| 1 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-259) Lift 0 to 1.5 M1.Fatate plot |
| 2 | Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259) Lift 0 to 1.5 M 1.Fatate plot |
| 3 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259) |
| 4 | Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263) |
| 5 | Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, excluding GST lev-ied by GOI & GOM in all respect including inspec- tion charges, transport to departmental stores, unloading and stacking etc. complete as per IS-458/1988.600 mm.dia. Class ‘NP-III' ( For 2.00 m. length )1.Fatate plot |
| 6 | Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge (For all class of pipes.) as per IS- 783-1985.600 mm.dia. Class ‘NP-III' ( For 2.00 m. length )1.Fatate plot |
| 7 | Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).1.Fatate plot |
| 8 | Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material, except cement solvent, rubber ring, as per IS code, etc. complete (with cement solvent joint / ring fit joint).1.Fatate plot |
| 9 | Providing and constructing on sewer, B. B. masonry circular manhole with concentric cone 12 M dia at bottom and 0.5 M dia. at top and upto a depth of 2.00 M with 23 crh brick work in CM 1:4 proportion excluding excavation including foundation concrete 250 mm thick and haunches and channels in C. C. 1:2:4 proportion, finishing channels in smooth rendering,providing C.l. dapuri type steps each weighing 5.5 kg.1:2:4 coping and providing and fixing approved make and quality S.F.R.C.frame and cover of 56 cm dia. etc. complete as directed by Engineer in-charge. (NOTE -The depth of chamber is 2m then we taking the depth upto 1m & the rate is half of the DSR rate ) |
| 10 | Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.1.Fatate plot |
| 11 | Providing and fixing mild steel grill work for windows, ventilators, etc. 20 Kilogram/SquareMetre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.1.Fatate plot |
| 12 | Add 18% G.S.T. Charges1.Fatate plot |
| 13 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-259) Lift 0 to 1.5 M2.Salgar Wasti |
| 14 | Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259) Lift 0 to 1.5 M 2.Salgar Wasti |
| 15 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259) |
| 16 | Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263)2.Salgar Wasti |
| 17 | Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, excluding GST lev-ied by GOI & GOM in all respect including inspec- tion charges, transport to departmental stores, unloading and stacking etc. complete as per IS-458/1988.600 mm.dia. Class ‘NP-III' ( For 2.00 m. length )2.Salgar Wasti |
| 18 | Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge (For all class of pipes.) as per IS- 783-1985.600 mm.dia. Class ‘NP-III' ( For 2.00 m. length )2.Salgar Wasti |
| 19 | Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).90 mm.dia. Pvc 4 kg/cm22.Salgar Wasti |
| 20 | Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material, except cement solvent, rubber ring, as per IS code, etc. complete (with cement solvent joint / ring fit joint).90 mm.dia. Pvc 4 kg/cm22.Salgar Wasti |
| 21 | Providing and constructing on sewer, B. B. masonry circular manhole with concentric cone 12 M dia at bottom and 0.5 M dia. at top and upto a depth of 2.00 M with 23 crh brick work in CM 1:4 proportion excluding excavation including foundation concrete 250 mm thick and haunches and channels in C. C. 1:2:4 proportion, finishing channels in smooth rendering,providing C.l. dapuri type steps each weighing 5.5 kg.1:2:4 coping and providing and fixing approved make and quality S.F.R.C.frame and cover of 56 cm dia. etc. complete as directed by Engineer in-charge. (NOTE -The depth of chamber is 2m then we taking the depth upto 1m & the rate is half of the DSR rate ) |
| 22 | R.C.C.Chamber cover with frame 45cm*45cm Medium Duty 100kg |
| 23 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete |
| 24 | Providing internal cement plaster 12mm thick in a single coat using Ready to use wall plaster to concrete or brick surface in all positions including scaffolding and curing complete.Providing groove at joint of B.B.Masonry and concrete members complete. b) cement ratio 1:4 With Prior Approval of Concerned S.E. |
| 25 | Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. |
| 26 | Providing and fixing mild steel grill work for windows, ventilators, etc. 20 Kilogram/SquareMetre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. |
| 27 | Providing and fixing 10 cm PVC nahani trap with grating etc. complete. |
| 28 | Add 18% G.S.T. Charges1.Fatate plot Please Enable Macros to View BoQ information |