| 1 | Surface excavation n exc 30cm deep and average 15cm deep and getting out in soft/loose soil all as specified and directed. |
| 2 | Excavation in trenches in soft/loose soil not exc. 1.5 M wide and not exc. 1.5 M deep and getting out including forming bottom to required level or slope for laying of cable, pipe and concrete bed or for manhole etc not exc.10 Sqm on plan all as specified and directed by Engineer-in-Charge. |
| 3 | Returning, filling in soft/loose soil including spreading, leveling and watering well ramming in layers n.exc. 25cm all specified and directed. |
| 4 | Removing excavated materials not exc 50 mtr and deposited where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and as directed. |
| 5 | M&L for PCC (1:4:8) type D-2, using 40mm graded stone aggregate in foundation , filing and mass concrete complete all as specified and directed. |
| 6 | M&L for 40mm thick PCC (1:2:4) type B0, using 12.5mm graded stone aggregate in damp proof course concrete complete all as specified and directed. |
| 7 | M&L for reinforced cement concrete (nominal mix) (1:2:4) type B1, using 20mm graded stone aggregate for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and other similar works complete all as specified and directed and directed. |
| 8 | M&L for reinforced cement concrete (nominal mix) (1:2:4) type B1, using 20mm graded stone aggregate as in beams, cantilevers, bressumers, lintels over 1.5 m span complete all as specified. |
| 9 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished of flat surface complete all as specified and directed. |
| 10 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams etc. for rough finished surface of concretecomplete all as specified and directed. |
| 11 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 12 | M&L for TMT MS bars of 5mm dia and upto 10mm dia as in stirrups and spacers cut to lengh bent to shape reqd incl cranking bending spirally for hooking for column and binding with MS annealed wire not less than 0.9mm dia complete all as specified and directed. |
| 13 | M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge. |
| 14 | M&L for cement concrete type C-1, (1:3:6) using 20mm graded aggregate as in bed block, post filling or filling of chowkhats including necessary form work complete all as specified and directed. |
| 15 | M&L for 75 mm thick PCC (1:3:6) type C-2 using 40 mm graded crushedstone aggregate as inplinth protection, finished fair and evencomplete all as specified and directed by Engineer-in-charge.Note :- Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. Cost of ceiling compund is included in the unit rate of this item complete all as spcified and directed. |
| 16 | M&L for rendering 10mm thick on other than fair faces of brick work or concrete surfaces in cement mortar (1:6) andfinished surface fair and smooth without using extra cement complete all as specified and as directed. |
| 17 | M&L for rendering 15mm thick in CM (1:4) on fair faces of brick or concrete surfaces, finished surface even & fair without using extra cement completeall as specified and directed. |
| 18 | M&L for rendering 5mm thick in CM (1:3) as on ceiling complete all as specified and directed. |
| 19 | S&F 15 mm dia steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed by Engineer-in-Charge. |
| 20 | M & L for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge. |
| 21 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel ridges suitable for corrugated steel sheet 0.5mm thick of red colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screwscomplete all as specified and directed. |
| 22 | S&F steel work in tubular trusses including vertical post, purlin, post, columns, special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS.1161-1998 grade St-240 complete all as specified and directed. |
| 23 | M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coatof red oxide zinc chrome primer complete all as specified anddirected by Engineer-in-Charge. |
| 24 | S&F powder coated Anodised aluminium window and ventilator shutters side hung type without sash, aluminium sections weighing 0.55 kg/ m including necessary joining cleats, glazing clips rubberpacking,anodised aluminium snap beading screws Anodise aluminium fitting such as peg stays 150 mm long (1 No ), including pag stay and hinges type B-21 100 mm long (2 No) and suitable handle (1 No) complete all as specified and directed. |
| 25 | M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed by Engineer-in-charge. |
| 26 | M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 27 | M&L for preparartion of new plastered surfaces of walls and applying two coats cement base paint over a coat of primer on walls completeall as specified and directed. |
| 28 | M&L Plain cement concrete type B1 (1:2:4), using 20 mm graded crushed stone aggregate, 50 mm thick , as as in floor and finished even and smooth using extra cement complete all as specified and directed. |
| 29 | M&L 100 mm thick Cement concrete type D-2, (1:4:8) using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 30 | M&L 75 mm thick Cement concrete type D-2, (1:4:8) using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 31 | M&L for sand filling under floors or in foundation complete all as specified and directed. |
| 32 | M&L for Machine pressed precast conctete interlocking paver block with grey cement & pigment any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed. |
| 33 | M&L for Machine pressed precast conctete interlocking paver block with grey cement & pigment any shape and size conforming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete all as specified and directed. |
| 34 | M&L for cement concrete (1:2:4) type B2 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railigs upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, sligtly rounded or chamfered angles and throating, as directed including necessary form work complete all as specified and directed. |
| 35 | M&L hard core of guage not exc. 63mm deposited spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken bricks complete all as specified and directed. |
| 36 | M&L for Point wiring complete with 1.5 sqmm single core FRLSH PVC insulatedcable with multi stranded copper condutor in and including PVC conduit 20mm dia and thickness not less than 1.5mm, ISI marked with all accessories for surface or concealed conduit as directed at site incl chase cutting for one light/fan point controlled by one one way switch including MS sheet sunken box concealed on wall duly painted inside and outside with one coat of red oxide primer and two coats of black bituminous paint with 3mm thick hylum brand bakelite sheet cover for fixing switches, sockets, regulators etc. alongwith 1.5 sqmm multi stranded FRLSH, PVC insulaedcopper cable as continuous earth connected to common earth and earth dolly including making good the disturbed surfaces complete all as specified and as directed. |
| 37 | S&F switch Piano flush type 5 amp single pole one way 230 volts all as specified & directed. |
| 38 | S&F ceiling rose 63x30 mm three terminal, polycorbonate body complete all as specified and directed. |
| 39 | S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed. |
| 40 | M&L forSub main wiring with 2 runs of 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and in existing surface / recessed PVC conduit and connecting incoming/outgoing electric connections and one run of 2.5 Sqmmsingle core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cableas earth conductorand making good disturbed surfaces complete all as specified and directed. Note : Two runs of 2.5 Sqmm cable, one run of 2.5 Sqmm earth conductor and one run of PVC conduit of 25mm dia shall be measured and paid as one unit length. |
| 41 | M&L forSub main wiring with 2 runs of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and in existing surface / recessed PVC conduit and connecting incoming/outgoing electric connections and one run of 4 Sqmmsingle core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cableas earth conductorand making good disturbed surfaces complete all as specified and directed. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth conductor and one run of PVC conduit of 25mm dia shall be measured and paid as one unit length. |
| 42 | M&L for earthing with galvanised steel earth plate elctrode 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr below GL) with the toop edge of the plate not less than 1.5 mtr below the normal group level connected to GI earth srtip of size 25x4mm thick soldered and riveted to earth plate,GI earth strip will be protected by using 50mm bore GI pipe (light grade) earth plate to equipment and watering pipe 20mm bore (light grade) and chamber/pit in PCC(1:3:6) type C1 using 20mm graded stone aggregate with precast RCC pit cover 50mm thick in (1:2:4) type B1using 20mm graded stone aggregate reinforced with 8mm dia MS TMT bar at 80mm c/c both way with lifting hook made out of 8mm dia TMT bar duly embedded in RCC cover in lieu of CI pit cover with angle iron frame including excavation and earth work and removal of surplus soil complete all as shown in electrical plase No.3 of SSR Part-I and as specified including earth plate surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers of charcoal dust, common salt complete and earth lead connected to earthing test point/main board all as specified and testing of earthing complete all as specified & directed. |
| 43 | Supply and fixing of burnt conventional fans with BLDC ceiling fans, 5 star rated by Bureau of energy with service value of not less than 8.40, (26W±10%) with or without remote, with rated speed 350 Rev per min, air delivery 220 Cum/min complete with blades, down rods, electronic regulator and accessories, 230 volt, 1200 mm sweep, suitable for single phase supply complete all as specified and directed. |
| 44 | Supply and fixing 400mm BLDC motor energy saving wall fan with remote control, double ball bearing, 1500 RPM, 5 star, 35 watt, air delivery (CMM) 76, single ph 165-285 V, ABS plastic blade complete all as specified and directed. |
| 45 | Supply, installation, testing & commissioning of electric storage water heater of 25 litre capacity, rated voltage 230 Volt, single phase, 50 Hz of rated power input-2000 Watt conforming to IS 2082 with standing loss ≤ 0.511 & ≥ 0.465 KWh/24Hr/45°C (5 Star BEE rating wef 01 Jan 2024) havingdry powder coating in water stoarge tank of ultra thick super cold rolled steel plates of high-strength, sockproof ABS body using IPX4 technology to protect electrical parts from water to avoid direct contact between cold and hot water flow, glass coated incoloy heating element for good corrosion resistance with execllent resistance to both oxidation and carbonization, panel for temperature setting between 25°C to 75°C to control energy consumption, with 3 preset controls for easy operation, energy saving high density thick PUF insulation for better heatCont/- |
| 46 | Cont/-reterition, having sacrificial magnesium anode rod with steel core to protect water tank from rust and corrosion to enhance the tank life, having safety feature like thermostate, thermal cut off, multifunction valve, shock-safe plug to prevent electric shocks by cutting off the power in case of current leakage suitable for high-rise buildings of 8 bar (0.8 Mpa) pressure including fixing & connecting accessories like mild steel anchor fastener of size 10 x 100mm with nuts and washers, drilling/making hole on wall with provision of stainless steel breaded (SS 304 Graded) connection pipe (01 Pair) in 600 mm long or as per site long enough to connected angle valve for hot & cold water circulation with nuts and washers and testing and including 15 mm bore CP angle valve of approved make and painting MES No. on geyser all as specified and and directed. |
| 47 | S&F voltage stabilizer for automatic operation, copper coil, single phase naturally air coled indoor type & designed for input variation between 170 V - 270 V with output voltage stablized at 230 V with accuracy of (+/-) 2.5% and of capacity 5.0 KVA complete all as specified and directed. |