| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 5 | 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
| 8 | Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.. |
| 9 | Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. |
| 10 | 1:1½:3 (1 Cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 11 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 12 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 13 | Single rubber stopper |
| 14 | Providing and fixing Pre-laminated medium density fibre board IS: 14587:1998 marked, with one side decorative lamination other side balancing lamination Grade-I(exterior grade) in shelves with screws and fittings wherever required, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand (fittings to be paid separately). |
| 15 | Pre-laminated with decorative lamination one side and other side balancing lamination exterior Grade - I MDF Board 18 mm thick confirming to IS:14587 |
| 16 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 17 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 18 | Chequerred precast cement concrete tiles 22 mm thick in footpath &courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 19 | Dark shade pigment using ordinary cement. |
| 20 | 12 mm cement plaster of mix : |
| 21 | 1:6 (1 cement: 6 fine sand) |
| 22 | 6 mm cement plaster of mix : |
| 23 | 1:3 (1 cement: 3 fine sand) |
| 24 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 25 | Two or more coats on new work. |
| 26 | Finishing walls with textured exterior paint of required shade : |
| 27 | Old work (One or more coats) applied @ 1.82 ltr/10 sqm. |
| 28 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 29 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 30 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 31 | Semi rigid pipe |
| 32 | 32 mm dia |
| 33 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External work |
| 34 | 65 mm dia. nominal bore (Available Pipe) |
| 35 | Providing and laying factory made Precast concrete solid blocks of 200 mm thickness of grade M10 made of C&D waste from approvedmanufacturer in foundation and plinth in: |
| 36 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 37 | Removing the damaged sanitary and water supply fittings and replacing them with new fittings including necessary white lead/ lead wool ,credit of serviceable materials,etc all complete as directed by the Engineer - in - charge. |
| 38 | PTMT stop cock 15 mm nominal bore, 86 mm long. Weighing not less than 88 gms. of approved quality and colour. |
| 39 | CP Brass pillar tap of approved brand and manufacturer |
| 40 | Attending repairs to Low level PVC flush tanks by replacing necessary parts as per requirement etc all complete,as directed by the engineer in charge. |
| 41 | Cleaning/Sweeping of external path way/CC road, Portico etc., including cleaning of spouts, removal of debries, dead-leaves, garbage etc., all complete as directed. |
| 42 | Trimming of grown up trees by cutting branches up to 3.00 metre from gound level including disposal to dumping ground etc. complete as directed by Engineer-In-Charge. Up to 5 Trees |
| 43 | Cutting of tree roots exposed above the ground level including cutting of branches and stacking of serviceable material and disposal of unserviceable material. Girth up to 600 cm. |
| 44 | Removing 5.5mm thick partition glass from the aluminium partition and staking the same in designated place etc all complete as directed by the engineer in charge. For glass panes of size up to 1.00X1.05M up to floor 3 level. |
| 45 | Re fixing available 5.5mm thick partition glass in aluminium partition etc all complete as directed by the engineer in charge. For glass panes of size up to 1.00X1.05M up to floor 3 level. |
| 46 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all loads including all lifts involved. Credit for available dimantled unserviciable materials to agency (a) Old rusted MS/GI sheet, angle, flat, Tee and the like Please Enable Macros to View BoQ information |