| 1 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level complete all as specified and as directed. |
| 2 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft / loose soil complete all as specified and as directed. |
| 3 | Removing excavated material (Soils) from site to a distance not exc 50 mtr away and depositing where directed at a level not exc 1.5mtr above the starting point complete all as specified and as directed. |
| 4 | M&L for boring holes under road pavement by bocky, manually/mechanically in any type of soil upto 200 mm bore, complete all as specified and directed. |
| 5 | Taking down old unserviceable CI/DI/GI/cement pipe, joints, bends, elbow, tees, rubber joints upto 100 mm dia complete all as specified and directed. |
| 6 | Taking down old unserviceable CI/DI/GI/cement pipe, joints, bends, elbow, tees, rubber joints upto 150 mm dia complete all as specified and directed. |
| 7 | Taking down old unserviceable CI/DI/GI/cement pipe, joints, bends, elbow, tees, rubber joints upto 200 mm dia complete all as specified and directed. |
| 8 | Supplying, laying, jointing, testing and commmisioning of DI Pipe as per IS 8329, class K-7 with inside cement mortar lining with spigot and socket ends laid in trenches including rubber gasket joint (tyton joints) complete all as specified and as directed at site for 80mm bore pipeNote : - Joints shall be measured and paid separetely |
| 9 | '-Ditto- all as per item No. 7.00 but 100 mm bore pipe |
| 10 | '-Ditto- all as per item No. 7.00 but 150 mm bore pipe |
| 11 | '-Ditto- all as per item No. 7.00 but 200 mm bore pipe |
| 12 | Material and Labour for CI fittings/specials such as tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of the following sizes confirming to IS: 1538-1993 complete upto 150 mm bore all as specified and directed. |
| 13 | -Ditto- all as per item No. 11.00 but above 150 mm and upto 200 mm bore |
| 14 | Material and Labour for DI fittings/specials such as tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of the following sizes confirming to IS: 9523 complete upto 100 mm bore all as specified and directed. |
| 15 | -Ditto- all as per item No. 13.00 but above 150 mm and upto 200 mm bore |
| 16 | Material and labour for Run lead joint including jointing material for CI/DI pipe of 80 mm bore, all as specified and directed. |
| 17 | -Ditto- all as per item No. 15.00 but 100 mm bore |
| 18 | -Ditto- all as per item No. 15.00 but 150 mm bore |
| 19 | -Ditto- all as per item No. 15.00 but 200 mm bore |
| 20 | Material and labour for Rubber Gasket Joint (Tyton Joint) including jointing material for DI/CI pipe of 80 mm bore, all as specified and directed. |
| 21 | -Ditto- all as per item No. 19.00 but 100 mm bore |
| 22 | -Ditto- all as per item No. 19.00 but 150 mm bore |
| 23 | -Ditto- all as per item No. 19.00 but 200 mm bore |
| 24 | Taking down old unserviceable MS pipe, joints, bends, elbow, tees upto 250 mm dia complete all as specified and directed. |
| 25 | Supplying, laying, jointing, welding & testing MS Pipe (Heavy duty class 'C') not less than 4 mm thick laid in trenches or on floors for connections to centrifugal pump sets for suction, pump to header and to connect out going water main CI/DI pipe line of 100 mm bore complete all as specified and directed. Note:- MS Flanges and Flange joints complete with jointing materials shall be measured and paid separately. |
| 26 | -Ditto- all as per item No. 24.00 but 150 mm bore |
| 27 | -Ditto- all as per item No. 24.00 but 200 mm bore |
| 28 | -Ditto- all as per item No. 24.00 but 300 mm bore |
| 29 | Supplying and fixing, MS flanges of 100 mm bore not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and directed. |
| 30 | Supplying and fixing MS flanges of 150 mm bore not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and directed. |
| 31 | Supplying and fixing MS flanges of 200 mm bore not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and directed. |
| 32 | Supplying and fixing MS flanges of 300 mm bore not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and directed. |
| 33 | M&L for Flanged Joints with rubber or fibre board gasket including nuts, bolts and double washers of 100 mm bore complete all as specified and directed. |
| 34 | -Ditto- all as per item No. 32.00 but 150 mm bore |
| 35 | -Ditto- all as per item No. 32.00 but 200 mm bore |
| 36 | -Ditto- all as per item No. 32.00 but 300 mm bore |
| 37 | Supply, fixing, jointing & testing of cast Iron Sluice Valve, ISI Marked, flanged ends drilled, pressure rating PN-1.0, PD Short body, confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unserviceable sluice valve of f80 mm bore complete all as specified and as directed at site. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. |
| 38 | -Ditto- all as per item No. 36.00 but 100 mm bore |
| 39 | -Ditto- all as per item No. 36.00 but 150 mm bore |
| 40 | -Ditto- all as per item No. 36.00 but 200 mm bore |
| 41 | Supply, fixing, jointing and testing of cast iron Non Return valve without by pass arrangement, swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete including taking out unserviceable NRV of 80 mm bore complete all as specified and as directed at site. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. |
| 42 | -Ditto- all as per item No. 40.00 but 100 mm bore |
| 43 | -Ditto- all as per item No. 40.00 but 150 mm bore |
| 44 | -Ditto- all as per item No. 40.00 but 200 mm bore |
| 45 | Supply, installation and testing of flanged ends water meter ISI marked woltman type, Class 'B' of 80 mm bore and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclined/vertical position, including taking out unserviceable water meter complete all as specified and directed at site. Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item. |
| 46 | -Ditto- all as per item No. 44.00 but 100 mm bore |
| 47 | -Ditto- all as per item No. 44.00 but 150 mm bore |
| 48 | Taking up or down GI tubing and connections of 15 mm bore pipe from trenches / wall / floor including cleaning for refixing or removal complete all as specified and as directed. |
| 49 | -Ditto- all as per item No. 47.00 but 20 mm bore pipe |
| 50 | -Ditto- all as per item No. 47.00 but 25 mm bore pipe |
| 51 | -Ditto- all as per item No. 47.00 but 40 mm bore pipe |
| 52 | -Ditto- all as per item No. 47.00 but 50 mm bore pipe |
| 53 | Refixing/relaying only GI pipe medium grade with all new fittings fixed complete to walls and ceiling or in floors on old/new position as directed of 15 mm bore. |
| 54 | -Ditto- all as per item No. 52.00 but 20 mm bore |
| 55 | -Ditto- all as per item No. 52.00 but 25 mm bore |
| 56 | -Ditto- all as per item No. 52.00 but 40 mm bore |
| 57 | -Ditto- all as per item No. 52.00 but 50 mm bore |
| 58 | Supplying & fixing gun metal gate valves with iron wheel head, screwed both ends for iron pipe, ISI Marked, as per IS: 778 of 15 mm bore including taking out unserviceable gate valves complete all as specified and as directed at site. |
| 59 | -Ditto- all as per item No. 57.00 but 20 mm bore |
| 60 | -Ditto- all as per item No. 57.00 but 25 mm bore |
| 61 | -Ditto- all as per item No. 57.00 but 40 mm bore |
| 62 | -Ditto- all as per item No. 57.00 but 50 mm bore |
| 63 | Labour only for cutting of CI /DI/GI pipe in position for reducing to required length for insertion of new tees, branches etc of 80 to 150 mm bore complete all as specified and directed. |
| 64 | Material and labour for renewal of water pressure gauge (0-5 Kg/cm square) 100mm dial size including boring, threading, welding in CI/DI/GI of any sizes and connected with suitable size of 'U' type MS/CP pipe with ON OFF cock complete all as specified and directed. |
| 65 | Material and labour for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation of brick pillar to support the pipe line including demolition of old PCC and removing the debris from site complete all as specified and as directed at site. |
| 66 | Material and labour for brick work with sub class 'B' bricks straight or curved on plan exc. 6M mean radius built in CM (1:4) as in brick pillar of required size and shape to support the pipe line including demolition of old brickwork & removing from site complete all as specified and as directed at site. |
| 67 | Material and labour for rendering plaster 15 mm thick with cement mortar (1:6) on fair faces of brick work / concrete surfaces, finished the surface even and fair complete all as specified and directed. |
| 68 | Material and labour for GI tubing 'medium grade' with all accessories including bends, elbow, socket, union, nipple etc including taking up or down old unserviceable GI tubing of 15 mm bore complete all as specified and directed. |
| 69 | -Ditto- all as per item No. 67.00 but 20 mm bore |
| 70 | -Ditto- all as per item No. 67.00 but 25 mm bore |
| 71 | -Ditto- all as per item No. 67.00 but 40 mm bore |
| 72 | -Ditto- all as per item No. 67.00 but 50 mm bore |
| 73 | -Ditto- all as per item No. 67.00 but 80 mm bore |
| 74 | Supply, installation and testing flanged ends strainer/dirt box of 80 mm bore with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclined/vertical position, including taking out old unserviceable strainer/ dirt box complete all as specified and directed at site. Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item. |
| 75 | -Ditto- all as per item No. 73.00 but 100 mm bore |
| 76 | -Ditto- all as per item No. 73.00 but 150 mm bore |
| 77 | Supply, fixing, jointing & testing butterfly valve (wafer type) of 50 mm bore as under, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, including taking out unserviceable butterfly valve complete all as specified and as directed at site. Note:- Jointing material shall deemed to be included in the unit rate of this item. |
| 78 | -Ditto- all as per item No. 76.00 but 80 mm bore |
| 79 | -Ditto- all as per item No. 76.00 but 100 mm bore |
| 80 | -Ditto- all as per item No. 76.00 but 150 mm bore |
| 81 | M&L for excavation in any type of soil through trenchless technology by HDD (Horizontal directional drilling method) including preparing and setting up the plant and equipment. Preparing new pipe work material including all related civil work and mechanical work like excavation, shoring/strutting etc drilling, stringing, reaming and pulling back the new pipe work on the path alignment proper disposal of drilling fluid and ground penetrating radar survey to protect any exiting utilities at the pipe installation location restoration of site after completion all inclusive as per and STT IS No.2.3.2.2.2.2. second edition 2008 code of pactice for trenchless technology suiting Indian condition for making horizontal bore of size 350mm dia suitable for HDPE pipe insertion under road crossing /hard standing including HDPE pipe 250 mm nominal dia of 25 mm min. wall thickness of grade PE 80 for protection of MS/DI pipe to any depth by manually or any means complete all as specified and directed. Note:- (a) MS Pipe/DI will be measured and paid for separately under respective items.(b) Permission required from civil authrority/department prior to executing the work is the responsibility of the Contractor and the cost for the same shall be deemed to be included in unit rate quoted by the Contractor.(c) 250 mm HDPE pipe shall deemed to be included in the unit rate of this item. (xi) All existing earthing of the lifts shall be maintained and made fully functional by the contractor to the entire satisfaction of the Engr-in-Charge. Please Enable Macros to View BoQ information |