| Sl. No. | Item Description |
| 1 | Taking down Chowkats or frames with shutters (Without taking off shutters from the frames)not exceeding 1.5 Sqm each including iron mongries, hold fast etc andincluding making good disturbed portions of walls in CM 1:4 complete all as specified and directed. |
| 2 | Taking down Chowkats or frames with shutters (Without taking off shutters from the frames)exceeding 1.5 sqm but not exceeding 4.0 Sqm each including iron mongries, hold fast etc and including making good disturbed portions of walls in Cm 1:4 complete all as specified and directed. |
| 3 | Taking down shutters of any description n exceeding 1Sqm each complete all as specified and directed. |
| 4 | Taking down shutters of any description exceeding 1Sqm but not exceeding 2 Sqm each complete all as specified and directed. |
| 5 | S & F Second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 6 | S&F 125mmx60mmx1.25mm thick pressed steel, frames for door with one or more rebates including filling and compaction with PCC (1:3:6) Type C-1 using 20 mm graded stone aggregate, necessary fixing lugs, hinges, lock strike plate, etc, complete including wooden texture finished paint on the frame surface complete all as specified and directed |
| 7 | S&F 105mmx60mmx1.25mm thick pressed steel, frames for door with one or more rebates including filling and compaction with PCC (1:3:6) Type C-1 using 20 mm graded stone aggregate, necessary fixing lugs, hinges, lock strike plate, etc, including wooden texture finished paint on the frame surface complete all as specified and directed. |
| 8 | S & F 35 mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including teakwood lipping 6mm thick fixed with nails complete all as specified and directed. |
| 9 | M & L for 35mm thick plain framed glazed and skeleton shutter open rebated& prepared to receive glass, gauge etc, without sash bar edges of framingplain chamfered or rounded fitted with cut and mitered beads for securing glass etc, of 2nd class hard wood , members of shutters as specified in SSR Part - ISection 8 clause 8.24 (a) fitted to chowkats complete all as specified and directed. |
| 10 | S & F Solid Prelam PVC Door Frame of size 50mm x 47mm made out of 5mm thick single side prelam PVC sheet used instead of Plain colour PVC sheet reinforced with MS tube, suppling & fixing in opening as per specification & drawing complete all as specifed and directed. |
| 11 | S&F 30 mm thick factory made one side Prelam PVC sheet other side decorative (door shutter) used instead of Plain colour PVC sheet. Stile and rails feathered at edges and on other side 10mm 90 degree bent edge consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C\" channel heaving aPanelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site complete all as per specification & drawing. |
| 12 | S&F steel windows with pressed steel frame (size 95 x 45 x 1.25 mm ) side hung shutter including box type hinges with steel handle and steel peg stay with glazed openable shutter with glazing bar ( open out side ) and wire gauged openable shutter without glazing bar ( open inside ) dovetailed or welded complete all as specified and all as per DRG No TD/088 dt 07 Jan 2002 Note :- (i) Two shutters ie wire guaged and glazed shall be fixed in one composite frame and both shutter shall be measured as one unit(ii) Rate for filling PCC in frame deemed to be included in quoted rates(iii) MS Grill, glass and wire mesh shall be measured and paid seperatly under relevant item of schedule |
| 13 | S&F in repairs steel ventilator with top hang shutters with pressed steel frames including hinges, steel peg stay in repairs complete all as specifed and directed. |
| 14 | S&F for 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed. |
| 15 | S&F for 150mm longaluminium anodized barrel tower bolts of extruded section complete all as specified and directed. |
| 16 | S&F for 125 mm long D shaped Aluminium alloy handles, cast type, anodised complete all as specified and directed. |
| 17 | S&F for 100 mm long medium weight, cold rolled stainless steel Butt hinges with steel screws complete all as specified and directed. |
| 18 | S & F Galvanized mild steel wire cloth, 0.56 mm dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and directed. |
| 19 | S & F in repair 100 mm long medium weight, cold rolled mild steel Butt hinges with screws complete all as specified and directed. |
| 20 | S & F in repair200mm long Aluminium, anodised, barrel tower bolts of extruded section complete all specified and as directed. |
| 21 | S&F in repair 250mm long aluminiumsliding door bolts plate type with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, 04 Nos on bolt plate and 02 Nos on staple plate and fix complete all as specified and directed. |
| 22 | S & F in repairs 150 mm long Aluminium alloy handles, cast type, anodised complete all as specified and directed. |
| 23 | S & F in repair mild steel 300 mm long ordinary rat rail rod pattern helical door springs, incl roller and roller plate complete all as specified and directed. |
| 24 | S & F in repairMild steel work in framed work such as grills, gratings,framed guard bars, ladders etc., with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work confirming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 25 | S & F in repairs Galvanized mild steel wire cloth, 0.56 mm dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and directed. |
| 26 | S & F Sheet glass 5.5 mm thick, ordinary quality and glazing with oil putty or wooden/aluminium beads exceeding 0.5 Sqm in each pane glazed with putty or fixed with beads complete all as specified and directed. |
| 27 | S & F Sheet glass 5.5 mm thick, ordinary quality and glazing with oil putty or wooden/aluminium beads not exceeding 0.5 Sqm in each pane glazed with putty or fixed with beads complete all as specified and directed. |
| 28 | Hacking out old broken glass (any thickness, size, quality or description) from wooden or metal frames including punching or drilling out old glazing pins/spring clips and providing and fixing new ones or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 29 | S & F Figured glass, 4.0 mm thick, ordinary quality and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane glazed with putty or fixed with beads complete all as specified and directed. |
| 30 | S & F plain glass, 4.0 mm thick, ordinary quality and glazing with oil putty or wooden beads n exceeding 0.5 Sqm in each pane glazed with putty or fixed with beads complete all as specified and directed. |
| 31 | M&L for Plain Cement Concrete Type C1 1:3:6 (using 20 mm graded stone aggregate) as in holdfast and similar work etc complete all as specified and directed. |
| 32 | M&L for Form work to soffits of suspended slabs flat surface of concrete finishedrough surfaces of concrete not exceeding 200mm thick, complete all as specified and directed. |
| 33 | M & L formwork to sides and soffits of lintels,lintel bend, beams etc finished rough surfaces of concrete complete all as specified. |
| 34 | Demolition of Reinforced cement Concrete of any description and in any position not otherwise specifically provided for RCC |
| 35 | M&L RCC 1:2:4 type B1 using 20 mm graded aggregate as in slab, shelves and stair case etc.all as specified and directed. |
| 36 | M&L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed. |
| 37 | M&L brickwork with old size fly ash bricks, straight or curved on plan exc. 6m mean radius built in 1:6 cement mortar including demolition of old brick work complete all specified and directed. |
| 38 | M&L for rendering 15mm thick on other thanfair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cementincluding scrubbing down with water etc complete all as specified and directed. |
| 39 | M&L for rendering 12mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cementincluding scrubbing down with water etc complete all as specified and directed. |
| 40 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement including taking down old plaster from wall including raking out joints, hacking for keys and scrubbing down with water etc complete all as specified and directed |
| 41 | M&L for rendering 12mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement including taking down plaster from wall including raking out joints, hacking for keys and scrubbing down with water etc complete all as specified and directed. |
| 42 | M&L for rendering 10 mm thick on concrete surfaces like ceiling, chajja etc in cement mortar 1:3 and finished even and smooth without using extra cement including taking down plaster from ceiling and scrubbing down with water etc complete all as specified and directed |
| 43 | M&L for preparing newly plastered surfaces of walls and applying two coats of cement based paint complete all as specified and directed. |
| 44 | M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 45 | M&L for preparing new plastered surfaces and applying Two coats of Oil bond distemper over a coatof 2mm thick wall care puttycomplete all as specified and directed. |
| 46 | M&L for preparation of newwood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coat of Synthetic enamel paint (Ordinary tint) over a coat of pink primer complete all as specified and directed. |
| 47 | M&L for preparation of newpainted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primercomplete all as specified and directed. |
| 48 | M&L for preparation of oldwood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed. |
| 49 | M&L for preparation of oldpainted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coats of synthetic enamel paintcomplete all as specified and directed. |
| 50 | M&L for preparation of Old plastered or unplastered surfaces of walls including brooming down or steel wire brushing scrapping down smoke roof, moulds, moss and efflorescent salts and trading oil and greasy spots etc andapplying Two coats of Cement based paint of approved shade/tint complete all as specified and directed. |
| 51 | M&L for preparation of Old plastered or unplastered surfaces of walls including brooming down or steel wire brushing scrapping down smoke roof, moulds, moss and efflorescent salts and trading oil and greasy spots etc andapplying one coats of Cement based paint complete all as specified and directed. |
| 52 | M&L for preparation of Old plastered or unplastered surfaces of wall/roof/Chajja projections including facia, cornices including brooming down or steel wire brushing scrapping down smoke roof, moulds, moss and efflorescent salts and trading oil and greasy spots etc and etc and applying two coat of weather proof exterior emulsion paint upto five story building with necessary scafolding complete all as specified and directed. |
| 53 | M&L for preparation of Old plastered or unplastered surfaces of wall/roof/Chajja projections including facia, cornices including brooming down or steel wire brushing scrapping down smoke roof, moulds, moss and efflorescent salts and trading oil and greasy spots etc and etc and applying onecoat of weather proof exterior emulsion paint upto five story building with necessary scafolding complete all as specified and directed. |
| 54 | M&L for preparation of Old plastered or unplastered surfaces of walls including brooming down or steel wire brushing scrapping down smoke roof, moulds, moss and efflorescent salts and trading oil and greasy spots etc andapplying one coats of oil bound distemper with roller of approved shade/tint complete all as specified and directed. |
| 55 | M&L for preparation of Old plastered or unplastered surfaces of walls including brooming down or steel wire brushing scrapping down smoke roof, moulds, moss and efflorescent salts and trading oil and greasy spots etc andapplying two coats of oil bound distemper with roller of approved shade/tint complete all as specified and directed. |
| 56 | M&L for preparation of Old plastered or unplastered surfaces of walls including brooming down or steel wire brushing scrapping down smoke roof, moulds, moss and efflorescent salts and trading oil and greasy spots etc andapplying one coats of white wash complete all as specified and directed. |
| 57 | M&L for two coats of birla white putty or JK wall putty avg 1.50mm thick with smooth finish by sand papering to achieve smooth surfaces complete all as specified and directed. |
| 58 | M&L for applying two coat of plastic emulsion paints extremely resistant to fungus and algae, peeling, flaking and fading and stay bright.Paints shoud to thick enough to cover minor defects, even surface damage and imperfection in wall etc complete all as specified and directed. |
| 59 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc |
| 60 | M & L for machine cut kota stone slab flooring 18-20 mm thick over and including M & L for 15mm thick cement screedin CM 1:6 laid and jointedwith grey cement slurry mixed with pigment to match the shade of the slab including cutting,rubbing and polishing complete all as specified and directed. |
| 61 | M & L for machine cut kota stone18-20 mm thick slab for skirting, dado, riser etc over and including M & L for 10mm thick renderingin CM 1:4 laid and jointedwith grey cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing and polishingall as specified and directed. |
| 62 | M&L for18-20mm thick granite (approved colour by GE) stone for floor, steps, jambs, pillars, window cills, cooking platform and like machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding, rounding of edges and polishing over and including M & L for 15mm thick screed in CM 1:6complete all as specified and directed |
| 63 | M&L for Non - skid designer coloured ceramic tiles7 to 8 mm thick including borders tiles (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm laid on floor surface jointed and pointed with colouredcement to match over and including M & L for 15 mm thick screed bed or bedding layer of cement mortar 1:6 cementcomplete with dismantling of floor tile including cement mortar bedding all as specified and as directed. |
| 64 | M & L for non- skid designer ceremic colouredtiles7 to 8 mm thick including borders tiles (Square/rectangular) areaof each tile exceeding0.06 Sqm but not exceeding 0.11 Sqm in floors etc set and jointedin neat cementslurry and pointed in whiteor colouredcement to match over and including M & L for 15mm thick screed bed in CM-1:6 complete with dismantling of floor or wall tiling all as spd or as directed. |
| 65 | M&L for coloured printed glazed ceramic tiles 7 to 8 mm thick on walls dado/skirting (square/ rectangular) of 300x200 mm jointed and pointed with colouredcementto match over and including M & L for 10 mm thick renderingof cement mortar 1:4complet withdismantling oftile including cement mortar bedding complete all as specified or as directed. |
| 66 | M&L for coloured Border Glazed designer heighliter printed tiles 7 to 8 mm thick on walls dado/skirting (square/ rectangular) of 450x300 mm jointed and pointed with colouredcementto match over and including M & L for 10 mm thick screed bed or bedding layer of cement mortar 1:4 cement complete withdismantling oftile including cement mortar beddingall as specified or as directed. |
| 67 | M&L forVitrified tiles designer (light shade) 8-10 mm thick including borders tiles (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in walls or cladding or in skirting etc set and jointed in neat cement slurry and pointed in coloured cement to matchover and including M & L for 15mm thick screed bedin CM 1:6 complete with dismentling existing tiles all as specified and as directed. |
| 68 | M&L forVitrified tiles designer (light shade) 8-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to matchover and including M & L for 15mm thick renderingin cm 1:4 complete with including dismantling existing tiles all as specified and as directed. |
| 69 | M&L forVitrified tiles designer (light shade) 8-10 mm thick including borders tiles (square/ rectangular) polished, area of each tilesexceeding 0.36 sqm but not exceeding 0.72 Sqmas in walls or cladding or in skirting etc set and jointed in neat cement slurry and pointed in coloured cement to matchover and including M & L for 10mm thick screed bedin CM 1:3 complete with dismentling of existing tiles all as specified and as directed. |
| 70 | M&L forVitrified tiles designer (light shade) 8-10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but n exc 0.72 sqm eachin floors etc. set and jointed in neat cement slurry and pointed in coloured cement to matchover and including M & L for 15mm thick renderingin cm 1:4 complet with dismantling of existing tiles complete all as specified and as directed. |
| 71 | M&L for 75 mm thick cement concrete, type D 2, 1:4:8 (using 40 mm graded stone aggregate) as in sub base of floor /paving etc complete all as specified and directed. |
| 72 | M & L Proviiding 100mm thick Cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in surface finishing cement concrete surface even and smooth complete all as specified and as directed |
| 73 | M & L for Forming construction joints20mm deepx 10mm vide filled with sealing compound grade \"A\" complete all as specified and as directed |
| 74 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed |
| 75 | M&L for 40 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) in floorings including finishing the surface even and smooth using extra cement including demolition of old concrete complete all as specified and directed. |
| 76 | M&L for Plain Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) as in roof kerbs, coping, benching etc including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 77 | M&L for Plain Cement concrete 1:3:6type C-1, using 20mm graded stone aggregate , in flinth protection 75mm thick finishedeven and smooth without using extra cement including making joint 10-12mmwide to the full depth of PCC at every3 mtrs and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete |
| 78 | S & F 500 Ltr Rotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of old unserviceable water tank capacity exc 250 but n exc. 500 litre complete all as specified and directed. |
| 79 | S & F 1000 ltrs capacity rotational moulded polythylene triple layered water storage tanks white in colour (cylindrical vertical with closed top) hoisted and fixed in position incl dismalting of existing tank and any description all as specified in SSR Part I complete all as specified and directed. |
| 80 | S & F 15 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors including taking up or down of 15mm tubes complete all as specified and directed. |
| 81 | S & F 20 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floorsincluding taking up or down of 20mm dia tubes complete all as specified and directed. |
| 82 | Taking down and Refixing 15mm bore old steel water tubing and connection in new or old position (walls, ceilling, floor etc) complete all as specified and as directed |
| 83 | Taking down & Refixing 20mm bore old steel water tubing and connection in new or old position (walls, ceilling, floor etc) complete all as specified and as directed |
| 84 | S & F in repairs 15 mm bore CP Bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed |
| 85 | S&Fin repair 15 mm bore Bib cock with wall flange and aerator,brass chromium plated with fancy type and screwed down to 15mm bore GI tubing or for brass ferulecomplete all as specified and as directed.Make Jaquar CON-047KN/ Kohler K-16093 IN-4-CP/Grohe-20280000, Approved make & Sample by GE. |
| 86 | S&Fin repair for C P long bodyBib tapscomplete all as specified and as directed |
| 87 | S&Fin repair health faucet 1 mtr SS Braided connection tube with wall hook complete for EWC incl necessary fitting complete all as specified and directed. Make Jaquar ALS-565/Kohler K-77364-IN-CP/Grohe-26355110, |
| 88 | Supply & Fix in Repair ivoryplastic seat cover for EWC closed pattern with flat bottom, and cover and mild steel chromium plated or aluminized hinging devicecomplete all as specified and as directed |
| 89 | S & F in repair fancy type sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with CP bracket gaurd and railling 60 cm long complete all as specified and directed. Make Jaquar CPA-chr-1171/Kohler K-5636-IN-CP/Grohe-40799001/ |
| 90 | S&F fancy type 15 mm bore brass chromium plated WHB mixer for mixing hot and cold water screwed down for iron pipe and fixed to WHB complete all as specified and directed. Make Jaquar CQT-23167B/ Kohler K-8620-IN-CP /Grohe-32734000, Approved make & Sample by GE. |
| 91 | S&Fin repair for C P Wall mixer with provision for overheadshower with 115 mm long bend pipe on upperside connecting legs and flags in repair complete all as specified and as directed |
| 92 | S&Fin repair for C P Sink mixer with short Swinging spout with connecting Lehs and wall flanges complete all as specified and as directed |
| 93 | S&F in repair 1200x900x5.5 mm beveled edge minor of selected quality glass mounted on 5 mm thick PVC sheet and fixed to wooden plugs with chromium plated brass screws and cup washers ) in repaircomplete all as specified and as directed |
| 94 | S&Fin repair for C P Towel ring round with round flangecomplete all as specified and as directed |
| 95 | S&F for C P Soap dish holderin repair complete all as specified and as directed |
| 96 | S&F in repair fancy type stainless steel brass chromium plated towel rail size 600mm long including a pair of brass bracket complete all as specified and directed. Make Jaquar (CAN-1111SM) / Kohler K-25348IN-AF / (Grohe -40366001, |
| 97 | S&F for C P Corner Glass Shelf with Bracket in repair complete all as specified and as directed |
| 98 | S&F in repairs for C P Towel Rack 600 mm long with lower hangerscomplete all as specified and as directed |
| 99 | S&F in repair fancy type brass chromium plated toilet paper holder, complete all as specified and as directed.Make Jaquar CAN-11535/Kohler K-5633-IN-CP/Grohe -40367001/ |
| 100 | S&Fin repairs 20 mm dia Stainless Steel fancy type drapery curtain rod with brackets and lattu & other connected accessories etc complete all as specified and directed. |
| 101 | S&F in repair 15mm bore Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed Make -Jaguar, Cera, Hindware |
| 102 | S & F in repairs 15 mm bore Chromium plated Angle/Stop valves fency type(straight or angular), cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.. |
| 103 | S & F in repairs 20 mm bore gate valve , cast copper alloy complete all as specified and directed. |
| 104 | S&F in repairs Ball valves 15mm dia high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight15 m m - 2 1 0 g m s ) complete all as specified and directed. |
| 105 | S&F in repairs 15mm Nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm-45gms /25mm- 65gms)complete all as specified and directed. |
| 106 | S&F in repairs 450mm long PVC connection 15mm bore with PTMT nuts complete all as specified and directed. |
| 107 | S&F in repairs 32 mm dia PVC flexible waste pipe of approvedquality suitable for sinks/wash basin etc complete all as specified and directed. |
| 108 | S & F in repairs Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing tosteel pipe or unioncomplete all as specified and directed. |
| 109 | S & F in repairs Chromium platedoverhead shower rose 150x150mm Squarel Shape single flow (ABS Body)with Rubit Cleaning System, including fixing tosteel pipe or union complete all as specified and directed. |
| 110 | Supply and fix in repair 600mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thickAC building board or commercial plywood on PVC frame complete all as specified and directed. |
| 111 | S & F in repairs Fancy type chromium plated with long shank and cup (Concealed type) 15 mm bore Stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions. |
| 112 | S&F in repair 15 mmbore brass chromium plated , pillar taps fancy type, cast copper alloywith capstan heads screwed down high pressure screwed for iron pipe with or without lettered \"Hot\"or \"Cold\"with long screwed shanks and fly nutsor as specified or as directed. |
| 113 | S&F in repair 15 mmbore brass chromium plated , pillar taps fancy type, cast copper alloywith capstan heads screwed down high pressure screwed for iron pipe with or without lettered \"Hot\"or \"Cold\"with long screwed shanks and fly nutsor as specified or as directed.. |
| 114 | S & F in repair Sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers, waste coupling and waste pipe including bedding in cementmortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915 mm x 460 bowl size 410mm x 330mm x 250mm fixed complete all as specified and directed. |
| 115 | S&F in repair vitreous China Urinal half stall type white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement mortar 1:3 including PTMT spreader, PTMT waste coupling, PVC waste pipe complete all as specified and directed. |
| 116 | Supply and Fixing in repairs Vitreous China Ware Urinal partition slabs 310x700 terminating about 40 cm above floor line complete all as specified and directed. |
| 117 | S & F in repairs Vitreous China Squatting pan of Orissa pattern, size 580x440 mm size white with integral foot rest with Cast Iron `P\" or `S\" trap, front or back inlet andincluding connection to trap and to flushing pipe, anti-syphonage pipe etc., including trap set in and including lime concrete bedding complete including making good to floor (excluding flushing cistern and flush pipe)all as specified and directed. |
| 118 | S & F in repairs Single piece WC with UF Soft Close Slim Seat Cover , Hinges, Dual flush Cistern Fitting, fixing Accessories , size 360x655x765 mm, including trap set in and including lime concrete bedding complete including making good to floor all as specified and directed.. |
| 119 | S & F in repairs EWC with Standard Star Seat and Cover , Hinges, Dual flush Cistern Fitting, fixing Accessories , size 530x380x400 mm with east cover , including trap set in and including lime concrete bedding complete including making good to floor all as specified and directed. |
| 120 | S & F in repairs Vitreous China Ware Wash hand basin flat back, size 550x400mm in repairs including cutting for and pinning ends of brackets including PTMT waste coupling and PVC waste pipe 32 mm dia and PVC connection 450mm long with PTMT nuts and fixed on a pair of MS cantilever bracket of appropriate size complete all as specified and directed. |
| 121 | S & F in repairs Vitreous China Ware Wash hand basin counter top, size 565x450x195mm including PTMT waste coupling and PVC waste pipe 32 mm dia and PVC connection 450mm long with PTMT nutsand other fixing arrangement complete all as specified and directed. |
| 122 | S & F in repairs table mounted sensor basin tap with necessary fixing arrangement complete all as specified and directed. |
| 123 | S & F in repairs sensor fitted urinal pot with complete filushing valve for urinal with complete set with installation boxcomplete all as specified and directed. |
| 124 | S&F in repairs vitreous china full stall urinalwhite, with grating and union for discharge pipe including waste pipe of polythelene of low or high density or PVC 32mm dia complete all as specified and directed. Make Jaquar- URS-WHT-13261H, Kohlelr K-4991-ET-O/Grohe -39438000. |
| 125 | S&F in repair Urinal spreader of brass chromium plated selected colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed. |
| 126 | S & F in repairs 10 litres PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including 32mm PVC pipe for low level cistern L type, brackets fixed on wall complete all as specified and directed. |
| 127 | S & F in repair bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms/ 40mm-270 gms complete all as specified and directed. |
| 128 | Taking down AC/PVC rain water pipe, soil/waste/vent pipe of any size with fittings etc. |
| 129 | S & F 110 mm bore PVC (SWR) Soil, waste and vent, rain water pipes, drain pipe single socketed in any length with rubber ring joints fixed on walls complete all as specified and directed. |
| 130 | S & F in repair 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed. |
| 131 | S & F 75 mm bore PVC (SWR) Soil, waste and vent, rain water pipes, drain pipe single socketed in any length with rubber ring joints fixed on walls complete all as specified and directed. |
| 132 | S & F in repair 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed. |
| 133 | Repairing of aluminium door/window etc of any size / any number of panels including taking down & refixing (if required) for easy closing/ opening/ tightening of hinges or changing the position of hinges, adjustment of floor door spring of hydraulic door closure, adjustment of tower bolts, sliding bolts etc changing of mortice lock complete all as specified and directed. |
| 134 | Supply and fix in repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed. |
| 135 | Supply and fix in repairs Powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc.complete all as specified. |
| 136 | S&Fin repairs Powder coated anodised Aluminium door shutters pull and push type (with or without aluminium sash bars)including necessary jointing cleat, glazing clip, rubber packing anodized aluminium beading, screws, etc and panel inserts of 5mm thick tinted glass/ prelaminated particle board (Novapan) panel in each door and making good of wall surface to match existing surface complete all as specified and directed. |
| 137 | S&F in repairs Powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.)fixed in vertical position with aluminium vertical members and specifiedthick tinted glass including rubber beading and aluminium glazing clips complete all as specified. |
| 138 | S&F in repairs Powder coated aluminium sliding windows frame with movable shutter ( sliding on minimum two PVC roller of best quality, for each shutter on threetracks with stainless steel mosquito proofing and glazing shutter and incl 5.50 mm thick glass & stainless steel wire mesh fixed with neoprene rubber gasket with aluminium beading, clips,frame made with aluminium section as appended below- (i) Window frame :68.4x38mm X 1.15 mm thick for three tracks.(ii) Top/bottom rail and style / rail of shutter : 15x37.5x1.15 mm thick and over. (iii) Aluminium beading - 0.7mm thick (iv) stainless steel wire cloth 0.45mm nominal dia of wire and average width of aperature 1.40mm and fixed in aluminium window or alongwith F/Y section fixed with aluminium wire staples complete.(v)Aluminiumfittings suchaluminium suitable handle with auto interlock cap with suitable size .(vi) Making good of wall surfaces with silicon to match with existing surfaces complete all as specified |
| 139 | S&F in repairs for mild steel grill/guard barsfor window/ventilators or forged into spikes, framed balusters, walkway railing and similar work including welding, FE-290 grade E-165 complete all as specfied and directed. |
| 140 | M&L in repairACP as in cladding/panelling 3 mm thick on GI frame 0.75 x 0.45 m fixed to wall or RCC column with screws by drilling holes & jointed sealed with silcon all as per manufacture instructions. |
| 141 | M&L10-12 mm thick toughen glass work in doorwith stainless steel tubes glass door and its floor mounted door frameless selected quality with necessary beading/packing, stailess steel handles of appropriate size and necessary fittings and fixtures with top patch fitting user for frameless glass door used with pivot pin attached tempered glass over panel patch with pivot including patch lock bottom patch top patch for SS patch fitting over panel side panel connector double pivot patch for back to back door with fin wall mounted over panel patch with pivot lintel incl top pin top pivot bottom hinge floor spring for two way door opening glass bracket fittings ,glass clamps and one piece alloy cabinet door lockfixed in repairto wall or RCC column with screws by drilling holes & jointed sealed with silcon tap all as per manufacture instructions. complete. |
| 142 | M&L in repairs Aluminium partition frame work anodized powder coated frame of size 62.5 mm x 37 mm x 2.5 mm thick with bottom & middle rail of section 62.50 mm x 37 mm x 2.5 mm thick and styles, top rail of section 62.50 x 37 x 2.5 mm thick including jointing cleats, fixing of glazing with 5.5 thick ordinary plain glass or 5 mm aluminium composit panel including taking down old existing partition workincluding necessary fittings fixtures complete |
| 143 | S&FAluminium body(die cast) door closer hydraulically regulated, designation No. 2 universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 Kgcomplete all as specified and directed. |
| 144 | Supply and fix in repair 140mm long Floor door stopper made of double Aluminium rod and hard rubber shoe fixed with steel screws complete all as specified and directed. |
| 145 | S&F Tinted sheet glass 5.5mm thick, pin head typein squares exc 0.5 sq. m in each pane in Aluminium window,door and partition wall complete all as specified and directed. |
| 146 | S&F in repairs Flush kit complete for Flushing cistern for repair complete all as specified and directed. |
| 147 | S&F in repair Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed. |
| 148 | M & L for Providing water proofing treatment to RCC sunken slab as specified and directed as under:- (a) Cleaning the existing RCC sunken slab and vertical wall/RCC beam and hacking the surface. (b) 15mm thick plastering over the floor & vertical surface in CM 1:4, mixed with liquid water proofing compound @ 200ml per 50 kg of cement trowelled to even and smooth finish without using extra cement .(Water proofing compound shall be measured and paid separately). (c ) filling the sunken portion with water for 72 hrs and carring out the ponding test.(Any leakage /seapage noticed shall be repaired). (d) Applying two coats of elastomaric acrylic water proof coating in each coat with roller application.(Note: Each coat of elastomaric acrylic compound requires 6-8hrs to dry up itself second coat shall be applied on getting the first coat completely dried up.) |
| 149 | Supply only liquid waterproofing compound all as specified. |
| 150 | S&F 32mm dia GI pipe, medium grade as in spout pipe in sunken floor complete all as specified and directed. |
| 151 | S&F Prelam hollow PVC sheet wall panelling of thickness 4mm consisting panels of desired size stuck on inner frame work of 35mm wide strips of 5mm thick PVC sheet. The PVC strips shall be fixed to the wall using 65mm long MS screws through the groove in the strip by using PVC fastners. The distance between two screws shall not be more thant 200 mm. The strips shall be fixed to wall vertically at an equal interval of 10\" between two PVC strips.A strip of 5mm thick PVC sheet of width 75mm feathered at edges shall be stuck at theplaces where two panels are jointed, using solvent cement and including taking down existing PVC wall paneling complete all as specified and directed. |
| 152 | M&LPOP (Plaster of Paris) false ceiling applying 10 to 12 mm thick POP finish over ceiling surfaces with wall care putty mixed with POP powder in ratio of 1:10 (a) PGI sheet of 26 gauge inangle shape of size 25 x 25 mm all around the wall complete.(b) Main runners of 26 gauge PGI sheet inangle shape of size 35 x 25 mm at the interval of 90 cm centre to centre complete. complete includingone dome not less than 1 metre dia and frame work complete all as described below : (c) Cross runners of 26 gauge PGI sheet in angle shape of size 35 x 25 mm at 40 cm center to center complete.(d) Suspender/ hanger of 26 gauge of PGI sheets in angle shape of size 25 x 25 mm fixed to soffits of roof by steel fastener complete.Including Dismantling ofplaster of paris ceiling (Gypsum anhydrous) to flat surface including framework and G.I. wire mesh complete all as specified and directed. |
| 153 | Making POP cornices 75/100 mm wide of required design as directed by Engineer-in-charge. |
| 154 | Making POP Dome design( dia exc 90 cm but n.exc 120 cm)of required design as directed by Engineer-in-charge. |
| 155 | S & F in repairs 4mm thick E-Board tiles for insulation and acoustic purpose of size 600x 600mm fixed with and including anodised GI prepaintedsnap grid with 25x25x1.5 mm thick Tee section and 38x25x2 mm thick angle with hanging/supporting arrangements as in false ceiling at bottom at spacing 60 cm centre to centre including necessary GI cleats and 4mm dia GI wire as suspender fixed to ceiling not exceeding 1.20 mtr centre both ways with dash fastners complete and making good disturbed surfaces including taking down old ceiling complete allas specified and directed. |
| 156 | Dismantling of AC sheet corrugated / Semi corrugated sheets in wall cladding or in roof covering complete all as specified and directed. |
| 157 | M&L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws complete all as specified and directed. |
| 158 | M&L for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws complete all as specified and directed. |
| 159 | M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc complete all as specified and directed. |
| 160 | M&L for Asbestos cement one piece plain angular ridge 6mm thickcomplete all as specified and directed. |
| 161 | Dismantling of timber scantling in fillets, rails, posts, rafters, purlins, etc. any section complete all as specified and directed. |
| 162 | M & L for second class hard-wood in roof truss / timber scantlings clean sawn any description complete all as specified and directed |
| 163 | M & L for roof trusses, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 164 | Notes:- Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail