Sales : +91-777 804 8217
| Sl. No. | Item Name |
| 1 | secure fit, breathable, thin ,soft and flexible polyurethane film. waterproof & bacteria proof dressing. with integrated split liner.with integrated split liner and printed 1cm square grid.10cmx10m(1 roll) proprietary article certificate (pac) with usfda |
| 2 | Innovative Surgical Post Operative Dressing coated with Proprietary Dialkylcarbamoyl chloride (DACCTM) technology impregnated acetate tissue with absorbent pad and transparent film border. Hydrophobic interaction irreversibly binds bacteria and fungi rendering them inactive preventing toxin release and replication. Binds 108 bacteria within 2 hours even virulent bacteria like MRSA and VRE. With this technology no known cytotoxicity, resistance, and systemic absorption 4.5cmX11.5cm Proprietary Article Certificate (PAC) with USFDA |
| 3 | Innovative Surgical Post Operative Dressing coated with Proprietary Dialkylcarbamoyl chloride (DACCTM) technology impregnated acetate tissue with absorbent pad and transparent film border. Hydrophobic interaction irreversibly binds bacteria and fungi rendering them inactive preventing toxin release and replication. Binds 108 bacteria within 2 hours even virulent bacteria like MRSA and VRE. With this technology no known cytotoxicity, resistance, and systemic absorption 6cmX20cm Proprietary Article Certificate (PAC) with USFDA |
| 4 | HYDROSURGERY SYSTEM1. It should be a Hydrosurgery powered device for surgical wound necrotic, producing high pressure jet of sterilesaline, creating venturi effect at the distal tip of the hand piece.2. It should have a graduated power console (10 settings) for hydro surgical Debridement providing cutting, removalof Necrotic tissues (200-240 volts).3. Front panel Layout should have: illuminated power switch, Foot switch socket, Power Display, Foot switchconnection indicator, system fault indicator, power control, illuminated Green light Ring, Pump interface, key LockSymbol.5. It should have single use angled hand piece (15 degree) with a cutting window of 14mm (+/- 10 Percent) with high pressurecord and disposal tubing.6. It should have single use angled hand piece (45 degree) with a cutting window of 14mm (+/-10 Percent) with high pressurecord and disposal tubing.7. It should have an angled hand piece (45 degree) with a cutting window of 8 mm (+/- 10 Percent) with high pressure cordand disposal tubing. |
| 5 | Foot switch for above FOR HYDROSURGERY SYSTEM Foot switch pedal should be light weight (not more than 3lbs) and should have long cord ( 15ft) |
| 6 | handles for above It should have single use angled hand piece (15 degree) with a cutting window of 14mm (+/- 10 Percent) with high pressurecord and disposal tubing. |
| 7 | handles for above It should have single use angled hand piece (45 degree) with a cutting window of 14mm (+/- 10 Percent) with high pressurecord and disposal tubing. |
| 8 | handles for above It should have single use angled hand piece (45 degree) with a cutting window of 8mm (+/- 10 Percent) with high pressurecord and disposal tubing. |
| 9 | Micro Scissors, straight, sharp/sharp, 160 mm (6 1/4\\"), flat handle, cross serration, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 10 | Micro Scissors, curved, sharp/sharp, 160 mm (6 1/4\\"), flat handle, cross serration, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 11 | MOSQUITO (HARTMANN) Hemostatic Forceps, curved, 100 mm (4\\"), delicate, serrated, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 12 | METZENBAUM DUROTIP® Dissecting Scissors, curved, TC: yes, blunt/blunt, 145 mm (5 3/4\\"), Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 13 | MAYO DUROTIP® Dissecting Scissors, curved, TC: yes, heavy pattern, chamfered blades, blunt/blunt, 170 mm (6 3/4\\"), Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 14 | Tissue Forceps, straight, standard, 145 mm (5 3/4\\"), jaw width: 2.50 mm, 1 x 2 teeth, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 15 | Tissue Forceps, straight, standard, 200 mm (7 7/8\\"), jaw width: 3 mm, 1 x 2 teeth, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 16 | DE BAKEY ATRAUMATA® Atraumatic Forceps, straight, toothing DE BAKEY, 150 mm (6\\"), Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 17 | DE BAKEY ATRAUMATA® Atraumatic Forceps, straight, toothing DE BAKEY, 200 mm (7 7/8\\"), Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 18 | KOCHER Hemostatic Forceps, straight, 140 mm (5 1/2\\"), 1 x 2 teeth, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 19 | HALSTED (MOSQUITO) Hemostatic Forceps, curved, 125 mm (5\\"), delicate, serrated, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 20 | HALSTED Hemostatic Forceps, curved, 185 mm (7 1/4\\"), delicate, serrated, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 21 | MIKULICZ Peritoneum Forceps, curved, 200 mm (7 7/8\\"), 1 x 2 teeth, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 22 | OVERHOLT-GEISSENDOERFER Dissecting a. Ligature Forceps, curved, 220 mm (8 3/4\\"), serrated, Fig. 2, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 23 | BABY-MIXTER Dissecting a. Ligature Forceps, curved, 180 mm (7\\"), serrated, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 24 | BABCOCK Intestinal Grasping Forceps, straight, 155 mm (6 1/8\\"), non-sterile, reusable, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 25 | ALLIS ATRAUMATA® Intestinal Grasping Forceps, straight, 160 mm (6 1/4\\"), jaw: toothing DE BAKEY, jaw width: 6.20 mm, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 26 | MAYO-HEGAR DUROGRIP® Needle Holder, TC: yes, straight, 205 mm (8\\"), jaw: with 0.5 mm pitch of serration, for suture up to 3/0, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 27 | DE BAKEY DUROGRIP® Needle Holder, TC: yes, straight, 180 mm (7\\"), jaw: with 0.4 mm pitch of serration, for suture 4/0 - 6/0, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 28 | KOCHER-LANGENBECK Retractor, 215 mm (8 1/2\\"), depth: 55 mm, width: 11 mm, non-sterile, reusable, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 29 | VOLKMANN Retractor (Rake), 220 mm (8 3/4\\"), 4 prongs, jaw depth: 8.50 mm, jaw width: 19 mm, semi-sharp, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 30 | NELSON-METZENBAUM DUROTIP® Dissecting Scissors, curved, TC: yes, blunt/blunt, 260 mm (10 1/4\\"), Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 31 | RYDER DUROGRIP® Needle Holder, TC: yes, straight, very delicate, 175 mm (6 7/8\\"), Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 32 | DUROGRIP® Needle Holder, TC: yes, straight, very delicate, 200 mm (7 7/8\\"), Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 33 | DERRA ATRAUMATA® Vascular Clamp, angled, 55 °, 175 mm (6 7/8\\"), toothing DE BAKEY, width: 26 mm, for pediatrics, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 34 | DE BAKEY ATRAUMATA® Tangential Occlusion Clamp, angled, 60 °, 270 mm (10 5/8\\"), satinsky-shaped, toothing DE BAKEY, jaw length: 99 mm, width: 54 mm, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 35 | DE BAKEY ATRAUMATA® Vascular Clamp, angled, 60 °, 180 mm (7\\"), toothing DE BAKEY, jaw length: 65 mm, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 36 | CRILE Hemostatic Forceps, curved, 140 mm (5 1/2\\"), delicate, serrated, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 37 | METZENBAUM DUROTIP® Dissecting Scissors, curved, TC: yes, blunt/blunt, 200 mm (7 7/8\\"), Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 38 | KOCHER-OCHSNER Hemostatic Forceps, straight, 200 mm (7 7/8\\"), 1 x 2 teeth, Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 39 | CRILE-WOOD (BABY) DUROGRIP® Needle Holder, TC: yes, straight, 150 mm (6\\"), Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 40 | ADSON DUROGRIP® Dressing Forceps (Tweezers), TC: yes, straight, 120 mm (4 3/4\\"), jaw width: 1.20 mm, serrated (cross), Tungsten Crabide inlay should be nickel based & inlay should be welded to the instrument and not pasted ,Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402, it should be non magnetic , All instruments should adhere to following steel Composition: X46Cr13, X45CrMoV15 compulsory , All instruments should be supplied from single manufacturer |
| 41 | Organic highly refined Pre Padded Synthetic Splint Pre Padded Single Inter Locked knitted Slab of atleast 7 layers of Fiberglass, impregnated with Polyurethane Resin (Synthetic Substrate). Made with Inter Locking Performance(ILP Technology) for durable & Light weight splint with Double side 10cmX4.6mX1(Roll) ISO,CE AND USFDA APPROVED |
| 42 | Organic highly refined Pre Padded Synthetic Splint Pre Padded Single Inter Locked knitted Slab of atleast 7 layers of Fiberglass, impregnated with Polyurethane Resin (Synthetic Substrate). Made with Inter Locking Performance(ILP Technology) for durable & Light weight splint with Double side 12.5cmX4.6mX1(Roll) ISO,CE AND USFDA APPROVED |
| 43 | 3x4 Innovative Surgical Post Operative Dressing coated with Proprietary Dialkylcarbamoyl chloride (DACCTM) technology impregnated acetate tissue with absorbent pad and transparent film border. Hydrophobic interaction irreversibly binds bacteria and fungi rendering them inactive preventing toxin release and replication. Binds 108 bacteria within 2 hours even virulent bacteria like MRSA and VRE. With this technology no known cytotoxicity, resistance, and systemic absorption 6cmX20cm ISO,CE AND USFDA APPROVED |
| 44 | Anolyte strong formed from naturally occurring elements Water Resistant Padding with 3D spacer Knit Technology.Padding Fiber made of Polypropylene (80 Percent) Nylon (18 Percent) Polyester (2 Percent),Clear/white acrylic adhesive. 7.5cmX2.4m,7.5cmX10m |
| 45 | Is a sterile, hydrophobic microbe binding wound dressing. absorbs and retains exudate, thereby reducing the risk ofmaceration and enabling a moist wound environment.7cmX9cm |
| 46 | Is a sterile, hydrophobic microbe binding wound dressing. absorbs and retains exudate, thereby reducing the risk ofmaceration and enabling a moist wound environment.10cmX20cm |
| 47 | Dural substitute for dura replacement and extension of connective tissue in neuro and spine surgery. Dural substitute made up of bovine pericardium and bovine split hide compulsory. It should be used as onlay, Inlay and sutured (non-absorbable sutures) application. size:-Dura Substitute Dual layer Lyophilised Bovine pericardium and bovine split hide based, Absorbable Onlay and Suturable 2.5*2.5cm |
| 48 | Dural substitute for dura replacement and extension of connective tissue in neuro and spine surgery. Dural substitute made up of bovine pericardium and bovine split hide compulsory. It should be used as onlay, Inlay and sutured (non-absorbable sutures) application. size:- Dura Substitute Dual layer Lyophilised Bovine pericardium and bovine split hide based, Absorbable Onlay and Suturable 5.0*5.0cm |
| 49 | Dural substitute for dura replacement and extension of connective tissue in neuro and spine surgery. Dural substitute made up of bovine pericardium and bovine split hide compulsory. It should be used as onlay, Inlay and sutured (non-absorbable sutures) application. size:- Dura Substitute Dual layer Lyophilised Bovine pericardium and bovine split hide based, Absorbable Onlay and Suturable 7.5*2.5cm |
| 50 | Dural substitute for dura replacement and extension of connective tissue in neuro and spine surgery. Dural substitute made up of bovine pericardium and bovine split hide compulsory. It should be used as onlay, Inlay and sutured (non-absorbable sutures) application. size:- Dura Substitute Dual layer Lyophilised Bovine pericardium and bovine split hide based, Absorbable Onlay and Suturable 7.5*7.5cm |
| 51 | Dural substitute for dura replacement and extension of connective tissue in neuro and spine surgery. Dural substitute made up of bovine pericardium and bovine split hide compulsory. It should be used as onlay, Inlay and sutured (non-absorbable sutures) application. size:- Dura Substitute Dual layer Lyophilised Bovine pericardium and bovine split hide based, Absorbable Onlay and Suturable 10.0*12.5cm |
| 52 | Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible Implant must have integrated grasping jaw mechanism for shorter application time. Clamp size, 11mm, (Box of 12) |
| 53 | Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible Implant must have integrated grasping jaw mechanism for shorter application time. Clamp size, 16mm, (Box of 12) |
| 54 | Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible Implant must have integrated grasping jaw mechanism for shorter application time. Clamp size, 20mm, (Box of 12) |
| 55 | Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible Implant must have integrated grasping jaw mechanism for shorter application time. Clamp applier, non-dismountable, with automatic strain relief |
| 56 | Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible Implant must have integrated grasping jaw mechanism for shorter application time. Holding forcep |
| 57 | Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible Implant must have integrated grasping jaw mechanism for shorter application time. Pin Cutting instruments |
| 58 | Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible Implant must have integrated grasping jaw mechanism for shorter application time. Forcep to remove the clamps |
| 59 | Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible Implant must have integrated grasping jaw mechanism for shorter application time. Storage tray for all instruments |
| 60 | Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible Implant must have integrated grasping jaw mechanism for shorter application time. Bottom for ½ storage tray, height 90mm |
| 61 | Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible Implant must have integrated grasping jaw mechanism for shorter application time. ½ lid for storage container |
| 62 | Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible Implant must have integrated grasping jaw mechanism for shorter application time. Sterile instrument oil should be used to lubricate the instruments |
| 63 | Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible Implant must have integrated grasping jaw mechanism for shorter application time. All the instruments should be supplied from single manufacturer. |
| 64 | Digital Electronic System to stop life-threatening bleeding from a limb by tightly wrapping a band around it to cut off blood flow. They are also used in surgery to create a bloodless field for the surgeon Cuff Pressure Should be 0 to 600mmhg Pressure regulation should be +/- 2mmhg of set Point Console should be with 8” LCD Touch screen for Extensive & Easy operative experience.System Can be used for bilateral procedures. Online Pressure setting allows on line increase & Decrease of set pressure & set time even during the surgery.The Deflation should not be abrupt, it must be gradual. Errors must be shown for Cuff leakage detection, Tube Kinking and battery low. The digital electronic Tourniquet system must have patient optimized pressure technology to determine minimum pressure required to occlude the blood vessel. Different sizes of 90 degree angled port with positive interlocking connectors as mentioned below ; Single Port Straight Cuffs : 8”, 12”, 18”, 24”,34”Double Port straight Cuff : 18” Single Port Conical Cuff : 34” The Console must have the facility to print the data of the surgeries with its integrated printer in the console. ISO 13485 & CDSCO Approved – Ensuring Safety & Quality The Console works on 240VAC Power. |
| 65 | Imported Cuffs Compatible with multinational Standards Manufactured without the use of natural rubber latex & PVC free low profile designheavy duty TPU Bladder colour coded for optimal cuff selection straight shape & contour shape cuffs of different sizes available Single Port Straight Cuffs : 8” |
| 66 | Imported Cuffs Compatible with multinational Standards Manufactured without the use of natural rubber latex & PVC free low profile designheavy duty TPU Bladder colour coded for optimal cuff selection straight shape & contour shape cuffs of different sizes available Single Port Straight Cuffs : 12” |
| 67 | Imported Cuffs Compatible with multinational Standards Manufactured without the use of natural rubber latex & PVC free low profile designheavy duty TPU Bladder colour coded for optimal cuff selection straight shape & contour shape cuffs of different sizes available Single Port Straight Cuffs : , 18”, |
| 68 | Imported Cuffs Compatible with multinational Standards Manufactured without the use of natural rubber latex & PVC free low profile designheavy duty TPU Bladder colour coded for optimal cuff selection straight shape & contour shape cuffs of different sizes available Single Port Straight Cuffs : , 24”, |
| 69 | Imported Cuffs Compatible with multinational Standards Manufactured without the use of natural rubber latex & PVC free low profile designheavy duty TPU Bladder colour coded for optimal cuff selection straight shape & contour shape cuffs of different sizes available Single Port Straight Cuffs : ,34” |
| 70 | Imported Cuffs Compatible with multinational Standards Manufactured without the use of natural rubber latex & PVC free low profile designheavy duty TPU Bladder colour coded for optimal cuff selection straight shape & contour shape cuffs of different sizes available ”Double Port straight Cuff : 18 |
| 71 | Imported Cuffs Compatible with multinational Standards Manufactured without the use of natural rubber latex & PVC free low profile designheavy duty TPU Bladder colour coded for optimal cuff selection straight shape & contour shape cuffs of different sizes available Single Port Conical Cuff : 34” |
| 72 | Tubing :- Smooth surfaced connecting tubing autoclavable silicon material with positive locking connector Compatible with multinational Standards Manufactured without the use of natural rubber latex & PVC free low profile design heavy duty TPU Bladder colour coded for optimal WITH ALL cuff |
| 73 | PSGT TRAY MICRO INSTRUMENTS SPECIALITY TRAY OF 12 INSTRUMENTS The instruments should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 74 | PSGT TRAY MASTER INSTRUMENTS SPECIALITY TRAY OF 20 INSTRUMENTS The instruments should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 75 | PSGT TRAY ONLY FOR ABOVE INSTRUMENTS TO HANDLE ALL ABOVE INSTRUMENTS WITH ITS HANDLING MARKS WITH paper filter with indicator 225x225mm p/500 Aluminium Sterilization Container, complete: Botton silver, Colour of lid: silver, incl. paper filter. Extremely effective drying phase of the container interior, silicone sealings ensure long-term sterility, coloured lids and identification labels for better organization-290x290x100mm with EN 285: 2008 and validated acc to ISO 17665 Part1:2010 Sterilization wire baskets for containers, made of stainless steel, stackable, The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.should be light weight, strong and durable.IT should be non-magnetic should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All CONTAINERS adhere to steel Composition Chart. Certificate stating the same should be provided |
| 76 | SOLZ- FACE AND FOREHEAD LIFT TRAY MICRO INSTRUMENTS SPECIALITY TRAY OF 2 INSTRUMENTS The instruments should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 77 | SOLZ- FACE AND FOREHEAD LIFT TRAY MASTER INSTRUMENTS SPECIALITY TRAY OF 13 INSTRUMENTS The instruments should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 78 | SOLZ- FACE AND FOREHEAD LIFT TRAY ONLY FOR ABOVE INSTRUMENTS TO HANDLE ALL ABOVE INSTRUMENTS WITH ITS HANDLING MARKS WITH paper filter with indicator 225x225mm p/500 Aluminium Sterilization Container, complete: Botton silver, Colour of lid: silver, incl. paper filter. Extremely effective drying phase of the container interior, silicone sealings ensure long-term sterility, coloured lids and identification labels for better organization-290x290x100mm with EN 285: 2008 and validated acc to ISO 17665 Part1:2010 Sterilization wire baskets for containers, made of stainless steel, stackable, The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.should be light weight, strong and durable.IT should be non-magnetic should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All CONTAINERS adhere to steel Composition Chart. Certificate stating the same should be provided |
| 79 | KOSHI MIS TRAY MICRO INSTRUMENTS SPECIALITY TRAY OF 5 INSTRUMENTS The instruments should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 80 | KOSHI MIS TRAY MASTER INSTRUMENTS SPECIALITY TRAY OF 5 INSTRUMENTS The instruments should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 81 | KOSHI MIS TRAY ONLY FOR ABOVE INSTRUMENTS TO HANDLE ALL ABOVE INSTRUMENTS WITH ITS HANDLING MARKS WITH paper filter with indicator 225x225mm p/500 Aluminium Sterilization Container, complete: Botton silver, Colour of lid: silver, incl. paper filter. Extremely effective drying phase of the container interior, silicone sealings ensure long-term sterility, coloured lids and identification labels for better organization-290x290x100mm with EN 285: 2008 and validated acc to ISO 17665 Part1:2010 Sterilization wire baskets for containers, made of stainless steel, stackable, The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.should be light weight, strong and durable.IT should be non-magnetic should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All CONTAINERS adhere to steel Composition Chart. Certificate stating the same should be provided |
| 82 | SUPER MICRO PSGT TRAY MICRO INSTRUMENTS SPECIALITY TRAY OF 22 INSTRUMENTS The instruments should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 83 | SUPER MICRO PSGT MASTER INSTRUMENTS SPECIALITY TRAY OF 2 INSTRUMENTS The instruments should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN __ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 84 | SUPER MICRO PSGT TRAY ONLY FOR ABOVE INSTRUMENTS TO HANDLE ALL ABOVE INSTRUMENTS WITH ITS HANDLING MARKS WITH paper filter with indicator 225x225mm p/500 Aluminium Sterilization Container, complete: Botton silver, Colour of lid: silver, incl. paper filter. Extremely effective drying phase of the container interior, silicone sealings ensure long-term sterility, coloured lids and identification labels for better organization-290x290x100mm with EN 285: 2008 and validated acc to ISO 17665 Part1:2010 Sterilization wire baskets for containers, made of stainless steel, stackable, The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.should be light weight, strong and durable.IT should be non-magnetic should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All CONTAINERS adhere to steel Composition Chart. Certificate stating the same should be provided |
| 85 | BLEPHARO PSGT TRAY MICRO INSTRUMENTS SPECIALITY TRAY OF 3 INSTRUMENTS The instruments should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 86 | BLEPHARO PSGT MASTER INSTRUMENTS SPECIALITY TRAY OF 12 INSTRUMENTS The instruments should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 87 | BLEPHARO PSGT TRAY ONLY FOR ABOVE INSTRUMENTS TO HANDLE ALL ABOVE INSTRUMENTS WITH ITS HANDLING MARKS WITH paper filter with indicator 225x225mm p/500 Aluminium Sterilization Container, complete: Botton silver, Colour of lid: silver, incl. paper filter. Extremely effective drying phase of the container interior, silicone sealings ensure long-term sterility, coloured lids and identification labels for better organization-290x290x100mm with EN 285: 2008 and validated acc to ISO 17665 Part1:2010 Sterilization wire baskets for containers, made of stainless steel, stackable, The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.should be light weight, strong and durable.IT should be non-magnetic should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All CONTAINERS adhere to steel Composition Chart. Certificate stating the same should be provided |
| 88 | MAMMA PSGT TRAY MICRO INSTRUMENTS SPECIALITY TRAY OF 4 INSTRUMENTS The instruments should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 89 | MAMMA PSGT MASTER INSTRUMENTS SPECIALITY TRAY OF 17 INSTRUMENTS The instruments should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 90 | ABDOMINO- Solz TRAY MICRO INSTRUMENTS SPECIALITY TRAY OF 6 INSTRUMENTS The instruments should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 91 | MAMMA PSGT MASTER INSTRUMENTS SPECIALITY TRAY OF 23 INSTRUMENTS The instruments should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 92 | MAMMA PSGT TRAY ONLY FOR ABOVE INSTRUMENTS TO HANDLE ALL ABOVE INSTRUMENTS WITH ITS HANDLING MARKS WITH paper filter with indicator 225x225mm p/500 Aluminium Sterilization Container, complete: Botton silver, Colour of lid: silver, incl. paper filter. Extremely effective drying phase of the container interior, silicone sealings ensure long-term sterility, coloured lids and identification labels for better organization-290x290x100mm with EN 285: 2008 and validated acc to ISO 17665 Part1:2010 Sterilization wire baskets for containers, made of stainless steel, stackable, The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.should be light weight, strong and durable.IT should be non-magnetic should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All CONTAINERS adhere to steel Composition Chart. Certificate stating the same should be provided |
| 93 | Micro SET for Anastomosis TRAY MICRO INSTRUMENTS SPECIALITY TRAY OF 21 INSTRUMENTS The instruments should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 94 | Micro SET for Anastomosis MASTER INSTRUMENTS SPECIALITY TRAY OF 3 INSTRUMENTS The instruments should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 95 | Micro SET for Anastomosis TRAY ONLY FOR ABOVE INSTRUMENTS TO HANDLE ALL ABOVE INSTRUMENTS WITH ITS HANDLING MARKS WITH paper filter with indicator 225x225mm p/500 Aluminium Sterilization Container, complete: Botton silver, Colour of lid: silver, incl. paper filter. Extremely effective drying phase of the container interior, silicone sealings ensure long-term sterility, coloured lids and identification labels for better organization-290x290x100mm with EN 285: 2008 and validated acc to ISO 17665 Part1:2010 Sterilization wire baskets for containers, made of stainless steel, stackable, The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.should be light weight, strong and durable.IT should be non-magnetic should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All CONTAINERS adhere to steel Composition Chart. Certificate stating the same should be provided |
| 96 | LIP SET for suction pump only should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 97 | LIP SET for suction handle with tube connection only should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 98 | LIP SET for Mercedes l cannula 15cm Ø 4mm handle connection should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 99 | LIP SET facial contours (Facial Area) only should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 100 | LIP SET Entner suction cannula straight 18 holes handle connection should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 101 | LIP SET TRAY ONLY FOR ABOVE INSTRUMENTS TO HANDLE ALL ABOVE INSTRUMENTS WITH ITS HANDLING MARKS WITH paper filter with indicator 225x225mm p/500 Aluminium Sterilization Container, complete: Botton silver, Colour of lid: silver, incl. paper filter. Extremely effective drying phase of the container interior, silicone sealings ensure long-term sterility, coloured lids and identification labels for better organization-290x290x100mm with EN 285: 2008 and validated acc to ISO 17665 Part1:2010 Sterilization wire baskets for containers, made of stainless steel, stackable, The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.should be light weight, strong and durable.IT should be non-magnetic should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All CONTAINERS adhere to steel Composition Chart. Certificate stating the same should be provided |
| 102 | FAT INJ SET TRAY MICRO INSTRUMENTS SPECIALITY TRAY OF INSTRUMENTS The instruments should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 103 | FAT INJ SET TRAY ONLY FOR ABOVE INSTRUMENTS TO HANDLE ALL ABOVE INSTRUMENTS WITH ITS HANDLING MARKS WITH paper filter with indicator 225x225mm p/500 Aluminium Sterilization Container, complete: Botton silver, Colour of lid: silver, incl. paper filter. Extremely effective drying phase of the container interior, silicone sealings ensure long-term sterility, coloured lids and identification labels for better organization-290x290x100mm with EN 285: 2008 and validated acc to ISO 17665 Part1:2010 Sterilization wire baskets for containers, made of stainless steel, stackable, The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.should be light weight, strong and durable.IT should be non-magnetic should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All CONTAINERS adhere to steel Composition Chart. Certificate stating the same should be provided |
| 104 | GUBISCH Rhino TRAY MICRO INSTRUMENTS SPECIALITY TRAY OF INSTRUMENTS The instruments should be made of high grade stainless steel. The quality of steel should comply with the DIN, US-FDA, European CE and EN ISO 13485 standards.The instruments should be of high quality and precision. The instruments should be light weight, strong and durable.The instruments should be non-magnetic The instruments should be autoclavable at 134° C and follow international US-FDA and EN ISO norms for sterilization. The Tungsten Carbide inlay should be nickel based Tungsten carbide should be welded to the instrument and not pasted. Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer Bidder Must Quote All Items Of instruments Sets from the Same Manufacturer The Manufacturer /subsidary should have a Authorized direct repair facility available in India A confirmation that the Instruments should have gone through a Passivation Process with detailed certification for the same. Each instrument should have the following information embossed on it a) Article Number , b) Country of Origin. \\"MADE IN _ (country Name). c) Manufacturers Name. d) Lot number should be mentioned on every instrument Country of origin certificate should be provided on demand TUV certificate of manufacturer should be provided warranty against all manufacturing defects and faulty workmanship All instruments adhere to steel Composition Chart. Certificate stating the same should be provided |
| 105 | CE approved wound closer device with pre filled syringe of N Butyl - 2 - Cynoacrylate. |
| 106 | OT Sterilization System and it should be photocatalytic oxidation technology, ensure surface sterilization and whenever SWAB Test is done it exhibit no Growth. It offers air quality index with sound of less than 30 decibel. It should cover 500 Sq ft with height of 10 ft. |
| 107 | bioengineered mimic Artificial bi-layered Implant neuro - Size: 50MM usfda & CE approved |
| 108 | bioengineered mimic Artificial bi-layered Implant neuro - Size: 60MM usfda & CE approved |
| 109 | bioengineered mimic Artificial bi-layered Implant neuro - Size: 100MM usfda & CE approved |
| 110 | bioengineered mimic Artificial bi-layered Implant neuro - Size: 200MM usfda & CE approved |
| 111 | SNPWT small portable sterile Pump with 4 indicators . The pack must contain 2 sterile packs of dressing pad with high MVTR rate with 80 PErcent evaporation and 20 PErcent retention of moisture vapour. Dressing pack with extra eight sucurement stripes in each sterile pack . must be with four layers -Silicon adhesive wound contact layer, AIRLOCK Technology Layer ,Highly absorbent Layer and semipermeable top polymer film .The Pump must be single use with 7 days .USFDA AND CE APPROVED SIZE - 15CM x30 cm |
| 112 | SNPWT small portable sterile Pump with 4 indicators . The pack must contain 2 sterile packs of dressing pad with high MVTR rate with 80 PErcent evaporation and 20 PErcent retention of moisture vapour. Dressing pack with extra eight sucurement stripes in each sterile pack . must be with four layers -Silicon adhesive wound contact layer, AIRLOCK Technology Layer ,Highly absorbent Layer and semipermeable top polymer film .The Pump must be single use with 7 days .USFDA AND CE APPROVED SIZE - 15CM x20 cm |
| 113 | SNPWT small portable sterile Pump with 4 indicators . The pack must contain 2 sterile packs of dressing pad with high MVTR rate with 80 PErcent evaporation and 20 PErcent retention of moisture vapour. Dressing pack with extra eight sucurement stripes in each sterile pack . must be with four layers -Silicon adhesive wound contact layer, AIRLOCK Technology Layer ,Highly absorbent Layer and semipermeable top polymer film .The Pump must be single use with 7 days .USFDA AND CE APPROVED SIZE - 20CM x20 cm |
| 114 | SNPWT small portable sterile Pump with 4 indicators . The pack must contain 2 sterile packs of dressing pad with high MVTR rate with 80 PErcent evaporation and 20 PErcent retention of moisture vapour. Dressing pack with extra eight sucurement stripes in each sterile pack . must be with four layers -Silicon adhesive wound contact layer, AIRLOCK Technology Layer ,Highly absorbent Layer and semipermeable top polymer film .The Pump must be single use with 7 days .USFDA AND CE APPROVED SIZE - 25CM x25 cm |
| 115 | SNPWT small portable sterile Pump with 4 indicators . The pack must contain 2 sterile packs of dressing pad with high MVTR rate with 80 PErcent evaporation and 20 PErcent retention of moisture vapour. Dressing pack with extra eight sucurement stripes in each sterile pack . must be with four layers -Silicon adhesive wound contact layer, AIRLOCK Technology Layer ,Highly absorbent Layer and semipermeable top polymer film .The Pump must be single use with 14 days .USFDA AND CE APPROVED SIZE - 10CM x20 cm |
| 116 | SNPWT small portable sterile Pump with 4 indicators . The pack must contain 2 sterile packs of dressing pad with high MVTR rate with 80 PErcent evaporation and 20 PErcent retention of moisture vapour. Dressing pack with extra eight sucurement stripes in each sterile pack . must be with four layers -Silicon adhesive wound contact layer, AIRLOCK Technology Layer ,Highly absorbent Layer and semipermeable top polymer film .The Pump must be single use with 14 days .USFDA AND CE APPROVED SIZE - 10CM x30 cm |
| 117 | SNPWT small portable sterile Pump with 4 indicators . The pack must contain 2 sterile packs of dressing pad with high MVTR rate with 80 PErcent evaporation and 20 PErcent retention of moisture vapour. Dressing pack with extra eight sucurement stripes in each sterile pack . must be with four layers -Silicon adhesive wound contact layer, AIRLOCK Technology Layer ,Highly absorbent Layer and semipermeable top polymer film .The Pump must be single use with 14 days .USFDA AND CE APPROVED SIZE - 10CM x40 cm |
| 118 | SNPWT small portable sterile Pump with 4 indicators . The pack must contain 2 sterile packs of dressing pad with high MVTR rate with 80 PErcent evaporation and 20 PErcent retention of moisture vapour. Dressing pack with extra eight sucurement stripes in each sterile pack . must be with four layers -Silicon adhesive wound contact layer, AIRLOCK Technology Layer ,Highly absorbent Layer and semipermeable top polymer film .The Pump must be single use with 14 days .USFDA AND CE APPROVED SIZE - 15CM x15 cm |
| 119 | SNPWT small portable sterile Pump with 4 indicators . The pack must contain 2 sterile packs of dressing pad with high MVTR rate with 80 PErcent evaporation and 20 PErcent retention of moisture vapour. Dressing pack with extra eight sucurement stripes in each sterile pack . must be with four layers -Silicon adhesive wound contact layer, AIRLOCK Technology Layer ,Highly absorbent Layer and semipermeable top polymer film .The Pump must be single use with 14 days .USFDA AND CE APPROVED SIZE - 15CM x30 cm |
| 120 | SNPWT small portable sterile Pump with 4 indicators . The pack must contain 2 sterile packs of dressing pad with high MVTR rate with 80 PErcent evaporation and 20 PErcent retention of moisture vapour. Dressing pack with extra eight sucurement stripes in each sterile pack . must be with four layers -Silicon adhesive wound contact layer, AIRLOCK Technology Layer ,Highly absorbent Layer and semipermeable top polymer film .The Pump must be single use with 14 days .USFDA AND CE APPROVED SIZE - 15CM x20 cm |
| 121 | SNPWT small portable sterile Pump with 4 indicators . The pack must contain 2 sterile packs of dressing pad with high MVTR rate with 80 PErcent evaporation and 20 PErcent retention of moisture vapour. Dressing pack with extra eight sucurement stripes in each sterile pack . must be with four layers -Silicon adhesive wound contact layer, AIRLOCK Technology Layer ,Highly absorbent Layer and semipermeable top polymer film .The Pump must be single use with 14 days .USFDA AND CE APPROVED SIZE - 20CM x20 cm |
| 122 | SNPWT small portable sterile Pump with 4 indicators . The pack must contain 2 sterile packs of dressing pad with high MVTR rate with 80 PErcent evaporation and 20 PErcent retention of moisture vapour. Dressing pack with extra eight sucurement stripes in each sterile pack . must be with four layers -Silicon adhesive wound contact layer, AIRLOCK Technology Layer ,Highly absorbent Layer and semipermeable top polymer film .The Pump must be single use with 14 days .USFDA AND CE APPROVED SIZE - 25CM x25 cm |
| 123 | Soft port pad with integrated filter with extension attached tubing desinged with integreted filter to prevent liquid ingress into the soft port tubing with 80 PErcent exudate evaporation technique compatable with 7/14 days Single use NPWT disposable pump , CE/USFDA APPROVED, PACK OF 5 PADS size 10cm x20 cm |
| 124 | Soft port pad with integrated filter with extension attached tubing desinged with integreted filter to prevent liquid ingress into the soft port tubing with 80 PErcent exudate evaporation technique compatable with 7/14 days Single use NPWT disposable pump , CE/USFDA APPROVED, PACK OF 5 PADS size 10cm x30 cm |
| 125 | Soft port pad with integrated filter with extension attached tubing desinged with integreted filter to prevent liquid ingress into the soft port tubing with 80 PErcent exudate evaporation technique compatable with 7/14 days Single use NPWT disposable pump , CE/USFDA APPROVED, PACK OF 5 PADS size 10cm x40 cm |
| 126 | Soft port pad with integrated filter with extension attached tubing desinged with integreted filter to prevent liquid ingress into the soft port tubing with 80 PErcent exudate evaporation technique compatable with 7/14 days Single use NPWT disposable pump , CE/USFDA APPROVED, PACK OF 5 PADS size 15cm x20 cm |
| 127 | Soft port pad with integrated filter with extension attached tubing desinged with integreted filter to prevent liquid ingress into the soft port tubing with 80 PErcent exudate evaporation technique compatable with 7/14 days Single use NPWT disposable pump , CE/USFDA APPROVED, PACK OF 5 PADS size 15cm x30 cm |
| 128 | Soft port pad with integrated filter with extension attached tubing desinged with integreted filter to prevent liquid ingress into the soft port tubing with 80 PErcent exudate evaporation technique compatable with 7/14 days Single use NPWT disposable pump , CE/USFDA APPROVED, PACK OF 5 PADS size 20cm x20 cm |
| 129 | Soft port pad with integrated filter with extension attached tubing desinged with integreted filter to prevent liquid ingress into the soft port tubing with 80 PErcent exudate evaporation technique compatable with 7/14 days Single use NPWT disposable pump , CE/USFDA APPROVED, PACK OF 5 PADS size 25cm x25 cm |
| 130 | Soft port pad with integrated filter with extension attached tubing desinged with integreted filter to prevent liquid ingress into the soft port tubing with 80 PErcent exudate evaporation technique compatable with 7/14 days Single use NPWT disposable pump , CE/USFDA APPROVED, PACK OF 5 PADS size 15cm x15 cm |
| 131 | Soft port pad with integrated filter with extension attached tubing desinged with integreted filter to prevent liquid ingress into the soft port tubing with 80 PErcent exudate evaporation technique compatable with 7/14 days Single use NPWT disposable pump , CE/USFDA APPROVED, PACK OF 5 PADS size 20cm x25 cm |
| 132 | Hydrosurgical debridement hand pieces which must work on barnauli principal and venturi effect with single use disposal with size 45degree / 14 mm,USFDA/CE APPROVED |
| 133 | Hydrosurgical debridement hand pieces which must work on barnauli principal and venturi effect with single use disposal with size 45degree / 8 mm,USFDA/CE APPROVED |
| 134 | Hydrosurgical debridement hand pieces which must work on barnauli principal and venturi effect with single use disposal with size 15degree / 14 mm,USFDA/CE APPROVED |
| 135 | Single use hand piece with with higher deck height with 0.10 mm nozzle orifice and wider channel with angle of 45degree and 14mm |
| 136 | Single use hand piece with with higher deck heigh with 0.10 mm nozzle orifice and wider channel with angle of 45degree and 8mm |
| 137 | Single use hand piece with with higher deck height with 0.10 mm nozzle orifice and wider channel with angle of 15degree and 14mm |
| 138 | hand piece with tubing and drain pipe which enable the precise excision at a minimum depth of 50 micro meters 14 mm 45* |
| 139 | hand piece with tubing and drain pipe which enable the precise excision at a minimum depth of 50 micro meters 8 mm 45* |
| 140 | hand piece with tubing and drain pipe which enable the precise excision at a minimum depth of 50 micro meters 15degree 15* |
| 141 | low adherent perforated film with rayon fibres and bleached cotton with outer hydrophobic layer One side ruff and other side Wound contact layer is Shining side Non Adherant size : 10cm x 10 cm USFDA /CE |
| 142 | low adherent perforated film with rayon fibres and bleached cotton with outer hydrophobic layer One side ruff and other side Wound contact layer is Shining side Non Adherant size : 20cm x 10 cm USFDA /CE |
| 143 | biosynthetic gloves shape wound dressing constructed of a silicone film bonded to a cross linked porcine collagen coated nylon fabric. A non toxic mixture of highly purified peptides derived from porcine dermal collagen has been bonded to the nylon/silicone membrane to provide a highly flexible and conformable composite dressing. The semi permeable silicone membrane controls water vapour loss at rates comparable to normal skin. It helps to minimize dead space on the wound surface and minimises the proliferation of bacteria. It is transparent and allows for visualisationof the wound site. Size - Medium gloves |
| 144 | biosynthetic gloves shape wound dressing constructed of a silicone film bonded to a cross linked porcine collagen coated nylon fabric. A non toxic mixture of highly purified peptides derived from porcine dermal collagen has been bonded to the nylon/silicone membrane to provide a highly flexible and conformable composite dressing. The semi permeable silicone membrane controls water vapour loss at rates comparable to normal skin. It helps to minimize dead space on the wound surface and minimises the proliferation of bacteria. It is transparent and allows for visualisationof the wound site. Size - Large GLOVES |
| 145 | biosynthetic wound dressing constructed of a silicone film bonded to a cross linked porcine collagen coated nylon fabric. A non toxic mixture of highly purified peptides derived from porcine dermal collagen has been bonded to the nylon/silicone membrane to provide a highly flexible and conformable composite dressing. The semi permeable silicone membrane controls water vapour loss at rates comparable to normal skin. It helps to minimize dead space on the wound surface and minimises the proliferation of bacteria. It is transparent and allows for visualisationof the wound site. Size 25 x38 cm |
| 146 | biosynthetic wound dressing constructed of a silicone film bonded to a cross linked porcine collagen coated nylon fabric. A non toxic mixture of highly purified peptides derived from porcine dermal collagen has been bonded to the nylon/silicone membrane to provide a highly flexible and conformable composite dressing. The semi permeable silicone membrane controls water vapour loss at rates comparable to normal skin. It helps to minimize dead space on the wound surface and minimises the proliferation of bacteria. It is transparent and allows for visualisationof the wound site. Size 38 x 50 cm |
| 147 | Sterile, semipermeable, transparent, breathable, water proof, bacterial and viral barrier polyurethane film (that reduces chance of infection) with absorbent, non-adherent pad (that helps reduce trauma on dressing removal) and latex free hypoallergenic acrylic adhesive that is gentle to skin. It is strachable for easy application. Size 6.5cmX.5cm |
| 148 | Sterile, semipermeable, transparent, breathable, water proof, bacterial and viral barrier polyurethane film (that reduces chance of infection) with absorbent, non-adherent pad (that helps reduce trauma on dressing removal) and latex free hypoallergenic acrylic adhesive that is gentle to skin. It is strachable for easy application. Size 9.5cmX8.5cm |
| 149 | Sterile, semipermeable, transparent, breathable, water proof, bacterial and viral barrier polyurethane film (that reduces chance of infection) with absorbent, non-adherent pad (that helps reduce trauma on dressing removal) and latex free hypoallergenic acrylic adhesive that is gentle to skin. It is strachable for easy application. Size 15.5cmx 8.5cm |
| 150 | Sterile, semipermeable, transparent, breathable, water proof, bacterial and viral barrier polyurethane film (that reduces chance of infection) with absorbent, non-adherent pad (that helps reduce trauma on dressing removal) and latex free hypoallergenic acrylic adhesive that is gentle to skin. It is strachable for easy application. Size 20cmX 10 cm |
| 151 | Sterile, semipermeable, transparent, breathable, water proof, bacterial and viral barrier polyurethane film (that reduces chance of infection) with absorbent, non-adherent pad (that helps reduce trauma on dressing removal) and latex free hypoallergenic acrylic adhesive that is gentle to skin. It is strachable for easy application. Size 25cmX 10 cm |
| 152 | Sterile, semipermeable, transparent, breathable, water proof, bacterial and viral barrier polyurethane film (that reduces chance of infection) with absorbent, non-adherent pad (that helps reduce trauma on dressing removal) and latex free hypoallergenic acrylic adhesive that is gentle to skin. It is strachable for easy application. Size 30cmX 10 cm |
| 153 | Sterile, semipermeable, transparent, breathable, water proof, bacterial and viral barrier polyurethane film (that reduces chance of infection) with absorbent, non-adherent pad (that helps reduce trauma on dressing removal) and latex free hypoallergenic acrylic adhesive that is gentle to skin. It is strachable for easy application. Size 35cmX 10 cm |
| 154 | Non - fraying ,Tulle Gras Paraffin Gauze dressing with leno weave technology which gives a soothing effect and protection to the wound 15cm x 2mtr Roll |
| 155 | Low adherent absorbent wound dressing with a polyester perforated wound contact layer with an outer hydrophobic non-woven layer which is highly conformable and can be cut to shape, shows delayed risk of exudate strike-through to the outer dressing surface, low risk of fibre shredding for new tissue cell growth in the wound size 50cm x 7mtr |
| 156 | Antimicrobial barrier dressing with Silcryst technology Nanocrystals Silver consisting of a rayon/polyester non- woven core laminated (by sonic welds) between an upper & lower layer of nanocrystalline silver coated high density polyethylene mesh which releases 70-100ppm of silver continuously for 72 hours. 10cm x120cm |
| 157 | Antimicrobial barrier dressing with Silcryst technology Nanocrystals Silver consisting of a rayon/polyester non- woven core laminated (by sonic welds) between an upper & lower layer of nanocrystalline silver coated high density polyethylene mesh which releases 70-100ppm of silver continuously for 72 hours. 10cm x10cm |
| 158 | Antimicrobial barrier dressing with Silcryst technology Nanocrystals Silver consisting of a rayon/polyester non- woven core laminated (by sonic welds) between an upper & lower layer of nanocrystalline silver coated high density polyethylene mesh which releases 70-100ppm of silver continuously for 72 hours. 20cm x40cm |
| 159 | Triple layered non-adhesive hydrocellular foam dressing for superior fluid handling through unique dressing reconstruction with a breathable pink coloured polyurethane film, middle layer is a highly absorbent hydrocellular foam and a perforated non-adherent wound contact layer which prevents healing tissue from growing into the dressing minimizing pain on removal.size 10cm x 10cm |
| 160 | Triple layered non-adhesive hydrocellular foam dressing for superior fluid handling through unique dressing reconstruction with a breathable pink coloured polyurethane film, middle layer is a highly absorbent hydrocellular foam and a perforated non-adherent wound contact layer which prevents healing tissue from growing into the dressing minimizing pain on removal. size 20cm x 20cm |
| 161 | Moisture responsive ported catheter dressing with high moisture vapour transmission rate (3000-1000gm/sq m at 37 degree celsius for 24hrs) made up of transparent, bacteriaproof, reactive polyurethane film consisting of patented grid pattern with low allergy water based acrylic adhesive only on 75 Percent of the dressing for easy application, removal & reducation in lateral migration. 10cm x14cm |
| 162 | Medicated,Non - fraying ,Tulle Gras Paraffin Gauze dressing with leno weave technology containing Chlorhexidine Acetate (0.5 Percent) which is a broad spectrum antiseptic active against Gram positive & Gram negative bacteria and which gives a soothing effect and protection to the wound. 10cm x 10cm Pouch |
| 163 | Medicated,Non - fraying ,Tulle Gras Paraffin Gauze dressing with leno weave technology containing Chlorhexidine Acetate (0.5 Percent) which is a broad spectrum antiseptic active against Gram positive & Gram negative bacteria and which gives a soothing effect and protection to the wound. 10cm x 10cm Tin of 10 deressings |
| 164 | Medicated,Non - fraying ,Tulle Gras Paraffin Gauze dressing with leno weave technology containing Chlorhexidine Acetate (0.5 Percent) which is a broad spectrum antiseptic active against Gram positive & Gram negative bacteria and which gives a soothing effect and protection to the wound. 10cm x 30cm |
| 165 | Medicated,Non - fraying ,Tulle Gras Paraffin Gauze dressing with leno weave technology containing Chlorhexidine Acetate (0.5 Percent) which is a broad spectrum antiseptic active against Gram positive & Gram negative bacteria and which gives a soothing effect and protection to the wound. 15cm x 1m Roll |
| 166 | An advanced triple-layer construction which combines an absorbent hydrocellular pad sandwiched between a perforated Soft Gel adhesive wound contact layer and a highly permeable waterproof outer film. Triple-action technology absorbs, retains, and transpires exudate to provide optimal fluid management.Maintains optimal moisture balance - Provides an optimal moist wound environment for the promotion of faster healing. Comes off lightly - Gentle adhesive allows less painful dressing changes Easier application - Gel adhesive holds the dressing in Size 10x20 cm |
| 167 | An advanced triple-layer construction which combines an absorbent hydrocellular pad sandwiched between a perforated Soft Gel adhesive wound contact layer and a highly permeable waterproof outer film. Triple-action technology absorbs, retains, and transpires exudate to provide optimal fluid management.Maintains optimal moisture balance - Provides an optimal moist wound environment for the promotion of faster healing. Comes off lightly - Gentle adhesive allows less painful dressing changes Easier application - Gel adhesive holds the dressing in Size 10 x25 cm |
| 168 | An advanced triple-layer construction which combines an absorbent hydrocellular pad sandwiched between a perforated Soft Gel adhesive wound contact layer and a highly permeable waterproof outer film. Triple-action technology absorbs, retains, and transpires exudate to provide optimal fluid management.Maintains optimal moisture balance - Provides an optimal moist wound environment for the promotion of faster healing. Comes off lightly - Gentle adhesive allows less painful dressing changes Easier application - Gel adhesive holds the dressing in Size 10 x30 cm |
| 169 | Transparent Film RollThin polyurethane film with high MVTR Film is waterproot and aids in the prevention of bacterial contamination. Low allergy water based acrylic adhesive that minimizes the risk of skinirritation or sensitivity.The film is highly conformable and extensible to fit to awkward dressing areas.The uniique and novel roll format enables rapid and economical use.Available as 10cm x 10m. |
| 170 | Transparent Film RollThin polyurethane film with high MVTR Film is waterproot and aids in the prevention of bacterial contamination. Low allergy water based acrylic adhesive that minimizes the risk of skinirritation or sensitivity.The film is highly conformable and extensible to fit to awkward dressing areas.The uniique and novel roll format enables rapid and economical use.Available as 5cm x 10m. |
| 171 | Monofilament Poly-4-Hydroxy Butyrate biosynthetic homopolymer(Hydrolysed & degraded via Kreb cycle) Cyanoacrylate Tissue AdhesiveLiquid n-butyl-2-cyanoacrylate closure up to 7CM in the pack |
| 172 | Monofilament Poly-4-Hydroxy Butyrate biosynthetic homopolymer(Hydrolysed & degraded via Kreb cycle) Cyanoacrylate Tissue AdhesiveLiquid n-butyl-2-cyanoacrylate closure up to 25CM in the pack |
| 173 | Monofilament Poly-4-Hydroxy Butyrate biosynthetic homopolymer(Hydrolysed & degraded via Kreb cycle) Absorbable Hemostat KHV 5X8CM Compress from nature collagen of bovine origin European CE approved with pack size of 6 is used for hemostasis of capillary bleeding, oozing hemorrhages, bleeding of parenchymal organs and as a supportive measure for other hemostasis techniques |
| 174 | Monofilament Poly-4-Hydroxy Butyrate biosynthetic homopolymer(Hydrolysed & degraded via Kreb cycle) Absorbable Hemostat KHV 10X12CM Compress from nature collagen of bovine origin European CE approved with pack size of 4 Lyostypt® is used for hemostasis of capillary bleeding, oozing hemorrhages, bleeding of parenchymal organs and as a supportive measure for other hemostasis techniques |
| 175 | Lid• Should be made of PEEK & Stainless Steel.• Should have quick locking facility.Sterile FunnelShould be made of PEEK. |
| 176 | TAYLOR Retractor, 200 mm (7 7/8\\"), depth: 30 mm, width: 100 mm, non-sterile, reusable, silver mat surface, X20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 177 | WEITLANER Retractor (Self Retaining), 130 mm (5 1/8\\"), 3 x 4 prongs, blunt, non-sterile, reusable, silver mat surface,X20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 178 | BECKMANN-ADSON Retractor (Self Retaining), with joint, 310 mm (12 1/4\\"), 4 x 4 prongs, semi-sharp, with ratchet, non-sterile, reusable, silver mat surface,X20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 179 | CLOWARD (MODIF.) Wound Retractor, complete retractor, 185 mm (7 1/4\\"), consisting of Self Retaining Spreader with 5 Blades, non-sterile, reusable, silver mat surface.X20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 180 | GERALD Micro Forceps, straight, 180 mm (7\\"), toothing DE BAKEY, flat handle, width: 1 mm, non-sterile, reusable,X20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 181 | Micro scissors, curved, 180 mm (7\\"), sharp/sharp blade, round handle, Golf ball design handle, non-sterile, reusable, silk mat surface.X20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 182 | DIAMOND DUST Micro Needle Holder, straight, 185 mm (7 1/4\\"), spring type, round handle, with ratchet, diamond dust coated, suture up to 5/0, non-sterile, reusableX20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 183 | METZENBAUM DUROTIP Tungsten Carbide Dissecting Scissors, curved, 180 mm (7\\"), delicate pattern, blunt/blunt, non-sterile, reusable, silk mat surface.X20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 184 | METZENBAUM DUROTIP Tungsten Carbide Dissecting Scissors, curved, 230 mm (9\\"), delicate pattern, blunt/blunt, non-sterile, reusable, silk mat surfaceX20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 185 | HEGAR-MAYO DUROGRIP Tungsten Carbide Needle holder, straight, 150 mm (6\\"), with 0.5 mm pitch of serration, suture up to 3/0, non-sterile, reusable, silver mat surfaceX20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 186 | HEGAR-MAYO DUROGRIP Tungsten Carbide Needle holder, straight, 205 mm (8\\"), with 0.5 mm pitch of serration, suture up to 3/0, non-sterile, reusable, silver mat surfaceX20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 187 | KILNER DUROGRIP Tungsten Carbide Needle holder, straight, 135 mm (5 1/4\\"), bayonet-shaped, with 0.5 mm pitch of serration, suture up to 3/0, non-sterile, reusable, silver mat surfaceX20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 188 | ECHLIN Bone Rongeur, angled to side, 230 mm (9\\"), double action, and jaw length: 10 mm, jaw width: 2 mm, silver mat surface.X20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 189 | ECHLIN Bone Rongeur, angled to side, 230 mm (9\\"), double action, and jaw length: 10 mm, jaw width: 3 mm, silver mat surface.X20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 190 | DIAMOND DUST MICRO NEEDLE HOLDER RD HDL 210MM, X20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 191 | DIAMOND DUST MICRO NEEDLE HOLDER RD HDL 230MM X20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 192 | DUROGRIP NDL HLDR SERR 0.2/180MMX20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 193 | DIAMOND DUST MIC NDL HDL FLAT HANDLE 230MM X20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 194 | DIAMOND DUST MICRO NEEDLE HOLDER RD HDL 210MM X20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 195 | JAMESON SUPERCUT SCISSORS CVD.150MM X20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 196 | MICRO SCISSORS DELICATE 45°ANG.165MM X20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 197 | DIETHRICH MICRO BULLDOGCLAMP STR.16/52MM X20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 198 | LEAD SEAL W/ADHESIVE LAYER WHITE |
| 199 | SEALBLUETO SECURE THE CONT.LOCK |
| 200 | HOLDING ARM MECH.3 JOINTS RT ADAPTER |
| 201 | Universal Scope Holder, holder, diam. 3 mm - 7,50 mm, non-sterile, reusableX20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 202 | Table Clamp, adaptor, with ball and socket joint, non-sterile, reusableX20Cr13, corrosion - resistant, abrasion-proof & well legible. Laser engraving preferred, as well as individual, Machine -readable encoding to allow individual instrument tracking |
| 203 | Absorbable Cranial Fixation Clamp 11mm, sterile packaging, made from polyactide (Poly L-lactide-co-D, L-lactide) 70:30, MRI compatible |
| 204 | Absorbable Cranial Fixation Clamp 16mm, sterile packaging, made from polyactide (Poly L-lactide-co-D, L-lactide) 70:30, MRI compatible |
| 205 | METZENBAUM Advance Technology BIPOLAR Dissecting Scissors, complete instrument, bipolar, curved to left, working length: 310 mm (12 1/4\\"), diam. 5 mm, blunt/blunt, rotatable, insulated, double action, detachable, non-sterile, reusable,USFDA & CE Approved |
| 206 | MARYLAND Advance Technology BIPOLAR Grasping Forceps, complete instrument, curved, 310 mm, diam. 5 mm, double action, reusable, USFDA & CE Approved |
| 207 | MARYLAND Advance Technology BIPOLAR Grasping Forceps, complete instrument, curved, 310 mm, diam. 5 mm, fenestrated, double action, reusable, USFDA & CE Approved |
| 208 | BIPOLAR CABLE 28.6MM compatible with quoted bipolar lap instruments, USFDA & CE Approved |
| 209 | Dura Substitute onlay and suturable with size 1\\"x1\\" with Bovine Pericardium based. Two layers should not be chemically crosslinked. |
| 210 | Dura Substitute onlay and suturable with size 2\\"x2\\" with Bovine Pericardium based. Two layers should not be chemically crosslinked. |
| 211 | Dura Substitute onlay and suturable with size 1\\"x3\\" with Bovine Pericardium based. Two layers should not be chemically crosslinked. |
| 212 | Dura Substitute onlay and suturable with size 3\\"x3\\" with Bovine Pericardium based. Two layers should not be chemically crosslinked. |
| 213 | Dura Substitute onlay and suturable with size 4\\"x5\\" with Bovine Pericardium based. Two layers should not be chemically crosslinked. |
| 214 | YASARGIL TI PERM STD-CLIPSLT-CVD 8.3MM FT752T The aneurysm clip should be made of Titanium alloy Ti6Al4V according to ISO 5832-3 . The clip should ne MRI safe up to 3 Tesla and Aneurysm clip can produce moderate MRI artifacts. Depending on the MR pulse. frequency, the size of the artifacts can vary considerably. The clip should have box lock joint to avoid Scissoring affect. The blade profile should have pyramid like impression. It should be atraumatic. The clip should be supplied in sterile pack. The clip should be colour coded. It should be non-magnetic. All clip applicator should be autoclavable at 134deg. Instruments should meet the International Certification as per DIN EN ISO 13845:2001. |
| 215 | YASARGIL TI PERM STD-CLIPSLT-CVD10.2MM FT762T The aneurysm clip should be made of Titanium alloy Ti6Al4V according to ISO 5832-3 . The clip should ne MRI safe up to 3 Tesla and Aneurysm clip can produce moderate MRI artifacts. Depending on the MR pulse. frequency, the size of the artifacts can vary considerably. The clip should have box lock joint to avoid Scissoring affect. The blade profile should have pyramid like impression. It should be atraumatic. The clip should be supplied in sterile pack. The clip should be colour coded. It should be non-magnetic. All clip applicator should be autoclavable at 134deg. Instruments should meet the International Certification as per DIN EN ISO 13845:2001. |
| 216 | Titanium clip applier forceps, multi fire, working length: 370mm(14 1/2\\") diam. 10mm, Size ML, resuable, USFDA and European CE approved. |
| 217 | Multi-fire clips cartridges, titanium, medium large, last clip colour coded, package of 12 cartridges including 8 clips each,compatible with 10mm multi fire clip applier. |
| 218 | Titanium clip applier shaft, inner tube and push rod, compatible with multi fire, working length: 310mm(14 1/2\\") diam. 5mm, Size SM, resuable, USFDA and European CE approved. |
| 219 | Titanium clip applier handle compatible with multi fire, working length: 310mm, diam. 5mm, Size SM, resuable, USFDA and European CE approved. |
| 220 | Titanium clip applier rotation knob, safety ring and shield, compatible with multi fire, working length: 310mm, diam. 5mm, Size SM, resuable, USFDA and European CE approved. |
| 221 | Multi-fire clips cartridges, titanium, small medium, last clip colour coded, package of 12 cartridges including 12 clips each,compatible with 5mm multi fire clip applier. |
| 222 | Non greasy, odourless, water soluble mixure of the repetitious amino acid sequence glycine-X-Y, (where X and Y are frequently proline or hydroxyproline) & clusters of extremely small and highly reactive silver particles 0.002 Percent. 0.18oz 1 LITER |
| 223 | Non greasy, odourless, water soluble mixure of the repetitious amino acid sequence glycine-X-Y, (where X and Y are frequently proline or hydroxyproline) & clusters of extremely small and highly reactive silver particles 0.002 Percent. 1.8oz 5 LITER |
| 224 | Biological Netted material of the repetitious amino acid sequence glycine-X-Y, (where X and Y are frequently proline or hydroxyproline) with C3H8O 20x40cm |
| 225 | Biological grafting material of the repetitious amino acid sequence glycine-X-Y, (where X and Y are frequently proline or hydroxyproline) with C3H8O 20x40cm |
| 226 | Gel of col1a1 gene with aminoglycoside class antibiotic 0.1 Percent . col1a1 gene derived from specifically controlled and certified organic source and is highly purified to avoid any antiginicity. 10g bottle |
| 227 | Gel of col1a1 gene with aminoglycoside class antibiotic 0.1 Percent . col1a1 gene derived from specifically controlled and certified organic source and is highly purified to avoid any antiginicity. 20g bottle |
| 228 | Pouch of 300ML with A filter fine enough to prevent the passage of germ (0.5–5 μm in diameter), which permits removal of bacteria from solutions with Radio Frequency Identification , containing thickening agent Synthene PR700 ST109 401 sterile, IEC 6060101-1-1;6;811 CE certified |
| 229 | Single coated non woven 10mils medical attaching sheet mils with 800gm/sqm.IEC 6060101-1-1;6;811 CE certified, 144 Sq cm Medical class D device , 15.74803-23.6220 mil CE approved ultrasonic UV,large size, sterile approved via CE/MDR-V9099-04-02 bio compatible report. No endocrine-disrupting substances, No CMR, No phthalates, sterile 4 outlet sense trac 9003-0700 polypropylene homopolymer mixed with silicone containing silicon dioxide and siloxane with 90mm thickness adhesive sense trac sterileIEC 6060101-1-1;6;811 CE certified 12x12x3cm |
| 230 | Single coated non woven 10mils medical attaching sheet mils with 800gm/sqm.IEC 6060101-1-1;6;811 CE certified, 324 Sq cm Medical class D device, 15.74803-23.6220 mil CE approved ultrasonic UV,large size, sterile approved via CE/MDR-V9099-04-02 bio compatible report. No endocrine-disrupting substances, No CMR, No phthalates, sterile 4 outlet sense trac 9003-0700 polypropylene homopolymer mixed with silicone containing silicon dioxide and siloxane with 90mm thickness adhesive sense trac sterileIEC 6060101-1-1;6;811 CE certified 18x18x3cm |
| 231 | Pouch of 600ML with A filter fine enough to prevent the passage of germ (0.5–5 μm in diameter), which permits removal of bacteria from solutions with Radio Frequency Identification , containing thickening agent Synthene PR700 ST109 401 sterile, IEC 6060101-1-1;6;811 CE certified 600 ML |
| 232 | Single coated non woven 10mils medical attaching sheet mils with 800gm/sqm.IEC 6060101-1-1;6;811 CE certified, 576 Sq cm Medical class D device, 15.74803-23.6220 mil CE approved ultrasonic UV,large size, sterile approved via CE/MDR-V9099-04-02 bio compatible report. No endocrine-disrupting substances, No CMR, No phthalates, sterile 4 outlet sense trac 9003-0700 polypropylene homopolymer mixed with silicone containing silicon dioxide and siloxane with 90mm thickness adhesive sense trac sterileIEC 6060101-1-1;6;811 CE certified 24x24x3cm |
| 233 | Single coated non woven 10mils medical attaching sheet mils with 800gm/sqm.IEC 6060101-1-1;6;811 CE certified, 900 Sq cm Medical class D device 15.74803-23.6220 mil CE approved ultrasonic UV,large size, sterile approved via CE/MDR-V9099-04-02 bio compatible report. No endocrine-disrupting substances, No CMR, No phthalates, sterile 4 outlet sense trac 9003-0700 polypropylene homopolymer mixed with silicone containing silicon dioxide and siloxane with 90mm thickness adhesive sense trac sterileIEC 6060101-1-1;6;811 CE certified 30x30x3cm |
| 234 | NPWT colour Grey 17.2X17.5CM; 5 Inch TFT display; blue tooth and wifi enabled app driven Patient report generation; < 1 kg weight, 003061-022 valve with 1040-22-01 fds approved pumpIEC 6060101-1-1;6;811 CE certified. Certified parts IEC 60601-1-1:2010.IEC 60601-1-6:2010; IEC 60601-1-8:2006 safety certified |
| 235 | Mixture of an anionic water-soluble derivative of cellulo se, a linear polysaccharide of anhydro-glucose Carboxymethyl cellulose, dihydrogen oxide and Propylene glycol. Detergent micelle breaks the non-viable tissue & dead tissue.25GM 100gm |
| 236 | Reconstruct oxidized carbohydrate, or polysaccharide, consisting of 3,000 or more glucose units, a surgical instrument that stops bleeding by clamping the blood vessel.the acidic carboxyl group cpmbines with Fe3+ in hemoglobin to form gel substance 10x10cm |
| 237 | A transdermal patch is a medicated adhesive patch that is placed on the skin to deliver a specific dose of medication through the skin and into the bloodstream, An advantage of a trasdermal drug delivery route over other ty pes of medication delivery(such as oral, topical, intravenous, or intramuscular) is that the patch provides a controlled release of the medication into the patient, usually through either a porous membrane covering a reservoir of medication or through body heat melting thin layers of medication embedded in the adhesive. 25 GM 25 GM |
| 238 | A transdermal patch is a medicated adhesive patch that is placed on the skin to deliver a specific dose of medication through the skin and into the bloodstream, An advantage of a trasdermal drug delivery route over other types of medication delivery(such as oral, topical, intravenous, or intramuscular) is that the patch provides a controlled release of the medication into the patient, usually through either a porous membrane covering a reservoir of medication or through body heat melting thin layers of medication embedded in the adhesive. 50 GM |
| 239 | A transdermal patch is a medicated adhesive patch that is placed on the skin to deliver a specific dose of medication through the skin and into the bloodstream, An advantage of a trasdermal drug delivery route over other types of medication delivery(such as oral, topical, intravenous, or intramuscular) is that the patch provides a controlled release of the medication into the patient, usually through either a porous membrane covering a reservoir of medication or through body heat melting thin layers of medication embedded in the adhesive. 100 GM 100 GM |
| 240 | Deacetylated chitin with biocompatible polymer having inherent cationic property with calcium Ca++(Biochemical), Analgesic, Antimicrobial, hydrogen bonding with tissue protien & mucins.sponge 5.5x5.5x0.5 cm |
| 241 | Deacetylated chitin with biocompatible polymer having inherent cationic property with calcium Ca++(Biochemical), Analgesic, Antimicrobial, hydrogen bonding with tissue protien & mucins.sponge10.5x10.5x0.5 cm |
| 242 | Deacetylated chitin with biocompatible polymer having inherent cationic property with calcium Ca++(Biochemical), Analgesic, Antimicrobial, hydrogen bonding with tissue protien & mucins.sponge 1x1x1 cm |
| 243 | Deacetylated chitin with biocompatible polymer having inherent cationic property with calcium Ca++(Biochemical), Analgesic, Antimicrobial, hydrogen bonding with tissue protien & mucins.sponge1x3x1 cm |
| 244 | Deacetylated chitin with biocompatible polymer having inherent cationic property with calcium Ca++(Biochemical), Analgesic, Antimicrobial, hydrogen bonding with tissue protien & mucins.sponge 8.5x8.5x0.5 cm |
| 245 | Deacetylated chitin with biocompatible polymer having inherent cationic property with calcium Ca++(Biochemical), Analgesic, Antimicrobial, hydrogen bonding with tissue protien & mucins.sponge 5.5x5.5x1 cm |
| 246 | Deacetylated chitin with biocompatible polymer having inherent cationic property with calcium Ca++(Biochemical), Analgesic, Antimicrobial, hydrogen bonding with tissue protien & mucins.sponge 8.5x8.5x1 cm |
| 247 | Deacetylated chitin with biocompatible polymer having inherent cationic property with calcium Ca++(Biochemical), Analgesic, Antimicrobial, hydrogen bonding with tissue protien & mucins.Gauze 5.5x20 cm |
| 248 | Deacetylated chitin with biocompatible polymer having inherent cationic property with calcium Ca++(Biochemical), Analgesic, Antimicrobial, hydrogen bonding with tissue protien & mucins.Gauze 5.5x25 cm |
| 249 | Deacetylated chitin with biocompatible polymer having inherent cationic property with calcium Ca++(Biochemical), Analgesic, Antimicrobial, hydrogen bonding with tissue protien & mucins.Gauze 5.5x50 cm |
| 250 | Deacetylated chitin with biocompatible polymer having inherent cationic property with calcium Ca++(Biochemical), Analgesic, Antimicrobial, hydrogen bonding with tissue protien & mucins.Gauze 5.5x100 cm |
| 251 | Deacetylated chitin with biocompatible polymer having inherent cationic property with calcium Ca++(Biochemical), Analgesic, Antimicrobial, hydrogen bonding with tissue protien & mucins.Gauze 5.5x200 cm |
| 252 | Deacetylated chitin with biocompatible polymer having inherent cationic property with calcium Ca++(Biochemical), Analgesic, Antimicrobial, hydrogen bonding with tissue protien & mucins.Powder 5 ML |
| 253 | Deacetylated chitin with biocompatible polymer having inherent cationic property with calcium Ca++(Biochemical), Analgesic, Antimicrobial, hydrogen bonding with tissue protien & mucins.Powde Vr 10 ML |
| 254 | Deacetylated chitin with biocompatible polymer having inherent cationic property with calcium Ca++(Biochemical), Analgesic, Antimicrobial, hydrogen bonding with tissue protien & mucins.Powder 15 ML |
| 255 | Deacetylated chitin with biocompatible polymer having inherent cationic property with calcium Ca++(Biochemical), Analgesic, Antimicrobial, hydrogen bonding with tissue protien & mucins.Powder 20 ML |
| 256 | Deacetylated chitin with biocompatible polymer having inherent cationic property with calcium Ca++(Biochemical), Analgesic, Antimicrobial, hydrogen bonding with tissue protien & mucins.Powder 50 ML |
| 257 | Klercide 70|30 IPA Blended with WFI. 70 Percent v/v Isopropyl alcohol blended with 30 Percent v/v water for injection with sterisheild deliverysystem in 1L US FDA APPROVED KLERCIDE 70/30 IPA 1l |
| 258 | Klercide 70|30 IPA Blended with WFI. 70 Percent v/v Isopropyl alcohol blended with 30 Percent v/v water for injection with sterisheild deliverysystem in 500ML US FDA APPROVED KLERCIDE 70/30 IPA 500 ML |
| 259 | Klercide 70|30 IPA Blended with WFI. 70 Percent v/v Isopropyl alcoholblended with 30 Percent v/v water for injection in 5L capped container US FDA APPROVED KLERCIDE 70/30 IPA 5L |
| 260 | Klercide Sporicidal Low Residue Peroxide Blended with WFI. A blend of high grade 6 Percent hydrogen peroxide and Water for Injection (WFI) in sterisheild delivery system 1L US FDA APPROVED KLERCIDE SPOR LOW RES PEROX 1L |
| 261 | Klercide Sporicidal Low Residue Peroxide Blended with WFI. A blend of high grade 6 Percent hydrogen peroxide and Water for Injection (WFI) in capped container 5L US FDA APPROVED KLERCIDE SPOR LOW RES PEROX 5L |
| 262 | Neutral detergent non ionic, with pH of 5.5-7.5 it is mix of deionised water and a fatty alcohol ethyloxylate that is then 0.2 micron filtered and double bagged in a Grade C cleanroom, gamma sterile US FDA APPROVED KLERCIDE NEUTRAL |
| 263 | Klercide Sporicidal Active Chlorine Unit Dose Concentrate 170g US FDA APPROVED KLERCIDE SPOR ACTIVE CHLORINE UDC 12-170GM |
| 264 | Klercide 100 Percent Polyester Pouch Wipe impregnated with 70 Percent IPA Blended with WFI 200X200 mm US FDA APPROVED KLERWIPE POUCH WIPE 200x200mm |
| 265 | Klercide 100 Percent Polyester Pouch Wipe impregnated with 70 Percent IPA Blended with WFI 300X300 mm US FDA APPROVED KLERWIPE POUCH WIPE 300x300mm |
| 266 | Sterile Low particulate wipes impregnated with silicone 20X15WIPES US FDA APPROVED KLERWIPE SILICON WIPES |
| 267 | Klerwipe Sporicidal Low Residue Wipes 20X15 Wipes US FDA APPROVED KLERWIPE SPOR SILICON WIPES |
| 268 | Stainless Steel Pressurised Spray System for use with Klercide biocides US FDA APPROVED KLERCIDE SPRAY |
| 269 | CSD SET sheathe blanket mention below specs,EU CE marked,EN13795,TUV approved with certified test for, Resistance to Microbial Penetration test (Dry & Wet),Resistance to liquid penetration test, Cleanliness test. (Microbial & Particulate matter),Bursting strength ( Dry & Wet),Tensile strength test ( Dry & Wet),Linting test.Back TC 150 X 190,4 T -30 X 40,ITC- Mayo Stand 80 x 145,Adhesive Strip-9x50, BD, fluid-absorbent nonwoven material 90 x 90, for the supine position, 230/200 x 312, with abdominal fenestration, 27 x 33 with integrated incise film, with integrated pouch incl. drainage port, with armrest |
| 270 | RBD EU CE marked, EN13795,TUV approved with certified test for, Resistance to Microbial Penetration test (Dry & Wet) Resistance to liquid penetration test, Cleanliness test. (Microbial & Particulate matter), Bursting strength (Dry & Wet), Tensile strength test (Dry & Wet),Linting test, sheathe blanket with fluid absorbent nonwoven material Size 90x100 cm |
| 271 | CGD EU CE marked,EN13795,TUV approved with certified test for, Resistance to Microbial Penetration test (Dry & Wet)Resistance to liquid penetration test, Cleanliness test. (Microbial & Particulate matter),Bursting strength ( Dry & Wet),Tensile strength test ( Dry & Wet),Linting test, sheathe blanket with perineal fenestration, centred Size 175x 90 cm |
| 272 | UBD EU CE marked,EN13795,TUV approved with certified test for, Resistance to Microbial Penetration test (Dry & Wet)Resistance to liquid penetration test, Cleanliness test. (Microbial & Particulate matter),Bursting strength ( Dry & Wet),Tensile strength test ( Dry & Wet),Linting test Buttocks sheathe blanket Size 75x 120 cm,Non-woven sheathe blankets With high-absorbency, fluid-impermeable nonwoven material with polyethylene backing, featuring ultrasonic-sealed edges for leak prevention surgical sheathe blanket standards for single-use . |
| 273 | UDS sheathe blanket Set (Multiple Procedure Kit) mention below specs, CE,ISO,TUV,EN13795 approved with certified test for, Resistance to Microbial Penetration test (Dry & Wet)Resistance to liquid penetration test, Cleanliness test. (Microbial & Particulate matter),Bursting strength ( Dry & Wet),Tensile strength test ( Dry & Wet),Linting test,Back Table -150 X 190, moist moist toweletteette -30 X 20,Instrument Cover- Mayo Stand 80 x 145,Adhesive Strip-9 X 25,Adhesive sheathe blankets Side-75 x 90,Adhesive sheathe blankets- Bottom-175 x 170,Adhesive sheathe blankets- Top-140 x 240 |
| 274 | Latex free padding made up of 100 Percent polyurethane, highly breathable and permeable to moisture and have slip resistant assurance to prevent bandage sliding, can be washed up to 50 times and should tear resistant and stretchable. Size 10 CMx0.3CMX2.5 Mtr CE & ISO Certified |
| 275 | 100 Percent cotton wrap having lengthwise elasticity about 90 Percent, high air permeability, textured fabric, cream coloured, can be washed up to 50 times at 90 degrees Celsius 4 cmx5 mtr CE & ISO Certified |
| 276 | 100 Percent cotton wrap having lengthwise elasticity about 90 Percent, high air permeability, textured fabric, cream coloured, can be washed up to 50 times at 90-degree Celsius 6 cmx5 mtr CE & ISO Certified |
| 277 | 100 Percent cotton wrap having lengthwise elasticity about 90 Percent, high air permeability, textured fabric, cream coloured, can be washed up to 50 times at 90-degree Celsius 10cmx5 mtr CE & ISO Certified |
| 278 | 100 Percent cotton wrap having lengthwise elasticity about 90 Percent, high air permeability, textured fabric, cream coloured, can be washed up to 50 times at 90-degree Celsius 8 cmx5 mtr CE & ISO Certified |
| 279 | 100 Percent cotton wrap having lengthwise elasticity about 90 Percent, high air permeability, textured fabric, cream coloured, can be washed up to 50 times at 90 degrees Celsius 12 cmx5 mtr CE & ISO Certified |
| 280 | Comfortable, open-weave gauze bandage is ideal for wrapping fingers and toes in lymphological compression bandaging. Bandages are elastic in length by approx. 100 Percent and permeable to air and skin friendly. Size 4 cm |
| 281 | Comfortable, open-weave gauze bandage is ideal for wrapping fingers and toes in lymphological compression bandaging. Bandages are elastic in length by approx. 100 Percent and permeable to air and skin friendly. Size 6 cm |
| 282 | Double-sewn liner with color coded velcro branded faster Wrap with padded wrist & elbow upto arm |
| 283 | Double-sewn liner with color coded velcro branded faster Wrap with padded to overlap the right Gaunlet with pocket design |
| 284 | Double-sewn liner with color coded velcro branded faster Wrap with padded to overlap the left Gaunlet with pocket design |
| 285 | Front fastetnig short strap with liner easy to don 2 step design withh color coded velcro for left foot |
| 286 | Front fastetnig short strap with liner easy to don 2 step design withh color coded velcro for right foot |
| 287 | Front fastetnig short stretch material strap with liner easy for easy donning 2 step design withh color coded velcro for thigh L |
| 288 | Front fastetnig short stretch material strap with liner easy for easy donning 2 step design withh color coded velcro for thigh XL |
| 289 | CE & ISO certified Oralcare Kit with Ergonomic Oralcare Suction Handle, Oralcare Yankauer with PEEP seal technology, Oralcare Suction Toothbrush with Silicon Bristles with ON-OFF Button |
| 290 | CE & ISO Certified • Directional tip allows Left or Right lung sampling.• Soft and radiopaque tip. • PEEP Seal to maintain the PEEP.• Two way valve.• Marked Catheter for measured depth suctioning.Size 13 FR OC & 8 FR IC |
| 291 | indwelling device advanced until the terminal lumen resides within the inferior vena cava Cathe adult 3 lumen 7Fr & 16 cm length with raulerson syringe to reduce blood loss, Non kinking guide wire made up of 45 Percent titanium & 55 Percent nickel, with CE,ISO & HTCert certified |
| 292 | indwelling device advanced until the terminal lumen resides within the inferior vena cava Cathe adult 3 lumen 7Fr & 15 cm length with raulerson syringe to reduce blood loss, Non kinking guide wire made up of 45 Percent titanium & 55 Percent nickel, with CE,ISO & HTCert certified |
| 293 | indwelling device advanced until the terminal lumen resides within the inferior vena cava Cathe adult 3 lumen 7Fr & 14 cm length with raulerson syringe to reduce blood loss, Non kinking guide wire made up of 45 Percent titanium & 55 Percent nickel, with CE,ISO & HTCert certified |
| 294 | indwelling device advanced until the terminal lumen resides within the inferior vena cava Cathe 3Fr 1 lumen with raulerson syringe to reduce blood loss, Non kinking guide wire made up of 45 Percent titanium & 55 Percent nickel, with CE,ISO & HTCert certified |
| 295 | indwelling device advanced until the terminal lumen resides within the inferior vena cava Cathe 4Fr 1 lumen with raulerson syringe to reduce blood loss, Non kinking guide wire made up of 45 Percent titanium & 55 Percent nickel, with CE,ISO & HTCert certified |
| 296 | indwelling device advanced until the terminal lumen resides within the inferior vena cava Cathe 4Fr 2 lumen with raulerson syringe to reduce blood loss, Non kinking guide wire made up of 45 Percent titanium & 55 Percent nickel, with CE,ISO & HTCert certified |
| 297 | indwelling device advanced until the terminal lumen resides within the inferior vena cava Cathe 4.5 Fr Single lumen with raulerson syringe to reduce blood loss, Non kinking guide wire made up of 45 Percent titanium & 55 Percent nickel, with CE,ISO & HTCert certified |
| 298 | indwelling device advanced until the terminal lumen resides within the inferior vena cava Cathe 5Fr Single lumen with raulerson syringe to reduce blood loss, Non kinking guide wire made up of 45 Percent titanium & 55 Percent nickel, with CE,ISO & HTCert certified |
| 299 | indwelling device advanced until the terminal lumen resides within the inferior vena cava Cathe 5Fr Double lumen with raulerson syringe to reduce blood loss, Non kinking guide wire made up of 45 Percent titanium & 55 Percent nickel, with CE,ISO & HTCert certified |
| 300 | indwelling device advanced until the terminal lumen resides within the inferior vena cava Cathe 5Fr Triple lumen with raulerson syringe to reduce blood loss, Non kinking guide wire made up of 45 Percent titanium & 55 Percent nickel, with CE,ISO & HTCert certified |
| 301 | indwelling device advanced until the terminal lumen resides within the inferior vena cava Cathe 5.5Fr 1 lumen with raulerson syringe to reduce blood loss, Non kinking guide wire made up of 45 Percent titanium & 55 Percent nickel, with CE,ISO & HTCert certified |
| 302 | indwelling device advanced until the terminal lumen resides within the inferior vena cava Cathe 5.5Fr 2 lumen with raulerson syringe to reduce blood loss, Non kinking guide wire made up of 45 Percent titanium & 55 Percent nickel, with CE,ISO & HTCert certified |
| 303 | indwelling device advanced until the terminal lumen resides within the inferior vena cava Cathe 5.5Fr 3L with raulerson syringe to reduce blood loss, Non kinking guide wire made up of 45 Percent titanium & 55 Percent nickel, with CE,ISO & HTCert certified |
| 304 | Bioactive dressing composed of a polyester lattice embedded in a polymer matrix, combined with Vaseline and hydrocolloid. Having size of 10x10 CM ,provide a moist environment conducive to healing while preventing adherence to the bed. The Vaseline component ensures hydration of dry areas and edges, promoting optimal care and patient comfort. |
| 305 | additional reinforcement around in preventing the disturbance that is accidental movement child-friendly design having monitoring window cutout for additional tension relief film-nonwoven laminate counter fixation element with V-shaped cutout lengthwise elasticity additional sterile cushioning pad, MVTR at the puncture site: 966 g / 24 h / m² SIZE-4.3X5 CM, CE & ISO Certified. |
| 306 | additional reinforcement around in preventing the disturbance that is accidental movement rectangular shape and rounded corners with monitoring window, having MVTR in the area of fixation: 964 g / 24 h / m² ,die-cut opening, lengthwise elasticity additional sterile cushioning pad with fixation size-5.5x6.5 CM,CE & ISO Certified |
| 307 | additional reinforcement around in preventing the disturbance that is accidental movement Rectangular shape with rounded corners pure nonwoven additional reinforcement around in preventing the disturbance that is accidental movement 6x7.5 , having die-cut opening lengthwise elasticity up to 0.6 N / 12 mm and pad 20 x 20 mm, CE & ISO Certified |
| 308 | additional reinforcement around in preventing the disturbance that is accidental movement TCVV ergonomic shape film with porous adhesive coating, monitoring window large film-nonwoven laminate counter fixation element with V-shaped cutout lengthwise elasticity additional sterile cushioning pad size 9x11 ,CE & ISO Certified |
| 309 | wide retention polyester dressing having polyacrylate strip patterned adhesive coating with MVTR more than 5000 g/m2/24hr and air permeability more than 4000 g/m2/24hr SIZE 10cmx2m,CE & ISO Certified |
| 310 | EU CE marked, EN13795,TUV approved with certified test for, Resistance to Microbial Penetration test (Dry & Wet) Resistance to liquid penetration test, Cleanliness test. (Microbial & Particulate matter), Bursting strength (Dry & Wet), Tensile strength test (Dry & Wet),Linting test, Baby sheathe blanket with fluid absorbent nonwoven material Size 90x100 cm, Non-woven sheathe blankets With high-absorbency, fluid-impermeable nonwoven material with polyethylene backing, featuring ultrasonic-sealed edges for leak prevention surgical sheathe blanket standards for single-use ,Class 1 EC Medical Device with Accuracy and waterproof adhesive thermochromic temperature indicator with three colour code |
| 311 | indwelling device advanced until the terminal lumen resides within the inferior vena cava Cathe adult 3 lumen 7Fr & 16 cm length with raulerson syringe to reduce blood loss, Non kinking guide wire made up of 45 Percent titanium & 55 Percent nickel, with CE,ISO & HTCert certified,Class 1 EC Medical Device with Accuracy and waterproof adhesive thermochromic temperature indicator with three colour code,CVC Dressing with ergonomic shape film with porous adhesive coating, monitoring window large film-nonwoven laminate counter fixation element with V-shaped cutout lengthwise elasticity additional sterile cushioning pad size 9x11 CM,CE & ISO Certified |
| 312 | CE & ISO Certified,USFDA approved, TRACH Care Technology Close Suction 16 FR Endotracheal,Class 1 EC Medical Device with Accuracy and waterproof adhesive thermochromic temperature indicator with three colour code, CE & ISO certified Oralcare Kit with Ergonomic Oralcare Suction Handle, Oralcare Yankauer with PEEP seal technology, Oralcare Suction Toothbrush with Silicon Bristles with ON-OFF Button |
| 313 | KCNS For Surgery Used For Percutaneous Entry Into Vessel Using The Seldinger Technique Or Endoscopic Access * For Easier Visualization * Non - Kink Nitional Shaft 0.025 , 0.032 , 0.035 & 150 CM , 450 CM US FDA APPROVED |
| 314 | twin floor bottom inner lid 19-12001 Large Microsurgical Double floor Instrument apparatus for destroying viable microorganisms patented design Slot Lock System™ allows for easy positioning of the special Easy-Hold™ silicone products are molded from medical grade silicone. SizeCOMPOUND 14x10x4 /12x8x1.5 |
| 315 | small floor size bottom with lid 1912002/1912003 Large Microsurgical Double floor Instrument apparatus for destroying viable microorganisms patented design Slot Lock System™ allows for easy positioning of the special Easy-Hold™ silicone products are molded from medical grade silicone. SizeCOMPOUND 14x10x4 /12x8x1.5 |
| 316 | medium twin floor bottom inner and lid 1912005 Large Microsurgical Double floor Instrument apparatus for destroying viable microorganisms patented design Slot Lock System™ allows for easy positioning of the special Easy-Hold™ silicone products are molded from medical grade silicone. SizeCOMPOUND -19x8x3.25 / 16x7.75x1.5 |
| 317 | large double twin flooring case bottom inner wih lid 1912008/1912009mb Large Microsurgical Double Instrument apparatus for destroying viable microorganisms patented design Slot Lock System™ allows for easy positioning of the special Easy-Hold™ silicone products are molded from medical grade silicone. SizeCOMPOUND - 22.5x8x3.25 |
| 318 | multiple with lid 1912049 Large surgical floor Instrument apparatus for destroying viable microorganisms patented design Slot Lock System™ allows for easy positioning of the special Easy-Hold™ silicone products are molded from medical grade silicone. SizeCOMPOUND - 16x7.75x1.5 |
| 319 | cord channel set with lid 1912053A Large surgical floor Instrument apparatus for destroying viable microorganisms patented design Slot Lock System™ allows for easy positioning of the special Easy-Hold™ silicone products are molded from medical grade silicone. SizeCOMPOUND - 17x6.5x2/19x8x2 |
| 320 | bariatrics XL bottom with bridge floor with lid 1912061 Large surgical apparatus for destroying viable microorganisms Instrument patented design Slot Lock System™ allows for easy positioning of the special Easy-Hold™ silicone products are molded from medical grade silicone. SizeCOMPOUND - 25.50x12x4.50 |
| 321 | set with lid 1912005A-b / 1912008 surgical Compartment Instrument apparatus for destroying viable microorganisms patented design Slot Lock System™ allows for easy positioning of the special Easy-Hold™ silicone products are molded from medical grade silicone. SizeCOMPOUND - 19x8x3.25 |
| 322 | double floor with lid 1912062A Large surgicalapparatus for destroying viable microorganisms Instrument patented design Slot Lock System™ allows for easy positioning of the special Easy-Hold™ silicone products are molded from medical grade silicone. SizeCOMPOUND - 22.5x8x3.25 |
| 323 | multiple three floor with lid 2111040xl Large surgicalapparatus for destroying viable microorganisms Instrument patented design Slot Lock System™ allows for easy positioning of the special Easy-Hold™ silicone products are molded from medical grade silicone. SizeCOMPOUND - 22x12x11 |
| 324 | Catheter for atraumatic fixation of hernia prosthesesA total evolution in the methods of atraumatic fixation of hernia nets Designed from years of experience inherited from the application in laparoscopic and laparotomic hernia surgery. The GLUT® device allows the application in the form of calibrated drops (0.0125 ml / drop - 12.5 mg) in surgical procedures performed in laparoscopy. Mainly designed for the application of in the atraumatic fixation of prostheses in plastic surgery of hernias and laparoceles. Each time the trigger is pressed / released, a calibrated drop is delivered from the distal end of the catheter. Glut® + tis 2 equal to 1 high performance anchor Each single device can be loaded with a quantity of relative to the format indicated on the package and on the handle, therefore sufficient, in relation to the different formats, for at least 25, 40 or 50 drops. size:2 |
| 325 | Laparoscopic Catheter for manual glue release This disposable device allows to apply Glubran drop by drop during laparoscopic surgery. The catheter has to be used with 5 mm diameter trocar. The capillary section lumen catheter allows to control the application and to lay Glubran in a thin layer in laparoscopic surgery, whenever it is necessary to get haemostasis, adhesion, sealing and strengthen s. |
| 326 | Catheter for atraumatic fixation of hernia prostheses A total evolution in the methods of atraumatic fixation of hernia netsDesigned from years of experience inherited from the application of Glubran in laparoscopic and laparotomic hernia surgery.The GLUT device allows the application of Glubran in the form of calibrated drops (0.0125 ml / drop - 12.5 mg) in surgical procedures performed in laparoscopy. Mainly designed for the application of Glubran® 2 in the atraumatic fixation of prostheses in plastic surgery of hernias and laparoceles.Each time the trigger is pressed / released, a calibrated drop is delivered from the distal end of the catheter.Glutack® + Glubran® 2 equal to 1 high performance adhesive anchorEach single device can be loaded with a quantity of Glubran® 2 relative to the format indicated on the package and on the handle, therefore sufficient, in relation to the different formats, for at least 25, 40 or 50 drops. |
| 327 | Short small nebuliz The system allows the application of Glubran 2 Surgical Glue in nebulized form in laparotomic and thoracoscopic surgical procedures. |
| 328 | Short nebuliz The system allows the application of Glubran 2 Surgical Glue in nebulized form in laparotomic and thoracoscopic surgical procedures. |
| 329 | Applicator tip disposable device that allows you to apply GLUBRAN glues topically, both during surgery and during the treatment of traumatic and atraumatic skin wounds. It connects directly to the vial of glue and is used as a brush for a precise and localized application of GLUBRAN |
| 330 | Disposable syringe prod_syringe-disposable_800Disposable sterile syringe, 1 ml, graduated, in polypropylene, with luer connection. |
| 331 | LIGHT UP YOUR SURGERY The device illuminates the surgical field in an optimal, comfortable and practical way, regardless of the ambient lighting, allowing you to work easily in poorly lit areas. improves the surgeon's vision in all conditions, even in the deepest incisions and in procedures with difficult access, reducing complications, facilitating and reducing the time of the operating procedure. device is a luminous ring with LED technology that can be adapted to any surgical instrument, whether it is the handle of an electric scalpel or any other instrument needed in a surgical procedure, without interfering in its operation.Autonomy Up to five hours of intense lightAdaptability Compatible with any instrument with a diameter of 5 to 8 mm.Versatility Up to 3 RUTILIGHT devices simultaneously connected to the same power source. Convenience Low energy consumption. Excellent quality color temperature for the best color rendering of organs, vessels and tissues. |
| 332 | Smoke Filter haracteristic Carcinogens and smoke are filtered out through PRE / ACF / DNA filters. Smoke lean SJ-SF-03 80mm X 40mm X 23mm, Valve 270mm 10ea/Box |
| 333 | Single Port Lapsing Vision Just only one universal port in the world for all kind of single port laparoscopic surgery including Robot surgery characteristic Detachable single port for single incision laparoscopic surgery high transparency Universal port for a variety of instruments from a minimum of 5 mm to a maximum of 12 mm Spring valve to facilitate gas circulation Optimized for robotic surgery with high flexibility and heat resistance 10mm X 3 |
| 334 | Single Port Lapsing Vision Just only one universal port in the world for all kind of single port laparoscopic surgery including Robot surgery characteristic Detachable single port for single incision laparoscopic surgery high transparency Universal port for a variety of instruments from a minimum of 5 mm to a maximum of 12 mm Spring valve to facilitate gas circulation Optimized for robotic surgery with high flexibility and heat resistance 12mm X 1 |
| 335 | Single Port Lapsing Vision Just only one universal port in the world for all kind of single port laparoscopic surgery including Robot surgery characteristic Detachable single port for single incision laparoscopic surgery high transparency Universal port for a variety of instruments from a minimum of 5 mm to a maximum of 12 mm Spring valve to facilitate gas circulation Optimized for robotic surgery with high flexibility and heat resistance 15mm X 1 |
| 336 | lapsingle Laparoscopic Single PortJust only one universal port in the world for all kind of single port laparoscopic surgery including Robot surgery characteristicDetachable single port for single incision laparoscopic surgeryUniversal port for a variety of instruments from a minimum of 5 mm to a maximum of 12 mm Spring valve to facilitate gas circulation 12mm X 1, |
| 337 | lapsingle Laparoscopic Single PortJust only one universal port in the world for all kind of single port laparoscopic surgery including Robot surgery characteristicDetachable single port for single incision laparoscopic surgeryUniversal port for a variety of instruments from a minimum of 5 mm to a maximum of 12 mm Spring valve to facilitate gas circulation 5mm X 3 |
| 338 | lapsingle Laparoscopic Single PortJust only one universal port in the world for all kind of single port laparoscopic surgery including Robot surgery characteristicDetachable single port for single incision laparoscopic surgeryUniversal port for a variety of instruments from a minimum of 5 mm to a maximum of 12 mm Spring valve to facilitate gas circulation 12mm X 2, |
| 339 | lapsingle Laparoscopic Single PortJust only one universal port in the world for all kind of single port laparoscopic surgery including Robot surgery characteristicDetachable single port for single incision laparoscopic surgeryUniversal port for a variety of instruments from a minimum of 5 mm to a maximum of 12 mm Spring valve to facilitate gas circulation 5mm X 2 |
| 340 | lapsingle Laparoscopic Single PortJust only one universal port in the world for all kind of single port laparoscopic surgery including Robot surgery characteristicDetachable single port for single incision laparoscopic surgeryUniversal port for a variety of instruments from a minimum of 5 mm to a maximum of 12 mm Spring valve to facilitate gas circulation 5mm X 4mm |
| 341 | lapsingle Laparoscopic Single PortJust only one universal port in the world for all kind of single port laparoscopic surgery including Robot surgery characteristicDetachable single port for single incision laparoscopic surgeryUniversal port for a variety of instruments from a minimum of 5 mm to a maximum of 12 mm Spring valve to facilitate gas circulation |
| 342 | Laparoscopic Single Port Just only one universal port in the world for all kind of single port laparoscopic surgery including Robot surgery characteristic Detachable single port for single incision laparoscopic surgery high transparency Universal port for a variety of instruments from a minimum of 5 mm to a maximum of 12 mm Spring valve to facilitate gas circulation Optimized for robotic surgery with high flexibility and heat 10mm X 3 |
| 343 | Laparoscopic Single Port Just only one universal port in the world for all kind of single port laparoscopic surgery including Robot surgery characteristic Detachable single port for single incision laparoscopic surgery high transparency Universal port for a variety of instruments from a minimum of 5 mm to a maximum of 12 mm Spring valve to facilitate gas circulation Optimized for robotic surgery with high flexibility and heat 12mm X 1 |
| 344 | Laparoscopic Single Port Just only one universal port in the world for all kind of single port laparoscopic surgery including Robot surgery characteristic Detachable single port for single incision laparoscopic surgery high transparency Universal port for a variety of instruments from a minimum of 5 mm to a maximum of 12 mm Spring valve to facilitate gas circulation Optimized for robotic surgery with high flexibility and heat 15mm X 1 |
| 345 | MASK G-1 TYPE 1. Used in painless gastroscopy. 2. Various specification fiberscope apertures are convenient for examination and treatment. 3. Intubation and ventilation can be operated and shorten the operation time. 4. Size-3, should have both US FDA and CE marked |
| 346 | MASK G-1 TYPE 1. Used in painless gastroscopy. 2. Various specification fiberscope apertures are convenient for examination and treatment. 3. Intubation and ventilation can be operated and shorten the operation time. 4. Size,4 should have both US FDA and CE marked |
| 347 | ultima percutaneous placement device in the pelvis of nephrostomy complete set.US-FDA Approved strictly. |
| 348 | ultima percutaneous placement device in the pelvis of nephrostomy complete set with locking system .US-FDA Approved strictly. |
| 349 | UPCN-P WITH biocompatible with stop cock radioopaque US-FDA Approved STRICTLY :size :- 8,9,10,12,14 length 20,30 cm |
| 350 | UDPD when there is diluted urine collection system hydronephrosis used in skin incision directly US-FDA Approved:size:- 8,9,10,12,14 length 20,30 cm |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail