| 1 | Supplying of approved make wall fan oscillating type AC 230-250 volt 400 mm sweep with base , blades , guard , speed regulator etc. and other accessories .[Orint /Havells ] |
| 2 | Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length. |
| 3 | Excavation of soil for installation of Earth Electrode and filling & ramming For Soft Soil |
| 4 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level by TATA-Medium GI pipe. |
| 5 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. |
| 6 | Connecting the equipments body to earth busbar including S & F 25 mm x 6mm galvanised(Hot Dip)MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts,washers etc. / welding properly as per direction of E.I.C. |
| 7 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. |
| 8 | Extra for treatment of soil by using salt & charcoal or coke for plate electrode |
| 9 | Supplying of(EPC make)exhaust fan 225 mm sweep 900/1400 (9\\") heavy duty with mounting frame , blades A C 230-250 Volt as requiredExhaust fan 225 mm sweep 900/1400 (9\\" ) |
| 10 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for following Exhaust fan.23 cm Exhaust fan (9\\") |
| 11 | Supply & Fixing Aluminium louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) for following Exhaust fan. 23 cm Exhaust fan (9\\") |
| 12 | Supply & delivery of 1200mm (48 inch)sweep 1 phase 60/70 watt 5 star heavy duty AC ceiling fan complete with all accessories i.e. blades, down rod ,canopy, fork, rubber bush etc[ Orint Quasar/Crompton |
| 13 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 14 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Legrand) on existing Modular GI switch board with top cover plate incl. Making necy. connections etc . |
| 15 | Supplying of approved make wall fan oscillating type AC 230-250 volt 400 mm sweep with base , blades , guard , speed regulator etc. and other accessories |
| 16 | Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length |
| 17 | Supply and delivery of TMC 502 Conventional industrial batten Philips double LED fitting model no. : TMC 502 P 2 xT- LED 22 watt P3241 with 2 no. MAS LED tube 1200 mm 18 W 865 T8 I- 2100 Im including necessary connection . (Warranty should not be less than 02 years) (HSN Code - 9405) |
| 18 | Fixing only single LED tube light fitting complete with all accessories suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/ 0.20 mm(1.5sqmm.) flexible copper wire of 1.10 mt. length. |
| 19 | Supply & Fixing of 23.0 Watt LED Lamp ,make Crompton |
| 20 | Excavation of soil for installation of Earth Electrode and filling & ramming For Soft Soil. |
| 21 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level by TATA-Medium GI pipe. |
| 22 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. |
| 23 | Connecting the equipment’s body to earth busbar including S & F 25 mm x 6mm galvanised(Hot Dip)MS flat on wall/floor with GI saddles as required and connection to equipment incl. drilling holes, with bolts, nuts, washers etc. / welding properly as per direction of E.I.C. |
| 24 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. |
| 25 | Extra for treatment of soil by using salt & charcoal or coke for plate electrode. Please Enable Macros to View BoQ information |