| 1 | Note :- (i) Work to be carried out on GL to 22th floor (including terrace of building) from ground levels (ii) Rate for scaffolding and safety system for labour are included in quoted rates by Contractor. (iii) Safety Net and Water Proofing covering materials shall be arrange by Contractor while working at Site and it will be deem fit in quoted rates by Contractor. (iv) All items related to B/R and particular External Plaster, Painting/Periodical, Chajja Plaster Plumbing and Sanitary Items scaffolding, Jhula, Rope System shall be arrenged by Contractor in quoted rate. Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, jambs etc complete all as specified and directed by Engr-in-Charge. |
| 2 | Taking down cement plaster of any description on brick work or stone masonry walls including rackingout joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engr-in-Charge. |
| 3 | Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed by Engr-in-Charge. |
| 4 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr-in-Charge. |
| 5 | Demolition of (reinforced) cement concrete (reinforcement cut as required to facilitate demolition) of any description in any position not otherwise specifically provided for complete all as specified and directed. |
| 6 | M&L Cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in foundations or mass concrete complete all as specified and as directed by the Engr-in-Charge. |
| 7 | M&L brick work with sub class \"B\" old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engr-in-Charge. |
| 8 | M&L 15mm thick rendering in cement mortar (1:6) on brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L 15mm thick rendering cement mortar (1:4) mixed with liquid water proofing compound onbrick work or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified and directed by Engr-in-Charge. (WPC shall be paid seperately) |
| 10 | Supply only liquid water proofing compound |
| 11 | M&L reinforcement cement concrete type B-1 1:2:4slab supported on wall (20 mm graded stone aggregate)for slab supported on walls, beams and columns in floors , roofs landings, balconies, canopies deck slab and in shelves and the like all as specified and directed. |
| 12 | M&L for reinforced precast cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in landings, cover slabs (for manholes etc.), shelves and similar articles with plain faces including necessary form work, set in cement mortar 1:4 completeall as specified and directed. (Note:- Reinforcement shall be measured and paid for separately under respective item of schedule \"A\"). |
| 13 | S&F reinforcement of mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoopingfor columms,hooking ends and binding with and including mild steel wire annealed not less than 0.90 mm dia or securing with clips all as specified and directed. |
| 14 | M&L for MS deformed bars (TMT) 6 -8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 15 | M&L for Formwork to flat soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surfaces complete all as specified and directed . |
| 16 | M&L for plain cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as in surface channel or drain or benching in manhole complete all as specified and directed |
| 17 | M&L for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitered/stoppedends etc complete all as specified and directed. |
| 18 | S&F in repair 110mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches/floor or fixed to wall including necessary clamps complete all as specified and directed by Engr-in-Charge. |
| 19 | S&F in repair 75mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches/floor or fixed to wall including necessary clamps complete all as specified and directed by Engr-in-Charge. |
| 20 | M&L for preparation old surfaces of plastered or unplasteredold decorated surfaces by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, washing with water as required and applying two coats of oil bond distemper on walls including cornices, pilasters etc over a coat of 3.00mm thick wall care putty complete all as specified and directed. |
| 21 | Ditto all as per item No. 20 here in above but on ceiling surfaces complete all as specified and directed by Engr-in-Charge. |
| 22 | M&L for preparation of old plaster surfaces finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. Note : The work is required to be carried out upto 25th floor (including terrace of building) from ground floor. The cost of scaffolding shall be deemed to be included in the item. The contractor shall also make necessary safety arrangement for labour. |
| 23 | M&L for preparation of old painted wooden surfaces of any descriptrion over 10cm width or girth and applying one coat of synthetic enamel painting to wooden surface as specified and as directed. |
| 24 | M&L preperation of old painted steel and iron surfaces of any description over 10cm width of girth and applying one coat of synthetic enamel paint (any tint/shade) complete all as specified and directed by Engr-in-Charge. |
| 25 | M&L preparation of new surfaces with 3mm thick wall care putty and applying two coat of oil bond distemper over a coat of primer on walls complete all as specified and directed by Engr-in-Charge. |
| 26 | M&L for preparation of new plaster surfaces finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. Note : The work is required to be carried out upto 25th floor (including terrace of building) from ground floor. The cost of scaffolding shall be deemed to be included in the item. The contractor shall also make necessary safety arrangement for labour. |
| 27 | M&L for Bailing out sludge cleaning/ opening of all blockage under ground sewer line of any depth and size, Cleaning of spot blokage in man hole in any depth, WC of blockage, blockage gully traps, blockage floor trap, blockage CI bend of any type by manual/macanical method. Making good for all servicesable. The Complaint shall be cleared/rectified to the complete satisfaction of Engineer-in-Charge within the same day. Cost of removal of sludge/Solid/liquid materialobtained from sewage lines, manholes, gully trap, floor trap and CI bend out of Residencial area is included in rate of this item. Note :-(i) 01 (One) Sweeper with T&P/ Mechanical equipments shall be provided by Contractor and Monitor/supervised by contractor for provide status of Complaint and maintain the attendence report and record of Complaint/work done. Sweeper shall be provided for 08 hours per day, he should be clear any type of blockage for sewage system on day to day complaint basis by user and will report at 0900 hrs to the AGE B/R,Worli office for complaints and submit completion report by Contractor at 1700 hrs everyday. (The recovery from contractor on account of non complience of complaint within same working day hours of Rs. 1000/- will be recoverd per day)(ii) The Mechanical excavation sewage cleaning machine motor driven compulsory will be brought on the site before commencement and upto complition of work for cleaning blockage, otherwise recovery on account of mechanical excavation sewage machine Rs.1000/- will be recovered per day from contractor. |
| 28 | M&L for cleaning of existing sewage pipe lines 150/200/300mm internal dia at any depth through manholes by removing the manhole covers, by means of hydraulic jet pressure machine or manually as required at site, getting out sludge and liquid materials from connecting manholes and sewer line, flushing with water after cleaning, reinstating the manhole cover to the original position and removing the solids and sludge out of MoD land complete all as specified and directed (Note : Cost of removal of sludge/liquid material from sewage lines and manholes in same line is included in rate of this item) |
| 29 | M&L 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed by Engr-in-Charge. |
| 30 | M&L for Coloured Machine pressed precast polished concrete glossy finish interlocking paver block as in road berm, path and hardstanding any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade withpigments over and including 50mm thick sand cushioning complete all as specified and directed by Engr-in-Charge. |
| 31 | M&L for providing cement concrete 1:2:4 type B-1 for fixing edge of interlocking tiles and rounded or chamfered edges, coping, holdfast, bed blocks complete all as Specified and directed by Engr-in-Charge. |
| 32 | M&L for Cleaning of blocked drain any depth by removing sludge and flush with water and removal of sludge to a distance exc. 1.5Km and n.exc. 5Km out of defence/residential land complete all as specified & directed. |
| 33 | Dismantling wrought iron or mild steel work of any description not otherwise described complete all as specified and directed |
| 34 | S&F Mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framed work and similar works conforming to Fe-290 Gd E-165complete all as specified and directed. |
| 35 | S&F Post or struts in fencing including cutting top to shape as directed drilling holes, notching for wire, etc flat iron fillets(for securing wire mess etc ) including all necessary drilling, bolting or riveting, etc and simillar work conforming to Fe-290 Gde E-165all as specified and directed |
| 36 | S&F Galvanised, 2 strand steel barbed wire 2.24mm dia barbed with 2.00mm dia barbs at 75mm spacings, straining & fixing to any type of standard rails staining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc (each line wire to be measured) as in wire entanglements aprons, barriers, gates, etc. complete all as specified and as directed. |
| 37 | S&F Concertina Coil, galvanised 600mm dia, stretched over barbed wire and Y shaped angle post placed place 2.5m to 3.5m apart over boundary wall upto 3.10m height, 60 spirals per 12 mtr and 3 Nos of clips per spiral and stud tied with GI staple and GI clip to retain horizontal including necessory bolts or GI barbed wire tied to angle iron as per manufacturer\"s instructions complete all as specified and as directed. |
| 38 | M&L for preparing new steel and iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint of any tint over one coat of red oxide primer complete all as specified and directed. |
| 39 | S&F in repairs PVC water storage tank double layer white colour cylindrical, vertical with closed top with threaded cover hoisted and fixed in position tank capacity 1000 Ltr with and including ball valve high pressure of PTMT with epoxy coated Aluminum rod and high density plastic ball screwed for 25mm bore of iron pipe and making connection for inlet and outlet including dismantle of old water tank and removing from site complete all as specified and directed by Engr-in-Charge. |
| 40 | Cleaning of RCCtank 60000 litres capacity after draining out water by using pump sets or any other equipment, cleaning the internal surfaces of walls, ceiling bottom etc with and including by using bleaching powder/liquid chlorine solution and removing the accumulated sludge, dirt, scalesetc from bottom and disposal in low lying area of defence landwhere directed and washout the surfaces with clear water completely including writing in neat letters the relevant information like\"Cleaned on Date\", \"Due Date\" & \"Capacity of tanks\" with black paint on white back ground at visible place complete all as specified and directed. Note (a) Works to be carried out in various floors from ground floor to 22nd floor.. (b) Rate of scaffholding or safety system for labours where ever required are included in the rate.) |
| 41 | Cleaning of RCCtank 45000 litres capacity after draining out water by using pump sets or any other equipment, cleaning the internal surfaces of walls, ceiling bottom etc with and including by using bleaching powder/liquid chlorine solution and removing the accumulated sludge, dirt, scalesetc from bottom and disposal in low lying area of defence landwhere directed and washout the surfaces with clear water completely including writing in neat letters the relevant information like\"Cleaned on Date\", \"Due Date\" & \"Capacity of tanks\" with black paint on white back ground at visible place complete all as specified and directed.Note (a) Works to be carried out in various floors from ground floor to 22nd floor.. (b) Rate of scaffholding or safety system for labours where ever required are included in the rate.) |
| 42 | Cleaning of RCCtank 35000 litres capacity after draining out water by using pump sets or any other equipment, cleaning the internal surfaces of walls, ceiling bottom etc with and including by using bleaching powder/liquid chlorine solution and removing the accumulated sludge, dirt, scalesetc from bottom and disposal in low lying area of defence landwhere directed and washout the surfaces with clear water completely including writing in neat letters the relevant information like\"Cleaned on Date\", \"Due Date\" & \"Capacity of tanks\" with black paint on white back ground at visible place complete all as specified and directed. ... . (Note for Item Srl No 1 to 9 :(a) Works to be carried out in various floors from ground floor to 22nd floor.. (b) Rate of scaffholding or safety system for labours where ever required are included in the rate.) |
| 43 | Cleaning of RCCtank 15000 litres capacity after draining out water by using pump sets or any other equipment, cleaning the internal surfaces of walls, ceiling bottom etc with and including by using bleaching powder/liquid chlorine solution and removing the accumulated sludge, dirt, scalesetc from bottom and disposal in low lying area of defence landwhere directed and washout the surfaces with clear water completely including writing in neat letters the relevant information like\"Cleaned on Date\", \"Due Date\" & \"Capacity of tanks\" with black paint on white back ground at visible place complete all as specified and directed. ...Note (a) Works to be carried out in various floors from ground floor to 22nd floor.. (b) Rate of scaffholding or safety system for labours where ever required are included in the rate.) |
| 44 | Cleaning of RCCUnder ground sump 31000 litres capacity after draining out water by using pump sets or any other equipment, cleaning the internal surfaces of walls, ceiling bottom etc with and including by using bleaching powder/liquid chlorine solution and removing the accumulated sludge, dirt, scalesetc from bottom and disposal in low lying area of defence landwhere directed and washout the surfaces with clear water completely including writing in neat letters the relevant information like\"Cleaned on Date\", \"Due Date\" & \"Capacity of tanks\" with black paint on white back ground at visible place complete all as specified and directed. |
| 45 | Cleaning of RCCUnder ground sump 25000 litres capacity after draining out water by using pump sets or any other equipment, cleaning the internal surfaces of walls, ceiling bottom etc with and including by using bleaching powder/liquid chlorine solution and removing the accumulated sludge, dirt, scalesetc from bottom and disposal in low lying area of defence landwhere directed and washout the surfaces with clear water completely including writing in neat letters the relevant information like\"Cleaned on Date\", \"Due Date\" & \"Capacity of tanks\" with black paint on white back ground at visible place complete all as specified and directed. |
| 46 | Cleaning of RCCUnder ground sump 14000 litres capacity after draining out water by using pump sets or any other equipment, cleaning the internal surfaces of walls, ceiling bottom etc with and including by using bleaching powder/liquid chlorine solution and removing the accumulated sludge, dirt, scalesetc from bottom and disposal in low lying area of defence landwhere directed and washout the surfaces with clear water completely including writing in neat letters the relevant information like\"Cleaned on Date\", \"Due Date\" & \"Capacity of tanks\" with black paint on white back ground at visible place complete all as specified and directed. |
| 47 | Disconnecting of existing rotational moulded polyethylene water storage tanks of cylindrical vertical with closed top type of capacity 500 to 1000 litres from roof/top of buildings at any height and from PCC stagings including disconnecting of existing pipe line, ball valve,air pipe etc , setting aside or lowering for Cleaning of tanks with and including by using bleaching powder/liquid chlorine solution and removing scale and dirt etc from tanks and from mouths of circulating pipes etc including writing information like \"Cleaned on Date\"and \"Due Date\" with black paint on white back ground at visible place, hoisting if required, reconnecting and re-fixing in position complete all as specified and directed. |
| 48 | Disconnecting of existing rotational moulded polyethylene water storage tanks of cylindrical vertical with closed top type of capacity 1000 to 2000 litres from roof/top of buildings at any height and from PCC stagings including disconnecting of existing pipe line, ball valve,air pipe etc , setting aside or lowering for Cleaning of tanks with and including by using bleaching powder/liquid chlorine solution and removing scale and dirt etc from tanks and from mouths of circulating pipes etc including writing information like \"Cleaned on Date\"and \"Due Date\" with black paint on white back ground at visible place, hoisting if required, reconnecting and re-fixing in position complete all as specified and directed. |
| 49 | Removing of old unserviceable water storage PVC tank of any typeafter disconnecting of existing pipe line, ball valve, air pipe etc and supply and fix rotational moulded polyethylene water storage tank 1000 ltr capacity (cylindrical vertical with closed top) of three layerhoisted and fixed in position at any height including reconnetcing of pipe, ball valve, air pipe etc and testing complete all as specified and directed. |
| 50 | Removing of old unserviceable water storage PVC tank of any typeafter disconnecting of existing pipe line, ball valve, air pipe etc and supply and fix rotational moulded polyethylene water storage tank 2000 ltr capacity (cylindrical vertical with closed top) of three layerhoisted and fixed in position at any height including reconnetcing of pipe, ball valve, air pipe etc and testing complete all as specified and directed. |
| 51 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 52 | S&F for steel work in tubler truesses and members medium gradeincluding special shaped washer purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St-240 including dismantling old one complete all as specified and directed |
| 53 | Taking down unseviceable galvalume sheets complete all as specified and directed. |
| 54 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of ancolour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 55 | S & F Pre-painted galvatume aluminum zinc(AZ-150) coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall , fixed with self tapping screwswith bent to a curve (of any radius as per required) complete all as specified and directed by Engr-in-Chrage.(Make : AZ-150 TATA/JSW) |
| 56 | M&L for preparation of new painted Steel surfaces of any descriptrion over 10 cm width or girth and applying two coat of synthetic enamel painting to steel surface over one coat of primer as specified and as directed.(Make:Asian) |
| 57 | Taking down cement plaster of any description, on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as directed. |
| 58 | M & L for rendering 15mm thick on external/ surfaces of brik or concrete wall surfaces in cement motar 1:4mixed with water proofing compound at the rate of 3% by weight of cement and surfaces finished enen and fair without using extra cement all as secified and directe.Note:- WPC shall be mesarued and paid under relevant items. |
| 59 | M&L for Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint on new surface having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |