| 1 | Toilet Renovation |
| 2 | Dismantling of Existing Reinforced Cement Concrete including all cost of conveyance of materials and Labour charges in safety manner etc ,Complete Complying with standard specification and as directed by the Departmental Officer ans as follows |
| 3 | Dismantling of Existing Brick work including all cost of conveyance of materials and Labour charges in safety manner etc ,Complete Complying with standard specification and as directed by the Departmental Officer ans as follows |
| 4 | Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D) etc complete., |
| 5 | Centering 2 |
| 6 | Providing and laying Standardised Concrete Mix M-20 Grade in accordance with IS 456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minium cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m) 5156 kg of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charge, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor/roof slabs wherever necessary without claming extra etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. |
| 7 | Basement |
| 8 | Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors. including charges for cutting, Straightening, and bending, typing, Welding, Jointing, over laping and all labour charges etc. |
| 9 | Brick work in following Cement Mortar 1:5 ( one cement and five sand) using best quality Fly Ash bricks of size 230x110x75mm for foundation and basement including curing etc.,complete complying with standard specification. |
| 10 | Brick Partition Walls using II class ground moulded chamber bricks of size 9\\"X43/8\\"X 23/4\\" in C.M 1:3 (One part of Cement and Three part of Crushed Stone Sand (M- Sand)) using hoop iron reinforcement,if found necessary standard specification including finishing, curing,etc., complete complying with standard specification - 10 sqm |
| 11 | Plastering with CM 1:5, 12mm (one cement and five M. sand) thick including cost and conveyance of all materials to site and labour charges etc. complete as per standard specifications |
| 12 | Plastering with cement mortar 1:4 (One Part of Cement and Four part of Plastering Sand (P- Sand)) 20mm thick in all floors including cost and conveyance of all materials to site and labour charges etc, complete complying with standard specifications (S.I.309) |
| 13 | Providing granolithic floor finish of 25mm thickness with plain cement concrete 1:2:4 (One Cement, Two crushed sand (M-Sand) and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers) |
| 14 | Supply,delivery of PVC pipes and specials including Cost and Conveyance of materials,Labour Charges etc complete |
| 15 | 110 mm pvc pipe |
| 16 | 40mm pvc pipe |
| 17 | 40 mm pvc bend |
| 18 | Elbow 40mm pvc |
| 19 | Tee 40 mm pvc |
| 20 | Reducer 40 x32 mm pvc |
| 21 | Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading,unloading, transportation and labour ,charges for fixing of the GI pipes and cutting, threading and fixing charges etc. |
| 22 | Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with 'P' trap or 'S' trap confirming to IS:2556 - Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers. |
| 23 | Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 liters capacity PVC / 12.5 liters capacity porcelain low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting |
| 24 | Painting two coats of approved Plastic Emulsion paint approved quality and colour over a existing suface, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. |
| 25 | Supplying and fixing in position best quality approved make white glazed earthenware wash hand basin of size 550 X 400 mm with a pair of cast iron brackets, including cost of 15mm diametre brass chromium plated piller tape,32 mm diametre C.P. Waste union, 32 mm diametre P.V.C. waste pipe with rubber plug and chain, 15mm diametre G.M.wheel valve, 15mm dia brass nipple, 15mm dia nylon connections etc., including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and paintiung the brackets with two coats of paint over a primimg coat of anticorrosive paint including testing for leackage etc., complete complying with standard specifications |
| 26 | Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coat including the cost all materials etc.,complete, in all floors. |
| 27 | Plastering with cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications |
| 28 | Supplying and fixing of 16 mm thick bison shutter including cost of suitable \\"T\\" hinges, bolt nuts, handle and cost of teak wood lipping for alround the bison shutters, including cost and conveyance and labour charges for wrought and put up etc., complete |
| 29 | Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement |
| 30 | Supply,delivery and fixing of Cuddapah Slab of 40 mm thickness over outlet Drain wall with all cutting and grinding charges including all cost conveyance of materials andlabour charges etc complete . |
| 31 | Dadooing walls with Glazed tiles of sizes 305mm X 200mm X 6mm size of approved make and quality and colour Set in cement mortar 1:2 (One part of Cement and two part of Plastering Sand (P- Sand)) over 10 mm base layer plastering and pointing with white cement neatly as directed. |
| 32 | Supply and fixing Crystal Glass LED Tube Light fitting including all cost and conveyance of materials ,Labour etc complete |
| 33 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated unsheathed SC copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A FT switch inflush with wall covered with hylum sheet of 3mm thick ith painting of suitable colour for open PVC light / fan point (for electronic regulator) (5 points per coil) |
| 34 | Add for Goods and Service Tax 18% Please Enable Macros to View BoQ information |