| 1 | Surface Excavation nexc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Excavating in trenches, n.exc 1.5m wide and n.exc. 1.5m in depth for foundation, etc. or for shaft, wells and cesspits in soft/loose soil complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 4 | Removing excavated material n, exc 50m and depositing where directed at a level n exc 1.5m from the base complete all as specified and directed. |
| 5 | M&L for hardcore of broken or boulders of guage n exc 63 mm depositedspread and levelled in layers n exc 15cm thick watered and rammed to a true surface complete all as specified and directed. |
| 6 | M&L PCC 1:4:8 type D2 using 40mm grade stone aggregate as in foundation concrete etc complete all as specified and directed. |
| 7 | M&L RCC M-25 (Design Mix) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 8 | M&L RCC M-25 (Design Mix)Concrete as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelvescomplete all as specified and directed. |
| 9 | M&L RCC M-25 (Design Mix) Beams, Cantilivers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 10 | M&L forbrick work with old size sub class \"B\" bricks straight or curved on plan exc. 6m mean radius and built in CM 1:6 etc complete all as specified and directed. |
| 11 | M&L forbrick sub class ‘B’ old size bricks, straight or curved on plan to any radius in half brick thick walls and built in CM 1:4 etc complete all as specified and directed. |
| 12 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc complete all as specified and directed. |
| 13 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; n. exc 200m thick (Horizontal or sloping) etc complete all as specified and directed. |
| 14 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed. |
| 15 | Formwork to sides of pillars, posts, struts, piers, columns, and stanchions etc complete all as specified and directed. |
| 16 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs n exc 20 cm wide & sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide etc complete all as specified and directed. |
| 17 | S&F 200 mm size aluminum anodised, barrel tower bolts of extruded section etc complete all as specified and directed. |
| 18 | S&F aluminum alloy anodised, sliding door bolts with hasp and staple, (bolt type) and fixing clips of sheets, cast or extruded section and fixing boltand sliding bolts of extruded section or cast aluminium alloy and fixed 300mm long etc complete all as specified and directed. |
| 19 | S&F 150 mm long extruded anodized aluminum alloy handles, fabricated type,etc complete all as specified and directed. |
| 20 | S & F 4.00 mm thick figured glass pin headed tupe fixed in ventillators etc complete all as specified and directed. |
| 21 | S&F Mild steel of conforming to Fe 290 grade E-165 as framed work (Angles ,Flat Iron, square/round bars) with ends of bars shouldred and/or rivetted or forged into spikes for window grills/framed guard bars to the design and pattern of ornamental and intricate as approved etc complete all as speciified and drected. |
| 22 | M&L TMTbars 10mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed. |
| 23 | All as per ser item No 22.00 above but 6mm to 8mm diacomplete all as specified and directed. |
| 24 | All as per ser item No 22.00 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and directed. |
| 25 | S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded etc complete all as specified and directed. |
| 26 | M & L for cleaning the newly plastered surfaces of concrete ( roof etc) with wire brushes and applying water proofing treatment as under :-(i) Apply Priming surfaces and applying normal treatment (for moderate conditions) using glass fibre base bitumen felt, grade 2.(ii) Providing and laying3 mm thick APP modified water proofing membrane weighing not less than 3.0 Kg / Sqm reinforced with non woven polyester mat weighing not less than 150 gm/Sqm all as specified procured from any one of the approved manufacturer\"s instructions |
| 27 | M & L Applytwo coat of aluminium paint @ 0.15 Kg/Sqm over membrane over roof surfaces complete all as per manufacturer\"s instructions and as directed . |
| 28 | M&L Cement concrete type D-2, 1:4:8(40mm graded aggregate) 75mm thick as in subbasecomplete all as specified and directed. |
| 29 | M & L for glazed ceramic coloured joint free tiles in vertical surface 450X 350X 7mm thick with and including 10mm thick CM 1:6 backing coat, set and jointed in neat cement slurry and pointed in white or colour cement to match etc complete all as specified and directed. |
| 30 | M & L forNon - skid/Glossy finish/Matt finish joint free coloured ceramic tiles 7 to 8 mm thick (square/rectangular) laid in floors area of each tile exc. 0.06 sqm but n.exc 0.11 sqm, in floors etc. with and incl 15mm thick screed bed in CM 1:6 , set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as directed. |
| 31 | M & L 25mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as floor all as per direted |
| 32 | M&L PCC 1:2:4 type B1( 20mm agg), 40mm thick laid in slope of 1:20 and alternate bays incl finished even and smooth without using extra cement and joints in the plinth protection etc complete all as specified and directed. |
| 33 | M&L 10mm thick cement plaster in CM 1:3 on ceiling surfacesfinishing the same even and smooth without using extra cement etc complete all as specified and directed. |
| 34 | M & Lfor 10 mm thick rendering in CM 1:6 on brick/ concrete surfaces and finishing the surfaces even and smooth with a thin layer of sagol etc complete all as specified and directed. |
| 35 | M&L for 15 mm thick rendering in CM 1:4 on brick/concrete external surfaces of walls sand faced sponge faced finish etc completeall as specified and as directed. |
| 36 | M&L for preparation of newly plastered surfaces of wallsand applying one coat of primer over a coat of birla white cement putty,sanding the surfaces till smooth finish is obtained and finally applying two coats of oil emulsion distemper etc complete all as specified and directed. |
| 37 | M&L for preparation of newly plastered surfaces of wallsand applying two coats of cement based paint over a coat primeretc complete all as specified and directed. |
| 38 | M&L for preparation of newly plastered surface and applying three coats of white wash on ceiling etc complete all as specified and directed. |
| 39 | M & L for preparation of new steel surfacesexc 10 cm width/girth and applying two coats of synthethic enamel paint over a coat of primer red oxide zinc chrome etc complete all as specified and directed. |
| 40 | M & L for 15 mm bore of tube medium grade Galvanised steel water tubing with all fittings and fixed complete to walls, or laid in flooretc complete all as specified and as directed. |
| 41 | All as per ser item No 40.00 above but 20mm bore pipecomplete all as specified and directed. |
| 42 | S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I etc complete all as specified and directed. |
| 43 | S&F 15mm bore bib taps, chromium plated cast copper alloy quarter turn long body screwed down, screwed for iron pipe etc complete all as specified and directed. |
| 44 | S&F for in repair swan neck pillar cock chromium plated fancy type screw with iron pipe incl all fittings complete all as specified and directed. |
| 45 | S&F 15mm bore stop valves, chromium plated cast copper alloy quarter turn long body screwed down, screwed for iron pipe with long shank and cup (concealed type) etc complete all as specified and directed. |
| 46 | S&F 20mm bore gun metal globe or gate valves with iron wheel head screwed both ends for iron pipeetc complete all as specified and directed. |
| 47 | S&F 20mm bore ball brass valves, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe etc complete all as specified and directed. |
| 48 | S&F fancy type Brass chromium plated 600mm long Towel Rod fixed with screws and wooden/plastic cleats etc complete all as specified and directed. |
| 49 | S&F PVC connections 15mm size with PTMT nuts of length 450mm etc complete all as specified and directed. |
| 50 | S&F 75mm borePVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors etc complete all as specified and directed. |
| 51 | All as per item No 50.00 above but 110mm diacomplete all as specified and directed. |
| 52 | S&F 110mm borePVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wallsetc complete all as specified and directed. |
| 53 | S&F 75mm borePVC (SWR) bends any radius with access door etc complete all as specified and directed. |
| 54 | All as per item No 53.00 above but 110mm dia complete all as specified and directed. |
| 55 | S&F 110 mm borePVC (SWR) vent cowl etc ccomplete all as specified and directed. |
| 56 | S&F 75mm bore PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 57 | M&L for 1:4:8 type D-2 (40mm graded stone aggregate)Concrete bed to drain pipes including forming cradles against the sides of pipe after they are laid and tested for 150 mm bore of pipe etc complete all as specified and as directed. |
| 58 | Supply and lay Reinforced concrete pipes150 mm bore of pipe class NP2 laid in trenches and jointed complete with collars etc complete all as specified and directed. |
| 59 | S&F vitreous chinasingle piece EWC bowl with cistern for extended wall hung WC of Size: 380x630x770 mm, PP Soft Seat cover, Hinges, Fixing Accessories, Accessories Set, and dual Cistern fittings, P trap-180mm complete all as specified and directed. |
| 60 | S&F decorative typeWHB Vanity floor mounted made out ofcoloured PVC board of PVC/HDHMR, wash basin, side cabinet with mirror complete all specified and directed. |
| 61 | S&F Vitrous china white soap dish size 160mm x 160mm x 90mm fixed with screws and wooden/plastic cleats etc complete all as specified and directed. |
| 62 | M&L PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) in foundation concrete and mass concrete of manholes etc complete all as specified anddirected. |
| 63 | M&L PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate )in benching to man holes and finishing of exposed surfaces of concrete etc complete all as specified and as directed. |
| 64 | M&L for PCC 1:3:6 type C-1 (20mm graded stone aggregate) cast -in -situ as in copings including use and waste of formwork as required etc complete all as specified and directed. |
| 65 | M&L for precast concrete 1:2:4 type B-1 (using 20mm graded stone aggregate)in manholes covers set in CM 1:4 including necessary form work (Note :-Reinforcement will be measured and paid separately) including necessary form work etc complete all as specified and as directed. |
| 66 | S&F 30 mm thick Factory Made Solid Panel PVC Door Shutter consisting of frame made out of M.S. tubes of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC sheet 5mm thick‘C’ channel having a 5mm thick PVC sheet strip of 20mm width stuck inside with solvent cement, forming stiles, and plain colour PVC sheets for top rail, lock rail & bottom rail on either side, and as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with PVC sheet beading, and joined together with solvent cement adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s instructions and drawing. The width of stiles & rails will be in proportion to the width of the door shutter as per SSR Clause No 8B.2.1 etc complete all as specified and directed. |
| 67 | M&L for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing etc complete all as specified and directed. |
| 68 | M & L 150mm dia pipe Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed. |
| 69 | M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering etc complete all as directed. |
| 70 | M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab inclunding rubbing and polishing completeincl screed bed 15mm thick in CM 1:6 complete all as specified and directed. |
| 71 | All as per ser item No 70.00 above but in riser of steps, skirting, dado and pillar laid over cementand including 10mm thick CM 1:4 backing coat complete all as specified and directed. |
| 72 | Excavating in post holes (or similar holes) in hard/dense soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm etc complete all as specified and directed. |
| 73 | M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation filling and mass concreteetc complete all as specified and directed. |
| 74 | M&L for mild steel work tubular pipes as in stanchions incl special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 etc complete all as specified and directed. |
| 75 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified etc complete all as specified and directed. |
| 76 | S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.47 to0.50 mm thick of anycolour having tensile strength of 550 Mpa as in roof covering including ridges /cladding to wall,fixed with self tapping screws complete all as specified and directed. |
| 77 | S&L machine pressed precast concrete interlocking paver block rubber moulded, any shape and size confirming to IS-15658-2006 of 60mm thickness , M-35 grade complete all as specified and directed. |
| 78 | M&L for 30mm thick sand bedding layer for concrete paver tiles laid to true line, level watered and mechanically compacted etc complete all as directed. |
| 79 | M&L for cement concrete Type B0 1:2:4 (12.50mm aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 80 | M&L preparation of newly steel surfaces exc 10cm width or girth and applying 2 coats of synthethic enamel paint over a coat of primer etc complete all as specified and directed. |
| 81 | Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) n exc 1.5 Sqm each complete all as specified and directed. |
| 82 | S&F coloured powder coated (50 micron) aluminium sections any type for doors,windows, ventilators frames including joining cleat for fixing etc. complete all as specified and directed. |
| 83 | S&F coloured powder coated (50 micron)aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed. |
| 84 | S & F 5.50 mm thick sheet glass fixed in window shutters etc complete all as specified and directed. |
| 85 | S&F in repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main bodywith stainless steel cover,governing pivot made of brass, other parts made of mild steelheavy duty and fixed complete all as specified and directed. |
| 86 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessarystainless steel nuts and bolts complete, includingstainless steel nuts and bolts complete, includingfixing the railing with necessary accessories &stainless steel dash fasteners, stainless steel boltsetc., of required size, on the top of floor orthe side of waist slab with suitable arrangement etc complete all as specified and as directed. |
| 87 | Taking downcementplaster on Brick/concrete surface etcincluding racking out of joints hacking for keys scrubbing down with water complete all as specified and directed |
| 88 | Demolition of brick work built in cement mortar complete all as specified and directed. |
| 89 | Dismantling of Brick tiles or terracing tiles, singlelayer on roofs complete all as specified and directed. |
| 90 | Demolation of Mud in roofincluding plastering and leeping(whether full thickness removed or only a part thereofincluding plastering and leeping(whether full thickness removed oronly a part thereof complete all as specified and directed. |
| 91 | M & L for 50mm avarage thicknessPCC 1:2:4type B1 (using 20 mm graded stone aggregate as roof padding, hunching, sub base floor, even and smooth without using extra cement for further treatment complete all as specified and directed. |
| 92 | M&L for preparation of roof surface & applying evenly a tack coat of industrial bitumen primer 85/25 grade @ 1.2 Kg/SqmincludingAPP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced wih polyster non wove fabric (wt not less than 150 gms/sqm) applied on primed surface by forced application of heat and roller, joints to be touched hot and width of overlaps not be less than 150 mm complete all as specified and directed. |
| 93 | Material and labour for 40 mm thick brick tiles laid over and including 25 mm screed bead in CM 1:4 and joints grouted flush in CM 1:3 mixed with 5% of crued oil by weight of cement,complete all as specified and directed. |
| 94 | All as per ser item No 93.00 above but except brick tiles complete all as specified and directed. |
| 95 | M & L for Providing precast cement concrete louvres and jallies Type BO 1:2:4 using(12.5mm graded stone aggregate) Set in cement mortar 1:4, 30 mm thick (measured solid), includingall mouldings but excluding frame complete all as specified and directed. |
| 96 | Providing cement concrete Type B0 1:2:4 (12.50mm aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 97 | Demolition of cement concrete (unreinforced) in ground floors and paving n exc. 15cm thickness (below or above ground level) complete all as specified and directed |
| 98 | Fair cutting of brick work straight or raking cutting exc 10cm width or girthon exposed surfaces of as to fire place apertures, splayedangles, weathering, cornices,groins, etc. including rubbed finishand waste complete all as specified and directed. |
| 99 | M & L100mm thick Cementconcrete type B-1,1:2:4 (20mm gradedaggregateas floor finishing surface of concrete topping even and fair ( without using extra cement) incl form work complete all as specified and directed. |
| 100 | M&L for point wiring with 1.5 sqmm (Nominal area ) 1100 Volt PVC Insulated , FRLS unsheathed and multi strandedcopper conductor cable new PVC Concealed conduitfor one light / fan point or bell point controlled by one switch (including cutting chases and making good the distributed surfaces) and fixing new 3mm thick plastic laminated sheet top cover, sheet screws and 1.6mm thick GI sunken boxes after removing old unserviceable plastic laminated sheeet and sunken boxes included 1.5 Sqmm stranded copper conductor with green PVC Insulation earth contunity conductor connected to common earth dolly etc complete all as specified and directed.Note : The cost ofsunken boxes and bakellite sheet is included in the quoted rate. |
| 101 | One light /bell point /Fan point / Exhaust fan point controlled by one 5 amp switch one way complete all as specified and directed. |
| 102 | All as per Srl item No 100.00 above but on the same board ccomplete all as specified and directed. |
| 103 | Supply and fixing of switch piano type 6 Amps one way 230 volts AC complete all as specified and as directed. |
| 104 | Supply and Fixing of socket outlet 5 pin, 6 Amps flushtype 230 volts AC complete all as specified and as directed |
| 105 | Supply and fixing of ceiling rose 65/50 mm two to three terminals complete all as specified and directed. |
| 106 | Supply and fix of MCB 40 Amps single pole with neutral, AC 230 Volts complete all as specified and directed. |
| 107 | Supply and fix of MCBs single pole (SP) 5 to 32 Amps with 10 KA breaking capacity of \"B\" series in distribution boards complete all as specifiedand directed. |
| 108 | Supply and fixing in replacement Sheet metal enclosure for DB\"s when MCB\"s to be used double door factory made flush fixed complete with 200 Amps rated busbar 240 Volts single phase 4 ways complete all as specified and directed. |
| 109 | Material and labour of lamp holder insulated body with 9 Watt LED Bulb,back plate batten/angle type for batten fitting fixed on bakelite sheet 100mmx100mm230V AC cool day light 6500K having maximum height 1020 mm heavy duty complete all as specified and directed. |
| 110 | Supply and fix exhaust fan, PVC body single phase 230V of size 220 mm sweep with blades, frame and louvers complete all as specified and directed. |
| 111 | Supply and fixing of LED T-8 tube light fitting with single side connection LED tube rod 18/20 W, 4 Feet made of CRCA sheet steel box type including bipin holder and connection with PVC insulated twin core 23/0.0076 ywisted copper cable from ceiling rode to light fitting complete all as specified and directed. |
| 112 | Supply & fixLED Street Light Luminaire 25 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens complete all as specified and directed. |
| 113 | Supply and fixingof security lightmounting bracket made out of GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos ofpole fitting clamps made out of MS flat of size 40 x 6 mm and nutsand boltsand painting with aluminium paint, complete all as specified and directed. |
| 114 | Supply, laying in trenches or wall and testing in replacement of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core complete all as specified and directed. |
| 115 | M&L for earthing completewith galvanisedsteelearth plateelectrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade)and watering pipe 20 mm bore GI pipe(light grade ) andchamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg.50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PART 1 , with charcoal dust and saltcomplete and earth leadconnected to earthing test point (up to main switche, DBs) completeall as specified &testing on completion. |
| 116 | Supply,laying & fixing in replacement double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc ofsize 63mm outer dia and 50 mm inner dia complete allas specified and directed. |
| 117 | M&L for cutting of existing tube any size for alteration/ addition of pipes complete all as specified and directed. |
| 118 | Supply and fixing 20mm bore pipe mild steel tube medium grade galvanised with all fittings laid in trenches complete all as specified and directed. |
| 119 | Supply and fixing 20mm bore gun metal alloy screwed down high pressure with crutch with or butter fly handle screwed both ends for pipe complete all as specified and directed. |