|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. DSR Code 1.3.3 |
| 2 | Wiring for circuit / sub main wiring along with earth wire with the following. Sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required.2 X 2.5 Sq. mm. + 1 X 2.5 Sq. mm. earth wire. DSR Code 1.14.2 |
| 3 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. DSR Code 1.12 |
| 4 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 10 sq. mm + 1 X 6 sq. mm earth wire DSR Code 1.14.5 |
| 5 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.DSR Code 1.32 |
| 6 | Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required DSR Code 1.38 |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. DSR Code 1.31 |
| 8 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. DSR Code 1.25 |
| 9 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Double door DSR Code 2.3.4 |
| 10 | Supplying & Fixing 5 amp. to 32 amp. rating 240/415 V, volt miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required, Single Pole. DSR Code 2.10.1 |
| 11 | Supplying and fixing 63A rating,double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. DSR Code 2.12.2 |
| 12 | Supply of 12W LED(COB) Down light with crisp light throw and high CRI.Make – Bajaj/orient/Havells/Djb approved make |
| 13 | Supply of Higher wattage decorative ultra slim LED lighting fixture (Batten) with high lumen output, environmental friendly energy efficient of capacity 36 W Make – Bajaj/orient/Havells/Djb approved make Make – Bajaj/orient/Havells/Djb approved make |
| 14 | Supply of 1200 mm. Sweep Ceiling Fans. Make :- Bajaj/Havells/Crompton/Djb Approved Make |
| 15 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. DSR Code 1.41 Please Enable Macros to View BoQ information |