| 1 | Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth and getting out for laying of cable etc complete all as specified. |
| 2 | Returning, filling in soft/loose soil including spreading, levelling, watering and well ramming, in layers not exc 25 cm complete all as specified. |
| 3 | Removing of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified. |
| 4 | M&L Protection to cable with one layer of bricks laid flat abutting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ burnt-clay bricks, complete all as specified. (Note: the gap between two adjustable bricks should not exceed 10 mm ) |
| 5 | M&L Un washed dry river sand as cushioning of under ground cable and punned after laying complete all as specified. Note: Only punned thickness will be measured. |
| 6 | Taking out old un-servicable/ faulty PVC armoured LT under ground cable of any size any core complete all as specified. |
| 7 | S&F or laying ross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts grade of following cross-sectional area laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc including commissioning and testing of following sizes complete all as specified.(Note: :- (i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately.) |
| 8 | (a) 95 sqmm 3.5 core |
| 9 | (b) 70 sqmm 3.5 core |
| 10 | (c) 35 sqmm 3.5 core |
| 11 | (d) 25 sqmm 4 core |
| 12 | (e) 16 sqmm X 4 core |
| 13 | (f) 10 sqmm X 2 core |
| 14 | Taking down non functional/ unserviceable /energy inefficient street /security light fittings of capacity upto 250W existing and re-fixing after minor repair to existing / directed location complete all as specified.Note: Material shall be measured and paid searately under respective items. |
| 15 | Supply only LED drivers rated voltage 12/24 volt maximum out put power 40 W typical efficiency 93% complete all as specified. |
| 16 | Supply only LED drivers rated voltage 12/24 volt maximum out put power 70 W typical efficiency 93% complete all as specified. |
| 17 | Supply only LED drivers rated voltage 12/24 volt maximum out put power 90 W typical efficiency 93% complete all as specified. |
| 18 | Supply only LED drivers rated voltage 12/24 volt max out put power 150 W typical efficiency 93% complete all as specified. |
| 19 | Dismantling old U/S GI bracket of any size & length complete all as specified. |
| 20 | S & F street light GI bracket of 0.9 mtr long made out of 32 mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of flat iron 32 x 4mm including nuts bolts & washers for fixing on wall complete necessary fixing arrangements on pole complete all as specified. |
| 21 | S & F in replacement 4 sqmm solid conductor 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed twin core cable flat or circular from junction box to fitting complete all as specified. |
| 22 | S&F in repair of automatic Infrared Sensor used in NATURE SWITCH for automatic switching of street lights. Nature switch operation switch operation should be based on Natural light Lux level. Required illuminance level for Switching ON is<= 30 lux and for switching OFF>=10 lux. The sensor should also have part night operation facility of min 4 hours to max 12 hours complete all as specified.Make :Nature switch:Kakatiya Energy system/Bajaj/Healer |
| 23 | Supply, install, test and commissioning factory made THERMOPLASTIC/HDPE CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with terminal incl Aluminium bus bar of 63amp-04 Nos and MCB SP 6amp-01 No complete all as specified. |
| 24 | S&F new generation energy saving and environmental friendly long life varsatile pressure die cast aluminium IP66 road way light fitting with high power LED as light source of capacity 45 watts (Surge protection of the light should be 10 KV )with suitable drivers etc , fixing to wall / pole with complete all as specified. |
| 25 | All as above item No 18 but 60 watt LED fittings complete all as specified. |
| 26 | All as above item No 18 but 90 watt LED fittings complete all as specified. |
| 27 | All as above item No 18 but LED flood light fittings 120 watts complete all as specified. |
| 28 | All as above item No 18 but LED flood light fittings 200 watts complete all as specified. |
| 29 | Supply and fixing in replacement Metal core PCB of Lithium base Energy efficient integrated Solar street light complete all as specified. |
| 30 | Supply and fixing in replacement battery rating 12.8V/42Ah-BIS standard of Lithium base Energy efficient integrated Solar street light complete all as specified. |
| 31 | M&L for painting on steel pole initially scraping deteorated paint by emery paper and complete removal of rusted suface, painted with one coat of red oxide zinc chrome primer on exposed prepared surface and providing 03 Nos of 30 cm wide circular bands with black and yellow paint starting from bottom level at a gap of 30 cm in between 2 bands and numbering of pole with yellow paint over black painted background at the height og 02 meter from the bottom of pole with 02 cm larger Bold letter of height 2 inch wide complete all as specified. |
| 32 | Supply and fix MCB’s single pole 6-32 Amps, 230 volts with ‘C’ curve, fixed complete including taking down complete all as specified. |
| 33 | S&F 20 mm dia Unplasticised PVC pipes of pressure rating 10 Kgf/cm2 fixed on pole with suitable size of clamps made out of MS flat with the size of pole , nut, bolt etc complete all as specified. |
| 34 | Supply jointing connecting in repair and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 10/16/25 Sqmm suitable for 4 core complete all as specified. |
| 35 | S & F PVC insulated stranded copper conductor cable of size 1.5 sqmm x 3 core from Juction box to street light complete all as specified. |
| 36 | S&F in replacement of 2 Pole 18 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified. |
| 37 | S&F in repair 4 Pole 63 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified. |
| 38 | Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified. |
| 39 | Boring of holes under road, pavement, hard standing for laying of pipe upto 90 mm bore complete all as specified.Note :- GI pipe shall be measured and paid separately. |
| 40 | S & F or laying galvanised steel tubing Light grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of following size:- |
| 41 | (a) 40 mm bore. |
| 42 | (b) 50 mm bore. |
| 43 | Supply and fixing of Lithium base Energy efficient integrated Solar street light of 30 watt in Aluminium Die casting body ,corrosion resistance,built in high efficiency solar panel and long life lithium ferro phosphate battery with high efficiency microprocessor based charge controlar Automatic dusk to input voltage 12.8 V with minimum 30 AH battery capacity ,Driver efficiency .85%,PV module minimum output capacity 60 W/h Mono itself will be used to sense the ambient light to switch ON/OFF the Lamp from outside from Light fittings and controled from Pole controlling switch,inbuilt MPPT charge controller,IP65,both PIR and fixed dimming available,4500 lumens (at full brightness) with grater than 150 lumen per att,5700ANSI,, CRI.70, moptical used, Metal core PCB,Low voltage cutoff ,high power LED,wide beam Angle(135/85 degree) with PIR Sensor LED Life 50000 hrs (LM80 cerified LED),weight less than 15 kg with Green/Red indicator with with battery rating 12.8V-BIS standard along with suitable MS clamp for fixing in PCC pole/steel tubular pole/Bldg wall complete all as specified. |
| 44 | Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2\\" (inch) wide complete all as specified.Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule. |
| 45 | M&L for cement concrete 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foudation,filling and mass concrete complete all as specified. |
| 46 | M&L for cement concrete 1:3:6 type C2 (using 40 mm graded crushed stone aggregate) as in foudation,filling and mass concrete complete all as specified. |
| 47 | M&L for cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate for pedestal of poles/ coping including necessary formwork, fair finishing to exposed surfaces using extra cement complete all as specified. |
| 48 | M&L for Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm buried directly in the ground vertically to depth not less than 3 Mtr below the ground level with the top edge of earth plate, depth not less than 2.25 Mtr below the ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts and washers protected by GI tubing light grade 20 mm dia uptoTest point 20 mm dia watering pipe with funel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil ,removal of surplus sil and providing charcol dust & salt layers all around the earth plate upto 15 cm all as required complete all as specified.(Note:- Up to 7.5 Mtr length of pipe of 20 mm dia and GI strip shall be deemed to be included in unit rate quoted by tenderer GI pipe and GI wire ) |
| 49 | Supply and fix in replacement of IP65 rated LED Bollard Mushroom type with soft 360 deg light distribution with base plate and necessary foundation and connected electric connections and PCC work complete and IP 65/66 complete all as specified. Please Enable Macros to View BoQ information |