| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: |
| 2 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 4 | Brick work with common burnt clay F.P.S.(non-modualar) bricks of class designation 75 in foundation and plinth in Cement mortar 1 :6 ( 1 cement : 6 coarse sand) & Extra for brick work in superstructure above plinth level upto floor V level. (By manual means) |
| 5 | Extra for brick work in superstructure above plinth level upto floor V level. (By manual means) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 9 | Centring and shuttering including strutting , propping etc. and removal of form work for Foundations , footings bases of columns etc. for mass concrete |
| 10 | Centring and shuttering including strutting , propping etc. and removal of form work for Suspended floors, roofs, landing, balconies and access plate form |
| 11 | Centring and Shuttering including strutting, propping etc and removal of form work for Edges of Slabs and Break in floors and walls (Under 20 cms wide) |
| 12 | 6mm cement plaster to ceiling of mix 1:3 ( 1 cement :3 fine sand). |
| 13 | 12 mm cement plaster of mix 1:6 ( 1 cement : 6 coarse sand) |
| 14 | 15mm Cement plaster on the rough side of single or half brick wall of mix 1 : 6 ( 1 cement : 6 fine sand) |
| 15 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 16 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. Layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m. |
| 17 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 18 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete.In colour such as White, Ivory, Grey, Fume Red Brown |
| 19 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 20 | Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggreagate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. Crushed |
| 21 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 22 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre,two or more coats on new work of approved manufacturer, of required shade and colour complete as per manufacturer’s specifications |
| 23 | Finishing walls with water proofing cement paint of required shade New work (two or more coats) applied @ 3.84 kg/10 sqm |
| 24 | Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. 110 mm diameter . |
| 25 | Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. 75 mm diameter . |
| 26 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing. 15mm nominal outer dia pipes. |
| 27 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing. 20mm nominal outer dia pipes. |
| 28 | Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. Single tee without door |
| 29 | 75mmx75mmx75mm dia |
| 30 | 110mmx110mmx110mm |
| 31 | Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. Bend 87.5 degree |
| 32 | 75mm dia |
| 33 | 110mm dia |
| 34 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 35 | Providing and fixing wash basin with C.I/M.S brackets, 15mm C.P brass pillar taps, 32mm C.P brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. |
| 36 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back ,for the reception of pipes and fittings |
| 37 | Providing and fixing 15 mm nominal bore C.P. brass bib cock ofapproved quality conforming to IS : 8931 |
| 38 | Proving and laying in position flow trap including all fittings , complete job. |
| 39 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 40 | Providing and fixing uplasticized PVC connection pipe with brass unions 30 cm length 15 mm nominal bore |
| 41 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete Flexible pipe 32 mm dia |
| 42 | Providing and fixing CP grading of 100 mm dia of approved brand. |
| 43 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms. |
| 44 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 20 mm nominal bore |
| 45 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 46 | Carriage of materials by mechanical transport including loading / unloading and stacking complete. Sand lead up to 60 kms avg. |
| 47 | Carriage of materials by mechanical transport including loading / unloading and stacking complete. Stone aggregate lead up to 25 kms avg. |
| 48 | Carriage of materials by mechanical transport including loading / unloading and stacking complete. Bricks lead up to 40 kms avg. Please Enable Macros to View BoQ information |