| 1 | Excavation in trenches n. exc. 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well rammingin layers not exceeding 25 cm thick complete all as specified and directed. |
| 3 | Removing of excavated soil to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 4 | M&L Local sand dry, filling in trenches around under ground cable complete all as specified and directed. |
| 5 | M&L for providing of new sub class \"B\" Bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed. |
| 6 | Laying only oldbricks complete all as specified and directed. |
| 7 | S&F in replacement GI pipe light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc of following sizes complete all as specified & directed.(a) 40mm bore |
| 8 | All as Per Srl Item No 7 above but for 50 mm bore. |
| 9 | All as Per Srl Item No 7 above but for 80 mm bore. |
| 10 | Taking out old unserviceable LT Cable any type and size from trenches or fixed on poles or through pipes/walls/laid under roads/paths/ drains/culverts complete all as specified and directed. |
| 11 | Supply, laying, jointing and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty, conforming to IS - 7098 Part I -1988 with aluminum conductor 1100 Volts of following sizes / grade laid in ducts or on walls, in trenches encased in GI pipe fixed to walls / laid under roads / drains / paths / culverts etc complete all as specified and directed.Cable Type - 16Sqmm 4 Core |
| 12 | All as Per Srl Item No 11 above but for 35 Sqmm 3.5 core |
| 13 | All as Per Srl Item No 11 above but for 50 Sqmm 3.5 core |
| 14 | All as Per Srl Item No 11 above but for 70 Sqmm 3.5 core |
| 15 | All as Per Srl Item No 11 above but for 150 Sqmm 3.5 core |
| 16 | All as Per Srl Item No 11 above but for 185 Sqmm 3.5 core |
| 17 | All as Per Srl Item No 11 above but for 240 Sqmm 3.5 core |
| 18 | Relaying only serviceableLT UG Cable obtained from exsting of any size and discription includingnecessary cable lugs. ( All relevent items like excavation, earth work, sand cushionning, bricks etc shall be measured seperatly under respective item of Sch.) |
| 19 | S&F Heat shrinkable straight through Jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge for the following size of cables :-25 Sqmm to 50 sqmm 4 core |
| 20 | All as Per Srl Item No 19 above but for 70 sqmm to 150 sqmm, 3.5 core |
| 21 | All as Per Srl Item No 19 above but for 185 sqmm to 240 sqmm, 3.5 core |
| 22 | All as Per Srl Item No 19 above but for 300 sqmm to 400 sqmm, 3.5 core |
| 23 | Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, sloping canopy top roof, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1800 mm x 1500 mm x 500 mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive offour numbers Copper bus bar of 1000 amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland), and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron 75 x 75 x 6 mm with 600mm legs with PCC incl taking down old unserviceable LT Panel with switchgears complete all as specified and directed by the Engr-in-Charge including supply and fixing of the following accessories :- |
| 24 | INCOMING:(a) MCCB with thermal-magnetic release of capacity 630 Amp, FP, 50 Hz, 50 KA with spreader terminals - 01 Nos OUTGOING:(b) MCCB with thermal-magnetic release of capacity 320 Amp, FP, 50 Hz, 36 KA with spreader terminals - 02 Nos(c) MCCB with thermal-magnetic release of capacity 250 Amp, FP, 50 Hz, 36 KA with spreader terminals - 01 Nos (d) MCCB with thermal-magnetic release of capacity 200 Amp, FP, 50 Hz, 36 KA with spreader terminals - 01 Nos(e) MCCB with thermal-magnetic release of capacity 160 Amp, FP, 50 Hz, 25 KA with spreader terminals - 02 Nos(f) MCCB with thermal-magnetic release of capacity 100 Amp, FP, 50 Hz, 25 KA with spreader terminals - 02 Nos(g) Digital Amp Meter with selector switch -1 No(h) Digital Volt Meter with selector switch -1 No(j) LED type indication lamp RYB-1 set.(set of 03)(k) MCB SP 6 Amps, 10KA for Contrillong - 03 No\"s (l) CT\"s 600/5A - 03 No\"s |
| 25 | Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, sloping canopy top roof, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1500 mm x 1200 mm x 500 mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers Copper bus bar of 1000 amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland), and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron 75 x 75 x 6 mm with 600mm legs with PCC incl taking down old unserviceable LT Panel with switchgears complete all as specified and directed by the Engr-in-Charge including supply and fixing of the following accessories :- |
| 26 | INCOMING(a) MCCB with thermal-magnetic release of capacity 630 Amp, FP, 50 Hz, 50 KA with spreader terminals - 01 Nos OUTGOING:(b) MCCB with thermal-magnetic release of capacity 400 Amp, FP, 50 Hz, 36 KA with spreader terminals - 01 Nos(c) MCCB with thermal-magnetic release of capacity 250 Amp, FP, 50 Hz, 36 KA with spreader terminals - 02 Nos (d) MCCB with thermal-magnetic release of capacity 200 Amp, FP, 50 Hz, 36 KA with spreader terminals - 01 Nos(e) MCCB with thermal-magnetic release of capacity 100 Amp, FP, 50 Hz, 25 KA with spreader terminals - 01 Nos(f) Digital Amp Meter with selector switch -1 No(g) Digital Volt Meter with selector switch -1 No(h) LED type indication lamp RYB-1 set.(set of 03)(j) MCB SP 6 Amps, 10KA for Contrillong - 03 No\"s (k) CT\"s 600/5A - 03 No\"s |
| 27 | Supply, installing, commissioning and testing of LT feeder pillar outdoor type of dimension as per specified by manufacturer (not less than 600 x 900 x 300mm ) CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 60x60x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick CRCA steel sheet including duly painted powder coated and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel including one no incomer MCCB of cap 200 amp 36 KA with multiple outgoingprovission (Min 4 no ) suitable for up to 240 x3.5 core andAl Busbar of cap as per MCCB ratingand Multifuction meter with 3 phaseindicator lamp complete all as sepcified and directed incl taking down old unsv complete all as specified and directed. |
| 28 | Supply,installing,commissioning and testing of LT feeder pillar outdoor type of dimension as per specified by manufacturer (not less than 600 x 900 x 300mm ) CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 60x60x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick CRCA steel sheet including duly painted powder coated and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel including one no incomer MCCB of cap 160 amp 36 KA with multiple outgoingprovission (Min 4 no ) suitable for up to 240 x3.5 core andAl Busbar of cap as per MCCB ratingand Multifuction meter with 3 phaseindicator lamp complete all as sepcified and directed incl taking down old unsv complete all as specified and directed. |
| 29 | Supply,installing,commissioning and testing of LT feeder pillar outdoor type of dimension as per specified by manufacturer (not less than 600 x 900 x 300mm ) CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 50x50x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick CRCA steel sheet including duly painted powder coated and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel including one no incomer MCCB of cap 125 amp 25 KA with multiple outgoingprovission (Min 4 no ) suitable for up to 185 x3.5 core and Al Busbar of cap as per MCCB ratingand Multifuction meter with 3 phaseindicator lamp complete all as sepcified and directed incl taking down old unsv complete all as specified and directed. |
| 30 | Dismantling carefully serviceable isolating LT Panel board complete of sizes 500mm x 500 mm x 500 mm to 1400 mm x 1000 mm x 600 mm duly unscrewing/ opening front and back cover carefully and cleaning complete bus bar chamber, tightening all the nuts, bolts incomming and outgoing terninals, cleaning the all switchgear/ accessories and replacement of cable glands and replacement of stainless steel hinges of size 100mm for panel board door fixed with welding machine incl and applying one coat of synthetic enamel paint externally to panel board after scrubbing/cleaning the surface, complete testing the Panel board till satisfacation of Engr-in-Charge, complete all as specified and directed.Note :(i)Cost of necessary nuts, bolts, washers, screws and colour tape for bus bar, recharging and testing complete shall be deemed to be included in the unit quoted rate. (ii) Quantity of Stainless steel hignes as per site requirement shall be deemed to be included in the quoted rate.(iii) Cost of Aluminium/Copper bus bar, indicator lamp, selector switch, Ammeter & Voltmeter measured and paid seperately. |
| 31 | M&L in repairs Aluminium bus bar of Size 50 x 6mm with colour code & porcelain insulator suitable for 3 phase 4 wire system complete all as specified and directed. |
| 32 | M&L in repairs of LED indicator lamp (R,Y,B,G) including taking down old Unserviceable indicator lamps complete all as specified and directed. |
| 33 | M&L in repairs of Selector Switch for operating of Ampere/Voltage including taking down old Unserviceable switch Complete all as specified and directed. |
| 34 | M&L in repairs LED Digital Voltmeter, class 0.5 accuracy, 3 Phase, 415 Volts, 50 Hz, flush mounting 96mm x 96mm including taking down old unserviceable voltmeter complete all as specified and directed. |
| 35 | M&L in repairs LED Digital Ammeter, class 0.5 accuracy, 3 Phase, 415 Volts, 50 Hz, flush mounting 96mm x 96mm including taking down old unserviceable Ammeter complete all as specified and directed. |
| 36 | M&L in repairs of ofMCB, TPN, 40 Amp, C - Curve 415 Volts, 50 Hz, including taking down old Unserviceable MCB, TPN Complete all as specified and directed. |
| 37 | M&L in repairs of ofMCB, TPN, 63 Amp, C - Curve 415 Volts, 50 Hz, including taking down old Unserviceable MCB, TPN Complete all as specified and directed. |
| 38 | M&L in repairs of ofMCB, SP, 6-32 Amp, C - Curve, 240 Volts, 50 Hz, including taking down old Unserviceable MCB Complete all as specified and directed. |
| 39 | S&F in repairs of MCCB, 630 amps, 4 pole, 50 KA, with microprocessor based release with electronic Sg (LSIg) protection unit, Ics=100% of Icu with overload, short circuit & ground fault protections with inbuilt display for current metering with high accuracy of class 1 , internal battery, communication port, inbuilt USB port for software diagnosis,all accessories incl taking down existing MCCB complete all as specified and directed. |
| 40 | S&F in repairs of MCCB, 400 amps, 4 pole, 50 KA, with microprocessor based release with electronic Sg (LSIg) protection unit, Ics=100% of Icu with overload, short circuit & ground fault protections with inbuilt display for current metering with high accuracy of class 1 , internal battery, communication port, inbuilt USB port for software diagnosis,all accessories incl taking down existing MCCB complete all as specified and directed. |
| 41 | S&F in repairs of MCCB, 250 amps, 4 pole, 36 KA, with microprocessor based release with electronic Sg (LSIg) protection unit, Ics=100% of Icu with overload, short circuit & ground fault protections with inbuilt display for current metering with high accuracy of class 1, internal battery, communication port, inbuilt USB port for software diagnosis, all accessories incl taking down existing MCCB complete all as specified and directed. |
| 42 | S&F in repairs of MCCB, 160 amps, 4 pole, 36 KA, with microprocessor based release with electronic Sg (LSIg) protection unit, Ics=100% of Icu with overload, short circuit & ground fault protections with inbuilt display for current metering with high accuracy of class 1, internal battery, communication port, inbuilt USB port for software diagnosis, all accessories incl taking down existing MCCB complete all as specified and directed. |
| 43 | S&F in repairs of MCCB 4 Pole, 415 V, 200 Amps with adjustable type, breaking capacity 36 KA, Ics=100% of Icu with Copper spreader incl taking down existing MCCB complete all as specified and directed |
| 44 | S&F in repairs of MCCB 4 Pole, 415 V, 100 Amps with adjustable type, breaking capacity 25 KA, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed |
| 45 | S&F in repairs of MCCB 4 Pole, 415 V, 63 Amps with adjustable type, breaking capacity 25 KA, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed |
| 46 | Taking out carefully interlocking paver block, of any size or shape and re-laying in the same position after removing all vegetation, algae, grass etc., laid in proper slope and gradient over sand cushioning, complete all as specified and directed. Note: Sand, if required for correction of cushioning level shall be measured and paid separately. Replacement of brocken paver blocks shall be separately as \"Supply only\" |
| 47 | Supply only Machine pressed precast concrete interlocking paver block with grey cement and pigment of any shape and size as approved by GE conforming to IS-15658-2006 of 80 mm thickness, M-35 gradewith 6 mm top layer of coloured rubberised anti abrasive material complete all as specified and directed. |
| 48 | M&L for Repairing Damaged Earth Pit/Chamber including(a) M & L for PCC type C1 1:3:6(20mm graded stone aggregate) as shown in Electrical Plate No 3 of MES Schedule Part-I (b) M & L for Providing Pre-cast RCC Cover in type B1 1:2:4 (20mm graded stone aggregate) of size 350mm x350mm x 50mm, reinforced with and including 10mm dia TMT Bars @ 100mm Centre to Centre in both ways (c) M & L for Funnel and cleaning the surrounding of Earth Pit Cover and pouring Salt Water to improve the resistace and measuring and recording the same in presence of Engineer-in-Charge, complete all as specified and as directed. |
| 49 | M&LPre-cast RCC Cover type B1 1:2:4 (20mm graded stone aggregate) of size 350x350x50mm, with and including M & L for 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, including dismantling of existing RCC Cover complete all as specified and as directed. |
| 50 | M&L Cement Concrete type B1 1:2:4 (20mm graded stone aggregate) provided Around Earthing Pit having Top size 200mm x 200mm and bottom size 300mm x 300mm having 150mm in height, size of PCC Platform 900mm x 900mm x 100mm with fair finished Concrete Surfaces including necessary Formwork and Earth Work as required/ordered at Site including dismantling existing PCC, complete all as specified and as directed. |
| 51 | M&L for Cleaning and preparation of old painted surface of LT/street light pole complete and painting with one coat of aluminium paint including channels/ brackets, street lightbrackets, cross arms and making Red & white strips with synthetic enamelled paint of 30 cm height, eachalternative strip upto 1.5 mtr height and writing pole numbers with yellow synthetic enamelled paint after making circular basewith black synthetic enamelled paint and applying two coats of white wash on PCC coping complete all as specified.Note : Pole serial no will be as approved by GE/Engr-in-charge. |
| 52 | Supply and fixing in repairs SS Enclosure for Four Pole MCCB, IK 06, IP30 Protection, wall mounting for fixing of MCCB 160 - 250 Amps including taking down old unsv complete all as specified and directed. |
| 53 | M&L in replacement Earthing complete with Galvanised iron earth plate electrode 600mm x 600mm x 6mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connected with galvanised earthing strip of size 25mm x 4mm by means of nuts, bots, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessaryearth work in excavation, returning filling and removal of surplus earth upto a distance not esceeding 50 Mtr etc all as shown on electrical plate No.3 of MES Schedule Part-I complete including taking down and testing on completion complete all as specified and as directed by the Engineer-in-Charge. |
| 54 | Notes:-Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender. |