, brass boltand nut crimping/soldering etc complete with suitable size modular type metal switch boxes, modulartype front plates (white) etc. up to and including 6A modular type SP switches andmaking good the surface of wall, colour washing etc. complete. All the terminationsin the switch boards and DB's shall be tinned and the wires shall be drawn and fixedalong the periphery of the box using suitable ties, tie mounts etc as required. (RoHScompliant modular accessories).Single control ceiling fan point with 6 A, 3 plateceiling rose & with socket size stepped electronic regulator. - Short point |
| 98 | Supply and wiring points according to IS 732-1989 using rigid PVC conduit ofminimum size 20 mm with specials conforming to IS 9537 part III 1983 and withsuitable size specials conforming to IS 3419-1988, fixing the conduit using metalsaddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mmFRLS PVC insulated stranded single core copper conductor cable 650V grade,including providing switch board main and continuous earthing with No.14 SWGbare copper,required quantity of copper earth socket, brass bolt and nut crimping/soldering etc complete with suitable size modular type metal switch boxes, modulartype front plates (white) etc. up to and including 6A modular type SP switches andmaking good the surface of wall, colour washing etc. complete. All the terminationsin the switch boards and DB's shall be tinned and the wires shall be drawn and fixedalong the periphery of the box using suitable ties, tie mounts etc as required. (RoHScompliant modular accessories).Combined plug point with 6 A, 5 pin plug socketcontrolled by 6 A, switch in the same switch board as that of light points |
| 99 | Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and withsuitable size specials conforming to IS 3419-1988, fixing the conduit using metalsaddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mmFRLS PVC insulated stranded single core copper conductor cable 650V grade,including providing switch board main and continuous earthing with No.14 SWGbare copper,required quantity of copper earth socket, brass bolt and nut crimping/soldering etc complete with suitable size modular type metal switch boxes, modulartype front plates (white) etc. up to and including 6A modular type SP switches andmaking good the surface of wall, colour washing etc. complete. All the terminationsin the switch boards and DB's shall be tinned and the wires shall be drawn and fixedalong the periphery of the box using suitable ties, tie mounts etc as required. (RoHScompliant modular accessories).Independent plug - Short point |
| 100 | Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 101 | Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bentto shape / cut and welded to shape and fixing the same to wall / parapet using clampsas noted along with each size, painting with 2 coats of synthetic enamel paint over acoat of zinc chromate primer, making good the damages, colour washing etc asrequired.32 mm dia with HG company fabricated clamps |
| 102 | Supply Conveyance, installation, testing and commissioning of 36/40W LED streetlight output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chipmake Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internalsurge protection up to 8 KV,and Aluminium pressure die-cast Powder coatedhousing,acrylic cover complete with THD less than 10%, power factor greater than0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Drivercompartment should be seperatly accessible for maintenance (LM 79&80 certificatesfrom NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 103 | Supply & installation of light fittings on TW round blockSupply, conveyance installation testing and commissioning the light fittings offollowing types made of CRCA with 0.5mm thickness complete with all accessoriesand lamps etc. directly on wall or ceiling with PVC round block neatly painted to suitthe fitting and giving connection with required length of 16/0.20mm 3 core copperconductor flex wire conforming to relevant ISS and giving connections asrequired.1200 mm 1X20W LED Lamp with box type fixture |
| 104 | Supply & installation of light fittings on 'C/U' shaped flat iron bracketSupply, conveyance, installation, testing and commissioning the light fittings offollowing types made from 0.5mm CRCA sheet complete with all accessories andlamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat,painting the flat iron bracket and giving connections with required length of16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS orextending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture |
| 105 | Charges for cutting holes suitable for accommodating exhaust fans above 305mmsweep and up to 450mm sweep including plastering colour washing etc. as required. |
| 106 | Supply and installation of suitable size MS rod type fan clamp in the RCC slab as perIS 732 as required |
| 107 | Supply, Installation, testing and commissioning of ceiling fan of following sizesincluding wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mmFRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cubmeter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper windingsuitable for 230V/240V single phase AC supply |
| 108 | Supply and fixing of following sizes of light gauge PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required20 mm |
| 109 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x2.5 sq. mm |
| 110 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x4 sq. mm |
| 111 | Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in the existing RCC/HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm |
| 112 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp |
| 113 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 25 sq mm with factory made clamp |
| 114 | Supplying, laying and jointing of the following sizes of double wall corrugated(DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanicalprotection to underground power cables with all required accessories in ground in theexisting trench50/38 mm or nearest size |
| 115 | Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.4 X 16 sq. mm (28mm) |
| 116 | Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.4 X 25 sq. mm (28mm) |
| 117 | Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch |
| 118 | Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.6pin 15/16 amp socket outlet |
| 119 | Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 120 | Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth busand DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good thedamages, colour washing etc. as required4 way (8+12) - three phase double cover (IP42/43) |
| 121 | Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door |
| 122 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 123 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 124 | Supplying and fixing single pole blanking plate in the existing MCB DB completeetc. as required |
| 125 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps |
| 126 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.63amps |
| 127 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 128 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired. |
| 129 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as stripearth electrode, including connection/ terminating with G.I. nut, bolt, spring, washeretc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt& spring washer spaced at 50mm) |
| 130 | Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required2.00 mm copper conductor ( 14SWG) |
| 131 | Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required2.65 mm copper conductor (12SWG) |
| 132 | Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG) |
| 133 | Supply and laying of the following sizes ofB class GI pipe laid 0.6 m below ground level including excavating trench ofsuitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class) |
| 134 | Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.2.00 mm (14 SWG) |
| 135 | Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG) |
| 136 | Supply and installation of 150 mm light duty exhaust fan in plastic body with outergrill in the existing opening, fixing necessary bolts and nuts, making good thedamages etc. as required including giving connections with required length of 24/0.20mm 3 core round copper conductor flexible chord etc as required |
| 137 | 63 A,415 volt , 2 Way neutral links mounted on DMC/SMC base |
| 138 | Supply and providing 63 A HRC fuse base with HRC fuse link |
| 139 | Charges for prepration of KSEB service connection documents for availing singlephase service connection and producing to the consumer including test report drawingetc. |
| 140 | Supply and providing 25x6 mm base bolt and nut with washers on the existing MSbox / earth bus etc. as required including drilling necessary holes are required |
| 141 | Supply and providing 12x3 mm brass bolt and nut with washers on the existing MSbox / earth bus etc. as required including drilling necessary holes as required |
| 142 | Supply and fixing cast aluminium stove enameled bulk head fitting withdeep<br> drawn anodised aluminium body, epoxy powder coated, heat resistantprismatic glass cover suitable to provide 9 W LED to wall / ceiling including givingconnections with required length of 160/0.20mm PVC insulated and PVC sheathed 3core round copper conductor flex wire conforming to relevant ISS or extending theorginal wiring and making good the surface as required |
| 143 | Supply and installation of dust and vermin proof wall mounding meter box (650x350x250mm ) SINTEX make (GSMB-6535) or equivalant with base platesuitable to fix three phase energy meter and HRC fuse units and nuetral link on wallusing suitable nut bolt etc. |
| 144 | Supply and providing 9W LED lamp in position as required |
| 145 | Supply and providing suitable size anchor bolt hook grouted on wall for service wire |
| 146 | Charges for prepration of KSEB service connection documents for availing threephase service connection / load regularisation and producing to the consumerincluding test report drawing etc. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
| 9 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail