| 1 | Sub Work No.1- 10 KLD Leach pit (Total Leach pit No.2 = one Leach pit Rs.32730.35 = 3 Leach pit Rs.98191.05)Excavation for foundation/pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) -Excavation work (0.0-1.5m) |
| 2 | Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) - Excavation work (0.0-1.5 M) |
| 3 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 4/259) - Excavation work (0.0-1.5 M) |
| 4 | Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) |
| 5 | Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. |
| 6 | Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 7 | Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) |
| 8 | Providing and fixing in position steel fibre reinforced concrete (S.F.R.C.) frame and covers of approved make including loading, unloading, transportation, all taxes, etc. complete as directed by Engineer in charge (20 tonnes capacity). 0.90 m X 0.60 m |
| 9 | Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).110 mm. |
| 10 | Subwork No -02 ( 75 KLD STP based on CAMUS Tec hnology) Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA1/259)0.0 to 1.5 m |
| 11 | 1.5 to 3.0 m |
| 12 | 3.0 to 4.5 m |
| 13 | Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA3/259)0.0 to 1.5 m |
| 14 | 1.5 to 3.0 m |
| 15 | 3.0 to 4.5 m |
| 16 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA 4/259)0.0 to 1.5 m |
| 17 | 1.5 to 3.0 m |
| 18 | 3.0 to 4.5 m |
| 19 | Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering, excluding backfilling, etc. complete by all means. (BdA6/259)0.0 to 1.5 m |
| 20 | 1.5 to 3.0 m |
| 21 | 3.0 to 4.5 m |
| 22 | Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (BdA12/264)Soling |
| 23 | Providing and laying in situ Cement Concrete M15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) PCC |
| 24 | Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 25 | Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineerincharge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)For Beams / Braces / Lintels In RCC M300 |
| 26 | Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineerincharge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)Slabs / Landings / Vertical Walls / Waist Slabs / Steps for Staircase In RCC M300 |
| 27 | Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineerincharge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)Chajjas / Parapets / Curtain Walls /Partition Walls / Pardies In RCC M300 |
| 28 | Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (BdF17/306)c) Corrosion Resistant Steel (Fe 500) |
| 29 | Providing and fixing mild steel grill work for windows/ ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (BdU1/537) |
| 30 | Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11 / 2:3 including scaffolding and fourteen days curing complete. |
| 31 | Providing and applying whitewash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. |
| 32 | Providing and applying colourwash of approved colour and shade in one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc. complete. |
| 33 | Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineerincharge (including cost of machinery, labour, fuel), etc. complete. (BdA9/261) |
| 34 | Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. |
| 35 | Transportation as per STATEMENT VI Including loading, unloading and stackingEarth (4.8 Cum) lead 15 Km |
| 36 | Electromechnical ItemsScreen (Manual) of size 1.6 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200mm straight and 50mm of 90 degree bendQuotation Item |
| 37 | Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as belowGrit Pump1 HP (Up to 9000 LPH) Supply |
| 38 | 1 HP (Up to 9000 LPH) Erection |
| 39 | Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as belowRaw Sewage Pumps2 HP (Up to 12000 LPH) Supply |
| 40 | 2 HP (Up to 12000 LPH) Erection |
| 41 | NaOCl ChlorinatorPump Diaphragm Type / peristaltic type / Solenoid Max Flow Rate Upto 10LPHPower Source Electric Phase SingleMaterial PP / PTFE(Teflon) Voltage 230 Volt Frequency 50HzMixing Tank of 100 Ltrs capacity 1 No Dosing Pump 2 NosQuotation Item |
| 42 | Designing, Supplying, Installing, commissioning & testing of PLC Panel.Including PLC with CPU & Power supply unit, power supplyb cables interfacing cards, interfacing cables, wireless modules with 25% extra quantity of all accessories.Control PanelQuotation Item |
| 43 | Supplying and erecting Fully Automatic Star Delta starter to operate squirrel cage induction motor working on 380 440 Volt, 3 phase, 50 Hz with no volt coil, over load element, and ON OFF push buttons, with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser.> 7.5 HP & Up to 12.5 HP |
| 44 | Erection |
| 45 | Main power supply cable3 core PVC insulated, PVC sheathed copper conductor flat submersible cable.Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed.3 core 16 sq mm Supply |
| 46 | Erection |
| 47 | Power cablesAluminium conductor 4 Core, XLPE / PVC insulated & armoured cableSupplying and erecting, XLPE/PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall / on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.4 Core 6 sq mm Supply |
| 48 | Erection |
| 49 | Control Cables Copper conductor PVC insulated, Unarmoured control cableSupplying and erecting Unarmoured control cable with ISI mark stranded / solid copper conductor 1.1 kV grade complete erected on wall / panel or in provided trench in an approved manner.4 core 2.5 sq mm Supply |
| 50 | Erection |
| 51 | Plumbing ItemsProviding and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).Raw Sewage pump to CAMUS DistributionMain header& Camus Collection75 mm. |
| 52 | PVC Specials 5% |
| 53 | Distribution , collection tributory &CAMUS distribution63 mm. |
| 54 | PVC Specials 5% |
| 55 | LabourPlumber |
| 56 | Helper |
| 57 | Providing double flange sluice valve confirming for IS 14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete. Sluice valves PN 1 (Without by pass)Raw Sewage pump80 mm. |
| 58 | Lowering, laying and jointing in position following C.I.D/ FReflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nutbolt sand giving satisfactory hydraulic testing etc. complete.(Rateforallclassofvalves.) i) 50mm. |
| 59 | Providing and supplying ISI mark CI D/F reflux valves (non return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984)Without by pass arrangement PN 1Raw Sewage pump80 mm. |
| 60 | Lowering, laying and jointing in position following C.I.D/ FReflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nutbolt sand giving satisfactory hydraulic testing etc. complete.(Rateforallclassofvalves.) i) 50mm. |
| 61 | Bio media ItemsSupplying crushed metal 60 to 80 mm of trap/granite/quartzite/gneiss stone metal at the site including conveying & stacking . 15 Km Lead. Also Laying into Bio Mound Tank |
| 62 | Supplying crushed metal 20mm of trap/granite/quartzite/gneiss stone metal at the site including conveying & stacking . 15 Km Lead. Also Laying into Bio Mound Tank |
| 63 | Supplying 40 to 60mm of Hard Murrum at the site including cleaning and laying into Bio Mounds |
| 64 | Providing and fixing Jute Kanthan (Tarat) sceen to the scaffolding for external guniting as directed including removing the work is over etc.completeJute |
| 65 | Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 30 cms. (consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.36a), Supplying on site well decomposed Farmyard Manure for excavation area of depth of 30 cms. (Consolidated thickness). (As per P&G DSR 2022 - 23 Items of garden work, Sr No.36b), Providing on site required variety of lawn (free from weeds / diesease etc.) Cynadon/ paspalum/ selection for 1 sqm. area dibbling distance 5 cms. apart c/c. ( As per P&G DSR 2022-23 Items of garden work,Sr No.46) |
| 66 | Supply, Installation and Testing of Tube Settler PackingTube Settler |
| 67 | Providing supplying culture Catalyst & On site demostration as per the M/s Vision Earthcare Pvt Ltd all as specified including MOU with technology expert M/s Vision Earthcare Pvt Ltd CAMUS Patent No 414339 Technology Consultancy Charges (General Arranagement and Hydraulic Flow Diagram Design and Drawings), CAMUS Cultures, CAMUS Catalyst,.Maharashtra GO No. Serial No 2017/Sch No351/UDD33 1 dated 27 Feb 2018Process Design, GA drawings, HFD, PFD, Equipment Specs (Make: SAI/VEC/Eqv)Acarine Orbatid Soil Mite Cultures Patent No. 202121021680 (Make VEC/SAI/Eqv)Oxygenation Catalyst (Make VEC/SAI/Eqv)Fungal Growth Factor (Make VEC/SAI/Eqv)culture Catalyst |
| 68 | Supply, Installation and Commissioning of Solar Power System Solar Inverter 5 kw- 1 No., Solar panels- 3 kw, Solar PV Panels, Fabrication- 1 Set, Tubular Battery 120V, 100Ah, Lighting Arrester, DC & AC Cable, Connectors, Earthing, other electric material, etc.- LS Solar Power System (Part -A)Supplying, installing, testing and commissioning of 3 kWp ON-GRID Solar PV Each System / Plant consisting solar PV poly crystalline panel (335 Wp X 09 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, twodistinctearthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS system, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenancecontractasperspecification no. ESD-RT-ONG |
| 69 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU=242 + 5% |
| 70 | FOUNDATION AND G.I. STRUCTURE FOR PV MODULE (Part -B)Solar PV mounting structure hot deep galvanized/pre galvanized with necessary fitments which should withstand high wind velocity upto 150km/hrExcavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259). |
| 71 | Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259) |
| 72 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below,stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 4/259) |
| 73 | Excavation for foundation / pipe trenches in hard rock by controlled blasting, including trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete. (Bd-A- 5/259) |
| 74 | Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264)Soling |
| 75 | Providing and laying in situ Cement Concrete M15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. Bd E /1 Page No. 287 and B 7, Page No. 38PCC-M15- |
| 76 | Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) RCC-M20Footing |
| 77 | Providing and casting in situ Cement Concrete of trap/ granite / quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineerin- charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)Column |
| 78 | Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineerincharge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)Beam |
| 79 | Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (BdF17/306)c) Corrosion Resistant Steel (Fe 500) |
| 80 | Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263) |
| 81 | For structure Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates, etc. as per detailed design and drawing or as directed by Engineer-in- charge including cutting, fabricating, hoisting, erecting and fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc. complete. (Bd-C-8/278) |
| 82 | For structure (LESS Painting Charges) Providing and applying two coats of oil paint and one coat of primer/red oxide of Iron Paint externally including cleaning the surface of pipe with steel scrapers wire brushes and metal cleaning solution etc complete. |
| 83 | For structure Providing and applying material & labour for hot dip galvanizing of above structure including transportation for galvanizing as per R.C |
| 84 | For structure- Transporting charges of vehicle per trip for Appox. 50 km ead including loading unloading & stacking charges. |
| 85 | Rent for Crane for erection of structure- |
| 86 | Providing and erecting chain link fencing 1.6M. height with G.I. chain link of size 50x50mm, 8gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40x40x6 mm size, including excavating pits for foundation and embedded in C.C. block of 1:4:8 mix of size 450x450x670 mm. at 1.75M. c/c with iron bar 16mm dia as hold fast including welding link with angle frame at 30cm c/c with nuts and bolts and horizontal M.S. Angles at top and bottom of 25x25x5 mm size and vertical M.S. flat 35x5 mm and 25x5 mm horizontal including cross support of 40x40x6 mm angles both side at every corner or bend embedded in concrete blocks of 1:4:8 of size 450x450x670 mm including 3 coats of oil painting etc.complete. |
| 87 | Providing and fixing 50mm. dia. medium class G.I. pipe gate with wicket gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in c.c. block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer etc. complete. |
| 88 | Providing and fixing board displaying information,such as 'Name of work,Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20mx0.90m size made out 18gauge(1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on backside and border/ messages/ symbols etc. with approved colourshade paint complete, on M.S.angle of size35x35x3mm frame with properly cross braced M.S.angles of size 35mmx35mmx3mm duly painted including Two M.S.angle iron posts of size 65mm x 65mm x 6mm, 3.65m long painted with alternate black and white bands of 25cm width including all fixtures etc.and fixing the board sin1:4:8 concrete block of size 60cmx60cmx75cm including, excavation, refilling, transportation and labour etc complete. Spec. No. As directed by Engineer in Charge |
| 89 | Providing Energy Meter application fees Please Enable Macros to View BoQ information |