| 1 | Providing, laying, testing & commissioning of 'B' class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as requireda) 32 mm |
| 2 | b) 50 mm |
| 3 | c) 65 mm |
| 4 | Supplying, fixing, testing and commissioning ofbutterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as requireda) 50 mm |
| 5 | b) 65 mm |
| 6 | Supply, Installation, Testing and Commissioning of 5 H.P. submersible borewell pumpset having a discharge range of (45-100)LPM ±10% tolerance for head range of (18-82)metre±10% tolerance suitable for operation on 415 Volt, 50 HZ A.C. supply etc. as reqd.(For Stand By) |
| 7 | Supplying, Repairing & Replacement of following accessories for 5/7.5/10 HP capacity Mono-submersible/ Submersible motor pump set i/c dismantling old defective parts, testing, commissioning etc. as reqd. i) Remetalling & grinding of shaft - 1 no. ii) Turning & polishing of rotor sleeve - 1 no. iii) G.M. Bush - 4 nos. iv) Thrust bearing with thrust plate - 1 set v) Rubber water seal - 1 no. |
| 8 | Rewinding, Servicing and overhauling of following size Submersible/Mono submersible/monoblock pumpset with copper rewinding wire, replacement of mechanical seals, sleeve shaft, O ring, ball bearings, cast iron impeller, delivery casing, water proof cable joint, gaskets, lining seals, all lugs, minor wiring, nut bolt sets of pump and base mounting frame, applying one or more coats of red oxide primer & enamel paint all over base frame including oiling, greasing of all parts, incl. dismantling of pumpset from site, cartage from site to work shop and return back to site, cutting the burnt winding wire (i/c credit for old winding wire) along with installation, testing & commissioning etc. as reqd. at site. a) 10 HP(Water supply Pump)-2 No+(Fire Pump)-2 No |
| 9 | Supplying and Fixing of fully automatic Star delta starter panel box, suitable for upto 10 HP Motor pump set (Heavy duty) comprising of over heat relay ,Contactor + OLR,Phase sequence corrector relay,voltmeter, ammeter, push buttons, indication Lamp, 3 position selector switch, manual SPP auto in new panel complete with internal wiring etc as reqd. |
| 10 | S/I/T/C of Starter Control panel for 3 phase motor upto 7.5 HP having DOL starter of relay range 9 to 14 Amp. on the wall mounting comprising of contactor, relay, single phase preventor, auto-manual On/Off voltage selector switch, voltmeter, ammeter, push buttons etc. as reqd. (For Exisitng pump at old builidng side) |
| 11 | Supplying & fixing 3 x 6.0 sq.mm. submersible flat cable coppper conductor cable of grade 1.1 KV including connection,testing etc. as reqd a)3 x 6.0 sq.mm. |
| 12 | b) 3 x 4 sq.mm. |
| 13 | c) 3 x 2.5 sq.mm. |
| 14 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. a) Group C |
| 15 | Supplying & Fixing of 6mm Dia Steel rope forsupporting of pump sets in deep bore well etc. as.Reqd. |
| 16 | Lowering of upto 3/5/7.5/10/20 HP Mono Submersible/Sewage/ Submersible P/set along with G.I. pipe in existing well/underground tank with the help of chain pulley and tripod etc. as reqd. |
| 17 | Taking out of upto 3/5/7.5/10/20 HP Mono Submersible/Sewage/ Submersible P/set along with G.I. pipe in existing well/underground tank with the help of chain pulley block and tripod complete as reqd. |
| 18 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 19 | d) 63 A, 10 KA , TP MCB (C-Curve) (For Vertical TPDB) |
| 20 | Supplying, installation, testing & commissioning of emergency light in sheet steel body enclosure with hanging bracket arrangement duly powder coated having 2 nos. beam LED lamps of nominal lumen output of 1000 lms each with suitable size 12 volt rechargeable battery having back up of 4 to 5 hours including LED backlit asrylic signage of \\"EXIT\\" text in approved colour along with hanging bracket arrangement in housd etc. as reqd(for PUMP room) |
| 21 | Design , Fabrication, supplying installation testing and commissioning of CPRI approved outdoor type, double Door cubical feeder pillar of suitable size & made out of M.S sheet 2 mm thick (14 SWG) duly compartmentalised front openable double door with locking arrangement (2 nos. Godown locks in front ), provision for protection from rain, dust, fixed on M.S. angle iron frame work of suitable size duly grouted in cement concrete 1:2:4 (1 cement 2 sand: 4 stone aggregate) and having following accessories mounted inside the cubical panel i/c connection, inter connection with copper lead / strip with thimbles, earthing with two nos. earth studs duly powder coated with seven tank process approved colour complete etc. as reqd i/c supplying & fixing of following accessories including connection, testing etc. as read. |
| 22 | Providing and fixing following rating and breaking capacity and pole MCCB/TPN/SPN MCB with thermomagnetic release and terminal spreaders & associated switchgears in the above cubical panel board/TPDB including drilling holes in cubicle panel, fitting strips for MCB ,making connections, etc. as required. a) 100 A, 16 kA, TPMCCB |
| 23 | b) 63 A, 10 KA , TPN MCB (C-Curve) |
| 24 | c) Digital Ammpere |
| 25 | d) Digital Voltmeter |
| 26 | e) LED Indication lamps (RYB) with 6 Amp. SPMCB - 1 Set (1 set of 3 nos.) |
| 27 | Refilling of ABC type fire extinguishers following capcity carrying to workshop and after refilling reinstallation at same site as per site required. a) 50 Kg |
| 28 | Dismantling existing fire extinquishers and refilling of following capacity and type from installed position removing old gas/other extinguishing material from cylinder hydraulic pressure testing taking to workshop,refilling of gas/catridge/other extinguishing material,pasting of stickers,bring back to site and reinstalltion etc as required. a) ABC powder type fire extingusher 6 kg capacity |
| 29 | b) Co2 gas type fire extinguisher 4.5 kg capacity |
| 30 | Providing and fixing Powder Fire Extinguisher (Stored Pressure type) Capacity 06 Kg duly ISI marked conforming to IS: 15683:2006, with IS 4308, ISI marked ABC powder complete with squeeze grip release valve, discharge pipe, locking arrangement, pressure gauge,operation manual and bracket. Operating Temperature: 30ºC to + 60ºC. complete including testing and commisioning etc as required. |
| 31 | Providing and fixing CO2 type Fire Extinguisher ISI marked conforming to IS: 15683. Capacity 4.5 Kg Complete with delivery hose horn, wheel type release valve, locking arrangement, operation manual and bracket. Operating Temperature:- 30ºC to +60ºC.testing and commisioning etc as required |
| 32 | Repairing of existing Main/ Sub panel Dismantling / Disconnection of All Cable Connection from bus bar MCCB, removing all melted/ Damaged aluminium/ Copper bus bar solid connection link to switchgears cleaning of all terminals of MCCB/ MCB Bus bar with thinner CTC removing carbon dust dirt by sand paper including replacement of al damaged aluminium/ Copper bus bar solid connection link, suitable for 250 & 100AMp MCCB with Fabrication, Drilling, Replacing defective nut, Bolt, washer i/c interconnection with suitable size wire/ solid connection FRLS copper wire for MCB and reconnections all the cable to bus bar/ MCCB after repairing the Main/ Sub panel, Providing missing front cover i/c painting of panel with enamelled paint and making good the same for suitable for 415 Volt 50Hz AC supply complete with testing Etc as reqd. (For Ground Floor Distribution) |
| 33 | Credit back of dismantle material Rusted/leakage GI weight |
| 34 | rusted valve/butterfly/sluice/NRV |
| 35 | Dismental pannel |
| 36 | Dismental exixt signage |
| 37 | Dismental fire extingusher Please Enable Macros to View BoQ information |