| 1 | M&L for Servicingto Window type Air conditioner of various capacities of different makes (1 TR to 2 TR) by cleaning with Jet water pressure pump forcondensing coil and filter with mild cleaner, checking gas pressure/ leakage & rectification of minor faults if any all as specified & directed by Engineer-in- Charge. |
| 2 | M&L for Servicingto Split type Air conditioner (Indoor & outdoor units) of various capacities of different makes (1TR to 2TR) by cleaning with Jet water pressure pump for condensing coil and filter with mild cleanser, checking gas pressure/ leakage & rectification of minor faults if any all as specified & directed by Engineer-in- Charge. |
| 3 | M&L for Servicingto Split / Cassete/ Tower TypeAir conditioner of various capacities of different makes (3 TR) by cleaning with Jet water Pump for condensing coil and filter with mild cleanser, checking gas pressure/ leakage & rectification of minor faults if any all as specified & directed by Engineer-in- Charge. Note : (i) Sl No 1 2 and 3 shall be cleaned with water and Jet water pump and take the signature from the user to be obtained before claiming RAR & to be submit to office for records.(ii) If gas pressur found less than permissible pressur the contractor should insure to fill the gas and maintain the gas presuure as per requirement for achiveining desired cooling level.(iii) If required battery or any other minor parts for remote to be replaced and cost for the same shall be included in the rate quoted. |
| 4 | S&F indoor unit of split type AC1.5 Ton capacity after disconnection of old unserviceable indoor unit of Split AC (1.5 TR cap ) including soldering/ brazing of liquid /gas pipeline, cleaning the system arresting the leakage, vacuumization, initial charging of oil & refrigerant gas what ever quantity requiredincluding installation, testing & commissioning etc.complete all as specified and directed by Engineer-in-Charge. Make- LG/ Voltas (Existing make are to be replaced with new one) |
| 5 | S&F indoor unit of split type AC2.0 Ton capacity after disconnection of old unserviceable indoor unit of Split AC (2.0 TR cap ) including soldering/ brazing of liquid /gas pipeline, cleaning the system arresting the leakage, vacuumization, initial charging of oil & refrigerant gas what ever quantity requiredincluding installation, testing & commissioning etc.complete all as specified and as directed Engineer-in-Charge. Make- LG/ Voltas (Existing make are to be replaced with new one) |
| 6 | Disconnecting and removing unserviceable sealed compressor of Split AC (1.5 TR cap Inverter type) and replaced withnew hermatically sealed compressor of existing make &modelincluding soldering/ brazing of liquid /gas pipeline, cleaning the system arresting the leakage, vacuumization, initial charging of oil & refrigerant gas what ever quantity requiredincluding installation, testing & commissioning etc.complete all as specified and directed by Engineer-in-Charge. |
| 7 | Disconnecting and removing unserviceable sealed compressor of Split AC (2.0 TR cap Inverter type) and replaced withnew hermatically sealed compressor of existing make &modelincluding soldering/ brazing of liquid /gas pipeline, cleaning the system arresting the leakage, vacuumization, initial charging of oil & refrigerant gas what ever quantity requiredincluding installation, testing & commissioning etc.complete all as specified and directed by Engineer-in-Charge. |
| 8 | Disconnecting and removing unserviceable sealed compressor of Split AC (1.5 TR cap ) and replaced withnew hermatically sealed compressor of existing make &modelincluding soldering/ brazing of liquid /gas pipeline, cleaning the system arresting the leakage, vacuumization, initial charging of oil & refrigerant gas what ever quantity requiredincluding installation, testing & commissioning etc.complete all as specified and directed by Engineer-in-Charge. |
| 9 | Disconnectingand removing unserviceable sealed compressor of Split AC (2.0 TR cap ) and replaced withnew hermatically sealed compressor of existing make &modelincluding soldering/ brazing of liquid /gas pipeline, cleaning the system arresting the leakage, vacuumization, initial charging of oil & refrigerant gas what ever quantity requiredincluding installation, testing & commissioning etc.complete all as specified and directed by Engineer-in-Charge. |
| 10 | S&F PCB Set for inverter type (indoor unit+ Outdoor) Split AC 1.5/ 2.0/ 3.0 TR capacity complete all asspecified and directed by Engr-in Charge.Make- LG/ Voltas/ Blue Star. Note:- Contractor should supply PCB for the OEM |
| 11 | S&F PCB set(Indoor unit +oudoor unit) for Split AC 1.5/ 2.0/ 3.0 TR capacity complete all asspecified and directed by Engr-in Charge. Make- LG/ Voltas/ Blue Star. Note:- Contractor should supply PCB for the OEM |
| 12 | S&F PCB set for inverter AC Casset type (Indoor unit +oudoor unit) Split AC 1.5/ 2.0/ 3.0 TR capacity complete all asspecified and directed by Engr-in Charge. Make- LG/ Voltas/ Blue Star. Note:- Contractor should supply PCB for the OEM |
| 13 | M&L replacement to unserviceable copper capillary tube withnew of appropriate size including soldering/ brazing & leak testingfor window /split type ACcomplete all as specified and directed by Engineer-in-Charge. |
| 14 | M&L for dismantling of Any type PCBfrom window/split type AC and repair the same with expert techenition including refixing the same afer repair at the existing place etc complete all as specified and directed by Engineer-in-charge. Engineer-in-charge. |
| 15 | M&L for dismantling toBlower fan motor from window/ split type AC and rewinding tosame with super enameled copper wire of appropriate gauge including heat, varnishing & replacementof worn out bearing or bush & capacitor etc complete all as specified and directed by Engineer-in-charge. |
| 16 | M&L for replacement of unserviceable starting capacitor 100/120 mfd with new one for window/ split type AC complete all as specified and directed by Engineer-in-Charge.Make : UNIVERSAL /SARDA / existing make of Window/Split AC. |
| 17 | All as per above item No. 16.00here-in-beforebut80/ 100 mfd. Make : UNIVERSAL /SARDA / existing make of Window/ Split AC. |
| 18 | M&L for replacement to unserviceable dual run capacitor 55 mfd with new one for window/ split type AC complete all as specified and directed by Engineer-in-Charge.Make : UNIVERSAL /SARDA /existing make of Window/ Split AC. |
| 19 | M&L for replacement tounserviceable dual run capacitor50+4 mfd with new onefor window/ split type AC complete all as specified and directed by Engineer-in-Charge. |
| 20 | M&L for replacement to unserviceable dual run capacitor66+6 mfd with new one for window/ split type AC complete all as specified and directed by Engineer-in-Charge. |
| 21 | M&L for replacement to unserviceable thermostat switchwith new suitable for one window/ split type AC complete all as specified and directed by Engineer-in-Charge. |
| 22 | M&L for replacement to unserviceable relay of single phase AC supply with new one suitable forwindow/ split type AC complete all as specified and directed by Engineer-in-Charge. |
| 23 | M&L for replacement to unserviceable over load protector single phase AC with new one suitable forwindow/ split type AC complete all as specified and directed by Engineer-in-Charge. |
| 24 | M&L for replacement tounserviceable air filter with new one suitable for window/ split type AC complete all as specified and directed by Engineer-in-Charge. |
| 25 | M&L for replacement tounserviceablefan motor with blades with new fan motor with blades suitable forwindow/ split type AC complete all as specified and directed by Engineer-in-Charge. |
| 26 | M&L for replacement tounserviceablefront grill with new front grill suitable forwindow AC as per existing size & shape complete all specified and directed by Engineer-in-Charge. |
| 27 | M&L for replacement to unserviceable panel selector switch with new selector switch suitable forwindow AC complete all as specified and directed by Engineer-in-Charge. |
| 28 | Taking outtoreplacementto worn out & corroded portion of AC\"s body/ base with new M.Ssheet 1.25 mm thick by cutting, bending, welding, machining etc to bring back the original shape including painting with synthetic enamel paint through spraygun machine over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge |
| 29 | S&F replacement to unserviceable contactor accessories single phase AC with new contactor accessories suitable forwindow/ split type AC complete all as specified and directed by Engineer-in-Charge. Make : Siemens or equivallent make approved by MES |
| 30 | S&F replacement to unserviceable electronic control panel boardwith new control panel suitable for 1.5/ 2.0 TR split type AC complete all as specified and directed by Engineer-in-Charge. |
| 31 | S&F replacement to unserviceable display circuitsuitable for 230 volt, ACwith new display circuit suitable for 1.5/ 2.0 TR split type AC complete all as specified and directed by Engineer-in-Charge. |
| 32 | S&F replacement tounserviceable cordless remote with new remote suitable for machine of 1.5/ 2.0 TR split type AC complete all as specified and directed by Engineer-in-Charge. |
| 33 | Material & Labour for filling gas for 1.5 TR capacityWindow/ Split type AC with required quantity refrigerant gas after necessary vacuumization, sealing and leak testing etc. complete all as specified and directed by Engineer-in-Charge. Note: Refrigerant Gas will be issued under Schedule \"B\" Stores |
| 34 | Material & Labour for filling gas for 2.0 TR capacityWindow/ Split type AC with required quantity refrigerant gas after necessary vacuumization, sealing and leak testing etc. complete all as specified and directed by Engineer-in-Charge. Note:- Refrigerant Gas will be issued under Schedule \"B\" Stores |
| 35 | M&L for replacement to unserviceable capacitor 36 mfd with new capacitor suitable for rotary type compressor of window/ split type AC complete all as specified and directed by Engineer-in-Charge. |
| 36 | M&L for replacement to unserviceable capacitor 45 mfd with new capacitor suitable for rotary type compressor of window /split type AC complete all as specified and directed by Engineer-in-Charge. |
| 37 | M&l for dismantling, shifting , installation & testingof Window/ Splittype AC 1.5/ 2.0 TR from one place to another place (with in radius of 2 km) all as specified and directed by Engr-in-Charge. |
| 38 | S&F new copper pipe of dia 5/8 inch insulated by nitrile rubber for suction line including soldering/ brazing of pipe, cleaning the system arresting the leakage (if any), vacuumization, etc. complete all as specified and directed by Engineer-in-Charge. |
| 39 | S&F new copper pipe of dia 1/4 inch insulated by nitrile rubber for suction line including soldering/ brazing of pipe, cleaning the system arresting the leakage (if any), vacuumization etc. complete all as specified and directed by Engineer-in-Charge. |
| 40 | M& Lfor insulation for copper pipes(liquid and gas line) as per existing type rubber insulating materials suitable for split AC complete as directed by Engr-in Charge. |
| 41 | M&L for replacement of old corroded outdoor type mounting bracket with new heavy duty outdoor type mounting bracket incl fixing the bracket on the wall through fastener bolt etc complete all as specified & directed by Engr-in-Charge. |
| 42 | S&F outdoor unit of split type AC of 1.5 Ton capacity after disconnection of old unserviceable outdoor unit of Split AC (1.5 TR cap ) including soldering/ brazing of liquid /gas pipeline, cleaning the system arresting the leakage, vacuumization, initial charging of oil & refrigerant gas what ever quantity requiredincluding installation, testing & commissioning etc.complete all as specified and directed by Engineer-in-Charge. |
| 43 | S&F outdoor unit of split type AC of 2.0 Ton capacity after disconnection of old unserviceable outdoor unit of Split AC (2.0 TR cap ) including soldering/ brazing of liquid /gas pipeline, cleaning the system arresting the leakage, vacuumization, initial charging of oil & refrigerant gas what ever quantity requiredincluding installation, testing & commissioning etc.complete all as specified and directed by Engineer-in-Charge. Make- LG/ Voltas (Existing make are to be replaced with new one)Note : Complaint of Window/ Split AC shall be attended within two hours after intimation to the contractor through SMS/ Whats app/ Telephone by JE E/M or Engr-in-Charge, otherwise an amount of Rs 100/ Hr (beyond two hours)will be deducted from his billing amount and that complain must be rectified within 24 Hours after intimation through SMS/ Whatsapp/ Telephone, other wise an amount of Rs 200/ Hr (beyond 24 Hours) will be deducted from his billing amount. |
| 44 | M&L for Repair and Annual comprehensivemaintenance of moudular type Variable Refrigerant Flow (Samsung make) equipped with inverter, compressors, acryl precoated heat exchanger, low noise Condenser fan, auto check function for connection error, auto address setting with any capacity Modules and any location with and Including replacement of all thermocol foams insulating materials and any type of packing material, PVC drain pipe connections and any item, R-410 Refrigrant required for replacement like as copper tubling gasket pumps, fan motor etc through authorised service providerfor the complete plant by servicing/replacing any type spare parts as and when required to outdoor, indoor unitsduring the period of contract and in one year liability period complete all directed by Engineer-in- Charge For Base Ops-(22x3 outdoor Unit with 15 Indoor Unit)Note : Outdoor unit each of 22HP with proportionate no of indoor units shall be maintained & HP shall be measured accordingly. |
| 45 | All as per item No 44.00 here in before but for 746 SU-(8.75 HPx2 uotdoor Unit with09 No Indoor Unit).Note : Outdoor unit each of 8.75HP with proportionate no of indoor units shall be maintained & HP shall be measured accordingly. |
| 46 | All as per item No 44.00 here in before but for AF Net Signal Sec(4HPx2 out door Unit with 04 indoor Unit)Note : Outdoor unit each of 4HP with proportionate no of indoor units shall be maintained & HP shall be measured accordingly. |
| 47 | All as per item No 44.00 here in before but for CD Upadhyay Block-(24HPx1 outdoor Unit with 04 indoor Unit).Note : Outdoor unit each of 24HP with proportionate no of indoor units shall be maintained & HP shall be measured accordingly. |
| 48 | All as per item No 44.00 here in before but for Satcom Bldg(14 BRD-(22HPx1outdoor unit with 09 Nos of indoor unit).Note : Outdoor unit each of 22HP with proportionate no of indoor units shall be maintained & HP shall be measured accordingly. |
| 49 | All as per item No 44.00 here in before but for TUPG LAB Bldg(14 BRD-(18 HPx4outdoor unit with 20 Nos of indoor unit).Note : Outdoor unit each of 18HP with proportionate no of indoor units shall be maintained & HP shall be measured accordingly. |
| 50 | M&L for Repair and Annual comprehensivemaintenance of modular type Variable Refrigerant Flow (Carrier make) system 12x4HP equipped with invertor, compressors, acryl precoated heat exchanger, low noise Condenser fan, auto check function for connection error, auto address setting with any capacity Modules and any location Including replacement of all thermocol foams insulating materials and any type of packing material, PVC drain pipe connections and any item required for replacement like as copper tubing gasket pumps, fan motor etc throughauthorisedservice agent of manufacturer for the complete plant by servicing/replacing any type spare parts as and when required to outdoor, indoor units including compressor, condensor, PCBs, valves, fan motors, piping, insulation refrigerant during the period of contract and in one year liability period complete all directed by Engineer-in- Charge.(i) Officer Mess- 12 HPx4 outdoor unit with 12 indoor unit.Note : Outdoor unit each of 12HP with proportionate no of indoor units shall be maintained & HP shall be measured accordingly. |
| 51 | Note for Item No 44.00 to 50.00 :(i) Technician of OEM will visit site as and when required or directed by Engr-in-charge within 2 hour and to be completed in12 hoursof complaint registered other wise the penalty should recoverd @ Rs 500/Hrs and same shall be diducted from the contractor. (ii) one year guarantee certificate to be submitted by the contractor before completion of work(iii) The cost of thermocol foams and any type of packing material, PVC drain pipe R-410 Refrigerant etc shall be deemed tobe included in the unit rate of this item. Nothing extra shall beentertained on this account(iv) Spare parts like as Compressor, PCBs, Harmony, motor shall be measured &paid as Supply onlyseperatly under respective item No. 7 to 28 of this schedule. Fixing charges of these spare parts shall be deemed to be included in the unit rate of this item without entertaining extra cost on this account. |
| 52 | Supply and fix new Fan PCB Main assembly complete all as directed by Engr-in Charge.Make : Samsung Cat No.DB92-03341A or Equivalent MES approved make. |
| 53 | Supply and fix new SUB (HUB) PCB Main assembly complete all as directed by Engr-in Charge.Make : Samsung Cat No.DB92-03340A/42A or Equivalent MES approved make. |
| 54 | Supply and fix new Inverter PCB Main assembly complete all as directed by Engr-in Charge.Make-Samsung Cat No.DB92-03526A or Equivalent MES approved make. |
| 55 | Supply and fix new Main Display PCB Main assembly complete all as directed by Engr-in Charge.Make : Samsung Cat No.DB92-03340A or Equivalent MES approved make. |
| 56 | Supply only new EMI PCB Main assembly complete all as directed by Engr-in Charge.Make : Samsung Cat No.DB93-13529A or Equivalent MES approved make. |
| 57 | Supply only new Drain pump complete all as directed by Engr-in Charge.Make : Samsung/ Carrier or Equivalent MES approved make. |
| 58 | Supply only new Thermistor complete all as directed by Engr-in Charge.Make- Samsung/CarrierEquivalent MES approved make. |
| 59 | Supply only new Coil Harmonic complete all as directed by Engr-in Charge.Make-Samsung Cat No.DB27-00094A or Equivalent MES approved make. |
| 60 | Supply only new Motor complete all as directed by Engr-in Charge.Make-Samsung Cat No.DB31-00578A or Equivalent MES approved make. |
| 61 | Supply only new fan motor PCB Main assemblysuitable forAC Plant complete all as directed by Engr-in Charge. Make-Carrier /Samsung (DB93-13184595 or Equivalent MES approved make. |
| 62 | Supply only new float switch suitable for 24 HP VRF AC Plant complete all as directed by Engr-in Charge. Make-Carrier/samsung or Equivalent MES approved make. |
| 63 | Supply only new DC Inverter PCB Main assembly complete all as directed by Engr-in Charge.Make- Carrier or Equivalent MES approved make. |
| 64 | Supply only new main Display PCB Main assembly complete all as directed by Engr-in Charge.Make- Carrier or Equivalent MES approved make. |
| 65 | Supply only new Indoor unit PCB for VRF AC Plantcomplete all as directed by Engr-in Charge.Make- Carrier/Samsung or Equivalent MES approved make. |
| 66 | Supply only new Indoor Unit Motor for VRF AC Plant complete all as directed by Engr-in Charge.Make- Carrier/Samsung or Equivalent MES approved make. |
| 67 | Supply only new Expantion Valve suitable forAC Plant complete all as directed by Engr-in Charge. Make-Carrier /Samsung (DB93-13529 or Equivalent MES approved make. |
| 68 | Supply only new Inter Cooler suitable forAC Plant complete all as directed by Engr-in Charge. Make-Carrier /Samsung (DB92-04466A) or Equivalent MES approved make. |
| 69 | Supply only new Comman Assenbly One By Two suitable forAC Plant complete all as directed by Engr-in Charge. Make-Carrier /Samsung (DB92-03340A) or Equivalent MES approved make. |
| 70 | Supply only new Tube Injector suitable forAC Plant complete all as directed by Engr-in Charge. Make-Carrier /Samsung (DB93-13529A) or Equivalent MES approved make. |
| 71 | Supply only new Liquid Filter One By Two suitable forAC Plant complete all as directed by Engr-in Charge. Make-Carrier /Samsung (SB93-1452029G) or Equivalent MES approved make. |
| 72 | Supply only new VRF Wall suitable forAC Plant complete all as directed by Engr-in Charge. Make-Carrier /Samsung (DB93-1548525V) or Equivalent MES approved make. |
| 73 | Disconnecting to unserviceable sealed compressor of suitable for 24 HP VRF AC plant and replaced withnew hermatical sealed compressor of existing make &modelincluding soldering of liquid /gas pipe, cleaning the system arresting the leaking, vacuum sing, initial charging of oil & refrigerant gas as requiredincluding installation, testing & commissioning complete all as specified and as directed by Engineer-in-charge. |
| 74 | M& Lfor insulation for drain pipes and condensor copper pipes as per existing type rubber insulating materials suitable forVRF Plant complete as directed by Engr-in Charge. |
| 75 | Supply and fixing 2.5 sqmm multi core cable for connection between outdoor unit to indoor unit inluding PVC conduit of size 15/20mm dia complete all as directed by Engnr in charge.Note: The VRF AC Plant must be repaired or serviced through OEM (Carrier and Samsung) or his authorized Service Centre, necessary documents are to be submitted by the bidder to the department prior qualifying of the bidding. |
| 76 | Supply and charging of refrigerant Gas R-134 to summer cooling appliances all as specified and directed by Engr-in-charge. |
| 77 | Supply and charging of refrigerant Gas R-407C to summer cooling appliances all as specified and directed by Engr-in-charge. |
| 78 | Supply and charging of refrigerant Gas R-32 to summer cooling appliances all as specified and directed by Engr-in-charge. |
| 79 | Supply and charging of refrigerant Gas R-410A to summer cooling appliances all as specified and directed by Engr-in-charge. |
| 80 | Supply and charging of refrigerant Gas R-22 to summer cooling appliances all as specified and directed by Engr-in-charge. |