| 1 | Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. |
| 2 | 3 core 4.0 Sq.mm |
| 3 | 3 core 6.0 Sq.mm |
| 4 | 3 core 10.0 Sq.mm |
| 5 | 3 core 16.0 Sq.mm |
| 6 | Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. |
| 7 | 10.0 Sq.mm, 4 core |
| 8 | 16.0 Sq.mm, 4 core |
| 9 | 25.0 Sq.mm, 3.5 core |
| 10 | 35.0 Sq.mm, 3.5 core |
| 11 | Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 12 | Manually Operated CI Sluice valve of Class PN-1.0 |
| 13 | 80 mm HW |
| 14 | 100 mm HW |
| 15 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. |
| 16 | MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet) |
| 17 | P & F G.I. pipes (Internal Work) with G.I. Fittings excludingunion (IS:1239 Mark) & MS clamps including cutting andmaking good the walls and floors |
| 18 | 50mm dia nominal bore B' Class |
| 19 | 65mm dia nominal bore B' Class |
| 20 | 80mm dia nominal bore B' Class |
| 21 | Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes |
| 22 | 65 mm dia |
| 23 | 80 mm dia |
| 24 | Providing & Fixing of ISO certified company made 240/415 V porcelain kitkat fuse (/HBC type) as per PWD specification for electrical Works conforming to IS:2086,1983 on existing board/ sheet including making connections with lugs, testing etc. as required . Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR |
| 25 | 63 A , 415 V |
| 26 | 100 A , 415 V |
| 27 | 200 A , 415 V |
| 28 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 29 | up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 30 | P & F of Auxiliary Contactor for AC control standard. 24 V Coil 110, 240 V, 415 V, 50 Hz conforming to IS:13947-4-1/IEC:60947-4-1 with required NO & NC combination including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Please Enable Macros to View BoQ information |