| 1 | E/W in excavation for structure as per drawing and technical specification clause305.1 including setting out, construction of shoring and brading, removal of stumps and other deleterious material and disposal utp a lead of 50m, dressing of sides and bottom backfilling in trenches with excavated suitable material.S.O.R. Item No. 3.13 (i) B |
| 2 | Construction of dry rubble flooring at cross drainage works for relatively less important works.S.O.R. Item No. 16.09 |
| 3 | Plain/Reinforced cement concrete in open foundation complete as per drawing and Technical Specifications(P.C.C. Grade M-15)S.O.R. Item No. 12.08 A Case II |
| 4 | Stone masonry work in cement mortar 1:3 in foundation complete as per drawing and technical specifications.Square Rubble Coursed Rubble Masonry (1st sort) in C.M. (1:3)S.O.R. Item No. 12.07 (A) |
| 5 | Stone masonry work in cement mortar 1:3 for substructure complete as per drawing and technical specificationsCoarse Rubble Masonary in C.M. (1:3) in sub-structureS.O.R. Item No. 13.04 B |
| 6 | Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications(P.C.C. Grade M-15)S.O.R. Item No. 13.05 A (p) |
| 7 | Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications(P.C.C. Grade M-20 in S/S)S.O.R. Item No. 13.5 B (p) |
| 8 | Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical speciofications(P.C.C. Grade M-25 in Deck Slab)S.O.R. Item No. 13.05 F (p) |
| 9 | Providing and laying Cement Concrete Wearing Coat M-30 grade including reinforcement complete as per drawing and Technical SpecificationsS.O.R. Item No. 14.04 |
| 10 | Supplying, fitting and placing HYSD bar reinforcement in substructure complete as per drawing and technical specificationsS.O.R. Item No. 13.06 |
| 11 | Plastering with cement mortar (1:3) on brick / stone masonary work in substructure as per technical specificationsS.O.R. Item No. 13.03 |
| 12 | Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces)S.O.R. Item No. 8.08 |
| 13 | Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.S.O.R. Item No. 14.17 (ii) |
| 14 | Providing weep holes in Brick / stone masonry/ Plain/Reinforced concrete abutment , wing wall/ returen wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20 H towards drawing face. Complete as per drawing and technical specifications.S.O.R. Item No. 13.08 |
| 15 | Backfilling behind abutment, wing wall and return wall with Sandy Material complete as per drawings & technical specification ClauseS.O.R. Item No. 13.09 (B) |
| 16 | Add 18% GST |
| 17 | Add 1% Labour Cess Please Enable Macros to View BoQ information |