| Sl. No. | Item Description |
| 1 | Lump Sum price worked out by the contractor for \"BUILDING & STRUCTURE\"as listed in Schedule ‘A’ Part-I representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 34 |
| 2 | Lump Sum price worked out by the contractor for \"INTERNAL WATER SUPPLY\"as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES B/F from Sl page No. 36 |
| 3 | Lump Sum price worked out by the contractor for \"INTERNAL ELECTRIFICATION\"as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 42 |
| 4 | Lump Sum price worked out by the contractor for \"ROAD, PATH & CULVERT \"as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 46 |
| 5 | Lump Sum price worked out by the contractor for \"SEWAGE DISPOSAL\" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 48 |
| 6 | Lump Sum price worked out by the contractor for \"AREA DRAINAGE\"as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 49 |
| 7 | Lump Sum price worked out by the contractor for \"COMPOUND WALL, RETAINING WALL & FENCING\"as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES B/F from Sl page No. 52 |
| 8 | Lump Sum price worked out by the contractor for \"EXTERNAL WATER SUPPLY\"as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES B/F from Sl page No. 53 |
| 9 | Lump Sum price worked out by the contractor for \"EXTERNAL ELECTRIC SUPPLY\"as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 60 |
| 10 | Lump Sum price worked out by the contractor for \"LIGHTNING PROTECTION\"as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 61 |
| 11 | Lump Sum price worked out by the contractor for \"SUMMER APPLIANCES, AIR CONDITIONING, CENTRAL AIR COOLING & PNEUMATIC LINE AIR COMPRESSOR\"as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 62 |
| 12 | Lump Sum price worked out by the contractor for \"HOT WATER SUPPLY\"as listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 64 |
| 13 | Lump Sum price worked out by the contractor for \"DG SET & EOT CRANE\"as listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 65 |
| 14 | Lump Sum price worked out by the contractor for \"SITE CLEARANCE, EXCAVATION & EARTH WORK \"as listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 67 |
| 15 | Sch \"A\" PART-XV (MISCELLANEOUS B&R AND E&M WORKS)Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under respective schedule. |
| 16 | Internal Water SupplyS & F of CP wall mixer 3 in 1 system with provision for hand shower and over head shower and including 1.50 Mtr long tele shower screwed for iron pipes or CPVC pipes or for brass ferrule and fixed complete all as specified and directed.Make - Jaquar Queen Series Cat Part No QQT - 7281 or equivalent. |
| 17 | S & F Overhead shower 150 x 150mm of square shape single flow with rubit cleaning systemABS body crome plated with gray face plate with arm having swivel joint chromium plated complete all as specified and directed.Make - Jaquar Queen SeriesCat Part No OHS - 35495 or equivalent. |
| 18 | S & F Health faucet with 1200mm long flexible mild steel tube 15mm dia with wall hook and compete all as specified and directed.Make -Jaquar Queen SeriesCat Part No ALD - 573 or equivalent. |
| 19 | S & F of 15mm bore Sink Cock with Regular Swinging Spout (Wall Mounted Model) with Wall Flange for iron pipes or CPVC pipes or for brass ferrule and fixed complete all as specified and directed.Make - Jaquar Cat Part No QQT - CHR - 7347 or equivalent |
| 20 | S & F of 15mm bore fancy type chromium plated bib taps with wall flange, screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and directed.Make - Jaquar Cat Part No FUS - CHR - 29037 or equivalent |
| 21 | S & F of 15mm bore fancy type chromium plated angular stop cock screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and directed.Make - Jaquar Cat Part No ORP - CHR - 10053 PM or equivalent |
| 22 | S & F two way bib cock with wall flange chromium plated fancy type 15 bore complete all as specified and directed.Make - Jaquar Cat Part No LYR - CHR - 38041 or equivalent |
| 23 | INTERNAL ELECTRIFICATION S & F Modular type, 3 pin 20 Amps socket with MCB SP, conforming to IS 1293: 2005 complete all as specified in IS 732 : 2019 and directed . |
| 24 | S & F Modular type, 1 module, RJ 11 Gang with shutter (Telephone Jack) complete with all accessories all as specified and directed. |
| 25 | S & F Modular type, 1 module, co-axial type TV sockets complete with all accessories all as specified and as directed . |
| 26 | S & F Modular type, 1 module, Fan Regulator all as specified and directed. |
| 27 | S & F Engagement light for indication with all accessories as specified and directed . |
| 28 | S & F Engagement light push botton with all accessories as specified and directed. |
| 29 | S & F Single pole & neutral, modular type, double door DB, 6 way, metallic distribution board conforming to IEC 61439-3, suitable for flush / surface mounting for provision of DP RCCB / RCBO / Isolator / MCB as incomer and SP MCBs as outgoing, reversible metal door witth including 100 Amps copper busbar, fully shrouded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet etc. having IK-09 & IP-43 protection complete all as specified in IS - 732 : 2019 and directed .Notes :-DP RCCB / RCBO / Isolator / MCB & SP MCBs shall be measured and paid separately. |
| 30 | Supply and fixing load line distribution board TPN vertical, 4 way double door type, fixed on wall semi flush with incoming MCCB 4 poles 100 Amps, 16 KA, busbars ,neutral link, blanking plates complete with all accessories all as specified and as directed.Note: Outgoing MCBs shall be measured and paid separately. |
| 31 | Supply and fixing load line distribution board TPN vertical, 8 way double door type, fixed on wall semi flush with incoming MCCB 4 poles 100 Amps, 16 KA, busbars ,neutral link, blanking plates complete with all accessories all as specified and as directed.Note: Outgoing MCBs shall be measured and paid separately. |
| 32 | S & FMoulded Case Circuit Breaker (MCCB) 100 Amps , 4 Pole, 16 KA, 50 Hz with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 x In), protection against short circuits (Isd adjustable from 5- 10 x Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection etc. having Ics = 100% = Icu = 16 & 25 KA as per IEC-60947-2 and suitable for 3-Phase, 415 Volt, 50 Hz electric supply complete all as specified and directed. |
| 33 | All as per item No 33 above but 80 Amps, 4 Pole, 16 KA, 50 Hz, MCCB |
| 34 | All as per item No 33 above but 250 Amps, 4 Pole, 25 KA, 50 Hz, MCCB |
| 35 | S & F MCB MCB TP, 16 to 32 Amp, breaking capacity 10 KA, 415 Volts, \"C\" curve. with sliding bottom clamp, colour coded on/off indication on dolly, bi-connect, IP-20 protected lower terminals and sliding shutters etc conforming to IS/IEC 60898-1-2002complete all as specified in IS - 732 : 2019 and as directed. |
| 36 | S & F 12 Watt LED Surface Downlight having Luminous efficacy of > 100, input voltage range 140-270 Volt, input frequency 50-60 Hz complete all as specified and directed. |
| 37 | S & F 9 Watt LED Bulb for Holder having Luminous efficacy of > 100, input voltage range 140-270 Volt, input frequency 50-60 Hz complete all as specified and directed.. |
| 38 | S & F LED Bulb Holder having Luminous efficacy of > 100, input voltage range 140-270 Volt, input frequency 50-60 Hz complete all as specified and directed. |
| 39 | S & F 100 Watt High Bay Light having Luminous efficacy of > 100, input voltage range 140-270 Volt, input frequency 50-60 Hz complete all as specified and directed. |
| 40 | S & F 9 Watt LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 Volt, input frequency 50-60 Hz complete all as specified and directed. |
| 41 | S & F 36 Watt 2 x 2 LED Panel light having Luminous efficacy of > 100, input voltage range 140-270 Volt, input frequency 50-60 Hz complete all as specified and directed. |
| 42 | S & F 20 Watt Flameproof / Weatherproof LED Tubelight capable of delivering 100 Lumen per Watt, Input Voltage - 220-240 Volt AC, input frequency 50- 60 Hz, Surge voltage protection - 4 KVA, CCT- 5500 TO 6500 K,CRI > 70%, Glass type - Borosilicate, Gasket O\" Ring endless neoprene rubber Gasket, Wire Guard Mild Steel Cable entries M20-2 Nos Material of construction - Al Die Cast, hazardious classification,Area of classification Zone-1, Zone-2, Gas Group II-A, II-B, II-C,Ingress Protection IP-66, Temperature Class T-6, Certification CIMFR & PESO including electrical connection with flexible steel conduit including providing of suitable SS gland to the fixture complete all as specified and directed. |
| 43 | S & F 35 Watt LEDProjection light having Luminous efficacy of > 100, input voltage range 140-270 Volt, input frequency 50-60 Hz complete all as specified and directed. |
| 44 | S & F 6 Watt LED, Wall mounted Study light having Luminous efficacy of > 100, input voltage range 140-270 Volt, input frequency 50-60 Hz complete all as specified and directed. |
| 45 | Supply and fix 16\" size Wall mount fan single Phase, 230 Volt with, blades, frame and louvers complete all as specified and directed. |
| 46 | Supply and fix 24\" size heavy duty Wall mount fan single Phase. 230 Volt with, blades, frame and louvers complete all as specified and directed. |
| 47 | Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type Panel of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC-61439-1 & 2 and IEC-61641, having both sides openable with hinged double doors and locking arrangement, IP-42 protection made out of 3.0mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 x 50 x 5mm, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B-1 with danger notice plate of 1.6mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3 Phase, 4 Wire system, 500 Volt grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size including fixing lugs, bolts, screws, etc. complete as specified and directed consisting offollowing :- |
| 48 | [A] BUSBAR CHAMBER[i]Copper busbar (3L + N) of rated capacity 200 Amps, covered with PVC insulated sleeves including insulator, nuts, bolts etc. with complete connection - 01 Set[B] INCOMING[i] MCCB 4 Pole, 160 Amps, 415 Volt, Ics = 100% Icu = 25 KA, 50 Hz conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 x In), adjustable short circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and Pre-alarm & Overload) - 01 No.[ii] Multifunction Meter Cl 1.0,capable for measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts - 01 No.[iii] LED phase indicators (Red, Yellow, Blue) - 01 Set |
| 49 | [C] OUTGOING[i]MCCB Triple Pole, 80 Amps, 415 Volt, Ics = 100% Icu = 16 KA, 50 Hz conforming to IEC-60947-2 havingtrip unit, adjustable overload setting (0.7 - 1 x In), adjustable short circuit setting (5 - 10 x Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and Pre-alarm & Overload) - 01 No. [ii] MCB SP, 16 Amps, 230 Volt, Ics = 100% Icu = 10 KA, 50 Hz conforming to IEC-60947-2, having trip unit, adjustable overload setting (0.7 - 1 x In), adjustable short circuit setting (5 - 10 x Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and Pre-alarm & Overload) - 16 Nos.[iii] MCB SP, 20 Amps, Ics = 100% Icu = 10 KA, 50 Hz conforming to IEC-60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 x Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and Pre-alarm & Overload)- 10 Nos.[iv] Multifunction Meter Cl 1.0, capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 27 Nos.[v] LED phase indicators (Red, Yellow, Blue) - 27 Set |
| 50 | Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type Panel of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC-61439-1 & 2 and IEC-61641, having both sides openable with hinged double doors and locking arrangement, IP-42 protection made out of 3.0mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 x 50 x 5mm, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B-1 with danger notice plate of 1.6mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3 Phase, 4 Wire system, 500 Volt grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size including fixing lugs, bolts, screws, etc. complete as specified and directed consisting offollowing :- |
| 51 | [A] BUSBAR CHAMBER[i]Copper busbar (3L + N) of rated capacity 400 Amps, covered with PVC insulated sleeves including insulator, nuts, bolts etc. with complete connection - 01 Set[B] INCOMING[i] MCCB 4 Pole, 320 Amps, 415 Volt, Ics = 100% Icu = 25 KA, 50 Hz conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 x In), adjustable short circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and Pre-alarm & Overload) - 01 No.[ii] Multifunction Meter Cl 1.0,capable for measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts - 01 No.[iii] LED phase indicators (Red, Yellow, Blue) - 01 Set |
| 52 | [C] OUTGOING[i]MCCB Triple Pole, 250 Amps, 415 Volt, Ics = 100% Icu = 16 KA, 50 Hz conforming to IEC-60947-2 havingtrip unit, adjustable overload setting (0.7 - 1 x In), adjustable short circuit setting (5 - 10 x Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and Pre-alarm & Overload) - 01 No. [ii] MCB SP, 20 Amps, 230 Volt, Ics = 100% Icu = 10 KA, 50 Hz conforming to IEC-60947-2, having trip unit, adjustable overload setting (0.7 - 1 x In), adjustable short circuit setting (5 - 10 x Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and Pre-alarm & Overload) - 06 Nos.[iii] MCB SP, 16 Amps, Ics = 100% Icu = 10 KA, 50 Hz conforming to IEC-60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 x Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and Pre-alarm & Overload)- 04 Nos.[iv] Multifunction Meter Cl 1.0, capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 11 Nos.[v] LED phase indicators (Red, Yellow, Blue) - 11 Set |
| 53 | Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type Panel of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC-61439-1 & 2 and IEC-61641, having both sides openable with hinged double doors and locking arrangement, IP-42 protection made out of 3.0mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 x 50 x 5mm, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B-1 with danger notice plate of 1.6mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3 Phase, 4 Wire system, 500 Volt grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size including fixing lugs, bolts, screws, etc. complete as specified and directed consisting offollowing :- |
| 54 | [A] BUSBAR CHAMBER[i]Copper busbar (3L + N) of rated capacity 200 Amps, covered with PVC insulated sleeves including insulator, nuts, bolts etc. with complete connection - 01 Set[B] INCOMING[i] MCCB 4 Pole, 160 Amps, 415 Volt, Ics = 100% Icu = 25 KA, 50 Hz conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 x In), adjustable short circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and Pre-alarm & Overload) - 01 No.[ii] Multifunction Meter Cl 1.0,capable for measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts - 01 No.[iii] LED phase indicators (Red, Yellow, Blue) - 01 Set |
| 55 | [C] OUTGOING[i] MCB TP, 20 Amps, 230 Volt, Ics = 100% Icu = 10 KA, 50 Hz conforming to IEC-60947-2, having trip unit, adjustable overload setting (0.7 - 1 x In), adjustable short circuit setting (5 - 10 x Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and Pre-alarm & Overload) - 04 Nos. [ii] MCB TP, 32 Amps, 230 Volt, Ics = 100% Icu = 10 KA, 50 Hz conforming to IEC-60947-2, having trip unit, adjustable overload setting (0.7 - 1 x In), adjustable short circuit setting (5 - 10 x Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and Pre-alarm & Overload) - 02 Nos.[iii] MCB TP, 16 Amps, Ics = 100% Icu = 10 KA, 50 Hz conforming to IEC-60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 x Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and Pre-alarm & Overload)- 01 No.[iv] MCB TP, 40 Amps, Ics = 100% Icu = 10 KA, 50 Hz conforming to IEC-60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 x Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and Pre-alarm & Overload)- 01 No.[v]MCB SP, 10 Amps, Ics = 100% Icu = 10 KA, 50 Hz conforming to IEC-60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 x Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and Pre-alarm & Overload)- 02 No. [vi] Multifunction Meter Cl 1.0, capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 10 Nos.[v] LED phase indicators (Red, Yellow, Blue) - 10 Set |
| 56 | S & F LED Mirror light Luminous 5 Watt having efficacy of > 100, input voltage range 140 - 270 Volt, input frequency 50 - 60 Hz complete all as specified and directed by the engineer - in - charge. |
| 57 | EXTERNAL WAER SUPPLYSupply & laying ductile iron, Pressure pipe, Class K-9, 100mm bore dia centrifugally cast (spun) with spigot & socket end ISI marked with IS-8329-2000 with cement mortar lining inside the pipes with outside zinc coating + bitumen coating suitable for push-on-joint (Rubber gasket D joining) in any lenghth complete including all jointing material and rubber gasket laid in trenches / road / pathways/pedal supports etc including making good for disturbed surfaces of road / path ways etc all as specified and directed. Note:- DI Fittings & specials will be measured & paid separatly. |
| 58 | Supply & laying ductile iron, Pressure pipe, Class K-9, 100mm bore dia centrifugally cast (spun) with spigot & socket end ISI marked with IS-8329-2000 with cement mortar lining inside the pipes with outside zinc coating + bitumen coating suitable for push-on-joint (Rubber gasket D joining) in any lenghth complete including all jointing material and rubber gasket laid in trenches / road / pathways/pedal supports etc including making good for disturbed surfaces of road / path ways etc all as specified and directed. Note:- DI Fittings & specials will be measured & paid separatly. |
| 59 | M & L Ductile iron specials of any size & any type for spigot socketed pipes such as bends (any type, radius and angle), tapers, any type (straight bend, increasing, decreasing or double socket etc) Tee pieces, single branch, “Y” junction, double branch, cross (all sockets or socket and spigot), collars, caps and plugs adopters etc of any size radius and lengh confirming IS specifications, for pipe upto 150mm bore dia complete all as specified and directed. |
| 60 | S &F Cast Iron double flanged non- rising spindle type Sluice valve having stainless steel to AISI-410 spindle & gun metal working parts, manually hand wheel operated confirming to IS:14846/2000 (PD) PN-1.6 with ISI Marked.flange ends drilled confirmingto IS :1538; suitable for 100mm bore dia pipes complete as specified and as directed. |
| 61 | S &F Cast Iron double flanged non- rising spindle type Sluice valve having stainless steel to AISI-410 spindle & gun metal working parts, manually hand wheel operated confirming to IS:14846/2000 (PD) PN-1.6 with ISI Marked.flange ends drilled confirmingto IS :1538; suitable for 80mm bore dia pipes complete as specified and as directed. |
| 62 | Construction of brick masonry valve pit of size 90cm x 90cm X 90cm (internal dimensions) with one brick thick wall in cement mortar 1:4 on 100mm thick PCC 1:4:8 type D-2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit cover 40x 40 x 6mm angle iron frame all-round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40 x 6mm embedded in PCC block 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) of size 230 x 200 x 100mm including provn of hinges welded with angle iron frame and MS cover 3mm thick sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in soft / loose soil complete all as shown on drawing and as specified. |
| 63 | All as per item No 63 above of size 90cm x 90cm x 60cm complete |
| 64 | Supply, install, testing and commissioning of manufacturer\"s factory assembled and tested electric driven centrifugal pump set of capable of delivering 570 LPM at 25 Meter head comprising of horizontal spilit casing pump multi stage CI body with impellers operating at 1440/1450 RPM coupled through a flexible coupling to a SPDP motor 1440/1450 RPM not less than 7.5 HP complete mounted on common MS base frame and foundations of the pump sets including PCC foundations, MS bolts with nuts and anti vibration pads. The work also includes the followings :-(a)Pump set capable of delivering 9.5/10 Liters per second at 25 Meters head coupled with electric driven motor of suitable size.(b) GI suction pipe medium grade not less than 65mm bore of suitable length from sump to pump setas required at site including all fitting.(C ) GI Delivery pipe medium grade not less than 80mm bore of suitable length upto 6 Meter longas required at site including all fitting.(d)CI foot valve fixed with leather washer, cast iron non returning valve of suitable size.(e)Vacuum gauge - 01 No.(f)Pressure gauge diaphragm type upto 50 Kg/Sqcm - 01 No.(g)Priming arrangement of pump set by providing GI pipe 20mm bore, medium grade, gate valve etc from existing line (Not more than 10 Meter away) with all fittings etc complete - 1 Job. |
| 65 | Supply and fix , test , commissioning of weather proof LT panel board powder coated indoor type double door shutter, made out of CRCA 3.0mm thickouter and 1.6mm thick for inner door confirming to IS-8623 with angle iron 50 x 50 x 6mm outoor, floor mounting type with closed bus bar, chamber and with aluminiumbus barwith necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supplyas per CPRI approved including provn of digital ammeter 0-100 Amps,digital voltemeter 0-500 Volts, CT\"s of suitable ratio, indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc with provision of suitable size of cable glands ,cable lugs, nut, bolts, washers etc . The bottom portion of enclosure shall be minimum 60cm above ground level of legs of angle iron completeall as specified and directed including the following :- (a) Aluminiumbus bar capacity 100 Amps for Phase- R - Y - B :- 03 Nos & Neutral-1 No (b) MCCB FP 16 KA 63 Amps - 1 No (I/C)(c) MCB TPN 10 KA 32 Amps -2Nos (For2 pump) (d) MCB SPN10 KA 32 Amps - 1 No (for pumphouse bldg) , (e) S & F DOL starter suitable for 7.5 HP pump set - 02 Nos complete with under voltage and overload protection, Single phase preventer mounted in cubical type indoor panel. including necessary wiring with PVC insulated and unsheathed copper conductor cable multistarnded of suitable size. |
| 66 | EXTERNAL ELECTRIC SUPPLY Supply and fix , test , commissioning of LT weather proof panel board powder coated outdoor type double door shutter, made out of CRCA 3.0mm thickouter and 1.6 mm thick for inner door confirming to IS-8623 with angle iron 5 0x 50 x 6 mm outoor, floor mounting type with closed bus bar , chamber and with Aluminiumbus barwith necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supplyas per CPRI approved including provn of digital ammeter 0-1000 Amps, digital voltemeter 0-500 Volts, CT\"s of suitable ratio,indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc with provision of suitable size of cable glands ,cable lugs, nut, bolts, washers etc . The bottom portion of enclosure shall be minimum 60cm above ground level of legs of angle iron completeall as specified and directed including the following :-(a) Copper bus bar capacity 750 Amps for Phase - R-Y-B :- 03 Nos & one for Neutral -01 No (b) MCCB FP 500 Amp, 35 KA - 01 No (I/C)(c) MCCB FP 250 Amp 25 KA - 02 No(d) MCCB FP 125 Amp 25 KA - 02 No(e) MCCB FP 63 Amp 16 KA - 04 Nos (f) MCCB FP 40 Amp 16 KA- 02 No (g) MCB TPN 20 Amp 10 KA - 03 Nos(h) Synchronous timer 0-24 Hrs suitable for street light control and with suitable three phase conductor - 01 Set |
| 67 | Supply and fix , test , commissioning of LT weather proof panel board powder coated outdoor type double door shutter, made out of CRCA 3.0mm thickouter and 1.6 mm thick for inner door confirming to IS-8623 with angle iron 5 0x 50 x 6 mm outoor, floor mounting type with closed bus bar , chamber and with Aluminiumbus barwith necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supplyas per CPRI approved including provn of digital ammeter 0-1000 Amps, digital voltemeter 0-500 Volts, CT\"s of suitable ratio,indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc with provision of suitable size of cable glands ,cable lugs, nut, bolts, washers etc . The bottom portion of enclosure shall be minimum 60cm above ground level of legs of angle iron completeall as specified and directed including the following :- (a) Copper bus bar capacity 300 Amps for Phase - R-Y-B :- 03 Nos & one for Neutral -1 No (b) MCCB FP 160 Amp, 25 KA - 01 No (I/C)(c) MCCB FP 125 Amp 25 KA - 01 No(d) MCCB FP 100 Amp 25 KA - 02 No(e) MCCB FP 63 Amp 16 KA - 03 Nos(f) MCCB FP 40 Amp 16 KA- 02 No (g) MCB SPN 6-32 Amp 10 KA - 05 Nos |
| 68 | Supply and fix , test , commissioning of LT weather proof panel board powder coated outdoor type double door shutter, made out of CRCA 3.0mm thickouter and 1.6 mm thick for inner door confirming to IS-8623 with angle iron 5 0x 50 x 6 mm outoor, floor mounting type with closed bus bar , chamber and with Aluminiumbus barwith necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supplyas per CPRI approved including provn of digital ammeter 0-1000 Amps, digital voltemeter 0-500 Volts, CT\"s of suitable ratio,indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc with provision of suitable size of cable glands ,cable lugs, nut, bolts, washers etc . The bottom portion of enclosure shall be minimum 60cm above ground level of legs of angle iron completeall as specified and directed including the following :-(a) Copper bus bar capacity 200 Amps for Phase-R-Y-B-3 Nos & one for neutral -1 No (b) MCCB FP 63 Amp, 25 KA - 01 No (I/C)(c) MCCB FP 40 Amp 16 KA-02 No(d) MCCB FP 32 Amp 10 KA - 02 No (e) MCB SPN 6-32 Amp 10 KA - 01 No |
| 69 | Supply and fix , test , commissioning of LT weather proof panel board powder coated outdoor type double door shutter, made out of CRCA 3.0mm thickouter and 1.6 mm thick for inner door confirming to IS-8623 with angle iron 5 0x 50 x 6 mm outoor, floor mounting type with closed bus bar , chamber and with Aluminiumbus barwith necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supplyas per CPRI approved including provn of digital ammeter 0-1000 Amps, digital voltemeter 0-500 Volts, CT\"s of suitable ratio,indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc with provision of suitable size of cable glands ,cable lugs, nut, bolts, washers etc . The bottom portion of enclosure shall be minimum 60cm above ground level of legs of angle iron completeall as specified and directed including the following :-(a) Copper bus bar capacity 500 Amps for Phase - R-Y-B :- 03 Nos & one for Neutral -1 No(b) MCCB FP 320 Amp, 36 KA - 01 No (I/C)(c) MCCB FP 100 Amp 16 KA - 02 No(d) MCCB FP 63 Amp 16 KA - 02 No(e) MCCB FP 20 Amp 10 KA - 02 Nos(f) MCB SPN 6-32 Amp 10 KA - 01 No |
| 70 | S & F 40 Watt LED street light having pressure die-cast housing with toughned glass and high power LEDs with secondary optics and IP-65 protection, including necessary electrical connections to the fitting with 3 core flexible copper conductor cable of appropriate size all as specified and directed at site. |
| 71 | Supply and fixing street light bracket made out of 32mm dia GI Pipe of length 1.50 Mtr suitable for street light bent to required angle / shape with and including necessary clamps, nuts, bolts, & washers of suitable size all as specified and directed. |
| 72 | Supply & fix Junction box of size 280 x 170 x 130mm Hinged (L) with MCB TPN 32 Amps for looping of cablefor 3 Phase and1 neutral fixed on polewith the help of MS nuts, bolts and MS clamps - 02 Nos of size 40mm x4mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box including making suitable hole in pole to take out connections to fitting if required at site. (for looping circuits of street lights) all as specified and directed. Make : Sintex/Hensel or Techno commercial equivalent as given in list of makes. Cat No GS-JB-2817 |
| 73 | Supply & fix sintex box of size 280 x 170 x 130mm Hinged (L) with 2 way connector mounted on epoxy insulators for looping of cablefor 1 Phase and1 neutral fixed on polewith the help of MS nuts, bolts and MS clamps - 02 Nos of size 40mm x4mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box including making suitable hole in pole to take out connections to fitting if required at site and provisioning of 1 Sqmm 3.0 Core flexible PVC insulated copper cable from junction box to conector of street light complete all as specified and as directed. Make : Sintex/Hensel or Techno commercial equivalent as given in list of makes. Cat No GS-JB-2817 |
| 74 | Supply & fix LED bollard light fitting 10 Watt,with IP-65 protection inverted pyramid light LED bolard complete all as specified and directed. Make Crompton Cat part No LBLA2-10-CDL or equiavalant Havells, Philips, Bajaj |
| 75 | S& F 15/16 mtr high, galvanized high mast made out heavy duty MS pipe reducing from bottom to top 15mm thick bottom plate fixing arrangement with 20mm dia foundation including necessary civil work etc complete with & including fixing arrangement suitable for 8 Lantern symmertically fitted along with their control gear and having 2 point suspension system with steel wire rope of 6mm dia and double drum winch (All as per OEM recommendations) comprising of followings :-(a) Fabrication, supply, install, test & commissioning of LT outdoor total enclosed LTpanel size 0.75 x 0.50 x 0.30 Meter approx total enclosed made out of 3.0mm thick CRCA sheet, dust & vermin proof with front opening 440 Volt, 3 phase, 4 wire having 200 Amps capacity Aluminium bus bar insulated with sleeves, Incoming MCCB TPN 63 Amps, 440 Volt, 25 KA -01 No and copper wiring with multistranded cable including timer switch electronic type 01 No with necessary MCBs SP 20 Amps 08 Nos, contractors etc, cable glands, lugs includingtwo coats ofsynthetic enamel paint over a coat of red oxide primer & making necessary pedestal 300mm height from floor level with PCC work.(b) Provision of wiring from panel to light fitting with single/multi core 4 Sqmm copper conductor cable drawn through rigid/flexible conduit with necessary fitting etc.(c) Provision of single point air termination rod and necessary fitment required for protection against lightening protection. (Earthing shall be measured& paid separately.)(d) Provision of motorised mechanical sysytem for hosting & lowering of lights carriage for repairs.(e) Provn of Aviation ligh indicator all as specified & directed. |
| 76 | M & L Cable route indicator of size 100mm dia embossed as LT round shaped 10mm thick with marking of 1.1 KV, LT welded bolted on angle iron of 25 x 25 of 60cm length grouted in PCC (1:3:6) type C-2 using block size of 150 x 150 x 150mm embedded in ground including not exceeding earth work complete all as specified and directed. |
| 77 | Cable route indicator of size 100mm dia embossed as HT round shaped 10mm thick with marking of 11 KV, LT welded bolted on angle iron of 25 x 25 of 60cm length grouted in PCC (1:3:6) type C-2 using block size of 150 x 150 x 150mm embedded in ground including not exceeding earth work complete all as specified and directed. |
| 78 | Summer ApplianceSupply & install of desert cooler electric driven (Single phase) three speed having nominal air flow capacity 4000 Cum/hrs with propeller ISI marked cooler fan motor copper winding single phase fitted with & having 3/4 Nos blade,submersible pump, Cooler body made out from 20 gauge mild steel galvanized iron sheet & water tank made out of 18 SWG having capacity 40 Ltr minimum including three louvers with wood wool pad, flexible PVC distribution pipes and 3 way junction and including Angle iron stand with suitable size completely all as specified and directed.NOTE : The quoted rate shall includes for the following :- (a) Three speed switch ISI Marked rotary type for propeller fan and one way switch pump with separate control.The switches shall have marking off-Low-medium and high.(b) Float valve on water supply connection. (c)S & F Stop Cock for suitable size before the float valve is deemed to include in the item rate. (d) PVC connection of suitable length from stop cock to float valve etc.(e)S & F for Angle Iron Stand of suitable size. |
| 79 | Supply, install and testing of refrigrators, electric driven (Single phase), not less than190/195 Liters capacity ofBEE 5 Stars rated , frost free, double door with humidity control and deoderizer, toughned glass shelves, stabilizer free operation, inverter technilogy compressor , rust resistance body, dual thermostste for refrigeretor & freezer, with cool pack, completely all as specified and directed. Make :- Voltas / LG / Samsung / Godrej |
| 80 | Supply, install and testing of refrigrators, electric driven (Single phase), not less than360 Liters capacity ofBEE 5 Stars rated , frost free, double door with humidity control and deoderizer, toughned glass shelves, stabilizer free operation, inverter technilogy compressor , rust resistance body, dual themostste for refrigeretor & freezer , with cool pack, completely all as specified and directed.(For JCO MESClub)Make :- Voltas / LG / Samsung / Godrej |
| 81 | Supply, install and testing of Deep Freezer, electric driven (Single phase), not less than200 Liters capacity ofBEE 5 Stars rated , frost free, double door with humidity control and deoderizer, toughned glass shelves, stabilizer free operation, inverter technilogy compressor ,rust resistance body, dual themostste for refrigeretor & freezer, with cool pack, completely all as specified and directed.Make :- Voltas / LG / Samsung / Godrej |
| 82 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volt to 250 Volt with output voltage stabilized at 230 Volt with accuracy of ± 2.5% and of capacity 1 KVA complete all as specified and directed. Make :- Servo or Equivalant as given in Appdx \"B\" list of makes |
| 83 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volt to 250 Volt with output voltage stabilized at 230 Volt with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed. Make :- Servo or Equivalant as given in Appdx \"B\" list of makes |
| 84 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volt to 250 Volt with output voltage stabilized at 230 Volt with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed. Make :- Servo or Equivalant as given in Appdx \"B\" list of makes |
| 85 | Supply, Install , Assembling ,Testing and Commissioning of package type air cooling units PAC 20 U Top/Down Discharge comprising of 11,700 CFM Capacity comprising of followings :-(a) 4\" inch thick imported high efficiency cellulose pads on 4 Sides.(b) Machine wityh high efficiency axial fan and single phase unit(c) Water Pump in Wet section, distribution water pipe, auto connectionwith ball valve, drain and overflow connection. (d) Engineering Plastic Body with dust filter.(e) Area Coverage : 800-1200 Sqft. (f) Single speed. |
| 86 | Supplying and fixing of canvass connection, Fire Retardant at Machine Outlet all as specified and directed. |
| 87 | Supply,Installation & testing of Galvanised Sheet fabricated duct as required at site with Connectors, GI Flanges, turning vanes with proper duct sealing etc RTV Duct Sealant complete with supports as per the specifications for following size :- |
| 88 | (a) 24 GaugeFabricated Duct |
| 89 | (b) 22 Gauge Fabricated Duct |
| 90 | Supply and Fixing Double Louvers Air Grills without damper |
| 91 | Supply, installation, testing & commissioning of Air compressor 5 Hp, 220 ltrs, 2 cylinder, 2 stage air compressor complete with all accessories incl pump & motor complete all as specified and directed. |
| 92 | Supply and fixing & testing of Oil filter reglator lubricator aluminium body carry max inlet pressure of 25 bar complete all as specified and directed. |
| 93 | Supply and fixing & testing of ButterflyValvein brass of size 20mm dia complete all as specified and directed. |
| 94 | Supply and fixing & testing of ButterflyValvein brass of size 15mm dia complete all as specified and directed. |
| 95 | Hot water SupplySupply and fix Electric Water Heater, storage type steel body with glass line insulation inner tank and heating element upto 2 KW capacity 25 Litre, BEE 5 Star rated including all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed. |
| 96 | DG SETSupply, installation, testing and commissioning complete of manufacture or OEM static silent (Sound Proof enclosre) Diesel Engine Driven Generating set capable of delivering 100 KVA water cooled, multiple cylinder. Alternator :3 phase, 415V, 0.8 PF, 50Hz. 1st fill of lube Oil @ coolant. Battery, AVM pads std, control panel with microprocessorcontroller including suitable rating of MCCB with Engine safeties and protection, residential silencer wih KRM and RECD (Retrofetted emission control device) including PCC foundaiton as recommended by OEM all around for ease of movement with antivibration pads including all features to comply with latest CPCB guidelines including AMF Panel of suitable capacity with all necessary arrangments and comprising of following :-(i) Engine (prime Mover) : Diesel Engine 1500 RPM, direct injection, multiple cylinders, four stroke confirming to ISO-9001 : 2015, water cooled naturally turbo charged capable of giving adequate BHP to drive alternator capable of delivering 100 KVA at outdoor atomospheric conditions at Jaisalmer, 24 Volts (as per manufacturer recommendations) elect battery start complete with fully wheel all standard fittings/fixtures as per manufacturer and including suitable panel with techometer lub oil temperature, starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, High water temperature, low lub oil, oil pressure over speed etc) fuel tank and first fill of lub oil and other consumables etc. |
| 97 | (ii) ALTERNATOR : Brushless AC alternator, 3 phase, 415 Volt, 4 wire rated for output of 100 KVA minimum power facgory 0.8, 1500 RPM, IP-23 Protection class enclosure, insulation class \"H\" salient pole, revolving field, single bearing automatic voltage regulator coupled through Direct/flexible coupled trhough flexible coupling with and to match the above engine.(iii) BASE FRAME : Made out of structural steel as per manufactures recommended design/specification.(iv) ACOUSTIC ENCLOSURE : Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and poer coated after seven tank process, the enclosure shall b designed for reducing the sound level to 75 DB (A) at a distance of 1 Meter at 75% load under field condition and of 70 DB at 3 Meter from Gen set when DG set is working at full load along with testing conformance, labeling certification etc as laid down in GSR No.371 (E) dt 17 May 2002.(v) Foundation/Plinth/Base : It shall be provided as per manufacturers recommendation, however inimum 0.5 Meter space should be available all around the set and height of plinth shall not be less than 0.3 Meter.(vi) Diesel storage tank of capacity adequate for storage of diesel for 12 hours operation.(vii) MISC : Tool kit, operation and maintenance catalogue, spare part list overhauling manuals guarantee card etc shall be provided as per manufacturer standard pratices and two year servicing og DG set is carried out by contractor including materialcomplete all as specified and directed. |
| 98 | EOT CRANEDesign, Fabrication,Supply, Erection, Commissioning & Testing of indoor type, medium duty class M-5, Electrically operated travelling (EOT) overhead crane as per IS:3177 & 807 (latest version), IS:2148 of 2004, capable of handling 2.0 Metric tonnes (MT), main hoist with centre to centre clear span 10 to 16 Metres, double box girder typeincluding floor operated moveablependant control by means of push buttons independent of crab trolley position, protective panel with down shop lead (DSL), trailing cable complete with all accessories / equipments duly painted with two coat of synthetic enameledpaint all as per OEM specifications and as approved by GE. The Make of crane shall be as per approved list of make given in List of make.EOT cran shall be provided with the following electrically controlled movements type :- (i) Capacity of crane: 2.0 Ton double box girder(ii) Clear span: 10 to 16 Metres each.(iii) Bay length : 80 Metres approx. (iv) Hook height : 5.0 Metres (Approx) from the floor level.(v) Longitudinal Travel speed : 10 mpm and micro LT speed 1.0 mpm(vi) Cross travel speed: 7 mpm and micro CT speed 0.7mpm(vii) Hoisting speed: 3 mpm(viii) Micro hoisting speed : 0.3 mpm(ix) Control: Pendant control(x)LT wheel track size: As per OEM recommendations(xi)CT wheel track size : As per OEM recommendations |
| 99 | NOTE : (a) Unit rate quoted shall be deemed to include provision of copper wiring of suitable size in rigid metallic conduits with accessories fixed on surfaces from main switch upto electrical control panels and provision of ISMC channel welded alongwith ISMB (gantry girder) and longitudinal travelling rail welded alongwith ISMC.(b) Clear span and bay length specified and shown on building are only indicative. The tenderer shall visit the site and ascertain exact span and bay length before designing/execution.(c) Long travel gantry girder is in the scope of building work & LT wheel andCT wheel track Sq bar has to be provided by the tenderer and cost for the same is to be included in unit rate .(d) Cap channel and rail of both sides included quoted rate it deemed to be included such provision and accessoriesbefore execution of work.(e) Dimensions, capacities/sizes of equipments/accessories mentioned on drawing are minimum to be provided. Prior approval of accepting officer shall be obtained for the detailed construction drg and electrical wiring diagram ofEOT crane and contractor shall incorporate components wherever required and the rates quoted above shall be deemed to be inclusive of such provisions and all accessories.(f) Longitudinal travel shall be limited to 1.5m away from the wall on both ends.(g) The cranes should be manufactured as per latest IS standards and safety factors. |
| 100 | EOT Crane shall comprise of the following : -(1) Major Technical Specification : Type, Capability and general requirements(a) Type : Double box type girderEOT Crane as per IS : 807 & IS : 3177. (latest version)(b) Crane Operation : Pendant control of reputed make with push button for ON, OFF, UP, DOWN, Forward, Reverse, Left, Right, Siren, Bridge Light & Emergency Stop with option for control selection.Operating voltage 110 Volts.(c) Duty Class : M-5 for Indoor Operations.(d) Lifting Capacity : 05 Metric TON(e) Span :10 to 16 Metres(f) Height of Lift :5.0 Metre(Approx)(g) LT Wheel Rail Track Size : Minimum 50 x 50 Sqmm bar(h) CT Wheel Rail track size : 50 x 50Sqmmbar (j) Bay Length :80 metre approx(k) Clearance between Rail Top to soffit Roof :As per drawing2.Maximum Speed (Metre/Min)(a)Hoisting : 3 mpm and 0.3 microspeed(b) 10 mpm and 1 mpm microspeed LT Speed(c)7 mpm and 0.7 mpm microspeed CT Speed3. Hook Approach (Maximum possible): |
| 101 | Design, Fabrication, Supply, Erection, Commissioning & Testing of indoor type, medium duty class M-5, Electrically operated travelling (EOT) overhead crane as per IS : 3177 & 807(latest version), IS:2148 of 2004, capable of handling 5.0 Metric tonnes (MT) main hoist with centre to centre clear span 12 to 16 Metres, double box girder typeincluding floor operated moveablependant control by means of push buttons independent of crab trolley position, protective panel with down shop lead (DSL), trailing cable complete with all accessories/equipments duly painted with two coat of synthetic enameledpaint all as per OEM specifications and as approved by GE. The Make of crane shall be as per approved list of make given in List of make.EOT cran shall be provided with the following electrically controlled movements type:-(i) Capacity of crane : 5.0 Ton double box girder(ii) Clear span: 12 to 16 Metres each.(iii) Bay length : 13.2 Metres approx. (iv) Hook height : 5.0 Metres (Approx) from the floor level.(v) Longitudinal Travel speed : 10 mpm and micro LT speed 1.0 mpm(vi) Cross travel speed: 7 mpm and micro CT speed 0.7mpm(vii) Hoisting speed : 3 mpm(viii) Micro hoisting speed: 0.3 mpm(ix) Control : Pendant control(x)LT wheel track size : As per OEM recommendations(xi)CT wheel track size: As per OEM recommendations |
| 102 | NOTE : (a) Unit rate quoted shall be deemed to include provision of copper wiring of suitable size in rigid metallic conduits with accessories fixed on surfaces from main switch upto electrical control panels and provision of ISMC channel welded alongwith ISMB (gantry girder) and longitudinal travelling rail welded alongwith ISMC.(b) Clear span and bay length specified and shown on building are only indicative. The tenderer shall visit the site and ascertain exact span and bay length before designing/execution.(c) Long travel gantry girder is in the scope of building work & LT wheel andCT wheel track Sqbar has to be provided by the tenderer and cost for the same is to be included in unit rate .(d) Cap channel and rail of both sides included quoted rate it deemed to be included such provision and accessoriesbefore execution of work.(e) Dimensions, capacities/sizes of equipments/accessories mentioned on drawing are minimum to be provided. Prior approval of accepting officer shall be obtained for the detailed construction drg and electrical wiring diagram ofEOT crane and contractor shall incorporate components wherever required and the rates quoted above shall be deemed to be inclusive of such provisions and all accessories.(f) Longitudinal travel shall be limited to 1.5 Meter away from the wall on both ends.(g) The cranes should be manufactured as per latest IS standards and safety factors. |
| 103 | Design, Fabrication, Supply, Erection, Commissioning & Testing of indoor type, medium duty class M-5, Electrically operated travelling (EOT) overhead crane as per IS : 3177 & 807(latest version), IS:2148 of 2004, capable of handling 12.0 Metric tonnes (MT) main hoist with centre to centre clear span 12 to 16 Metres, double box girder typeincluding floor operated moveablependant control by means of push buttons independent of crab trolley position, protective panel with down shop lead (DSL), trailing cable complete with all accessories/equipments duly painted with two coat of synthetic enameledpaint all as per OEM specifications and as approved by GE. The Make of crane shall be as per approved list of make given in List of make.EOT cran shall be provided with the following electrically controlled movements type:-(i) Capacity of crane : 12.0 Ton double box girder(ii) Clear span: 12 to 16 Metres each.(iii) Bay length : 27 Metres approx. (iv) Hook height : 5.0 Metres (Approx) from the floor level.(v) Longitudinal Travel speed : 10 mpm and micro LT speed 1.0 mpm(vi) Cross travel speed: 7 mpm and micro CT speed 0.7mpm(vii) Hoisting speed : 3 mpm(viii) Micro hoisting speed: 0.3 mpm(ix) Control : Pendant control(x)LT wheel track size : As per OEM recommendations(xi)CT wheel track size: As per OEM recommendations |
| 104 | NOTE : (a) Unit rate quoted shall be deemed to include provision of copper wiring of suitable size in rigid metallic conduits with accessories fixed on surfaces from main switch upto electrical control panels and provision of ISMC channel welded alongwith ISMB (gantry girder) and longitudinal travelling rail welded alongwith ISMC.(b) Clear span and bay length specified and shown on building are only indicative. The tenderer shall visit the site and ascertain exact span and bay length before designing/execution.(c) Long travel gantry girder is in the scope of building work & LT wheel andCT wheel track Sqbar has to be provided by the tenderer and cost for the same is to be included in unit rate .(d) Cap channel and rail of both sides included quoted rate it deemed to be included such provision and accessoriesbefore execution of work.(e) Dimensions, capacities/sizes of equipments/accessories mentioned on drawing are minimum to be provided. Prior approval of accepting officer shall be obtained for the detailed construction drg and electrical wiring diagram ofEOT crane and contractor shall incorporate components wherever required and the rates quoted above shall be deemed to be inclusive of such provisions and all accessories.(f) Longitudinal travel shall be limited to 1.5 Meter away from the wall on both ends.(g) The cranes should be manufactured as per latest IS standards and safety factors. |
| 105 | ElectricalChimneySupply , Install, Testing and Commisioning of commercial exhaust chimney electrically operated, single phase an elegant modern hood in pyramid shape push button control, baffle, filter, PDCA / FRP housing,Energy saving 2 x 2 Watt LED Lights Powerfulmotor with Top size 900mm & Suction power Airflow 1250 Cum / Hr autoclean Kitchen chimney, autuclean alarm complete all as specified and directed. |
| 106 | Supply , Install, Testing and Commisioning of commercial exhaust chimney electrically operated, single phase an elegant modern hood in pyramid shape push button control, baffle, filter, PDCA / FRP housing,Energy saving 2 x 2 Watt LED Lights Powerfulmotor with Top size 750mm & Suction power Airflow 1000 Cum / Hr autoclean Kitchen chimney, autuclean alarm complete all as specified and directed. |
| 107 | Washing PlantSupply , Install, Testing and Commisioning Air compressor 2 HP, 50 Ltrs complete with all accessories including pump, including necessary PCC foundation complete all as specified and directed. |
| 108 | Supply , Install, Testing and Commisioning Monoblock pump set suitable for 415 Volt ,3 Phase system having capacity 2 HP including necessary PCC foundation complete all as specified and directed. |
| 109 | S & F hose pipes heavy duty 30 Meter long commplete with jet nozzel complete all as specified and directed. |
| 110 | Modern laundryDesign, Supply, Installation, Testing & Commissioning of washing Machine to wash, dry for various types of solid linen including all connected civil, electrical and mechanical works with and including of following :- |
| 111 | (a) Fully computerised washing machine, washer extractor, 18 Kg Capacity per charge, electrical heater,front loading, auto timed, auto reversed, auto stop, auto temp control , auto level control, e-operated valves for auto water inlet, auto drain, variable frequency drive for variable speed, programmable logic controller (PLC), inner basket and outer body stainless steel, heavy dutyMS fabricated structure complete all as specified and directed.(b)Drying tumbler, 18 kg capacity per charge, electric heated, front loading type Microprocessor based digital controller,auto timed, auto reversed, auto stop with fully die pressed door, inner basket stainless steel, outer double walled insulated with glass wool complete all as specified and directed |
| 112 | ARBORICULTURESupply and plantation with saplings 90cm to 150cm height including excavation of suitable size pit size of pit shall not less than 45 cm dia & 60 cm deep) to accommodate the roots of plants including provn of good earth and treating with farm yard manure in the ration (4:1) fertilizers and pesticides (i.e. Bevation and neem cake BHC 10% linson dust. Thimment or phorate, manures super and vermicompost) and make up the trench area to proper levels for its growth and maintaining for one year from the certified date of completion of work complete all as specified and direceted for following tree plant :- |
| 113 | (a) Ashoka Tree Plant |
| 114 | (b) Neem Tree Plant |
| 115 | (c) Bogavila Tree Plant |
| 116 | (d) Shisham Tree Plant |
| 117 | (e) Kachnar Tree Plant |
| 118 | M & L for Grassing the area with cyndan dactylon (Calcutta grass) having rhizomes with sufficent nodes in row 5cm apart in either direction & watering, including maintenance of 02 year of the lawan till the grass forms a thick lawn free from weeds & fit for moving including sprading of good earth & composed. Note :- Grassing shall be carried out to carpeting effect i.e. on installation 80% of the ground should be vissible due to plant cover if the desired effect is not obtined than addined grass will be planted at specifid location to achive the effect. |
| 119 | Supply only PVC Water storage tank of 2000 Ltr Capacity. |
| 120 | NOTE for Sl Item No 66 to 71 :-(i) Height of plant shall be measured from top of follage (not from the isolated branch/ leaf, main stem) to 150mm from top of root. (ii) Water will not be supplied by MES for arboriculture. Contractor has to make his own arrangement for watering to plants and grass. (iii) The rates quoted by the contractor deemed to include watering, maintenance of plants / grass till Two years after certified date of completion of work.(iv). During Two years after completion of main project if any plant / grass is found dead or not of satisfactory growth, plants / grass of approved size and shape shall be provided without any extra cost to the Govt.(v). Supply and application of manure, sweet earth and pesticides, fertilizers etc up to two years after completion completion of main project are deemed to be included in the quoted unit rate.(vi)In case offailure by the contractor to maintain the plants / grass as above, the same shall be carried out by the department at his Risk and Cost..(vii) The plants shall be brought at site Six months before the date of completion of the main project work as per Work order. |
| 121 | PROVISIONAL LUMP SUM (PLS)Provide Provisional lump sum Complete all as specified and directed for following : (a) Construction of Valley Ball Ground - 1 No(b) Construction of Basket Ball Ground - 1 No (c) Construction of Foot Ball & Hockey Ground - 1 No(d) Parade Ground - 1 No |
| 122 | NOTE FOR ITEM NO 103.00 :- (1) Provisional lump sum shall be expended wholly or in parts as directed by GE. (2) The worksunder Provisional Lump Sum shall be measured and paid for at applicable rates in MES SSR 2020 Part-II subject to percentage ( + or - denomination) computed under last column of this schedule above/belowthe provisional lump sum price worked out by the MES. (3) For details refer relavent TD drawings. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail