| 1 | Excavating in trenches manually not exceeding 1.5m wide and not exceeding1.5 mtr in depth/ width for laying under ground cable / foundations and getting out in soft / loose soil all as specified and directed. Note : During excavation no mechanical excavator is permitted at site, contractor will do the excavation through manually. |
| 2 | Returning, filling in incl spreading, levelling, watering and well ramming in layers not exceeding 25cm all as specified and directed. |
| 3 | Removing of surplus excavating material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed. |
| 4 | M&L for sand cushioning for protection of lT under ground cable with screen wash sand and punning to proper reqdcover all as specified and directed. |
| 5 | M & L for brick protection with old size sub class ‘B’brick for PVC underground cable protection in trench with width equal to length of brick laid dry and flat joining each other with gap between adjacent brick not exceeding 10mm over LT under ground cable all as specified and directed. |
| 6 | M&L for cement concrete in foundations, filling and mass concreteType C2 1:3:6, 40mm graded aggregate all as specified and directed. |
| 7 | M&L forPCC as in foundation or any other works type B1 (1:2:4) (20mm graded aggregate) all as specified and directed. Note : Any form work required for PCC works are deemed to be included in this rate. |
| 8 | M&L for rendering 10mm thick in CM 1:6 on fair faces of brick works or concrete surfaces all as specified and directed. |
| 9 | M&L for taking out of old/ unsv cable of any sizes or types for replacement with new one complete all as specified & directed. |
| 10 | M&Lfor relaying heavy duty LT under ground cable of any sizes and types inpipe /trench /cable duct / fixed on wall by proper size shaped GI clamps with nut bolts etc and making good the disturbed surfaces by cement mortar/ paint to match with the existing surface complete all as specified & directed. |
| 11 | M&L for LT Cable fault detection and its rectification by using Cable fault locator machine of span length maximum 2km of cable size 95 to 400 sqmm all as specified and and directed by Engr-in-Charge. Note : Suitable excavation and jointing kit will be measured and paid seperately. |
| 12 | S&L in repair of UG cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor,1100 Volts grade, cross section area incl taking down of size185 sqmm 3.5 core complete all as directed. |
| 13 | All as per above item no.12.00 but size 150 sqmm 3.5 core complete all as directed. |
| 14 | All as per above item no.12.00 but size 95 sqmm 3.5 core complete all as directed. |
| 15 | All as per above item no.12.00 but size 70 sqmm 3.5 core complete all as directed. |
| 16 | All as per above item no.12.00 but size 50 sqmm 3.5 core complete all as directed. |
| 17 | All as per above item no.12.00 but size 25 sqmm 3.5 core complete all as directed. |
| 18 | All as per above item no.12.00 but size 16 sqmm 4 core complete all as directed. |
| 19 | All as per above item no.12.00 but size 10 sqmm 2 core complete all as directed. |
| 20 | M&L for boring under roads or any other specified location by reqd T&P without disturbing the top surface of the road for insertion of GI Pipe of 50 to 100 mm dia etc complete all as specified and directed. |
| 21 | M&L for HDPE Double wall corrugated pipe of size 110/95 mm as per IS: 16098 Part-II-2013 and ISO 21138 & BSEN 13476-1TO 3 laid in trenches/wall for protection cables complete all as specified and directed. |
| 22 | M&L for tubes 50 mm bore light grade galvanized with all fittings laid in trenches/ wall/ pole through MS flat (25X3 mm), nut, bolt & washers [where ever reqd] of proper sizes for protection cables complete all as specified and directed. |
| 23 | All as per above item no. 22.00 here in above but bore size 40 mm complete all as directed. |
| 24 | M&L for fixing the aluminium terminal (Cable Lugs) in cable end (through corrosion inhibiting compound) of cable size 185 sqmm all as specified & directed. Note : Corrosion inhibiting compound which will be used during crimping of terminal shall be measured and paid separately. |
| 25 | All as per above item no-24.00 but for cable size 150 sqmm all as specified and directed. |
| 26 | All as per above item no-24.00 but for cable size 95 sqmm all as specified and directed. |
| 27 | All as per above item no-24.00 but for cable size 70 sqmm all as specified and directed. |
| 28 | All as per above item no-24 but for cable size 50 sqmm all as specified and directed. |
| 29 | All as per above item no-24.00 but for cable size 35 sqmm all as specified and directed. |
| 30 | All as per above item no-24.00 but for cable size 25 sqmm all as specified and directed. |
| 31 | All as per above item no-24.00 but for cable size 16 sqmm all as specified and directed. |
| 32 | All as per above item no-24.00 but for cable size 10 sqmm all as specified and directed. |
| 33 | M&L for triming the tree branchesfalling / touching the HT/LToverhead line in various area ofAF Station Borjhar with skilled labours and cutting tools and disposed the branches to a distance not exceeding 50 mtr length complete all as specified and directed. |
| 34 | M&L for replacement of damage/ corroded hinges with new hinges throgh necessary gas / arc welding works complete on the outdoor feeder pillar box/ LT panel/ or any other works complete all as specified and directed. |
| 35 | M &L for replacement of corroded sheet metal doors of outdoor/ inddor feeder pillar box or LT panel with new CRCA sheet of 2 or 3mm thick incl painting the same with two coats of enamel paint of existing shade over a coat of red oxide primer complete incl treatment of new surfaces complete all as specified and directed. |
| 36 | M&L for writing letter, figures, index arrows etc not exc 30cm in height on LT Panel or any other specified location complete all as specified and directed. |
| 37 | M&L for painting of LT Feeder Pillar Box/ Panel Board or any other plant or equipments by two coat of enamel paint of existing shade after treating old painted surfaces complete al as specified and directed. |
| 38 | M&L for cable jointing kit for 1.1KV grade for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 4 core PVC/ XLPE armoured aluminium conductor cable of size 25 - 50 sqmm complete all as specified and directed. |
| 39 | All as per above item no-38.00 but size 70-150 sqmm all as specified and directed. |
| 40 | All as per above item no-38.00 but size 185-300 sqmm all as specified and directed. |
| 41 | M&L for cable jointing kit for 1.1KV grade for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core PVC/ XLPE armoured aluminium conductor cable of size 70-150 sqmm complete all as specified and directed. |
| 42 | All as per above item no-41.00 but size 185-240 sqmm all as specified and directed. |
| 43 | S&F On-Load Manual Change Over Switch (in sheet steel enclosure) 63 Amps 415 Volts,4 pole after disconnecting all electrical connection incl. taking down old unsv one complete all as specified and directed. Make - L&T/ Siemens/ABB/Schneider. |
| 44 | All as per above item no-43.00 but capacity 100 Amp all as specified and directed. |
| 45 | All as per above item no-43.00 but capacity 160 Amp all as specified and directed. |
| 46 | S&F moulded case circuit breaker 80 - 100 Amps 415 Volts (with thermal magnetic release),4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In after disconnecting all electrical connection incl. taking down old unsv one complete all as specified and directed. Make - L&T/ Siemens/ABB/Schneider. |
| 47 | S&F moulded case circuit breaker 125 - 160 Amps 415 Volts (with thermal magnetic release),4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In after disconnecting all electrical connection incl. taking down old unsv one complete all as specified and directed. Make - L&T/ Siemens/ABB/Schneider. |
| 48 | S&F moulded case circuit breaker 200 - 250 Amps 415 Volts (with thermal magnetic release),4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In after disconnecting all electrical connection incl. taking down old unsv one complete all as specified and directed. Make - L&T/ Siemens/ABB/Schneider. |
| 49 | M&L for fixing the cable junction boxes of size 155 x 210 x 92 mm,with PVC connector 5 way heavy duty for 10 - 16 sq mm, 4.0 /3.5 C, 1100Vcable, IP 66/65, weather proof, outdoor installation type with threaded cable glands, 6A SP & pole mounting brackets etc complete all as specified & directed. |
| 50 | M&L for 2.5 Sqmm, 3 Core Black PVC Insulated Single solid Aluminium conductor round service cable 1100Vfor connection from loop /junction box to street light / security light complete all as specified and directed. |
| 51 | M&L for tubes 15 mm bore light grade galvanized with all fittings laid in trenches/ wall/ pole through MS flat (25X3 mm), nut, bolt & washers [ where ever reqd ] of proper sizes for protection cables complete all as specified and directed. |
| 52 | M&L for Earthing complete with copperearth plate electrode of size 600x600x3.15 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to 20×3mm copper stripas earth lead by means of nuts, bolts, check nuts, washers of galvanized iron as steel,protected by galvanized iron pipe 40mm bore (Medium grade) allas directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel,wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part-I including testing on completion all complete as specified and directed. (copper strip upto 7.5m including testing consider in this item).. |
| 53 | M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw. |
| 54 | M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the Galvanised iron earth wire 4.0mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI medium grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agregates with 40mm thick cover of RCC (1:2:4) reinforeed with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 40x40x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering , perforated at botytom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filled 150 mm thick all around the earth plate test point made out of 40x8mm FIgalvanised with fixing arraangement, funnel wire mesh and earth work in any type of soil returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. |
| 55 | Taking down old unsv/ corrodedLT feeder pillar box/ Busbar Chamber/ DB\"s of any sizes or types (after disconnection of all electrical connections) complete for replacement with new one all as specified and directed by Engr-in-Charge. |
| 56 | Supply, install, testing and commissioning LT cubicle type distribution panel of suitable size, IP-65 type (manufactured from CPRI type tested manufacturer i.e. Indo Asian/ BCH/ L&T/ Havells), Outdoor type made out of 3.15 mm thick CRCAsheet supported on structural frame, angle or channel, factory made, fixed on the ground by galvanised nut & bolts, PCC works (1:2:4 Type B-1) . The LT cubicle type distribution panel should have enamelled danger notice plate of 1.6 mm thick, duly painted with powder coated paint of shade RAL 7032(internally &externally) complete all as specified and directed by Engr-in-Charge.The LT distribution panel must have stainless steel hinges, with special type of heavy duty stainless steel front& back door opening, locking arrangements. The Panel should have provision/accommodation of the following electrical items :- |
| 57 | INDICATING DEVICES:- (a) Three Phase LED Ammeter, Class - 1 with CT (size 96mm x 96mm) Make- L&T/ Schneider/ ABB = 01 No(b) Three Phase LED Voltmeter, Class - 1 (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No(c) LED type panel indicator lamp Make- L&T/ Schneider/ Siemens=03Nos(d) LCD multifunction meter, Make ABB/ Siemens/ Schneider/ L&T-01 No.BUS BAR:- (e) Aluminium bus bar 4 strips (covered with PVC insulated sleeves as per colour code) 600 Amps capacity, including connection etc complete =01 SetINCOMING:- (f) Moulded case circuit breaker 200-250 Amps 415 Volts (Vertically Placed),4 pole 36 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/L&T= 01 No |
| 58 | OUTGOING:-(g) Moulded case circuit breaker 67-100 Amps 415 Volts (Vertically Placed),4 pole 36 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/Legrand/L&T=02No\"s (h) Miniature circuit breaker 63 Amps 230 Volts (Vertically Placed),2 pole 10 KA breaking capacity,C Curve Make - Siemens/ABB/Schneider=01No Note- i) The connection between the MCCB and bus bar should be done by aluminium bar of suitable rating ii) All cables in the feeder pillar box should be properly glanded and thimbled. |
| 59 | Supply and fix in repairs and testing commissioning for indication lampswith showing red, yellow and green in colour of 22.5mm dia to monitor on panel board suitable for 240V AC supply as existing at site,as specified and directed. |
| 60 | Supply and fix in repairs and testing commissioning for digital electronic ammeter of cap as existing rangwith in built selector switch suitable for415V panel flush pattern square type with adopter or as existing including wiring complete all as specified and directed. |
| 61 | Supply and fix in repairs and testing commissioning for digital electronic voltmeter of cap as existing range with in built selector switch suitable for415V panel flush pattern square type with adopter or as per existing including wiring complete all as specified and directed. |
| 62 | M&L for HDPE Double wall corrugated pipe of size 63/50 mm as per IS: 16098 Part-II-2013 and ISO 21138 & BSEN 13476-1TO 3 laid in trenches/wall for protection cables complete all as specified and directed. |
| 63 | S&FDouble wall corrugated pipe coupler for pipe size 63/50 mm all as directed by Engr-in-Charge. |
| 64 | S&FDouble wall corrugated pipe coupler for pipe size 110/95 mm all as directed by Engr-in-Charge. |
| 65 | Supply, install, testing and commissioning of automatic power factor correction (APFC) Panel for 3 Phase, 415 Volt, Delta Connection & 50 Hzs system of capacity 100 KVAR with Super Heavy Duty Cylindrical Capacitor with 8 steps (4x20 KVAr, 1x10 KVAr, 1x5 KVAr, 1x3 KVAr, 1x2 KVAr) with Main incomer MCCB 160A /25 KA complete all as specified and directed by Engr-in-Charge. Make- Havells, Cat. Code- QHXTCB5100X0 or equivalent make in Schneider and Seimens. |
| 66 | Labourfor Maintnence and servicing of DG Sets with AMF Panel of following capacities complete all as specified and as dierected (i) Payment for emergency visit for rectifiying deffect and servicing of DG Set shall be measured ,seperately .(ii) Check the under mentioned Qty of DG setfrom the existing site and preparation of surface by the rust and dust and corrosion by cotton paper /wire brush before repair .(iii) Shifting old u/s spare parts from site to distance not exceed 30 Mtr all as directed.(iv) Cleaning of all dust around the DG Set by using of cleaning materials.(v) Cleaning of all the greasing nozzles /parts by using of emery paper and cotton waste etc. (vi) Carry out the servicing of said DG Set ,Check the oil level of engine oil tupup the same set the tuning of engine if required.(vii) Painting with one coat of existing paint(through spray Gun) should be applied outer side of the engine,writting of Machine No withwhite paint ,Including of RIM of the said DG Set(Trolly mounted) with black paint and inside of the engine with silver paint with marking of existing Sign should be carried out properly and matching with same. |
| 67 | (viii) Minor spare parts like as rubber gasket , pins, key lock &removing ofold engine oil etc shall be replaced under servicing without any extra cost and the proposed rate are excluding consumabale items (Filter, Lube Oil, Coolant,)/ Component repairing (such as FIP/ Self Starter / AC Alternator,s Burning/Battery Charging or Repairing.) shall be measured and paid seperatelyunder respective item of this schedule as supply only and fixing charge shall be deemed included in the unit rate of this of schedule as \"each job\".(ix)The repair/ servicing shall be carried out through authorised representative of ORIGINAL EQUIPMENT MANUFACTURER(OEM) only(x) Provide the visual maintenance and service supports to the AC Alternator.(xi) Work site area shall be cleaned properly. |
| 68 | DG Set of capacity 125 KVA ( with AMF Panel) (Make- Greavs Cotton).(19 Wing Officer Mess, Base Ops, 14 BRD) for emergency visit (DG Set-03 No,s) |
| 69 | DG Set of capacity 25 KVA ( with AMF Panel) (Make-Greaves Cotton).(02 ORR and 20 ORR) for emergency visit(DG Set-02 No,s). |
| 70 | All as per Serial Item No 64.00 here in before but labour for Maintenance & Servicing of DG Sets of following capacities complete all as specified and as dierected for servicing of DG Set. |
| 71 | DG Set of capacity 125 KVA (with AMF Panel) (Make-Greavs Cotton).(19 Wing Officer Mess, Base Ops, 14 BRD) for Servicing visit (DG Set-03 No,s) |
| 72 | DG Set of capacity 25 KVA (with AMF Panel) (Make-Greavs Cotton).(02 ORR and 20 ORR) for DG Set-02 No\"s) |
| 73 | Supply the following spare parts of DG Set of capacity 03x 125 KVA.required for servicing of DG Set. |
| 74 | FILTER kit ( Oil Filter, Diesel filter, Turbo filter and Turbo filter O Ring Kit |
| 75 | L. O Filter |
| 76 | V Belt |
| 77 | AirFilter primery |
| 78 | Air Filter Secondary |
| 79 | Rotating rectified assembly. |
| 80 | Automatic voltage regulator |
| 81 | Water Pump Assy |
| 82 | Air cleaner hose pipe with clamp. |
| 83 | Radiator hose pipe with clamp. |
| 84 | Safety control valve. |
| 85 | Battery charger for automatic panel. |
| 86 | Supplythe following spare parts of DG Set of capacity 2x25 KVA.required for servicing of DG Set.=04 No,s |
| 87 | FILTER kit ( Oil Filter, Diesel filter, Turbo filter and Turbo filter O Ring Kit |
| 88 | L. O Filter |
| 89 | V Belt |
| 90 | AirFilter primery |
| 91 | Air Filter Secondary |
| 92 | Rotating rectified assembly. |
| 93 | Automatic voltage regulator |
| 94 | Water Pump Assy |
| 95 | Air cleaner hose pipe with clamp. |
| 96 | Radiator hose pipe with clamp. |
| 97 | Safety control valve. |
| 98 | Battery charger for automatic panel. |
| 99 | All as per Serial Item No 64.00 here in before for Maintenance and emergency visitofDG Sets of following capacities complete all as specified and as dierected for rectified of DG Set. |
| 100 | DG Set of capacity 125 KVA ( with AMF Panel) (Make- Mahindra).(19 Wing 59 Sqdn) for emergency visit (DG Set-1 No,s) |
| 101 | DG Set of capacity 63 KVA ( with AMF Panel) (Make-Mahidra).( Complain Cell 19 wing) for emergency visit (DG Set-01 No,s). |
| 102 | All as per Serial Item No 64.00 here in before for Maintenance & Servicing of DG Sets of following capacities complete all as specified and as dierected for servicing of DG Set. |
| 103 | DG Set of capacity 125 KVA ( with AMF Panel) (Make-Mahidra).(19 Wing Officer Mess, Base Ops,14 BRD) for Servicng visit (DG Set-01 No,s) |
| 104 | DG Set of capacity 63 KVA ( with AMF Panel) (Make-Mahidra)).(Complain Cell 19 wing) foDG Set-01 No\"s) |
| 105 | Supplythe following spare parts of DG Set of capacity 1x125 KVA(make -Mahindra).required for servicing of DG Set |
| 106 | FILTER kit ( Oil Filter, Deisel filter, Turbo filter and Turbo filter O Ring Kit |
| 107 | L. O Filter |
| 108 | V Belt |
| 109 | AirFilter primery |
| 110 | Air Filter Secondry |
| 111 | Rotating rectified assembly. |
| 112 | Automatic voltage regulator |
| 113 | Water Pump Assy |
| 114 | Air cleaner hose pipe with clamp. |
| 115 | Radiator hose pipe with clamp. |
| 116 | Safety control valve. |
| 117 | Battery charger for automatic panel. |
| 118 | Supply and fixing ,repairingthe following spare parts of DG Set of capacity 63 KVA (Make-Mahindra). |
| 119 | Fuel Filter Secondary |
| 120 | Fuel Filter Primery |
| 121 | L. O Filter |
| 122 | V Belt |
| 123 | Air Filter |
| 124 | R R Assly |
| 125 | Automatic voltage regulator |
| 126 | Water Pump Assy |
| 127 | Air cleaner hose pipe with clamp. |
| 128 | Radiator hose pipe with clamp. |
| 129 | Safety control valve. |
| 130 | Battery charger for automatic panel. |
| 131 | All as per Item No (1) ,above for Maintenance and emergency visitofDG Sets of following capacities complete all as specified and as dierected for rectified of DG Set. |
| 132 | DG Set of capacity 62.5 KVA ( with AMF Panel) (Make- Ashok Layland).(Base opsfor IT sec) for emergency visit (DG Set-1 No,s) |
| 133 | All as per Item No (1) ,above ,Labour for Maintenance & Servicing of DG Sets of following capacities complete all as specified and as dierected for servicing of DG Set. |
| 134 | DG Set of capacity 62.5 KVA (with AMF Panel)(Make- Ashok Layland).(Base opsfor IT sec) for Servicng visit (DG Set-01 No,s) |
| 135 | Supply the following spare parts of DG Set of capacity 1x 62.5/63 KVA.required for servicing of DG Set |
| 136 | Oil Filter F7A05000 |
| 137 | Fuel Stainer |
| 138 | Fan belt X0301750 |
| 139 | All as per Serial Item No 64.00 here in before for Maintenance and emergency visitofDG Sets of following capacities complete all as specified and as dierected for rectified of DG Set. |
| 140 | DG Set of capacity 160 KVA ( with AMF Panel) (Make- Ashok Layland).(Domestic Complaint cell) for emergency visit (DG Set-1 No,s) |
| 141 | All as per Serial Item No 64.00 here in before but labour for Maintenance & Servicing of DG Sets of following capacities complete all as specified and as dierected for servicing of DG Set. |
| 142 | DG Set of capacity 160 KVA ( with AMF Panel) (Make- Ashok Layland).(Domestic Complaint cell) for Servicng visit (DG Set-01 No,s) |
| 143 | Supply the following spare parts of DG Set of capacity 1x 160 KVA.required for servicing of DG Set |
| 144 | LO Filter |
| 145 | Diesel Filter |
| 146 | Air Filter |
| 147 | Fuel Stainer |
| 148 | Fan belt X0301750 |
| 149 | All as per Serial Item No 64.00 here in before but Maintenance and emergency visitofDG Sets of following capacities complete all as specified and as dierected for rectified of DG Set. |
| 150 | DG Set of capacity45 KVA ( with AMF Panel) (Make- Jakson(Cumins).(C Cell, Education Sec 19 wing) for emergency visit (DG Set-1 No,s) |
| 151 | DG Set of capacity62.5KVA ( with AMF Panel) (Make- Jakson (Cumins).(C CellCDUpadhayay Block 19 Wing 59 Sqdn) for emergency visit (DG Set-1 No,s) |
| 152 | All as per Serial Item No 64.00 here in before but labour for Maintenance & Servicing of DG Sets of following capacities complete all as specified and as dierected for servicing of DG Set. |
| 153 | DG Set of capacity45 KVA (with AMF Panel) (Make- Jakson(Cumins).(C Cell, Education Sec 19 wing)) for Servicng visit (DG Set-01 No,s) |
| 154 | DG Set of capacity62.5KVA (with AMF Panel) (Make- Jakson(Cumins).(C CellCDUpadhayay Block 19 Wing) for Servicng visit (DG Set-01 No,s) |
| 155 | Supply the following spare parts of DG Set of capacity 1x 62.5 & 1x45KVA.required for servicing of DG Set |
| 156 | Lube Oil Filter |
| 157 | FILTER kit (Oil Filter, Diesel filter, Turbo filter and Turbo filter O Ring Kit |
| 158 | V Belt |
| 159 | Air Filter (Inner & Outer) |
| 160 | R R Assy |
| 161 | AVR |
| 162 | Water Pump |
| 163 | Supply and fixing for engine stop solined switch for DG set of capacity 45/25 KVA as per existing makefor DG Set - Greavs Cotton/Jackson |
| 164 | Supply and fixing for engine stop solined switch for DG set of capacity 125/63 KVA as per existing make for DG Set -Greavs Cotton/ Mahindra/ Ashok Layland/ Jackson |
| 165 | Supply only engine oil 20W 40 for diesel engine driven generator in 50 ltrs container . Make - KOEL (Type- Premium)/ Eqvt to Castrol/ Indian Oil |
| 166 | Supply only coolant for diesel engine driven generator in 26 ltrs container . Make - KOEL (Type- K-Cool)/ Eqvt. |
| 167 | Supply only distilled water for diesel engine driven generator. |
| 168 | Supply and fixing in repair for battery of Capacity 12V 80 AH Complete all as specified and as directed. |
| 169 | Supply and fixing in repair for battery of Capacity 12V 120 AH Complete all as specified and as directed. |
| 170 | Supply and fixing in repair for battery of Capacity 12V 130 AH Complete all as specified and as directed. |
| 171 | Supply and fixing in repair for battery of Capacity 12V 150 AH Complete all as specified and as directed. |
| 172 | Supply and fixing in repair for battery of Capacity 12V 180 AH Complete all as specified and as directed. |
| 173 | S & F for battery lead with terminal cable of copper conductor size 19 SWG and 90 CM long as in repair complete all as specified and as directed by Engineer -in- Charge |
| 174 | Suplly and fixing for Alternator fly wheel ring gear for DG set capacity 125/63 as per existing make . |
| 175 | Supply only selector switch two way for 125/100 KVA DG AMF Panel Make : AE/L&T/FTC |
| 176 | Supply only power contactor 4 pole for 125/63/45/25 KVA DGSet (any Make fo DG set) AMF Panel Make:- L&T /Suchnieder/Seimens |
| 177 | Supply and fixing for turbo charger repair kit for DG set of capacity 125/63 KVA as per existing makefor DG Set - Greaves Cotton / Mahindra / Jakson / Ashok Layland. |
| 178 | Supply and fixing for turbo charger repair kit for DG set of capacity 45/25 KVA as per existing makefor DG Set - Jakson /Greaves Cotton. |
| 179 | Taking out /Removing of u/s Self starter assembly complete for repairing to workshop replacing armature ,winding withsize copper enamelled wire ,repair /servicing of commutator, replacing of corbon brush, complete servicing, greasingincluding re-assembling ,re-fixing (testing, commisining complete aii as specified and directed including replacing of small worm out parts) ofDG set of capacitty 125/63 KVA Make -Greaves Cotton /Mahindra/Jakson/Ashok Layland) |
| 180 | Taking out /Removing of u/s Self starter assembly complete for repairing to workshop replacing armature, winding withsize copper enamelled wire, repair / servicing of commutator, replacing of corbon brush, complete servicing, greasingincluding re-assembling, re-fixing (testing, commisining complete aii as specified and directed including replacing of small worm out parts) ofDG set of capacitty 45/25 KVA Make : Greaves Cotton/Jakson) |
| 181 | Taking out /Removing of u/s Dynamo assembly complete for repairing to workshop rewinding of armature with same size copper enamelledwire complete servicing of commutator, replacing roter complete ,re-assembliing testing commissioning complete all directed. ofDG set of capacitty 125/63 KVA Make -Greaves Cotton/Mahindra /Jakson/Ashok Layland. |
| 182 | Taking out /Removing of u/s Dynamo assembly complete for repairing to workshop rewinding of armature with same size copper enamelledwire complete servicing of commutator, replacing roter complete, re-assembliing testing commissioning complete all directed. of DG set of capacitty 45/25 KVA Make -Jakson/Greaves Cotton. |
| 183 | Supply & Installation PCB controller of AMF panel of DG Set as per existing make & type incl taking down old unsv one all as specified and directed. |
| 184 | M&L for repairing of FIP for 25 to 45 KVA DG Set through FIP repair kit, incl replacement of valve and element (where ever reqd) and calibration all as specified and directed. Make of DG Set- Greaves Cotton/ Mahindra/ Cummins/ Jakson. |
| 185 | M&L for repairing of FIP for 62.5/ 63/ 100/ 125 KVA DG Set through FIP repair kit, incl replacement of valve and element (where ever reqd) and calibration all as specified and directed. Make of DG Set-Mahindra/ Cummins/Greaves Cotton/Jakson/Ashok Layland |
| 186 | S&F Self Starter Complete set 12 V for 25-45 KVA Kirloskar/ Kirloskar Bliss/Mahindra/ Cummins make Gen Set incl replacement of cable of suitable size complete all as specified and directed. |
| 187 | S&F Self Starter Complete set 12 V for 63-125 KVA Kirloskar/ Kirloskar Bliss/Mahindra/ Cummins make Gen Set incl replacement of cable of suitable size complete all as specified and directed. |
| 188 | M&L for dismantling the radiator assembly incl hose/ pipe/ clamps etc after shut off the diesel genrator set of 25 to 45 KVA capacity and taking out the same at workshop and cleaning/ servicing the sameby following process:-a) Spray the hot water or steam to remove dirt, dust, or even insects which are accumulated in the radiator.b) Descaling the radiator by using rust removing acid solution and water or mixture of water, caustic soda, and kerosene as per the recommendation of the manufacturer of the generator setc) Transportation to the installation, reconnection, testing & checking etc completeNote : Repairing such as brazing or soldering, replacement of tank, hoses pipe, clamps etc are deemed to be included in the quoated rate. |
| 189 | M&L for dismantling the radiator assembly incl hose/ pipe/ clamps etc after shut off the diesel genrator set of 63 to 125 KVA capacity and taking out the same at workshop and cleaning/ servicing the sameby following process:-a) Spray the hot water or steam to remove dirt, dust, or even insects which are accumulated in the radiator.b) Descaling the radiator by using rust removing acid solution and water or mixture of water, caustic soda, and kerosene as per the recommendation of the manufacturer of the generator setc) Transportation to the installation, reconnection, testing & checking etc completeNote : Rrepairing such as brazing or soldering, replacementoftank , hoses pipe, clamps etc are deemed to be included in the quoated rate. |
| 190 | Supply and fixing for turbo charger repair kit for DG set of capacity 125/63 KVA as per existing make and cat No (For any Make of DG Set- KOEL/Kirloskar Bliss). |
| 191 | Supply and fixing for turbo charger repair kit for DG set of capacity 45/25 KVA as per existing make and cat No(For any Make of DG Set- Kirloskar/ Kirloskar Bliss/Mahindra/ Cummin). |
| 192 | S& F of Flexible pipe for fuel pump to PT pump with benjo nut, bolt & washer for DG Set of capacityupto 125 KVA |
| 193 | S & F of Flexible pipe for disel tank to filter with benjo nut, bolt & washer for DG Set of capacityupto 125 KVA |
| 194 | Labour for Dismantling/strip opening of 45 KVA DG Set Make-Kirloskar Bliss (at Mountain Shadow P H No-02) for repairing/ovehauliing complete, re-fixing /reassembling complete including testing commissioning all as directed.Note : (a) The above repair/overhaul shall be carried out through authrised representative of OEM.(b) The spare parts required for repairing /overhaulling shall be measured and paid under relevent items. |
| 195 | All as per Serial Item No 64.00 here in before but labour for Maintenance & Servicing of DG Sets of following capacities complete all as specified and as dierected for servicing of DG Set. |
| 196 | DG Set of capacity 45 KVA DG Set Make Kirloskar Bliss (DG Set-01 No,s) for emergency visit. |
| 197 | All as per Serial Item No 64.00 here in before but labour for Maintenance & Servicing of DG Sets of following capacities complete all as specified and as dierected for servicing of DG Set. |
| 198 | DG Set of capacity 45 KVA DG Set Make Kirloskar Blissfor Servicng visit (DG Set-01 No,s) |
| 199 | Supply the following spare parts of DG Set of capacity1x45KVA. required for servicing of DG Set |
| 200 | Lube Oil Filter |
| 201 | FILTER kit (Oil Filter ,Diesel filter, Turbo filter and Turbo filter O Ring Kit |
| 202 | V Belt |
| 203 | Air Filter (inner & Outer) |
| 204 | R R Assy |
| 205 | AVR |
| 206 | Water Pump |