| 1 | Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof covering |
| 2 | S&F for pre-painted galvalume aluminium zinc cozting GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 3 | S&F for pre-painted galvalume aluminium zinc cozting GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 4 | Demolition of cement concrete (un-reinforced) in Ground floors and paving n.exe 15cm thickness ( below or above ground level ) including removal of rubbish out side complex (MOD land), complete all as specifiedand directed. |
| 5 | M&L 75mm thick cement concrete 1:3:6 type C2 (using 40mm graded stone agg). Plinth protection laid to a slope of 1 in 24 in alternate basis system. Each bay shall not exceed 3m in length. 12mm wide & 75mm deep joint shall be formed between the bays which shall be filled with mastic filling to full depth comprising a mixture of 1 part of hot blow bitumen 85/25 portion and two parts of heated badrapur sand (by volume) etc complete all as specified and directed. |
| 6 | M&L Cement concrete1:2:4 type B0(using 12.5mm graded crushedstone agg) asin roof leveling, finished even and fair, complete all as specified and directed |
| 7 | M&L for PCC (1:2:4) Ty B-0 using 12.5mm thick course aggregate as incills, steps, parapets,, copings, andthe like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 8 | M&L for cleaning of concrete or plastered roof surfaces and applying priming coat using bituminous primer @ 0.30 kg per sqm followed evenly a tack coat @ 1.2 Kg per sqm using 85/25 grade industrial hot blown bitumen over it laid 3 mm thick APP modified polymeric water proofing membrane minimum weight 3.6 Kg per sqm reinforced with non-woven polyester fabric (weight not less than 160 gm per sqm) rolled & bonded to substrate with side and end laps 75mm & 100mm as per manufacturer\"s instruction and applying over it a tack coat using industrial hot blown bitumen 85/25 grade @ 1.20 Kg per sqm and finally finished the top of polymeric water proofing membrane complete all as specified and directed. (Note:- Dismantling & Romoval of existing old water prrofing menbrane deemed to be included in quoted rate of this item) |
| 9 | M&L 10 mm thick plaster with CM 1:4with water proofing compound @ 3% by weight of cementfinish even and smooth surfaces using without extra cement. Water proofing compound shall be measured and paid seperately &complete all as specified and directed by Engr-in-Charge. |
| 10 | Taking down chowkhat or frames exc. 1.5 Sqm and n.exc 4 Sqm eachwith shutters (without taking off shutters from frames) complete all as specified and directed. |
| 11 | S&F for FRP doorframesthreeleggedofcrosssection90x45mmhavingsinglerebate32mmx15mm.The laminated door frame moulded with fire retardant grade unsaturated polyester resin and chopped mat. Door framelaminatedshallbe2mmthick,frameshallbe coveredwithfiberglassfromallsidesmsflatiron 25x3mm shall be provided at the bottom to steady the frame including PCC 1:2:4 Type B0 using 12.5mm graded stone aggregate as in frame, complete all as specified and directed. |
| 12 | S&F 30 mm thick FRP (fibre glass reinforced plastic) moulded flush door in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing offittings and polyurethane foam (PUF) polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameter of FRP, laminate confirming to table 3 of IS -14856 Complete all as specified by the manufacturer, complete all as specified and directed. |
| 13 | S&F 100 mm long(size) butt hinges, stainless steel AISI 304 grade with brass/bronze hinge pin, complete all as specified and directed. |
| 14 | S&F Stainless steel of AISI-304 grade barrel tower bolt 150 mm long, extruded sectioncomplete all as specified and directed. |
| 15 | S&F Extruded aluminium alloy handles, fabricated type, anodised of size 150mm size long complete all as specified and directed. |
| 16 | S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor of 140mm long complete all as specified and directed. |
| 17 | Taking down cement plaster, terrazzo dado in any thickness from brick or stonewalls etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish, vegetation etc outside complex (MOD land) complete all as specified and directed. |
| 18 | M&L Rendering 5mm thick plastering in cement mortar 1:3 as in ceiling finished even and smooth without using extra cement to match with existing surface complete all as specified and directed. |
| 19 | M & L preparing plastered new surfaces of ceiling and applying three coats of white wash on ceiling surface complete all as specified and as directed. |
| 20 | M&L Rendering 12 mm thick in cement mortar 1:6 on fair face of brick work/ concrete surfaces (either surfaces) of wall and finished even and smooth without using extra cement complete all as specified and directed. |
| 21 | M & L for preparation of new plastered or unplastered surfaces of walls and applying two coats of oil emulsion distemper, over a coat of 1.5mm thick wall care putty complete aii as specified and directed. |
| 22 | M&L Rendering 5 mm thick in cement mortar 1:4 over a layer of 10mm thick rendering in cement mortar 1:6 on fair face of brick work/ concrete surfaces of wall with water proofing admixturefinished even and smooth without using extra cementcomplete all as specified and directed. (WPC will be measured and paid separatly) |
| 23 | Supply only liquid water proofing compound complete all as specified and directed. |
| 24 | M&L for preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white wash complete all as specified and directed. |
| 25 | M&L for Complete removal of old/new existing surfaces of walls and applying two coats of wheather proof exterior emulsion paintcomplete all as specified and all as directed |
| 26 | M&L for preparation of old/new surfaces (plastered or unplastered) of walls including removing/scrapping down existing surface where ever necessary and applying two coat of oil emulsion distemperwhite or approved tinted including removing existing nails, if any and filling the disturbed / surface, holes/voids with wall care putty/POP to achieve the smooth surface complete all as specified & directed. |
| 27 | Dismantling of Cast Iron pipe/ RCC drain pipe/PVC pipeup to 150 mm bore complete all as specifiedand directed. |
| 28 | S&F PVC (SWR) pipes of 110 mm nominal outside diameter (Type B with wall thickness 3.20 to 3.80 mm) single socketed in any length with rubber ring joints including all fittings/fixtures fixed on wall or in trenches or in floor complete all as specified and directed. |
| 29 | S&F 110 mm bore PVC (SWR) bends/shoes any radius completeall as specified and directed |
| 30 | S&F in repair 110 mm pipe stackclamps out of 50mmx 5 mm flat iron includingbolts and nuts and securing ends of stays to walls or roofcomplete all as specified and directed. |
| 31 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) laid bedded and pointed in any mortar and removal of old tiles from premises complete all as specified and directed. |
| 32 | M&L Non - skid coloured ceramic glazed rectified tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, set and jointed in neat cement slurry and pointed in white or coloured cement over and including 15mm thick screed bed in CM 1:6 complete all as specified anddirected |
| 33 | M&L Coloured ceramic rectifiedtiles 300x600 x 7 to 8mm/450x600x7 to 8mm thick,as in vertical surfaces of wall suchas dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement over and including 10mm thick rendering in CM 1:4 completeall as specified. |
| 34 | S&F Virified Ceramic tiles 7to 8mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchcement over and including 15mm thick screed bed in cement mortar 1:6complete all as specified and directed. |
| 35 | All as per item No 34.00 above but as in skirting over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 36 | S&F in repair aliminium extruded section body Door closer hydrau lically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixedas directed by Engineer-in-Charge. |
| 37 | S&F in repair aliminium Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty andfixedas directed by Engineer-in-Charge. |
| 38 | Cutting grooves in brick /stone/concrete wall75mm wide and 65mm deep and shaping horizontal face ofgroove with cement mortar 1:3 complete all as specified and directed. |
| 39 | Dismantling timber scantlings 40 sq. cm and over in section, in any position |
| 40 | S&F Roof trusses (framed), trussed, purlins,rafter, columncrane gantires, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel hollow M.S. Tube or flat sections) including distance pieces, cleats gusset plateetc. (Fe-410W(GdeE-250)quality B) all as specified and directed. |
| 41 | M&L for preparing newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified and directed. |
| 42 | Excavating post holes or similar holes each not exceeding 0.5 Cum getting out in Hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface. |
| 43 | M&L PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation of manholes, filling and mass concrete etc complete all as specified and directed |
| 44 | M&L for two coat of synthetic enamel paint over a coat of red oxide including preparation of newly steel surfaces all as directed. |
| 45 | M&L anti- treatment for voids in masonry/floor using chemical emulsion one liter per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 to match the existing floors complete all as specified and directed |
| 46 | M&L for anti- treatmentalong external wall below concrete or plinth protection or masonry apron using chemical emulsion @ 2.25 liters per linear meter including drilling and plugging holes in apron complete all as specified and directed |
| 47 | Providing and fixing wooden sports flooring system comprising of 21 mm thick imported maple wood flooring boards laid over treated pine wood runners of size 70x45 mm placed at required spacing with 10/19 mm thick air cushioned rubber pads, including vapour barrier,cutting,fixing, nailing/screwing, finishing, sanding and polishing, Game line marking complete including removal of existing wooden flooring, including GST and Trasport charges all as specified and directed.Note:- (i) Make of Squash Court Flooring :- RICOCHET SURFACE LLP/PR SPORT FLOORING or any other equivalent make. (ii) Contractor will be given a warranty for 5 year for wood defects occured during that period. |
| 48 | M&L for preparation of old plastered or unplastered surfaces of ceiling and applying two of white wash complete all as specified and directed. |
| 49 | M & L for preparation of new plastered surfaces of walls and applying 1.5mm thick wall care putty complete all as specified and directed. |
| 50 | M & L for preparation of old putty surfaces of walls and applying two coats of oil emulsion distemper complete all as specified and directed. |
| 51 | M & L for preparation of old wall surfaces and applying 1.5mm thick wall care putty, including scraping of old surfaces,removal of loose material , cleaning, stopping and filling cracks, holes and undulations, finishing the surface smoothand even, complete all as specified and directed by Engr-in-charge. |
| 52 | M & L for preparation of old putty surfaces of walls and applyingand applying two coats of oil emulsion distemper complete all as specified and directed by Engr-in-charge. |
| 53 | M & L for preparation of old wall surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paintcomplete all as specified and directed. |
| 54 | M&L Non - skid coloured ceramic glazed rectified tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, set and jointed in neat cement slurry and pointed in white or coloured cement over and including 15mm thick screed bed in CM 1:6 complete all as specified anddirected |
| 55 | All as per item No 54 above but as in skirting over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 56 | S&F in repairs PVC duel action symphonic action type flushing cistern 10 ltr capacity, low level, white with inlet, ball valve and floatincluding brackets and flush pipe. |
| 57 | S&F in repair Chromium platedtubular towel rail, 20mm dia, ‘D’ type 60cm long between flanges of brass chromium platedand fixed with brass screws complete all as specified and directed . |
| 58 | S&F in repair stainless steel peg set of six complete all as specified and directed. |
| 59 | S&F in repair 15 mm dia stop cock/angle cockcast copper alloy chromium plated screwed downhigh pressure with crutch or butterfly handle,with long shank and cup (concealed type), flenchscrewed both ends for iron or for union.fixed in repair |
| 60 | S&F in repair bib taps brass cromium plated 15 mm bore size screwed down screwedfor iron pipe or for brass ferrule complete all as specified and directed. |
| 61 | S&F in repair Stainless steel grating 100mm dia of best quality as approved by GEincluding fixing in CM1:4to floor/nahani traps etc complete all as specified anddirected. |
| 62 | S&F in repair Looking mirror 600 x 450 mm beveled edge 5.5 mm thick selected quality glass, mounted on 6 mm thick commercial ply, aluminium frame around and fixed to wooden plug with CP brass screws and cup washerscomplete all as specified anddirected. |
| 63 | S&F in repair PVC connection 15 mm bore and 45cm long with washers complete all as specified and directed. |
| 64 | M&L for powder coated anodised aluminium frame for door window & ventilator with one or more rebates including joining cleat for fixing etc comlete all as specified. |
| 65 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-in-charge. |
| 66 | M&L for 20-25 mm thick Pre-polished machine cut kota single piece, single colour uniform texture stone slab of size 22\"\"x22\"\" for flooringover cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slablaid over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed |
| 67 | M&L kota stone Pre-polishedwith uniform texture of 20-25 mm thick in trader of steps (to be flushed and provided with three Nosof grooves at the end on each step), riser of steps, skirting, dado and pillarsin one single piece (size decided by Engineer-in-Charge) laid over and including cement screed 10mm thick in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing andpolishing , bevelled edge of corner etc complete all as specified and directed. |