| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer (EP-MM), % Sr. CE (E), BEZ, Hyderabad. Name of Work: Providing repairs to EI & Fans and UPS wiring for open office in 4th floor of Doorsanchar Bhavan, Hyderabad NIT No: 97/EE(EP-MM)/CEE/BEZH/ 2025-26 dated 28.02.2026 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER HSN Code TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. DESCRIPTION OF ITEM Item Code / Make Qty Unit Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Basic unit price exclusive of all taxes & Charges FF Packing % FF Packing Amount CGST % CGST Amount SGST% SGST Amount IGST % IGST Amount All-inclusive Unit Cost (5+7)+[(9+11) or 13] Total price inclusive of all charges (3 x 14) Amount of Input tax Credit (ITC) to be availed [(9+11) or 13] Total Amount of Input tax Credit (ITC) to be availed (3 x 16) Unit price excluding ITC amount (net unit cost) (14-16) Total price inclusive of all levies and charges but excluding ITC (net total cost) HSN for goods and SAC for services Total price inclusive of all levies and charges but excluding ITC (net total cost) TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required . a)2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire |
| 3 | b)4 x 1.5 sq. mm + 2 x 1.5 sq. mm earth wire |
| 4 | c)2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 5 | d)4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire |
| 6 | Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc., as reqd. a)5/6 A Switch |
| 7 | b) 3 pin 5/6A socket outlet |
| 8 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate as required. |
| 9 | Supplying and fixing of following sizes of medium class PVC conduit along with acessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. a)20 mm |
| 10 | b) 25 mm |
| 11 | c)32 mm |
| 12 | Supplying and drawing following sizes of FRLS / HFFR PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required.a)3 x 1.5 sq. mm |
| 13 | b) 6 x 1.5 sq. mm |
| 14 | c) 3 x 2.5 sq. mm |
| 15 | d)6 x 2.5 sq. mm |
| 16 | Installing the existing metal box consisting of 5A / 15A socket outlets / switches (Ups/Power)on existing wooden partition / wall surface including termination / testing etc., as required. |
| 17 | Supplying and fixing suitable size PVC box with modular plate and cover in front on surface or in recess, inclduing providing and fixing 1No. 5 pin 5/6A modular socket outlet and 1No. 5/6A modular switch, connections etc.,as reqd |
| 18 | Supplying and fixing suitable size PVC box with modular plate and cover in front on surface or in recess, inclduing providing and fixing 1No. 6 pin 5/6A & 15/16A modular socket outlet and 1No. 15/16A modular switch, connections etc.,as reqd |
| 19 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). a) 8 way, Double door |
| 20 | b) 12 way, Double door |
| 21 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole |
| 22 | b) Single pole and Neutral |
| 23 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc., as required. a) 63A |
| 24 | Supplying and Laying of following size Aluminium Armoured XLPE insulated and PVC sheathed power cable of 1.1 KV grade on existing cable tray / on wall etc., complete as required. a) 2 x 6 sq.mm |
| 25 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 2 x 6 sq. mm (19mm) |
| 26 | Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing as required. |
| 27 | Supplying and fixing of 36W LED Recessed full lit luminaire with glare free uniform illumination with longer life and less maintenance of size 2 ft. x 2 ft. ( more than 100 Lumen/Watt) suitable for operation on 230volts 50Hz AC supply including providing interconnections chain arrangement for hanging the fitting from ceiling etc., making good the damages done to the false ceiling etc., as required' Make: M/s Crompton Model:LCTLRNE-36-FO-CDL / SS make) |
| 28 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types along with 2Nos. down rods, complete with all accessories and tube/lamp etc., on ceiling / wall including minor repairs like replacing faulty side holders, internal wiring, cleaning, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc., as required. |
| 29 | Supplying and fixing of ball and socket, 2Nos. down rods of 20mm dia x 1.6mm thick steel conduit upto 30cm length, painting etc., as required. |
| 30 | Providing repairs to the ceiling fan by replacing the following faulty spares including servicing / transportation etc., as required. a) capacitor (1.5mfd) |
| 31 | b) bearings |
| 32 | Installation, testing and commissioning of ceiling fan including wiring the downrods of standard length (upto 30 cm) with 1.5 sq mm FRLS/HFFR PVC insulated, copper conductor, single core cable etc., as required. |
| 33 | Supplying and fixing of ceiling fan hooks including drilling hole in the ceiling and making good the damages etc., as required. |
| 34 | Supplying and Fixing of 4 feet 20W LED tube, suitable for the existing Light fitting and operating on 230V, AC supply i/c interconnections, testing etc., as reqd. (M/s Crompton/SS make) |
| 35 | Transportatoin of SMO type light fixtures, ceiling fans from BSNL Bhavan to Door sanchar Bhavan including loading, unloading and hiring of vehicle (apprx qty of light fittings: 100 nos, Ceilingfans: 50 nos.) |
| 36 | Dismantling of all old UPS wiring, computer sockets, light fittings, ceiling fans, switch boards, DB's in 3rd floor rooms & corridor (approx size 35.2 Mtrs mm X 18 Mtrs ) and shifting the removed material to basement and kept in Basement Store Room etc., complete as required. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select, Excess (+), Less (-) 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |