| 1 | Providing & repairing of 10 HP, 2900 RPM, 25 mtr. head 3 phase monoblock kirlosker make 2 motor pump set at Gadhkalika pump house including following the parts & work. |
| 2 | Carefully disconncting of above motor pump set at suction & delivery base plate i/c complete servicing of pump chamber pulley movement of impeller unit with fitting. |
| 3 | Providing & fixing of hardware material including nut bolt packing gland etc. |
| 4 | Providing & fixing G.M. long bush & oil seal. |
| 5 | Providing & fixing of 100 mm. dia. Footvalve changing heavy duty new compressed lather complete opening, fitting, changing including with as per required G.I. nut bolt & wiser etc. |
| 6 | Providing & making of bearing sheet by welding & lath machine turning & polishing on pump shaft. |
| 7 | Providing & complete servicing of pump chamber fully movement of impuller unit with as per required fitting work including check nut, nut bolt, wiser, oil paper etc. complete |
| 8 | Providing & cleaning of slot by CTC and removing moisture then varnishing and drying by heating process. |
| 9 | Providing & fixing of drive & non driver bearing as per required keth work. |
| 10 | Providing and fixing of terminal plate. |
| 11 | Providing & fixing making of diamtrically balancing rotor assembley |
| 12 | Labour charge for complete repairing opening & refitting of 100 mm dia non return valve & sluice valve i/c cutting of old damaged nut bolt & providing recasting finishing, machning of gate plate holding rod assembley as per sample and required packing, complete nut bolt for fitting on delivery pipeline at site. |
| 13 | Complete refitting of pump after repairing and checking of horizontel and vertical alligment of motor pump set coupling with trial testing on load etc including loading uloading charge from site to work shop and back |
| 14 | Providing & complete rewinding work of 10 H.P 440 volt 3 phase mono block motor set cutting of burnt winding wire & slots malted chips P.V.C. material from slots cleaning & decarborizing of complete stator slots rotor etc. making of supper enambelled copper in sulated new coils fixing in the stator slots insulation etc complete i/c soldering brazing refitting of rewinding motor allingment and dynamically balance of rotor horizontal allingment with pump trial & testing etc, complete job |
| 15 | Providing & fixing of C.I. motor cooling fan |
| 16 | Complete refitting on motor and base plate checking of horizontal and vertical alignment of motor pump set, coupling with pump and trial testing etc. i/c including loading and unloading charge site to work shop and back. |
| 17 | Providing & complete servicing of pump chamber fully movement of new impuler unit with as per required fitting work including check nut, nut-bolt, wiser, oil paper etc. complete. |
| 18 | Manufacturing and fitting by 50 × 8 m.m. plate with 20 m.m. dia. m.s. round bar welding in verticla position 300 m.m. gap internal bitoring both plate i/c dismertling of old damage leddder cutting welding and fitting etc Size 4.50 mt. long × 0.6 mt. wide 1 nos approx wt. 80 kg. |
| 19 | Providing for complete repairing & replacing burnet equipment for 10 HP panel with 2 set starter power supply wiring i/c the following works. |
| 20 | Labor charge for complete repairing of 20 H.P. penal with 3 starter complete repair, replacement of tripping system changing of conctact & burnet equipment replacement with complete power, control wiring of panel starter i/c trail & testing at site on load. |
| 21 | Providing for complete replacing 250/300 amp. 415 volt 50 Hz. Moulded case circuit breaker (MCCB) of any standard make for main power supply equipment. |
| 22 | Providing & fixing of indication lamp |
| 23 | Providing & fixing of relay unit range 28-42 amp. |
| 24 | Providing & fixing of ML-4 contactor |
| 25 | Providing & fixing of ML-2 contactor |
| 26 | Providing & fixing of ML-1.5 contactor |
| 27 | Providing & fixing of on/off switch |
| 28 | Providing & fixing of timer assembly |
| 29 | Providing & fixing of 63 amp. MCCB, 415 v., 50 hz., for star delta starter |
| 30 | Providing & fixing of ampier meter 0-100 amp. |
| 31 | Providing & fixing of volte meter 0-500 v. |
| 32 | Providing & fixing of current transformer. (CT) range 100-200/5 amp. for majouring of main panel ampier |
| 33 | Provding & fixing of heavy duty capacitor 440 v. 7.5 KVAR capacitor with complete as per required work. |
| 34 | Labor charge for complete repairing opening & refitting of 150 mm dia non return valve & sluice valve i/c cutting of old damaged nut bolt & providing recasting finishing, machining of gate plate holding rod assembly as per sample & required packing, complete nut bolt for fitting on delivery pipe line at site as per following items. |
| 35 | Supply of S.S. 410 spindle rod without G.M. check nut for 150 mm. dia. |
| 36 | Recasting of 150 mm dia sluice valve G.M. check nut i/c recasting, finishing, machining & threading as per sample & cost of extra material complete work. |
| 37 | Repairing of 150 mm. dia. sluice valve C.I. fixture check nut catcher both side i/c welding, finishing cutting as per size of check nut. |
| 38 | Labor charge of opening & refitting of 150 mm. dia. sluice valve i/c cutting of old damaged nut bolt, removal of damaged gland packing, rubber packing, providing, fixing of new by fabricated parts & greasing properly cost of nut bolt, over hanting the valve transportation of material T&P testing & making with risk cover as per requirement. |
| 39 | Providing & fixing of presure gauge meter 0.0 to 7 or 0.0 to 10 Kg./cm2 size 150 mm dia with presure control tube, nut bolt, socket, GI nipple with GM valve 150 mm dia etc complete work. Please Enable Macros to View BoQ information |