| 1 | Demolition of cement concretein ground floors and pavings not exc 15cm thick complete all as specified and directed. |
| 2 | Material and labour for 40mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in floor finished even and smooth with out using extra cementcomplete all as specified and directed . |
| 3 | M&L for 25mm thick PCC 1:2:4 type B0 using 12.50mm graded stone aggregate as in floor, including rough finished with out using extra cement. |
| 4 | Dismantling of floor,hearth or wall tilling including cement mortor bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 5 | M & L for non skid coloured ceramic tiles 7 to 8mm thick square / rectangular area of each tile exc 0.11 Sqm but not exc 0.18Sqm as in floor laid over 15 mm thick screed bed in CM 1:6 as in floor etc. set and jointed in neat cement slurry and pointed in coloured cment to match colour tiles complete all as specified. |
| 6 | M & L for Glazed ceramic colouredtilesin vertical surface 350x250x7mm/ 450x300x7mm thick, set and jointedin neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering in cm 1:3 complete allas specified. |
| 7 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed |
| 8 | Material and labour for machine cut kota stone slab 20-25 mm thick (of size not less than 55 cm x 55 cm) laid and jointed with grey cement slurry mixed with pigment to match shade of the slab including cutting, waste, rubbing and polishing (Granite finish) over and including cement screed bed 20 mm thick in cement mortar (1:6) baseincluding rubbing and mirror polishing, complete all as specified. |
| 9 | M & L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing completeand including 20mm thick screed bed in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing complete all as specified and as directed. |
| 10 | Demolition of brickwork built in cement mortar including all quions, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and directed. |
| 11 | Material & labour old size brick work with sub class \"B\" bricks in CM 1:6 brickstraight or curved on plain exeeding 6m mean radius complete all as specified and directed. |
| 12 | Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 13 | M & L for rendering 15mm thick on other than fair faces of brick or concrete surfaces in cement plaster 1:4 using WPC 3% by weight of cement (WPC to be measured and paid separately) and finished even and smooth (without using extra cement). |
| 14 | M & L for rendering 12mm thick in CM (1:6) on brick work or concrete surfaces finishing even and smooth without using extra cement complete all as specified and directed. |
| 15 | Material and Labour for 5mm thick cement plaster in CM (1:3) to ceiling surfaceand finished the surface even and smooth without using extra cement complete all as specified. |
| 16 | Supply only integral water proofing compound of approved brand/make. |
| 17 | M & L for preparation of new plastered surface of wall and applying two coats of cement base paint with alkali resistant priming paint complete all as specified and directed. |
| 18 | M & L for preparation of new plastered surface of wall and applying two coats of distemper oil emulsion over a coat of chalk whiting as a preparatory to distempering complete all as specified and directed. |
| 19 | M & L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 20 | Taking down Chowkhats or frames exc 1.5 sqm but not exc. 4 sq. m eachwith shutters (without taking off shutters from the frames) |
| 21 | Taking down door chowkats or frames with shutter (without taking out shutter fromframe ) area not exc 1.50 m . |
| 22 | S & F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube supplying & fixing in opening as per specified & drawing. |
| 23 | S&F Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C\" channel heaving a PVC sheert strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 24 | S&F, Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc.complete as specified, Supplied and Fixed. Size of frame 105x60mm |
| 25 | S&F, Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc.complete as specified, Supplied and Fixed. Size of frame 125x60mm |
| 26 | S&F Butt hinges (ISI marked), medium weight, cold rolled mild steel of size 100 mm. |
| 27 | S&F 150 mm Aluminium anodised, barrel tower bolts of extruded section and fixed all as spd. |
| 28 | S&F 150 mm extruded aluminium alloy handles, fabricated type anodised complete all as specified. |
| 29 | S&F125 mm long,aluminium,anodised, barrel tower bolts of extruded section all as directed. |
| 30 | S&F 125 mm size aluminium handles,cast type,anodised all as directed. |
| 31 | S & Fin repair300 mm aluminium alloy, anodised sliding door bolt ISI marked with hasp, staple (bolt type) and fixing clips of sheet, cast of extruded sections and fixing bolts and sliding bolts of extruded sec or cast aluminium and fixed complete all as specfied and directed. |
| 32 | M&L Aluminium powder coated (powder coated of requried colour) three track sliding windows frame top & sides of size 92x31.75x1.50 mm (section No 20831), bottom size 92x31.75x1.50mm (section No 20832) and shutter top & bottom of size 40x18x1.55mm (section No 20736) and sides (handle) of size 40x18x1.55mm (section No 20738) and lock side shutter frame of size 40x18x1.45mm ( section No 20737)\" with including and fixing rubber gasket, beading and locking arrangement including making good to the disturbed portion complete including & fixing stainless steel wire mesh 0.36mm nominal dia of wire with 1.40mm average aperture and fixed with stainless steel wire staples and including and fixing 5mm thick glass with necessary rubber beading gasket etc including necessary plaster, painting ,cill and making good to disturbed portion all as specified and as directed by Engr-in-charge. |
| 33 | S&F aluminium powder coted ventilator louvers type frame top and bottom of size 31x42x1.60mm(sec no-20558) rectaular tube of size 40x20x2 mm (sec no-14019 and middle verticalof size 42x46.20x1.60mm sec(20560) and clip for fixing wiremesh and glass of size 19x17.30x0.90mm (sec no-19360)thick including and fixingstainless steel wire cloth 0.36mm niminal dia of wire and 1.40mm average width of aperature and fixed with stainless steel wire staples and supply and fixing 5mm thick louvers with blades of 100 mm heavy duty with neccessary rubber beading ,gasket etcincluding necessary plaster, painting ,cill and making good to disturbed portionall as specified and directed by Engr-in-Charge |
| 34 | Supplyand fixing factory made flush shutters 40 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides, ISI marked complete all as specified. |
| 35 | S & F 35 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc fitted to chowkhats for doors etc complete. |
| 36 | Dismantling wall and ceiling board or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specfied and directed. |
| 37 | M&L for suspended false ceilling comprising of 6mm thick non asbestos fibre cement bulding boards fixed or laid/inserted to GI frame work with screws over Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified |
| 38 | Dismantling water tanks of capacity exc 250 & n exc 500 litres and removing to store all as specified and directed. |
| 39 | Dismantling water tanks of capacity exc 500 & n exc 1000 litres and removing to store all as specified and directed. |
| 40 | S&F500 Ltrs capacity PVCRotational Moulded polyethylene water storage tanks (Cylindrical vertical with closed top)double layer hoisted and fixed in position all as specified. |
| 41 | S&F1000 Ltrs capacity PVCRotational Moulded polyethylene water storage tanks (Cylindrical vertical with closed top)double layer hoisted and fixed in position all as specified. |
| 42 | S&F in repair ball valve/float ballhigh pressure of PTMT 20mmwith epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed minimume weight 210 gm etc all as specified and directed. |
| 43 | Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store all as specified and directed. |
| 44 | Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store all as specified and directed. |
| 45 | Supply and fixing steel water tubing of 15 mm bore, medium grade galvanized with provision of all new fittings as required, laids in floor , wall and on ceiling, complete all as specifiedand directed . |
| 46 | Supply and fixing steel water tubing of 20 mm bore, medium grade galvanized with provision of all new fittings as required, laids in floor , wall and on ceiling, complete all as specifiedand directed . |
| 47 | S & F in repairs bib taps 15mm diafancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 48 | S & F in repairs 15mm dia stop valves / angle cockfancy type chromium plated, screwed down,screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 49 | S & F in repairs15mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 50 | S & F in repairs 15mm dia brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed all as specified and directed. |
| 51 | Supply and fixed (in repair) PVC connections 45cm long and 15mm dia with chromium plated brass nuts and PVC washers on both ends, complete all as specified. |
| 52 | S & Fin repairs vitreous china wash basin, white flat back, size 550 X 400 mm excluding taps, chain and plug and porcelain stopper but including brackets, waste coupling, waste pipe etc complete all as specified and directed. |
| 53 | S & F in repairs vitreous China Water closet squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including provision of lime concrete beddingcomplete all as specified and directed. |
| 54 | S & F in repairs PVC valveless, syphonic action type, flushing cistern of 10 ltrs capacity, high or low level, white, with inlet, ball valve, float and handle including brackets, and connections to flush pipes of polyethylene of low or high density or PVC. 32 mm dia, for low levelcistern complete all as specified and directed. |
| 55 | S & F in repairs 600mm X 450mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed. |
| 56 | S & F in repair Soap dish, any type, fixed to plugs with chromium plated brass screws embedded in the wall all as specified and directed. |
| 57 | S & F in repairs 20 mm dia brass chromium platedtubular towel rail, D type, 60cm long between flanges complete all as specified and directed. |
| 58 | Hacking out old glass (any thickness,size,quality or description)from wooden frames or stone,concrete or brick surrounds ,glazed with putty or fixed with beads complete all as specified and as directed. |
| 59 | Supply and Fix plain sheet glass/pin headded glass of 4 mm thick in Squares not exceeding 0.50 Sqm in each pane with oil putty and clips complete all as directed by Engineer-in-Charge. |
| 60 | S&F in repairs galvanised mild steel wire cloth, 0.56mm nominal dia wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staple,wooden beads or galvanised steel small nut and bolts etc. |
| 61 | S & F in repairs stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size915mmx460mm with bowl size 410mm x 330mm x 160mm all as specified and directed. |
| 62 | S&F for in repair Brass chromium plated shower rose 125mm size Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union |
| 63 | S&F in repair C.P. grating 100mm square/round with or without hole. |
| 64 | Supply and fixing ( in repair), PVC waste pipe for wash hand basin/sink, 32mm dia and80 cm long plain pipe, complete all as specified. |
| 65 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specfied and directed. |
| 66 | S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/clading to wall, fixed with self tapping screws as specified including dismantling plain or corrugated steel sheeting, any gauge, thickness, in roof covering complete all as specfied and directed. |
| 67 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 68 | M&L Framed work such as grills, gratings, etc.. with ends of barsshouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming toto Fe.290.Gde-E-165 including tading down old unserviceable complete all as specfied and directed. |
| 69 | Dismantling timber scantlings frame workunder 40 sq. cm in section, in anyposition complete all as specified and directed. |
| 70 | M&L for 2nd class hard woorkexc 13 Sqcm and not exc 25 Sqcm Plain fillets square, rectangular or triangular in section, wrought, secured with nails or brads complete all as specified and directed. |
| 71 | M & L for preparation of Newwooden surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 72 | M&L Water proofing treatment on \"Non approachable / non accessible and approachable roof\" surface (Horizontal & Vertical surfaces) in sequence through manufacturer / authorized applicator of the manufacturer including,properly cleaning & drying the concrete surfaces Priming surfaces and applying normal treatment (for moderate conditions) using glass fibre base bitumen felt, grade 2 all as specified. |
| 73 | As per item No 72 but forApplying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 kg/ Sqm incl cleaning surfaces. |
| 74 | As per item No 72 but for Laying /unrolled over the bitumen coated surface, APPbasedpolymericmembraneminimumweighing3kg/sqmandminimum3mmthickreinforced with polyster non wove fabric (wt. notless than 150 gms/sqm)land on primed surfaceby forced application complete all as specified with 100 mm over laps shall be sealed by flame as per manufacturers instruction. |
| 75 | As per item No 72 but for Applying two coats of bituminous aluminium paintincluding preparation complete |
| 76 | M&L for PCC 1:2:4 type B0 (Using 12.50mm gradedstone aggregate) in roof padding/kerbs/sunken slab etc complete all as spd and directed, |
| 77 | M&L for taking down carefully copper/aluminium point wiring(light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking creditand making good the disturbed surfaces of walls, floors, etc.complete. |
| 78 | M&L One light point controlled by one switch for point re-wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm Phase - Red, Neutral - Black and earth continuity conductor 1.5 sqmm Green) drawn into and including PVC casing-caping not less than 32x12 mm ISI marked ivory colour with all fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm including covered with modular plate and frame white for mounting switches, sockets, fan regulators as required complete all as specified and directed. |
| 79 | As per item No 78 but for one fan point controlled by one switch. |
| 80 | As per item No 78 but for one light point controlled by two, two way switches. |
| 81 | As per item No 78 but for one socket outlet 6 amp controlled by one switch on the same board with other switches. |
| 82 | As per item No 78 but for one socket outlet 6 amp controlled by one switch on indepdendent board. |
| 83 | As per item No 78 but for one bell point controlled by one bell push. |
| 84 | M&L for point re-wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 2.5 sqmm (Green) drawn into and including PVC casing-caping not less than 25x12 mm ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm including covered with modular plate white forone 16 amp socket outlet controlled by one switch on independent board. |
| 85 | S&F modular switch one way 6 amp 1 module complete all as specified and directed. |
| 86 | S&F modular switch one way 16 amp 1 module complete all as specified and directed. |
| 87 | S&F modular switch two way 6 amp 1 module complete all as specified and directed. |
| 88 | S&F modular bell push, 6 amp, 1 module complete all as specified and directed. |
| 89 | S&F call bell, AC, 240 volts, single pole complete all as specified and directed. |
| 90 | S&F modular socket6/16 - 2/3 pin combined 2 modulecomplete all as specified and directed. |
| 91 | S&F modular socket 6 amp 2/3 pin combined 2 module complete all as specified and directed. |
| 92 | S&F modular hum freeelectronic step fan regulator, 100 watt 2 module complete all as specified and directed. |
| 93 | S&F angle holder, insulated polycabonate body with back plate complete complete all as specified and directed. |
| 94 | S&F ceiling rose 3 plates polycarbonate body completeall as specified and directed. |
| 95 | S&F LED Smart bright batten (1150mm) made of PC housing integrated LED driver with a PC glossy difusser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not less than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95complete all as specified and directed. |
| 96 | S&F LED Smart bright batten (600mm) made of Aluminium housing integrated LED driver with a PC glossy difusser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not less than 9 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95complete. |
| 97 | S& F decorative wall mounting brushed nickel finish fixture with opal glass diffuser suitable with 2x9 Watt LED lamp base of B22 complete all as directed. |
| 98 | S&F in renewal 20 amp, single pole and neutral, socket outlet, with 2 pole and earth, metal enclosed plug top in power coated CRCA steel sheet enclosure recess mounted with chained cover for the socket outlet with and including one number single pole \"C\" series MCB 16/20 amp as required. |
| 99 | S&F SPN DB (Double Door), 240 volts, 4 ways MCB distribution board powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 54 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with complete all as specified and directed. |
| 100 | As per item No 99 but for SPN DB (Double Door), 240 volts, 8 way complete all as specified and directed. |
| 101 | S&F Single pole 6 to 32 ampMCBs of\"C\" series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed. |
| 102 | As per item No 101 but for Doublepole 10 to 32 amp complete all as specified and directed. |
| 103 | Taking down MCB distribution boards with incoming and outgoing controls any make, any capacity after disconnecting complete. |