| 1 | Supply & Fix in replacement LED street light fitting 60 W pressure die cast aluminium IP66 roadway luminaire with high power LED as light source and electronic driver including GI bracket light grade 25/32/40 mm and provn of electric supply to fitting from junction box by means of PVC Sheathed multi-stranded aluminium conductor cable of 2.5sqmm for phase and neutral & 1.5 sqmm as earth wire incl taking down old unsv light fittings complete all as specified and directed . |
| 2 | Supply & Fixing LED Flood light fitting 150 W 230 V AC outdoor type pressure die cast aluminium IP66 luminaire with high power LED as light source and electronic drivermake in Havells with cat part no. JETALEGANZAFLS150WLED757P60DTOTG or equivalent make in Bajaj/crompton/philips with impact and corrosion resisant including clamp and GI bracket light grade and provn of electric supply to fitting from source by means of PVC Sheathed multi-stranded aluminium conductor cable of 2 x 4 sqmm core complete all as specified and directed . |
| 3 | Supply & Fixing LED street light fitting 45 W pressure die cast aluminium IP66 roadway luminaire with operating range from 80V AC to 230 V AC with high power LED as light source and electronic driver make in Havells with cat part no. ENDURASUNDOWNSL45WLED765PASYBOPC or equivalent make in Bajaj/crompton/philips including GI bracket light grade 25/32/40 mm and provn of electric supply to fitting from source by means of PVC Sheathed multi-stranded aluminium conductor cable of 3 x 2.5 sqmm core complete all as specified and directed. |
| 4 | Supply and fixing in replacement Junction Box made up of High quality thermoplastic polycarbonate enclosure with IP 66 degree of protection, weather proof, corrosion proof, dust proof, insulted and shock proof, fire retardant non toxic material with internally embedded gasket with 6 Amp MCB and 4 nos terminal of size 155x210x92 mm with terminal suitable for 10 to 16 sqmm XLPE cable of make hensel or equivalent make of Sintex/ Universal complete all as specified and directed by Engineer-in-Charge. |
| 5 | M & L for one coat of aluminium shade paint of approved quality including preparation of existing old painted surface of steel tubular poles LT complete including flat iron clamps, bracing , cross arms etc and numbering of poles with white synthetic enamel paint over a circular painted base and strip marking paint up to a height of 5 feet with black & yellow five bands with synthetic paint (strip of 1 feet height each) complete all as specified and directed. |
| 6 | S & F in replacement Timeline distribution board 32A 3 pole/230 V Astronomical timer switch Model No TL032ASO of make IndoAsian r its equivalent Make as approved by GE complete with and including mounting bracket, cable glands, openable doors with lock complete all as specified and directed. |
| 7 | Supply and Fixed in replacement errecting in true vertical position steel tubuler poles 9 meter long complete with MS base plate , MS pole cap, bolts nuts & screw as specified type 410 SP-31 with and including painting of poles with black bitumenous paint throughout the length internally and outside upto planting depth and remaining portion 2 coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed. |
| 8 | M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of steel tubular pole incl form work complete all as specified and directed. |
| 9 | M & L for PCC (1: 4:8 ) type D-2 using 40mm graded stone aggregate as in bottom of pit for bed concrete of steel tubular pole incl form work complete all as specified and directed. |
| 10 | M & L for PCC ( 1:2:4) type B-1 using 20mm graded stone aggregate as in coping including all form work complete all as specified and directed. |
| 11 | Supply & Fixing in replacement 20 watt All in One Solar Street light LED Made in India with high efficiency monocrystalline Solar PV Module, Lithium fero Phospate Battery with inbuild BMS techonology high efficacy LED ,MPPT Solar Charge Controller and aluminium extruded body having progressive inteligent diming which automatically control the diming and brightness of lights (With back up 24 Hours),including galvanised steel pole in built ,Pole length minimum 5.5 mtr,testing after installation all as specified and directed. |
| 12 | M & L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling & mass concrete including use of form work and finishing all exposed faces of concrete complete all as specified and directed by Engineer-in-Charge. |
| 13 | Excavation in trenches not exceeding 1.5 Mtr wide and not Exceding 1.5 Mtr in depth and getting out in hard/dense soil for laying cables and pole complete all as specified and directed by Engineer-in-Charge. |
| 14 | Removing excavated material not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 15 | Supply, laying and testing in replacement cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply, laying and testing in replacement cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core complete all as specified and directed by Engineer-in-Charge. |
| 17 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of underground cable and getting out in any type of soil complete all as directed by the Engineer-in-Charge. |
| 18 | Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cms. thick in soft / loose soil complete all as specified and directed by Engr -in -charge . |
| 19 | Removal of surplus soil not exceeding 50 Mtr and depositing where directs at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 20 | M&L for dry sand cushioning in trenches spreading and consolidation 8cm thick before laying the cable & 15 cm of sand after laying the cable complete all as specified.Note: Only punned thickness shall be measured for payment purpose. |
| 21 | M&L for laying of old size bricks well burnt sub class ‘B’ (old pattern) laid flat for cable protection width equal to the length of brick complete all as specified . |
| 22 | S & F in replacement galvanised steel water tubing 'light grade' 32 mm bore with all fittings laid along the wall/in trenches/in duct/in culvert/road crossing etc. and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles etc. complete all as specified and directed . |
| 23 | M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. Please Enable Macros to View BoQ information |