| 1 | Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority: Executive Engineer(E) PWD M-253 Name of Work:- RMO Electrical & Mechanical services at DC(E) LM Bund road Shastri Nagar Delhi. (SH: Servicing/Overhauling and running maintenance of WTAC, STAC, Tower AC, Cassette AC, Water coolers, Ductable AC and AHUs) NIT No.:115/EE(E)/PWD M-253/2025-26 Estimated Cost:-16,13,606/- Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Sub Head Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Sub-Head- I (Servicing & Repairing)Servicing of Window type AC's, Split type AC's, Cassette Type AC's, Tower type AC's and Water coolers units of different capacities installed at different location i/c cleaning of condenser & evaporator coil fins, cleaning of complete unit, fan, blower, grill etc. with suitable chemical like coil shine / Veni clean etc. & high pressure water pump, oiling/greasing of blower and condenser motor, checking and tightening of electrical connections, replacement of wornout minor defective parts like capacitors, lugs, connectors, relays, thermotat, internal wire etc. i/c dismentaling and reinstallation where ever required, testing etc. complete as required. |
| 3 | Servicing of AHUs of 6500/12500 CFM Capacity units i/c cleaning of condenser & evaporator coil fins, cleaning of complete unit, fan, blower, grill etc. with suitable chemical like coil shine / Veni clean etc. & high pressure water pump, oiling/greasing of blower and condenser motor, checking and tightening of electrical connections, replacement of wornout minor defective parts like capacitors, lugs, connectors, internal wire etc. i/c dismentaling and reinstallation where ever required, testing etc. complete as required. |
| 4 | Supplying & replacement of following capacity reciprocating / rottary type hermetically sealed compressor complete in the existing WTAC / STAC unit i/c repairing / rejoining of copper pipes, replacement of capillary tube & strainer i/c credit for old dismentle material under buy back etc. complete as reqd.1.5 TR capacity |
| 5 | 2.0 TR capacity |
| 6 | 5.5 TR capacity |
| 7 | Supplying & charging Refrigerent R-22 / R-410a in the following type/capacity AC units i/c leakage testing, repairing the leakage, pressure testing, flushing the complete system, vacuumising etc complete as required.Water Cooler/ Split / Window type AC 1.5 TR capacity |
| 8 | Split / Window /Cassette Type AC 2.0 TR capacity |
| 9 | 5.5 TR Outdoor units of Ductable AC |
| 10 | Supplying and replacement of following defective spare parts in the existing Split/window/cassette AC unit with new one i/c connection testing etc. complete as required. (Credit of old and dismantle material to be retained by contractor)Normal PCB |
| 11 | Fan Motor |
| 12 | Inverter PCB |
| 13 | Supplying & Fixing of following size copper refrigrent pipe with insulated in the existing 1.5/2.0 TR Split type air conditioners complete with connection with indoor & outdoor units, leak test etc as required.Copper pipe 1/4\\" dia with 19mm insulation |
| 14 | Copper pipe 1/2\\" / 5/8\\" dia with 19mm insulation |
| 15 | Supply & laying of flexible copper conductor cable of 3 core X 2.5 sqmm size for electrical connection of indoor and outdoor units & main supply of Split/window type AC units as required at site. |
| 16 | Supply & fixing of 25mm size threaded drained pipe for AC unit from complete with elbow, socket, plastic bond & necessury clamping etc. along with the wall for proper support etc. as required. |
| 17 | Shifting of existing installed Window AC by dismantling it from its installed position and reinstalling it to a new location including cutting the window/grill (as required) including connection complete etc as required. |
| 18 | Shifting of existing installed Split AC by dismantling it from its installed position and reinstalling it to a new location i/c fixing of wall/floor bracket (as required) including connection complete etc as required. |
| 19 | Supplying and replacement of following defective spare parts in the existing 11TR Ductable AC unit with new one i/c connection testing etc. complete as required. (Credit of old and dismantle material to be retained by contractor)Cooling Coil |
| 20 | Blower |
| 21 | 3 Phase 1Hp Motor |
| 22 | Sub-Head- II (Day-to-day Maintenance)Day-to-day maintenance of Window type AC's, Split type AC's, Cassette AC's, TowerAC's and Water Coolers units of different capacities (Aprox. 87 Nos.) on all working day of month excluding sundays & holidays and attending day to day complaints by deputing sufficient technical staff including rectification of deficiency, supplying & replacement of parts like fan blade & blower, capacitors, connectors, relay, thermostat, wire, lugs, filter etc. and repairing of PCB which ever found defective during maintenance period as per requirement at site (excluding compressor, PCB, Motor, Evaporator & Cooling Coils, Grill and charging of refrigerent) including cleaning of filters etc. complete as required. [Note:- Comprehensive maintenance will start after 15 Days of Servicing of AC] |
| 23 | 5 Nos.) on all working day of month excluding sundays & holidays and attending day to day complaints by deputing sufficient technical staff including rectification of deficiency, supplying & replacement of parts like fan blade & blower, capacitors, connectors, relay, thermostat, wire, lugs, filter etc. and repairing of PCB which ever found defective during maintenance period as per requirement at site (excluding compressor, PCB, Motor, Evaporator & Cooling Coils, Grill and charging of refrigerent) including cleaning of filters etc. complete as required. [Note:- Comprehensive maintenance will start after 15 Days of Servicing of AC] |
| 24 | Supplying , Installation, Testing and Commissioning of AirCooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealedcopper Refrigerant piping with insulation (closed cellelastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU toODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase ACsupply capable of performing cooling, dehumidification, aircirculation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% ofthe rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressorand Printed Circuit Board (PCB). Must comply : Electricalcable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329,capacitor IS 2993 and motor IS 12615. Complete as perCPWD specification and IS : 1391 Part II 2023. The systemshall be able to operate up to 50 0C (out door ambienttemperature).1.5 TR with 5 Star BEE Rating |
| 25 | 2.0 TR with 5 Star BEE Rating Total in Figures 1613606.0 36150.0 Sixteen Lakh Thirteen Thousand Six Hundred & Six Only Quoted Rate in Figures Select 0.0 0.0 INR Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |