| 1 | Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-P |
| 2 | Secandary point wiring for additional light/ bell point in PVC trucking (casing-capping) with 1.5 Sq.mm (2+1E) FRLSH grade copper wire with requrired accessoriesas per specification |
| 3 | Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm(2+1E) FRLSH grade copper wire, modular type switch, earthing andrequired accessories as per specification No: WG-PW/SW |
| 4 | Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/S |
| 5 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 6 | S & L rigid PVC Conduict of size 20 mm with accessories on wall/celling as per specification |
| 7 | Supplying and erecting modular type 3 pin 6A multi socket with safetyshutter, duly erected on provided plate and box with wiring connections |
| 8 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safetyshutter, duly erected on provided plate and box with wiring connections complete.E |
| 9 | Supplying & erecting ready to use Retrofit T8 LED 18 / 20 tube light withpolycarbonate body, heat sink, integrated HF electronic driver complete &compatible to T8 / T12 LED luminaire by disconnecting starter & ballast ifnecessary. |
| 10 | Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B-22 /E-27 base. |
| 11 | Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position with regulator as per specification no. FG-FN/CF |
| 12 | Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x75 mm long with necessary materials for ceiling fan. |
| 13 | Supplying and erecting' B' class GI pipe MS. Pipe down rod duly painted for complete erected with PVC three core Flexible cable 1 Sq.mm copper PVC |
| 14 | Supplying and erecting Cabin fan 230 V A.C. 50 cycles 400 mm Sweep complete erected in position with necessary bracket for fixing cabin fans, wire |
| 15 | Supplying and erecting energy saving air cum exhaust fan of light duty 250 V A.C 50 cycle 225mm 1400 RPM rust proof body & Blad , wire mesh , duly erected complete |
| 16 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or anyother places as per specification No: WG-MA/BW |
| 17 | Supplying & erecting mains with 2x2.5 sq.mm.and earth wire 1.5 sq.mm FR PVC copper wire, in rigid PVC conduit min.20mm dia,as per specification No: WG-MA/PC, para no. 1.4.1 |
| 18 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.as per specification No: WG-MA/BW |
| 19 | Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVCinsulated wire laid in provided onduit/ trunking/inside pole/Bus bars or anyother places as per specification No: WG-MA/BW |
| 20 | Supplyinganderectingmodular typeswitchoneway16/20A, dulyerected on provided plate and box with wiring connections complete with neon indicator. |
| 21 | Supplyinganderectingmodular type32A,DPkeytagswitch with keytag, duly erected on provided plate and box with wiring connections complete. |
| 22 | Supplying and erecting modular type 3pin6Amulti socketwithsafety shutter, duly erected on provided plate and box withwiring connections complete. |
| 23 | Supplyinganderectingmodulartype3pin6/16Amulti socketwithsafety shutter, duly erected on provided plate and box withwiring connections complete. |
| 24 | Supplying and erecting PVC Surfacemodular switch box with double mounting plate for 3 module duly erected. |
| 25 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected. |
| 26 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 27 | Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 28 | Supplying, erecting and marking Four pole isolator only switch version ofminiature circuit breaker of 80/100 A with required wiring connections and lugs etc.in provided distribution board. |
| 29 | Supplying and erecting metal work in CRCA sheet including Iron work forsupports with fabrication of boxes, panel boards, etc. including cutting,bending, drilling, welding, riveting, treated with anti-rust treatment and dulypowder coated or painted with one coat of red lead paint and 2 coats of enamelpaint complete. |
| 30 | Supply & laying PVC/ armoured aluminium conductor cable 1100 V grade ISI Mark a. 2 X 6 Sq mm |
| 31 | e. 4 X 16 Sq. mm. |
| 32 | g. 3.5 X 35 Sq. mm. |
| 33 | Supplying & laying (including excavation of road) 50 mm. outside dia. DWC Pipe. |
| 34 | Providing Cement Concrete foundation for concrete filling in with 20 to 25 mm. Stone metal duly plastered with necessary curing for pole muffing or any other purposes.a. Concreting 1:3:6 |
| 35 | Supplying and erecting LED square / circular Max. 14 W downlighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 36 | Supplying and erecting plywood 6mm thick fixed to wall or on provided pannel bord with necessary materials such as screw, wall fasters supports, Nuts bolts etc. complete. |
| 37 | supplying & ercting GI pipe \\"A\\" grade of following dia for erection of armoured cable b) 40mm |
| 38 | Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protections as per specification no. AP-UPS |
| 39 | Supplyinganderecting12V/65AhSMFbatterywithbatteryterminalwire,duly charged with 24 months warranty complete |
| 40 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation &temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC |
| 41 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room airconditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation &temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC |
| 42 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erectedon angle iron/GI frame. |
| 43 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 44 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 45 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 46 | Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete asper specification no. SW-RCCB/RCCB |
| 47 | Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 48 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as perspecification no. SW-SWR/MCBDB |
| 49 | Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 40A in provided distribution board. |
| 50 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC |
| 51 | S u p p l y i n g & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg.capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 52 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 42mm complete Please Enable Macros to View BoQ information |