| 1 | CIVIL WORK |
| 2 | Earthwork in excavation upto 1.50mtr depth of foundation trenches for columns, basement, tie beams, walls and steps in all kinds of soil including moorum, hard stony earth, earth mixed with boulders etc but not requiring blasting with initial leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, design including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge. |
| 3 | Filling foundation trenches and plinth with excavated earth including laying the earth in layers not exceeding 23.5cm (9”) thick ramming and watering with all leads and lifts including cost of all labour, T&P etc. complete as directed by the Engineer-in-charge. |
| 4 | Supplying and filling the Foundation & Plinth with clean coarse river sand of approved quality from approved quarry, laying in layers not exceeding 150mm thick, watering and ramming including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete as per direction of the Engineer-in-charge. |
| 5 | Providing & laying cement concrete of prop. (1:3:6) in foundation bed and floors using 40mm nominal size down graded, screened, washed hard black crusher broken granite metal of approved quality & from approved quarry including laying in the layers not exceeding 100 mm thick, hoisting, lowering, laying, watering and curing etc. complete to the required levels including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete and as per direction of Engineer-in-charge. |
| 6 | Providing and lying plain cement concrete of (1:2:4) in foundation and floors using 12 mm. Size black hard crusher broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties of all materials and cost of all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-Charge. |
| 7 | R.C.C. work of M-25 for foundation having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. |
| 8 | R.C.C. work of M-25 for plinth beam having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. |
| 9 | Providing & fixing TOR Fe-500 D grade reinforcement bars of approved makes as per DTCN for RCC work of required diameter with straightening, cutting, bending, binding welding and joining (if necessary) and tying the grills and placing in position as required for R.C.C. work and providing fan hooks, hoisting, lowering and laying including cost, conveyance and taxes of tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all heights as per the drawing, design and direction of Engineer-in-charge. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement.) |
| 10 | Brick work in foundation and plinth with flyash bricks in cement mortar (1:6) with best quality bricks having crushing strength not less than 75 Kg/cm2 immersing the bricks in water for not less than 6 hours before use (the bricks shall be well burnt, free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. and as per direction of Engineer in charge. |
| 11 | Providing 30cmx30cm size industrial vitrified floor tiles of premium grade of approved make having thickness 8mm to 10mm, conforming to IS 13755 for ceramic tile flooring of approved quality, colour and size in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient, grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as directed by the Engineer-in-charge. |
| 12 | Supplying and fittng fixing of the 12mm thick Tecttile of size 300x300mm for physical handicapped person to indicate the correct path to follow and to give a warning signal as per specification and guideline provided by Chief Commissioner for person with disability laying in floors and treated on step, landing etc on 20mm thick cement mortar (1:4) bed of tiles with cement slurry mixed with pigmetal to match the shed etc complete including cost of all materials, labour, labour cess, royalities, conveyance and T&P etc complete in all respect as directed by Engineer-in-charge. |
| 13 | Supplying and laying of M40 grade heavy duty factory made hydraulically pressed and mechanically compacted free cast interlocking coloured pavers of 80mm thick in approved pattern, coral shaped preparation of sub base with 50mm sand and leveling,laying of interlocking paver block with sand binding and final compaction with plate vibrator finishing the surface including cutting of blocks at the edges with all labour and materials etc complete as per direction of Engineer-in-chrge. |
| 14 | Providing 12mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) finished smooth to outside smooth surface after racking out the joints including watering and curing, rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as desired by the Engineer in charge. |
| 15 | Painting to external surface of building with two coats of weather coat over a coat of primer of approved shade and quality of approved design, after cleaning by watering & removing the dirts etc. to the surface to be painted including watering, curing, cost, conveyance and taxes of all materials, cost of all labour, brushes, T&P etc. and necessary scaffolding work complete as directed by the Engineer-in-charge. |
| 16 | Providing and fixing of stainless steel chair including buffing and polishing etc complete as per direction of Engineer-in-charge. |
| 17 | Supplying and fixing of SS dustbin set with stand including buffing and polishing and cost of all materials, labour, T&P etc complete as per direction of Engineer-in-charge. |
| 18 | Providing and fixing stainless steel (Grade 304) structures made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the section with necessary acessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 19 | Providing and fixing of fixed Panel including cost of materials,transportation to site etc all complete, etc all complete as per the direction of Engineer-in-charge. |
| 20 | Providing and fixing of City Map Panel including cost of materials,transportation to site etc all complete, etc all complete as per the direction of Engineer-in-charge. |
| 21 | Providing and fixing of Facia including cost of materials,transportation to site etc all complete, etc all complete as per the direction of Engineer-in-charge. |
| 22 | Supplying and fixing retro reflective stickers of approved size and colour showing subject maters, symbols etc in existing stainless steel surface including cost of all materials, labour etc complete as per direction of Engineer-in-charge. |
| 23 | Providing and fixing 8mm thick toughened clear glass of approved make inside ss signages including cost of all materials, labour etc complete as per direction of Engineer-in-charge. |
| 24 | Providing and injecting chemical emulsion for pre - constructional antitermite treatment as per IS specification and creating a chemical barrier in bottom and sides of foundation trenches, top-surface of plinth filing junction of walls and floors along with external perimeter of the building expansion joints surrounding the pipes and cables etc. complete using approved quality of chemical emulsion of requisite quantity prescribed by the manufacturer as directed by the Engineer-in-charge including cost of all materials and labour etc. complete. (Measurement should be taken as per plinth area and indemnity bond for warranty for 10 years to be furnished) |
| 25 | Supplying all labour, T&P for the Carriage of excavated earth by mechanical means of transport within 5.00 K.M. lead including hire and running charges of vehicles, labour charges for loading and unloading as required for the work etc. complete as per the direction of the Engineer-in-charge. |
| 26 | ELECTRICAL WORK |
| 27 | Wiring:- Wiring to light points/fan point/exhaust fan point/Call bell point with 1.5-sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non metalic PVC flexible condute with 6Amp, 250V Modular Switch ISI marked and ceiling rose ISI marked mounted on Metal box having front Modular cover of suitable size, metal box with 1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. (Make of wire-Finolex/ L&T/ Anchor/ Havells/ KEI). 1) Primary point |
| 28 | 2) Secondary point |
| 29 | Submains:- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed 2mm thick PVC rigid conduit pipe as required complete as per direction of engineer in charge. a) 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. |
| 30 | b) 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. |
| 31 | Controll Panel & BDB :- Supply, delivery, installation, testing & commissioning of L.T. outdoor (IP 65) wall mounted type main distributiob board with lock & key arrangement made out of 2 mm thick stainless steel sheet cubicle with dressing and ferruling, the cabinet have a common bus bar, dust, damp & vermin proof having hinged door and compartmental arrangement for each equipment duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge. a) Supply & fixing of IP 65 IK 09 8 Module Distribution Board with connector complete as per the direction of Engineer-in-charge. |
| 32 | b) Supply & fixing of IP 65 IK 09 6 Module Distribution Board with connector complete as per the direction of Engineer-in-charge. |
| 33 | c) Supply & Installation of 6-10A SP MCB complete as per the direction of Engineer-in-charge. |
| 34 | d) Supply & Installation of 32A DP MCB complete as per the direction of Engineer-in-charge. |
| 35 | e) Supply & Installation of 9 to 18 A contactor complete as per the direction of Engineer-in-charge. |
| 36 | f) Supply & Installation of digital timer complete as per the direction of Engineer-in-charge. |
| 37 | g) Supply & fixing of power supply control panel (SMPS) of 150 watt water proof of IP65 with connector complete as per the direction of Engineer-in-charge. |
| 38 | Cable Laying :- Supply and laying of following size of XLPE insulated & PVC sheathed Armoured Aluminium power cables ISI marked complete as per the direction of Engineer-in-charge. a) 2c x 4 sqmm Armoured Aluminium A2XWY Cable |
| 39 | Earthing :- Construction of earthing chamber including installation of earthing pipe. Making earthing chamber including excavation, soil treatment with bentonide powder, calculation of earth resistance, including installation of 3 mtr GI pipe 40 mm/50 mm including welding of GI falt around pipe. |
| 40 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 41 | Fittings & Fixtures:- Supply, Installation, testing & commissioning of following types of light fixtures directly on wall / ceiling of building with all accessories such as drivers, lamps cover etc complete assembly including supply of all accessories and making connection from the suitable point outlet complete as per the direction of Engineer-in-charge. a) Supply, Installation, testing & commissioning of 20 watt (60 cm) batten LED light complete as per the direction of Engineer-in-charge. |
| 42 | b) Supply, Installation, testing & commissioning of 10 watt IP 66 surface mounted LED light complete as per the direction of Engineer-in-charge. |
| 43 | c) Supply, Installation, testing & commissioning of 1.5 watt LED Module complete as per the direction of Engineer-in-charge. |
| 44 | Statutory diposit to be made to TPCODL upto the metering unit. (as per actual) Please Enable Macros to View BoQ information |