| 1 | Taking down carefully existingceiling fan of any size/sweep/make from it\"s existingposition, replacement of defective spare parts and re-assembling and refixing/hanging in the same or different locationconnecting with flexiable cable of suitable size & length including testing complete all as specfied and as directed.Note : Cost of spare parts and flexible connection wire asrequired will be measured and paid separately under respective items of this Schedule as \"Supply only\". |
| 2 | All as per item No 1 above but to exhaust fan/ wall fan of any sweep/any make. |
| 3 | Dismantling ceiling fan (any size/sweep/make) and taking out existing burnt out winding wire of motorand rewinding the same with super enamelled copper wires of 99.99% Copper purity (Qty of winding wire 200 gram to 250 gram per fan) as per existing gauge and turn to achieve the desired RPM, cleaningandreplacement of bearings, bushes, capacitor etc as required and testing complete on completion for old modelceiling fan complete all as specfied and as directed.Note : (a) Replacement of unserviceable parts like capacitor, bearing, bush and flexible wire shall be measured and paid separately as \"Supply only\" under respective items of this Schedule. (b) Ceiling fan shall be collected from MES Store of GE Dinjan and deposited to Store after repair for inspecting, cost of which is deemed to be included in unit quoted rate. |
| 4 | Dismantling of exhaust fanany make and taking out existing burnt out winding wire of motor and rewinding the same with super enamelled copper winding wires of 99.99% Copper purity (Qty of winding wire 150 gram to 200 gram per fan) as per existing gauge and turn to achieve desiredRPM including cleaning and replacement of defective parts as required for exhaust fan of size up to 380 mm sweep and testing all complete all as specfied anddirected.Note : (a)Replacement of unserviceable parts shall be measured and paid separately as \"Supply only\" under respective items of this Schedule. (b) Exhaust fan shall be collected from MES Store of GE Dinjan and deposited to Store after repair for inspecting, cost of which is deemed to be included in unit quoted rate. |
| 5 | All as per item No 4 here-in-before but exhaust fan/ wall fan of450mm to 600mm sweep (Qty of winding wire 200 gram to 250 gram per fan) complete all as specified and directed. |
| 6 | All as per item No 4 here-in-before but wall fan ofsize 650mm sweep and above of single phase type (Qty of winding wire 200 gram to 250 gram per fan) complete all as specified and directed. |
| 7 | M&L for fan shaft by filing metal cutting by machine, grinding, polishing complete and making the same in serviceable condition suitable for existing ceiling fan of any capacity complete all as specfied and directed. |
| 8 | S&F in repair anti suicidal fan rod with load sensitiv mechanism that disconnects or collapses when excessive downward force is applied having spring loaded pin or shear pin or magnetic coupling which detaches when 20-30 kg load is applied made of high grade steel or aluminium coated with corrosion resistive powder all complete as specified and directed. |
| 9 | Supply only capacitor (oil filled) of capacity 2.0 mfd complete all as specfied and directed.Make : Havells/Universal /Tibcon/Usha. |
| 10 | Supply only capacitor (oil filled) of capacity 2.5 mfd complete all as specfied and directed.Make : Havells/Universal /Tibcon/Usha. |
| 11 | Supply only capacitor (oil filled) of capacity 3.15 mfd complete all as specfied and directed.Make : Havells/Universal /Tibcon/Usha. |
| 12 | Supply only ball bearing No 6200 complete all as specfied and directed.Make : TATA/SKF/NBC. |
| 13 | Supply only ball bearing No 6201 complete all as specfied and directed.Make : TATA/SKF/NBC. |
| 14 | Supply only ball bearing No. 6202 complete all as specfied and as directed.Make : TATA/SKF/NBC/HCH. |
| 15 | Supply only ball bearing No 6203 complete all as specfied and directed.Make : TATA/SKF/NBC. |
| 16 | Supply only ball bearing No 6204 complete all as specfied and directed.Make : TATA/SKF/NBC. |
| 17 | Supply only ball bearing suitable for exhaust fan of upto 380 mm sweep complete all as specfied and directed.Make : TATA/SKF/NBC. |
| 18 | Supply only ball bearing suitable for exhaust fan of 450 mm to 600 mm sweep complete all as specfied and directed.Make : TATA/SKF/NBC. |
| 19 | Supply only gun metal bush suitable for any type of ceiling fan complete all as specfied and directed. |
| 20 | Supply only gun metal bush suitable for any type and any sweep of wall fan/exhaust fan complete all as specfied anddirected. |
| 21 | Supply only flexible wire twisted twin core of size 0.75 Sqmm, copper conductor complete all as specfied and directed.Make : Finolex/ Havell\"s/KEI/Polycab. |
| 22 | M&L for one coat synthetic enamel spray painting to complete ceiling fan upto 1400mm sweep after detaching blades and filling cavities with filler including necessary preparation of surface duly demarking MES fan serial Nos, refixing the blades and re-writing MES Fan serial number complete all as specfied and directed. |
| 23 | All as per item No 22 above but to exhaustfan/ wall fan upto 380mm sweep |
| 24 | All as per item No 22 above but to exhaustfan/ wall fan from 400 to 600mm sweep. |
| 25 | M&L for cutting holes in circular shape in brick walls exceeding half brick but not exceeding one brick thick in cement mortar for fixing exhaust fan and making good to disturbed surfaces in cement mortar (1:3) finished even and smooth and finishing the same to match with existing surface as required complete all as specfied and directed. |
| 26 | S&F in repair down rod heavy duty with 20mm dia MS rod for hanging ceiling fan not exceeding 0.5 mtr and fixing complete including joist of suitable size, nuts, bolts and washer with 2 Nos rubber insulator including drilling holes as required including necessary painting to match with colour of fan complete all as specfied and directed. |
| 27 | S&F in repair mild Steel \"S\" shape clamp made out of flat iron of size 25 x 6 mm with nuts and bolts of appropriate size as required for hanging of ceiling fan and necessary painting etc complete all as specfied and directed. |
| 28 | S&F in repair rubber insulator reel type suitable for fan hook of any type complete all as specfied and directed. |
| 29 | S&FPVC canopy set one as per existing specification as approved complete all as specified and directed. Make- Crompton/Havells /Bajaj |
| 30 | S&F Plastic body 150 mm sweep exhaust Fan model Havells Ventil Air DX type suitable for 220 V including flexible wire of suitable size & length,complete all as specified and directed. |
| 31 | S&F exhaust fans AC single phase 230/ 240 V of size 225 to 230 mm sweep light duty including flexible wire of suitable size & length complete all as specified and directed. Make- Crompton Drift Air Plus Metal Anti Dust or equivalent make as specifed in PS. |
| 32 | S&F Ceiling fan 1200 mm sweep white in colour modern, decorative type ,suitable for 220 volts,energy efficient BLDC fan including flexible wire of suitable size & length complete all as specified and directed.Make-Havells (enticer prime/epic signia)or crompton( avencer anti dust) or Atomberg (Renesa) or equivalent to make as specifed in PS. |
| 33 | S&F Ceiling fan 1200 mm sweep white in colour modern, decorative type ,suitable for 220 volts,energy efficient BLDC fan voice controlled, remote contolled, high air delivery 5 star rated including flexible wire of suitable size & length complete all as specified and directed. Make-Havells stealth air BLDC voice 2.0or equivalent in crompton or Bajaj or equivalent to make as specifed in PS. |
| 34 | S&F Power circuit board for BLDC Fan suitable for 26 Watt to 35 Watt having 180-260 V,50 hz with speed steps of 5-6 levels with efficiency >85% with over voltage/under voltage/under current/under voltage/ short circuit and over temperature protection of any make / capacity as per model /sample complete all as specified and directed. |
| 35 | S&F PVC holder for holding capacitor (condenser housing) of any size in ceiling fan complete all as specified and directed. |