| 1 | Demolition of un-reinforced cement concrete in ground floor and pavings not exceeding 15 cm thick (below or above ground level) and removing all the rubbish outside MoD land complete all as specified and directed |
| 2 | Dismantling of stone slabs, tiles and paver blocks of any description or thickness, laid dry or laid dry & pointed complete all as specified and as directed. |
| 3 | Dismantling and breaking up drain pipes (salt glazed ware, AC, reinforced concrete, PVC or Cast iron) set in cement mortar of size 100mm/75mmfixed over wall or in floor including clamps etc., complete all as specified and as directed. |
| 4 | M&L forpre-cast cement concrete 1:3:6, type C-1 ( using 20 mm graded crushed stone aggregates) as in solid block masonryand set in cement mortar 1:6 including demolition of existing masonary work complete all as specified and directed. |
| 5 | M&L forPCC 1:2:4, type B-1 (using 20 mm graded stone aggregates) as in coping, bed blocks, etc;including weathering, slightly rounded or chamfered angles and necessary form work including demolition of existing concrete complete all as specifiedand as directed . |
| 6 | M&L forplain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates)as in surface channels and drains including weathering, slightly rounded or chamfered angles and throating including demolition of existing concrete complete all as specifiedand as directed . |
| 7 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc all as specified and directed |
| 8 | M&L forplain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregates)75mm thick as in sub base to floor/in plinth protectionor similar items complete all as specified and as directed. |
| 9 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block, rubber moulded of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drives ways or light traffic parking etc., of required strength thickness and size/shape, made by table vibratory method using over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/laying of interlocking paver blocks in to the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 10 | M&L forprecast cement concrete designer tiles with top layer white cement & pigment in grey cement mixture, rubber moulded, 25 mm thick set,jointed and pointed with white cement & pigment to match the colour of tiles in neat cement slurry over and including screed bed 15mm thick in cement mortar 1:6 complete all as specified and directed. |
| 11 | M&L for providing pre cast man hole cover etc., in reinforced cement concrete 1:2:4, type B-1 (using 20mm nominal size crushed and graded stone aggregates) or similar type of items including demolition of existing RCC slab complete all as specifiedand as directed . |
| 12 | M&L for Reinforced Concrete pipes 250mm dia, class NP2 laid in trenches and jointed and tested including demolition of existing drain pipes complete all as specified and directed. |
| 13 | M&L for Reinforced Concrete pipes 150mm dia, class NP2 laid in trenches and jointed and tested including demolition of existing drain pipes complete all as specified and directed. |
| 14 | Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 15 | Removing excavated material n. exc. 50m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed. |
| 16 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, soil retreived from excavation complete all as specified and directed. |
| 17 | M&L for PCC (1:3:6) type C2 (using 40 mm graded stone aggregates) for concrete bed to drain pipes including packing under and haunching against side of pipes 250 mm bore after they are laid down, jointed and tested complete all as specified and directed. |
| 18 | M&L for PCC (1:3:6) type C2 (using 40 mm graded stone aggregates) for concrete bed to drain pipes including packing under and haunching against side of pipes 150 mm bore after they are laid down, jointed and tested complete all as specified and directed. |
| 19 | M&L for plain cement concerete 1:4:8 type D-2 (using 40mm graded stone aggregates) as in foundation filling and mass concerete complete all as specified and directed. |
| 20 | M&L for rendering 15mm thick cement plaster on external surfaces of brickwork with cement mortar (1:4)finished even & smoothwithout using extra cement complete all as specified and directed. |
| 21 | M&L formild steel TMT bar10 mm dia and over, cut to length, bent to shape as required including cranking bending or hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 22 | M&Lfor Cleaning of septic tank by blocking temporarily the inlet with appropritewooden plugs and bailing/pumping out water in liquid/semi liquid state from septic tank/soak pit and scraping out sludge, organic matter /inorganic matter, soft/semi solid material and removing to outside of MoD land in sealed tank container mounted over trolley/transport vehicle, self driven electrical/mechanical pump and filling into shallow pits at their own arrangement with due permission from local municipal/civil authorities at his/her own arrangement and removal of wooden plugs and channeling the water back into soakage/septic tank on the same day complete all as specified and directed. Note:- Measurement will be carried out in cubic meter capacity of sealed/closed container under which all sludge/water will be measured as capacity of tank and nothing extra will be paid on this account. Complaint Slip Book shall be provided by contractor without any extra cost.(Format of complaint slip attached) |
| 23 | M&Lfor clearing of blokage from Manholes, Grease trap, Nahani trap, WC, Floor trap, etc including washing/cleaning upto 1st manhole complete all as specified and directed.Note:-Clearing of blockage up to 15 (Fifteen) days intervalin one pit in the same place is deemed to be included in the quoted rate and after 15 (Fifteen) days of cleaning if bolcked in the same pit shall be measured separately). Measurement shall be carried out for each qtr wise. Complaint Slip Book shall be provided by contractor without any extra cost. (Format of complaint slip attached) |
| 24 | M&L for cleaning of sewage line of any diameter by roding and of any description including manholes by machines or other means of mechanical tools to clear the sludge/ blockage inside the sewage line The manholes will be flushed with water to drain out sludge etc. inside the sewage line from manholes to ease the flow of sewage including removing the sludge and re-fixing the manhole cover complete all as specified and directed. Note: Minimum two safaiwala alogwith two helpers with all tools and plant will be engaged by the contractor per day irrespective of one complaint and complaint will be attended and completed within same day. Clearing of blockage up to 15 (Fifteen) days interval the same place is deemed to be included in the quoted rate and after 15 (fifteen) days of cleaning if bolcked in the same pit shall be measured separately.Complaint Slip Book shall be provided by contractor without any extra cost. (Format of complaint slip attached) |
| 25 | S&F 75mm borePVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall with necessary clamps complete all as specified and as directed. |
| 26 | S&F 75mm borePVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floor complete all as specified and as directed. |
| 27 | S&F 110mm borePVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall with necessary clamps complete all as specified and as directed. |
| 28 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floor complete all as specified and as directed. |
| 29 | S&F PVC (SWR) floor trap of outlet dia 75mm, plain with SS gratings 125X125mm size with openable circular grating with or without hole including jointing with solvent cement including fixing to pipe properly with solvent complete all as specified and as directed. |
| 30 | S&F PVC (SWR) bends with access door for 75 mm bore pipe complete all as specified and as directed. |
| 31 | S&F PVC (SWR) bends with access doorfor 110 mm bore pipe complete all as specified and as directed. |
| 32 | S&F PVC (SWR) vent cowl 110 mm dia complete all as specified and as directed. |
| 33 | S&F PVC (SWR) vent cowl 75 mm dia complete all as specified & directed. |
| 34 | S&F grating round at center and in square size 125mmX125mm of PTMT with or without hole duly cutting of floor (Cement concrete/tile) and fixed with cement slurry complete all as specified and directed |
| 35 | S&F in repairs PTMT bib taps of any colour high pressure screwd for iron pipes complete all as specified and directed. Make Prayag, Shakti |
| 36 | M&L for rendering 15mm thick cement plaster on external surfaces of brickwork with cement mortar (1:4) and finished fair and even including taking down of existing plaster complete all as specified and directed. |
| 37 | M&Lfor applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 38 | M&Lpreparing, washing, rubbing down for applying twocoats ofacrylic emulsion paintof Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives over and including priming coat of exterior primer applied on old decorated surfacesofwalls including necessary filling of voids with wall care putty complete all as specified and as directed. |