Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down cement plaster on bricks or stone wall/ decayed surfaces of concrete from roof projectiokn or RCC Chajjas etc. including racking out joints, hacking for key, scrubbing down with water, etc. complete all as specified anddirected. |
| 2 | M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in cm 1:6 finished even and smooth (with out using extra cement) incl taking down cement plaster on brick wall etc. and racking out joints hacking for keycomplete all as specified anddirected. |
| 3 | M&L Rendering 15 mm thickonfair faces of brick/concrete surfaces in cement plaster 1:4, using water proofing compoundmix as per manufacturer detail, finished even and smooth without using extra cement, completeincl taking down cement plaster on brick wall etc. and racking out joints hacking for key , all as specified and as directed. (WPC measured and paid seperately) |
| 4 | M&L Rendering 5mm thick on concrete surfaces in CM 1:3 finished on even and smoothwithout using extra cement as in ceiling, Chajja etc.incl taking down old plaster complete all as specified anddirected. |
| 5 | M&L for sunken treatment with glass fiber reinforced modified cementitious coating system before the final coat of Latex Shield 2K (or equivalent) complete all as following :-Base Coat : Berger HS Latex plus (or equivalent)consumption base coat : 0.3 kg/m2Reinforcement : Glass fiberSecond and Third coat : Latex sheild 2K (or equivalent)Consumption top coat : 3 kg/m2System reqquirements : density : 2.00 kg/ltr;Compressive strength: 0.5N/mm2Wall penetration through the RCC slab must be sealed using Berger HS Repair (or equivalent).Intersection of base slab with wall must be provided with a 50 mm fillet using Berger HS Latex plus (or equivalent) modified mortar with a bonding coat of Berger HS Latexplus (or equivalent) modified cement slurry upto sft.All depressions, unevenness, surface honeycombng shal be repaired using Berger HS Latex plus (or equivalent) modifiled polymer mortar with a bonding coat of Berger HS latex plus (or equivalent) modified cement slurry.Including cleaning of RCC surface to remove dust, loose paricles, etc with compressed air or any other suitable technique depending on site conditions, grinding aby sharp edges, etc.Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix \"AB\" on page no. 97 of tender documents as per Sch \"A\" Note No 19 Page No 17). |
| 6 | Taking downchowkats or frames with shutters (without taking off shutter from the frames) not exceeding1.50 Sqm each completeall as specified and as directed. |
| 7 | Taking down chowkats or frameswith shutters (without taking off shutter from the frames) exceeding1.5 sqm & not exceeding4 sqm each complete all as specified and directed |
| 8 | M&L for pressed steel frames of size125mm x 60mmfor doors with one or more rebatesincludingnecessary fixing lugs, keys,hinges lock, lock strike plate etc.made out of 1.25mm thick MS sheet including one coat of red oxide zinc chrome primer including medium weight 03 Nos of MS butt hinges of size 75mm/100mm/125mm and 01 No 50mm aize of medium weight MS butt hinge complete all as specified and directed. |
| 9 | M&L for pressed steel frames of size105mm x 60mmfor doors with one or more rebatesincludingnecessary fixing lugs, keys,hinges lock, lock strike plate etc.made out of 1.25mm thick MS sheet including one coat of red oxide zinc chrome primer including medium weight 03 Nos of MS butt hinges of size 75mm/100mm/125mm and 01 No 50mm aize of medium weight MS butt hinge complete all as specified and directed. |
| 10 | M&L for PCC 1:3:6type C - 1 (using 20 mm graded crushed stone aggregate) as in back fillingof chowkats and bed blocks for hold fasts etc complete all as specified and directed. |
| 11 | M&L for Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, suppling and fixing in opening complete all as specified and directed. |
| 12 | M&L for factory made solid panel PVC door/cup board shutter 30mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails.M.S frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement or stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail.Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, suippling and fixing in the frame at site as per specification in SSR Part-I. complete all as specified and directed. |
| 13 | M&L 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides with both face is covered with deco rative face veneer with lipping/frame to match complete all as specified and directed. |
| 14 | M&L for 2nd Class hard wood 35mm thickfactory made glazed and skelton shutters open rebated and prepared to receive glass , gauze,etc (without sash bars) edges of framing plain , chamferedor rounded. Fitted with cut and mitred beads for securing wiremeshsupplied and fitted to chowkats complete all as specified and directed. |
| 15 | M&L for Steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast with locking arrangements, complete all as specified. |
| 16 | M&L for Steel window woth side hung double shutter (window consisting of two shutter out side and two shutter of similar dimention in side of Single ms frame box type hinges with steel handle of 100mm and steel peg stay, complete with glazing bars including MS guard barsand grill made out of 10mm MS square bar( grill and guard bar shall be proveded as per direction of Engr-in-Charge. |
| 17 | S&F Galvanised mild steel wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tank or galvanized wire staple completeall as specified and directed. |
| 18 | S&F sheet glass ordinary quality, 3mm thick glazed with oil putty oil putty or wooden beads, in square n exe, 0.5sqm each pane, complete all as specified and directed. |
| 19 | S&F 3mm thick figured glass, pin head type and glazing with oil putty in square n.exc 0.5 sqm each. |
| 20 | S&F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedcomplete all as specified and directed. |
| 21 | S&F 150mm Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 22 | S&F 150 mm size mild aluminium handles cast type anodised completeall as specifiedand directed |
| 23 | S&F Butt Hinges medium weight cold rolled mild steel of size 100 mm completeall as specified and directed |
| 24 | M&L for Aluminium handle cast type anodized of size 100mm complete all as specified |
| 25 | M&L for Butt hinges 100mm medium weightstainless steel complete all as specified and directed by Engr in charge |
| 26 | M&L for Aluminum anodized barrel tower bolt of extruded section and fixed complete of size 125mm long complete all as specified. |
| 27 | M&L for Aluminium handle cast type anodized of size 125mm complete all as specified |
| 28 | M&L for Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel springs, fixed in floor with over all length of cover plate 150mm |
| 29 | S&F 300mm ordinary rat tail mild steel rod pattern springs incl roller and rollerplate complete |
| 30 | Dismantling floor, hearth or wall tiling , terrazzo topping on wallsincluding cement mortar ,bedding (but no backing) removing serviceable tilesand rubbish off the premises complete all as specified and directed. |
| 31 | M&L for Home Sheild PU Roofkoat (or equivalent) is a one component liquid, solvent free, cold applied water-proofing membrane that is highly elastic and UV resistant with 10 years warranty. ASTM D 6083-97 a waterproofing and heat reflecting system having following key performace properties : 1. UV resistant, prevent yellowing and weathering2. Highly elastic upto 350% and crack bridging3. Excellent adhesion on porous and non-porous substrates4. Tensile strength > 10 N/mm2 with Geo Textile fleece5. Soler reflective Index(SRI) more then 109-111 ASTM E 1980-11 System :First coat : Providing and applying primer over the prepared surface with HS PU roofkoat Primer (or equivalent)Coverage :0.2kg/m2 (with 50 % dilution of water)Reinforcement : Geotextile 40 gsmSecond coat : Home sheildroofkoat (or equivalent)Consumption : 0.5 kg/m2Third coat : HS PU roofkoat (or equivalent)Consumption : 0.8 kg/m2 System buildup-1.5kg/sqm with geotextile of 40 gsmFor accessible roof, tiles with scred/ adhesive may be fixed thereafter.Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix \"EF\" on page no. 105 of tender documents as per Sch \"A\" Note No 19 Page No 17). |
| 32 | M&L Rendering 10mm thickonfair faces of brick/concrete surfaces in cement plaster 1:4, using water proofing compoundfinished even and smooth without using extra cement, complete,all as specified and as directed. (WPC measured and paid seperately) |
| 33 | Supply only Intergral water proofing compound liquid complete,all as specified and as directed. |
| 34 | S&F 20mm dia high density polyethylene pipes (HDPE) of pressure rating 6kgf/cm2 laid in as spout pipes to pour out rsidual water out from the treated area complete,all as specified and as directed. |
| 35 | M&L for hardcore, of broken bricks broken to gauge n exc 63mm for laying sub base of thickness 150mm complete all as specified and directed. |
| 36 | M&L Cement Concrete type D-2 1:4:8 (40MM graded crushed stone aggregate) in foundations,fillings and mass concrete in sub base complete,all as specified and as directed. |
| 37 | M&L for 25MM thick PCC (1:2:4) type B1 with 20MM graded aggregate for laying floor tiles complete,all as specified and as directed. |
| 38 | M&l for non skid coloured Ceramic Tiles 8 to 10MM thick in light shade (square/ rectangular) polished, area of each tilesexc 0.11 sqm but not exceeding 0.18 sqm in floors/ skirting etc jointed and pointed with tile adhesive anti slip [email protected]/sqm thickness upto 8 to 10MM( or equivalent) and epoxy materials for sealing of tile joint with Epoxy tile grout ( or equivalent) to the floor of tiles and bathroom complete,all as specified and as directed. |
| 39 | Demolition of cement concrete in and pavings( un reinforced) exc 15cm thickness below or above ground level, including removal of waste from defence land and dumping at a place as specified by civil authorities complete,all as specified and as directed. |
| 40 | Demolition of cement concrete in and pavings( un reinforced)n exc 15cm thickness below or above ground level, including removal of waste from defence land and dumping at a place as specified by civil authoritiescomplete,all as specified and as directed. |
| 41 | M&L for 75 mm thick PCC1:4:8 type D-2, (using 40mm graded crushed stone aggregate) as in sub base of floor complete all as specified and directed. |
| 42 | M&L for Precast designer coloured heavy duty full body paving tiles(factory made) of size 300mm*300mm*10mm top layer glazed made in any type of cement and pigment, in required patterns as approved by GE in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in Cement Mortar 1:4 complete all as specified & directed. |
| 43 | M&L for Non - skid ceramic coloured jointless tile400mm x 400mm x 7mm thick as in floors laid over and including 15 mm thick screed bed or bedding layer of cement mortar 1:4, set and jointed in neat cement slurry and pointed incoloured cement to match the colour of tiles complete, all as specified and directed. |
| 44 | M&L for Non - skid ceramic colouredjointlesstiles 400mm x 400mm x 7 mm thickon vertical surfaces such as skirting /dado etc bedded & jointed in neat cement slurry over and including 10 mm thickbacking coat of cement mortar 1:4and pointed in white or coloured cement to match the colour of tiles complete, all as specified and directed. |
| 45 | M&L for Glazed ceramic coloured tiles of size 350X 450X 7mm thick as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed. |
| 46 | M&L Non - skid coloured ceramic tiles 7 to 8mm thick joint less (square/rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors,etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15MM thick screed bed in cement mortar 1:4 and poinetd in white or coloured cement to match the colour of tiles, complete all as specified and directed |
| 47 | M&L Non - skid coloured ceramic tiles 7 to 8mm thick joint less (square/rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm on verticles surfaces such as skirting/ dado etc bedded and jointed in neat cement slurry over andincluding 10MM thick backing coat of cement mortar 1:4 and pointed in white or coloured cement to match the colour tiles, complete all as specified and directed. |
| 48 | S&F 20MM dia stainless steel drapery rods in one length per window/door as approved by GE providing with 2 nos of Bracket for holdinf curtain rod and Fiber and Fancy dome type or wall to wall fixed in repair complete all as specified & directed. |
| 49 | S&F 300MM ordinary rat tail mild steel rod pattern springs incl roller and roller plate complete all as specified & directed. |
| 50 | Supplied and fixedRotational moulded polyethlene water storage tanks three layers of 500 ltrs capacity ISI marked (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms including Dismantling of old brocken water tanks and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed. |
| 51 | Taking up or down 15 mmbore steel tubing and connections including cleaning, threadingfor prefixing or removalcomplete all as specified and directed. |
| 52 | Taking up or down 20 mm bore steel tubing and connections including cleaning, threadingfor prefixing or removalcomplete all as specified and directed. |
| 53 | S&F Steel tubing medium grade galvanised of20mm borewith all fitting and fixed complete to walls and ceiling or laid in floors. Make ISI marked |
| 54 | S&F Steel tubing medium grade galvanised of15 mm borewith all fitting and fixed complete to walls and ceiling or laid in floors. Make ISI marked |
| 55 | Refixingold galvanisedsteel tubing of20 mmboreand connections in new or old position with all fittings fixed complete to walls ,ceiling, or laid infloors etc.Complete all as specified and directed. |
| 56 | Refixing old galvanisedsteel tubing of15 mmboreand connections in new or old position with all fittings fixed complete to walls ,ceiling, or laid infloors etc.Complete all as specified and directed. |
| 57 | S & F in repairs water closet vitreous china squatting pan ‘Orrisa’ pattern size 580 X 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe, anti-syphonic pipe etc. with and including setting the trap and pan in lime concrete bedding (one lime, two sand or surkhi and 5 aggregate) minimum 150 mm thick alround and finished just below level of rim of pan to receive the floor finishes complete including making good floor complete all as specified and directed. |
| 58 | S & F in repair vitreous china wash down water closet pan (Pedestal pattern)and trap (excluding) fixing bolts,flushing cistern and flush pipe including connection to drain (or outgoing pipe)including plastic seat cover suitable for water closet pedestal pan, coloured closed pattern with flat bottom and cover and mid steel chromium plated or aluminium hinges devices with and includingbrass chromium plated standard quality jet with nozzle 1500 mm long PVC pipe etc complete all as specified and directed complete all as specified and directed. |
| 59 | S& F in repair Low level flushing cidtern PVC valveles ,syphonic action type flushing cisternwhite with inlet valve,float and handle including bracket etc as specified. |
| 60 | S& F PVC connections 15mm dia & 600mm long with PTMT nuts complete all as specified and directed. |
| 61 | S&F wall mounted bathroom glass looking mirror beveled edge of selected quality glass 5mm thick frame less with CP brass screws and cup washer etc fixed in repair complete all as specified and directed. |
| 62 | S&F stainless steel 6 pin wall hangers fixed by means of screws by drilling in to the wallscrewing into the wooden door complete all as specified and directed. |
| 63 | S&F Tubular towel rail, brass chromium plated, 20 mm dia, D type, 60 cm long between Hangs, fixed in repairs complete all as specified and directed. |
| 64 | S&F Stainless steel grating of 125mm size (square/round), male/female pattern with or without hole, fixed in nahani/floor traps with white/coloured cement, fixed in repairs, complete all as specified & directed. |
| 65 | S&F in repair 32mm dia PVC waste pipe completeall as specified & directed. |
| 66 | S&F vitreous china wash basin white flat back size 580x450mm excluding taps waste chain and plug and porcelin stopper but includin g brackets fix in repairs in RCC slab complete all as specified and directed. |
| 67 | S&F Bib taps 15mm dia cast copper alloy fancy type chromium plated, screwed down for iron pipe or for brass ferrule fixed in repair complete all as specified and directed. |
| 68 | S&F Stop cock/ angle valve15 mmcast cooper alloyof screwed down high pressure with crutch or butter fly handle , screwed with ends for iron pipe or unions fixed in repairs complete all as specified and directed. |
| 69 | S&F in repair CP brass hot & cold 15mm dia wall mixture with provision for overhead shower with 115 mm long bend pipe onupper sie connecting legs & wall flanges for mixing hot & cold water complete all as specified and directed. |
| 70 | S&F in repair for WHB brass CP mixer for mixing hot and cold water screwed down for iron pipe and fix complete all as specified and directed. |
| 71 | S&F Shower rose of C.P. swival joint of size 125mm for fixing 15mm pipeincluding fixing to steel pipe or union fixed in repairs complete all as specified and directed. |
| 72 | S&F in repairs 20mm dia gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fix in repairs complete all as specified and directed. |
| 73 | S&F Sheet Glass Self Assembly consisting of 505mm thick sheet glass self 12CM wide with CP bracket guard and railing 60 CM long complete all as specified and directed. |
| 74 | M&L for TMT bars (Fe 500),10 mm dia and over in reinforcement cut to length, bent to shape required incl bending spirally cranking, hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified. |
| 75 | M&L for TMTround bars (Fe 500), 6-8mmmm dia and over in reinforcement cut to length, bent to shape required incl bending spirally cranking, hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified. |
| 76 | M&L Precast reinforced cement concrete 1:2:4 type B-1, using 20mm graded crushed stone aggregate as incover slab set in CM 1:6,complete all as specified and directed. Note : (Reinforcement shall be measured and paid separately). |
| 77 | Demolition of cement concrete (Re-inforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 78 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for in plinth protection complete all as specified and directed. |
| 79 | M&L for 75 mm thick PCC1:3:6 type C-1, (using 20mm graded crushed stone aggregate) as in plinth protectionfinished even and smooth without using extra cement incl necessary jointscomplete all as specified and directed. |
| 80 | Dismantling cast iron or reinforced concrete drain pipes of 75/100mm bore, fixed with walls and taking out of trenches, if required all as specified and directed. |
| 81 | S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wallincluding fixing clamps complete all as specified and directed. |
| 82 | S&F PVC SWR pipe single socketed in any length to be fixed in trenches upto First Manhole of 110mm bore complete all as specified and directed. |
| 83 | S&F PVC (SWR) pipes 75 mm bore single socketed in any length with rubber ring joints fixed to wallincluding fixing clamps complete all as specified and directed. |
| 84 | S&F PVC SWR bends any radius 110mm bore with access door complete all as specified and directed. |
| 85 | S&F PVC(SWR) junction single (single \"T\") equal or unequal 110mm bore with access to door complete all as specified and directed. |
| 86 | S&F PVC (SWR) bends any radius 75mm bore complete all as specified and directed. |
| 87 | S&F Pillar taps 15 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or with out lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts screwed for iron pipe fixed in repairscomplete all as spd & directed. |
| 88 | S&F PVC(SWR) junction single (single \"T\") equal or unequal 75 mm bore with access to door ccomplete all as specified and directed. |
| 89 | M&L for PVC (SWR) Multi floor trap diameter of outlet 75mm with grating incl jointing with solvent cement. |
| 90 | S&F PVC (SWR)floor trap , plain with grating including jointing with solvent cement of 75mm outletdia all as specified |
| 91 | M&L for preparation of new wooden surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed |
| 92 | Meterial and labour for preparation of newly plasstered wall surface and applying two coat of premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay echnology, Excellent Dirt Pick up resistance of Berger Paints Ltd or equivalent of other approved make with low VOC less than 50 gram/ litre as per the LEEDS specification, Anti Algal properties in Two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instruction applied over one coat 1\"1 ratio as per manufacture\"s instruction and all coats incl primer to be applied with fully automatic airlesspray machine of paint application with a flow speed of inium 1 ltr per minute having a pressure of 300 PSI. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and directed Make : Berger Paints Weathercoat Long Life Flexo/ Nerolac Paints excel Total/ Asian Paint Apex Ultima/ JK Maximo Ultra. Notes for smart periodicals (a) Work shall be done as per MoU between tenderer and manufacturer of paints and their authorized applicator complete all as specified and directed (b) the contractor shall upload MoU between tenderer and manufacturer of paints and their authorized applicator before quoting the bids and submit the same alongwith tender & other Documents as mentioned in NIT (c) Cost of scaffolding at any height shal be included in thequoted rate. (d) Preparation of plastered or unplastered surface of removal of existing treatment by scrappigng of walls, chajjas, ceiling, fins, fascias, parapets etc shall be done by using mechanial sander with internal dust extraction system for clean environment certified by the manufacturer. After the prepartaion of surface written approval shall be obtained from GE before applying primer and further tratment/ coat. Bldg wise stage passing register shall be maintained. (e) Finishes ie cement based paint, acrylic water based exterior grade primer, premium acrylic smooth exterior emulsion etc to walls, ceiing, chajjas, fins, fascias, parapets etc shall be applied using airles spray technology and capable of operating single spray gun with a suitable hose length. the spray machine should be of are putted majufacturer with pro-guard technology and capability of traking pressure as well as paint and primer usage. (f) This equipment shall be certified by approved manufacturer. (g) The accessories for applying the finishes shall be spray in hard to reach areas ad penetration of finishes on the surface so as to achieve uniform appication and quality surface finish. Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix \"CD\" on page no. 101of tender documents as per Sch \"A\" Note No 19 Page No 17). Non uploading of MOU by the bidder shall lead to rejection of bid during technical evaluation. |
| 93 | Material and labour for complete removal of existing treatment including fascias, cornices etc by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\"/9\" to make the surface free from dust, loose paint and loose plaster to be completely removed by skilled labour and repair of external wall/ chajjas to be done with repair mortar to get even surface including preparation of old surface of wall/ ceiling by filling cracks by Berger Bison Putty/ crack fill paste of Berger Paints or equivalent make and make good smoothen surfae by sand paper and applying two coats of premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance of Berger Paints Ltd or equivalent of other approved make with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water based exterior grade primer @ 0.9 ltr (undiluted)/10 sqm mtrs diluted with water in 1:1 ratio as per manufacture\"s instruction and all coats incl primer to be applied with fuly automatic airless spray machine of paint appliaction with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI all as specified and directed.Allow 6-8 hrs to dry the surrface in subsequent coats of paint and including necessary scaffolding at any height complete all as specified and directedMake : Berger Paints Weathercoat Long Life Flexo/ Nerolac Paints excel Total/ Asian Paint Apex Ultima/ JK Maximo Ultra Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix \"CD\" on page no. 101 of tender documents as per Sch \"A\" Note No 19 Page No 17). |
| 94 | M&L for preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed |
| 95 | M&L for complete removal of existing treatment from internal wall/ceiling surfaces including preparation of old surfaces ans applying one coat of oil bound distemper over wall care putty complete all as specified and directed |
| 96 | M&L for preparation of new plaster surfaces of walls and applying two coats of oil emulsion distemper over a coat of wall care puttyall as specified and directed. |
| 97 | Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified & directed. |
| 98 | M&L for brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6, complete all as specified & directed. |
| 99 | M&L for brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6 but except brick i.e. using serviceable bricks obtained from Srl item No. 9 here-in-before, complete all as specified & directed. |
| 100 | M&L for capilary rise treatment of walls as following :-Base coat: Berger HS Latex plus (or equivalent)Consumption base coat: 0.3 kg/m2Second and Third coat: Latex sheild 2K (or equivalent)Consumption top coat: 3 kg/m2System requirements: density: 2.00 kg/ltrCompressive strength: 0.5 N/mm2 Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix \"GH\" on page no. 109of tender documents as per Sch \"A\" Note No 19 Page No 17). |
| 101 | M&L for providing cement concrete type B-0 1:2:49(using 12.5MM grade stone aggregate) in roof padding, roof kerbs or mud stops, rounded or chamfered on edges |
| 102 | Complete removal of existing roof treatment or roof tiles and removing from site to a place outside defence land as specified by civil authorities and clean the surface of roof with water and remove the dust complete all as specified. |
| 103 | M&L for higly elastic, UV-resitant membrane one component, water based, liquid, solvent- free coating for adhesion on various surfaces including porous and non porous substrates with ability to bridge cracks, cold applied, water proofing membrane that is highly elastic and UV resitant with 10 years warranty. ASTM-D 6083-97a. Waterproofing and heat reflecting system having following key performance properties. 1 UV resistant, prevent yellowing and weathering 2. Higly Elastic upto 350% and crack bridging 3. Excellent adhension on porous and non porous substrates 4. Tensile Strength >10N/mm2 with Geo Textile fleece 5. Solar Reflective Index (SRI) more then 109-111 ASTM E1980-11 SystemFirst coat providing and applying OEM Perscribed compatible primer over ther prepared surface for adhesion and bridging cracks. Coverage : 0.2Kg/m2 (with 50% dilution of water Reinforcement: Geotextile 40 gsmSecond coat highly elastic UV-Resstant membrane one component, water-based, liquid, and solvent-Free coating for adhesion on various surface, including porous and non- porous substrates, with ability to bridge craks. Consumption : 0.5kg/m2 Third coat highly elastic,UV -resistant membrane one-component, water based, liquid and solvent-free coating for adhesion on various surface, including porous and non -porous substrates, with ability to bridge cracks. consumption : 0.8Kg/m2system buildup 1.5Kg/Sqm with geotextile of 40gsm for accessible roof, tiles with screed/ adhesive may be fixed thereafter. |
| 104 | S&F for 5MM thick transparent acrylc Perspex glass sheet with smooth edges and corners fixing to aluminium frame/iron frame/ wooden frame etc with self tapping screws/ bolts/ mild steel wire not less than 0.9mm dia etc complete all as specified and directed |
| 105 | Takingout carefully copper/aluminium point wiring,Light,fan,socket or powercomplete with all fitting, fixtures such as switch socket out let, ceiling rose ,holder ,regulator,DBs etc including making good the disturbed surface of wall/floors complete |
| 106 | Taking down existing unserviceable submain wiring any size and making good the disturbed surface all as specified and as directed. |
| 107 | M&L for point wiring for one light point/fan point/bell point controlled by one way switch with 1.5 Sqmm FRLS PVC insulated, unsheathed, single core, multi-stranded copper conductor cable, 1100 Volts grade, drawn through and including concealed rigid PVC conduit (medium grade) of suitable dia, with 1.5 Sqmm FRLS copper conductor cable as earth continuity wire connected to common earth dolly, terminated in and including modular type pressed steel sunken box (wall thickness not less than 1.22 mm up to 200×300 mm and 1.63 mm for larger sizes) with 3mm thick modular polycarbonate cover plate suitable for mounting modular switches/sockets/regulators etc., including cutting chases, making good disturbed surfaces with cement mortar (1:3), finishing to match existing surface and testing on completion, all as specified and directed. |
| 108 | All as per item no-107 above but One light point controlled by two 2-way switches, with cables 1.5 sq. mm size |
| 109 | All as per item no-107 above but for one Exhaust fan point controled by one piano switch all as directed. |
| 110 | All as per ser item No107 hereinbefore but for one 3 pin socket outlet 5 Amp Same. |
| 111 | All as per ser item No 107 hereinbefore but for one 3 pin socket outlet 5 Amp independent. |
| 112 | All as per Item no 107 here-in-before but for one15 Amp 3pin switch socket outlet, independent with 4 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 2.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed. |
| 113 | S&F one way 6 Amps, 230 Volts modular switch, ISI marked, single module type, complete with necessary connections and testing on completion, all as specified and directed. |
| 114 | S&F one way 16 Amps, 230 Volts modular switch, ISI marked, single module type, complete with necessary connections and testing on completion, all as specified and directed. |
| 115 | S&F 5 Amps, 230 Volts, 3-pin modular socket outlet, ISI marked, 2 module type, complete with necessary connections and testing on completion, all as specified and directed. |
| 116 | S&F 5A/16A, 230 Volts, 5-pin modular socket outlet, ISI marked, 2 module type, complete with necessary connections and testing on completion, all as specified and directed. |
| 117 | S&F 2-way modular switch, 6A/230V, ISI-marked, suitable for two-point control of light/fan, complete with necessary connections, testing and commissioning as required.” |
| 118 | Supply and fixof Ceiling rose surface bakelite three terminals 240 volts complete, all as specified & directed. |
| 119 | Supply and fix of Lamp holder PVC case body of Bakelite with back plate suitable for batten fittings , all as specified. |
| 120 | Supply and fix in repair LED lamp,6500K,900lm in white colour of 9 Watt base cap B-22 with poly carbonate difusser and aluminium heat sink ,complete all as specified & directed. |
| 121 | S&F in replacementLED tube light fitting 20/22 watts, 220 volts AC ,6500K Colour temp, length 4 ft appx, with aluminium housing & integrated electronic driver complete with driver with polycarbonate diffuser & thd< 10% including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose complete all as specified. |
| 122 | S&F integrated type rechargeable LED batten light fitting 20 Watt, 230 Volts AC, energy efficient, sleek linear design with extruded aluminium housing and polycarbonate diffuser, inbuilt rechargeable lithium battery providing automatic operation during power failure with minimum backup of 2 to 3 hours, complete with inbuilt electronic driver and all accessories including connection from ceiling rose with flexible copper conductor cable and fixing on wall/ceiling with suitable clamps and screws all as specified and directed. |
| 123 | S&F bulk head light fitting LED 10 Watt, 230 Volts, IP65 weather proof, energy efficient, die-cast aluminium body with polycarbonate diffuser, complete with necessary terminal block, gasket, hardware and connection with flexible copper conductor cable including fixing on wall/ceiling with suitable screws and rawl plugs all as specified and directed. |
| 124 | Supply and fix IP 66 Integral LED security light luminaire 35 W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & heat resistanttoughned glass ,efficacy 110 lumens/watt, external 10KV,440 volt SPD and inbuilt 4KV , IP 67 potted isolated driver with operating range 902V to 340V AC .CCT 5700K,LED life -1 lakh burning hours,fixture should withstand 320 volt upto 48 hrs , Auto cut off >320 volts & restart,440 Volt sustainupto 8 hrs,NABL Acreddited LM79 report including GI pipe 40mm ,medium grade ,1.7mtr long mounting bracket and providing fixing clamps ,bolts,nuts of suitable sizecomplete all as specified and as directed. |
| 125 | Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm and one single core PVC insulated (unsheathed) solid copper conductor FRLS cable of size 6 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement moter 1:3 and making good disturbed surface complete all as specified and as directed. (from TPN to SPN) |
| 126 | Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm and one single core PVC insulated (unsheathed) solid copper conductor FRLS cable of size 1.5 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement moter 1:3 and making good disturbed surface complete all as specified and as directed. (For security light) |
| 127 | M&L for taking down unsv ceiling fan/Exhaust fan of any sweep carefully, including disconnecting electrical connections, removing downrod/canopy as required, and depositing the retrieved fan in E/M store, all as specified and directed |
| 128 | S&F energy-efficient ceiling fan, 1200 mm sweep, complete with blades, downrod, electronic fan regulator and all standard accessories, 230 V single-phase operation, BLDC (Brushless Direct Current) motor type, 5-Star BEE rated, delivering minimum air flow of 210 CFM and service value not less than 6.0, including electrical connections, testing and commissioning, all as specified and directed |
| 129 | S&F exhaust fan steal body of 450 mm sweep, 230 V, complete with blades, frame, louver/shutter and all standard accessories, including cutting of wall to required size, fixing the fan in position with proper mounting arrangement, making connections from ceiling rose , and making good the disturbed wall surface with cement mortar/finishing to match the existing surface, testing and commissioning, all as specified and directed. |
| 130 | Taking down distribution boards/wooden board ,switch fuse units,steel enclosures for MCB of any type and removing from site all as specified and as directed by the Engineer in charge. |
| 131 | Supply, laying or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of size 35 Sqmm, 4 core including making electrical connection with thimbles complete all as specified. |
| 132 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables or other items and getting out soil in soft/loose soil complete all as specifed. |
| 133 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified. |
| 134 | Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil complete all as specified. |
| 135 | M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable all as specified. Note: Punned thickness of sand shall be measured & paid. |
| 136 | M&L for well burnt sub class \"B\" bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick complete all as specified and directed. |
| 137 | Supplying and laying GI tubing light grade of size 40 mm bore for cable protection complete all as specified. |
| 138 | S&F TPN vertical type distribution board, 4-way, double door, 415 Volts, IP43 protection, powder-coated sheet-steel enclosure, factory-wired for three phase and neutral, complete with 200 Amps rated busbar, designed for flush mounting (fixed into wall), including cutting of wall, embedding the DB in position, reinstating the surface with cement mortar, and making necessary connections with copper conductor cable, all as specified and directed. |
| 139 | Supply and fix of Thermal magnetic release MCCB 4 pole 415 volt rapturing capacity 16 KA of size 100 amp complete all as specified. |
| 140 | S&F SPN distribution board, 8-way, double door, 240 Volts, IP43 protection, powder-coated sheet-steel enclosure, factory wired for single phase and neutral, complete with 200 Amps rated busbar, suitable for incoming MCB/Isolator up to 63 Amps and outgoing MCBs as required, designed for flush mounting (fixed into wall), including cutting of wall, embedding the DB, reinstating the wall surface with cement mortar, and making necessary connections with copper conductor cable, all as specified and directed |
| 141 | S&F SPN distribution board, 4-way, double door, 240 Volts, IP43 protection, powder-coated sheet-steel enclosure, factory wired for single phase and neutral, complete with 200 Amps rated busbar, suitable for incoming MCB/Isolator up to 63 Amps and outgoing MCBs as required, designed for flush mounting (fixed into wall), including cutting of wall, embedding the DB, reinstating the wall surface with cement mortar, and making necessary connections with copper conductor cable, all as specified and directed. |
| 142 | S&FMCB SP of rating 6 to 32 Amps, 240 Volts, 10 kA breaking capacity, C-curve, ISI marked, conforming to IS/IEC 60898, fixed in DB with necessary connections, testing on completion, all as specified and directed. |
| 143 | S&F SPN MCB 40-63 Amps, 240 Volts, 10 kA breaking capacity, C-curve, ISI marked, conforming to IS/IEC 60898, fixed inDB with necessary connections and testing on completion, all as specified and directed. |
| 144 | Earthing complete with galvanized mild steel earth plate electrode size 600x600x6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 part-I, connected to test point complete, all as specified and testing on completion. (For TPN DB) completion, all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail