|
| 1 | WELL RENNOVATION |
| 2 | OD509172/2025-2026:Bailing Out Water Using 5 HP Pump- Bailing Out Water With 5 HP Engine And Pump Set including Conveyance and Rent of Engine to Site, Cost of Fuel,Lubrication Oil and Other Stores, Pay of Staff etc Complete (OD Created based on Item in Data Book of DAR 60.2.2 , Irrigation) |
| 3 | 5.7:Reinforced cement concrete work in well - steining excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) derived from natural sources derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources derived from natural sources) |
| 4 | 5.9.12:Centering and shuttering including strutting, etc. and removal of form for:Well steining |
| 5 | OD509281/2025-2026:Sinking Well in All Classes of Soils Other Than Roack,To Lines And Levels And Plump By Scooping Out From Inside And Below the Steining Including The Use of Dredgers or Any Other Appliances, Hire And Labour Charge For Kentledge , Jetting, Dewatering, Blasting , Vibrating or Any Othe Method, Including Removal of Obstacles And Dumping The Soil Within a Distance of 150 m etc For Wells of 4.00 m To 5.50 m Outer Dia -1st Depth Up to 3.00 m below Spring Level (Std PWD Data 1965 Sl No:701) |
| 6 | OD509280/2025-2026:Sinking Well in All Classes of Soils Other Than Roack,To Lines And Levels And Plump By Scooping Out From Inside And Below the Steining Including The Use of Dredgers or Any Other Appliances, Hire And Labour Charge For Kentledge , Jetting, Dewatering, Blasting , Vibrating or Any Othe Method, Including Removal of Obstacles And Dumping The Soil Within a Distance of 150 m etc For Wells of 4.00 m To 5.50 m Outer Dia -2nd Depth Up to 3.00 m To 4.50 m below Spring Level (Std PWD Data 1965 Sl No:701) |
| 7 | 23.5:Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges |
| 8 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 9 | OD509269/2025-2026:DRY RUBBLE MASONRY - Dry Rubble Masonry Without Concrete Levelling Course, With Good Quality Blasted And Dressed Rubble,Including Packing to Compactness to Lines And Levels, Cost of All Material, Conveyance Charge, Labour Charges etc Complete as per Directions of Ofiicers at Site |
| 10 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 12 | 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. |
| 13 | 13.4.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand) |
| 14 | 50.2.26.1:Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge. |
| 15 | 51.2.3:Filling with Quarry Muck <br> Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade |
| 16 | 10.26.1:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube |
| 17 | OD510038/2025-2026:(OD From Spec:16:68) Providing and Laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of 6 mm Metal, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 18 | 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 19 | OD510080/2025-2026:Supplying And Fixing Name Board, With Granite Stone,Square or Rectangular Shape Suitableto Fixing Place,Minimum 0.50 Sqm To Maximum 0.60 Sqm, Fixed at Site with Cement Mortar1:4, 12 mm Thick, And Permanantly Engraving with good Paint, The Details of Work on the Stone as directedby the Officers, Including all Cost of Material, Conveyance, Labour etc Complete.., Please Enable Macros to View BoQ information |